| HS Code | 642604 |
| Product Name | Tianma Powder Veterinary Grade API |
| Active Ingredient | Gastrodin (from Gastrodia elata) |
| Appearance | Fine light brown to yellowish-brown powder |
| Odor | Characteristic herbal odor |
| Solubility | Slightly soluble in cold water; soluble in hot water and ethanol |
| Pathogenic Microorganisms | Salmonella and Escherichia coli absent |
| Storage Conditions | Store in cool, dry, airtight containers protected from light |
| Shelf Life | 24 months from date of manufacture |
| Compatible Dosage Forms | Tablets, injections, capsules, powders, granules, premix, and solutions |
As an accredited Tianma Powder Veterinary Grade API for Tablets / Injections / Capsules / Powders / Granules / Premix / Solutions factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Available in 25 kg fiber drums with double polyethylene liners, sealed, labeled, and moisture-protected for veterinary pharmaceutical manufacturing. |
| Container Loading (20′ FCL) | Tianma powder veterinary grade API is loaded into a 20' FCL palletized, secured in sealed drums/cartons, ensuring safe, dry transport. |
| Shipping | Tianma Powder Veterinary Grade API ships in sealed, moisture-proof containers with tamper-evident packaging. Transport via temperature-controlled, secure freight to preserve potency. Includes full documentation—COA, MSDS, and origin certificate. Ensure compliance with local veterinary regulations. International air/sea shipping available with strict handling protocols for safety. |
| Storage | Store in a cool, dry, well-ventilated area at controlled room temperature, away from direct sunlight, heat, and moisture. Keep container tightly closed when not in use. Protect from contamination and incompatible substances. Ensure segregation from food, feed, and non-veterinary products. Follow local regulations for handling and disposal. |
| Shelf Life | Shelf life: 24 months when stored in a cool, dry, airtight container away from light and moisture. |
Direct compression with Tianma Powder veterinary-grade API requires that the powder be matched to rotary press feed frame behavior rather than to laboratory hand-fill conditions. If the Dv90 measured by laser diffraction per USP <429> exceeds 250 µm, the lot is passed through a conical mill fitted with a 0.020 in. round-hole screen at 1,200 rpm; this controls oversize that otherwise raises weight variation at press speeds above 40 rpm. Flow function coefficient is measured on a Schulze ring shear tester per ASTM D6773-22; values below 4.0 indicate that gravity-fed die filling is not reliable, and the formula is switched to roller compaction or wet granulation. For direct compression, a twin-shell V-blender with intensifier bar is operated at 25 rpm for 10 min to prepare a 1:10 pre-blend, followed by a 1:100 main blend. Magnesium stearate is screened through a 60 mesh sieve and added at 0.25% w/w to 1.0% w/w; over-lubrication above 2.0% w/w depresses tablet tensile strength below the 1.7 MPa threshold needed for chewable veterinary tablets tested by diametral compression. A rotary tablet press with forced feed is operated at 20–35 kN compaction force and 30–50 rpm; fill weight is checked every 15 min using 10 tablets, and final dose uniformity is assessed by USP <905> with an acceptance value not more than 15.0. Disintegration is run by USP <701> in 37 ± 2 °C water, with a limit of 15 min for immediate-release veterinary tablets. Dissolution release uses USP <711> Apparatus 2 at 50 rpm, with Q = 80% at 30 min unless a veterinary monograph specifies otherwise.
Sterile injectable manufacture using the API powder begins with solubility mapping in compendial buffers. If the lot dissolves to at least 20 mg/mL in a pH 4.0–6.5 citrate or phosphate buffer at 20–25 °C, the solution can be processed through a 0.45 µm prefilter and a final 0.22 µm membrane. Throughput limitations are governed by filter-loading capacity, solution viscosity, and the particle load remaining after reconstitution. A 10-inch cartridge train with 0.45 µm prefiltration and 0.22 µm final filtration is operated with differential pressure below 2.0 bar; a pressure above 1.5 bar during the first 10 min signals the need for clarification by centrifugation or bag filtration. The final filter integrity is tested before and after filling using the filter manufacturer's validated bubble point specification, and bacterial retention is supported by ASTM F838-20. If the API solution is thermostable, terminal sterilization at 121 °C for 15 min with F0 ≥ 8.0 is preferred; where thermolability is suspected, stability is assessed per VICH GL3, and published data for this specific configuration is limited. In thermolabile cases, the process defaults to aseptic filtration through a sterilizing-grade membrane into depyrogenated vials in a Class A isolator with Class B background per EU GMP Annex 1. If solubility is below 10 mg/mL at target pH, a cosolvent or pH adjustment is required; below 1 mg/mL, solution presentation is not practical and suspension or lyophilization should be considered.
Fill volume tolerance for 10 mL vials is set at ±1.0%, and the filling line uses a Bausch+Ströbel VarioSys aseptic filling machine equipped with peristaltic pumps; contact tubing is replaced after 8 h to limit leachable accumulation. Post-fill inspection distinguishes visible particulates per USP <790>, while subvisible particulate limits follow USP <788>: not more than 6,000 particles per container ≥10 µm and not more than 600 particles per container ≥25 µm for small-volume injections. Endotoxin load is calculated from K/M per USP <85>; with K = 5 EU/kg and a maximum veterinary dose of 10 mg/kg, the limit is 0.5 EU/mg. Media fill acceptance follows EU GMP Annex 1, and environmental monitoring is continued through the fill; any positive unit in a run of 5,000 triggers a process review. If oxidative degradation is identified by forced degradation per VICH GL3, the formulation is protected by nitrogen purging to dissolved oxygen below 0.5 ppm and sodium metabisulfite at 0.1% w/v. Amine-based buffers are avoided if the active contains ester moieties because aminolysis can lower assay below 95.0%; this incompatibility is documented by pH-rate studies.
Unlike compression-based tablet lines, powder-in-capsule filling shifts the critical control point from compaction mechanics to tamping-pin densification and shell moisture exchange. The API powder is preblended with microcrystalline cellulose or pregelatinized starch through a 1:10 geometric dilution in a 250 L bin blender at 8 rpm for 15 min. For size 0 hard gelatin capsules, a Bosch GKF 2600 tamping-pin capsule filler is configured with tamping force at station 3 limited to 200 N to avoid cake formation; fill weight is checked every 30 min on 20 capsules, and variation is maintained within ±5.0%. When dynamic vapor sorption shows moisture uptake above 2.0% w/w at 50% RH, the filling suite is held at ≤30% RH; for HPMC shells, the room is kept at 35–45% RH because conditions below 30% RH increase shell brittleness and ejection defects. Capsule contents are tested for dissolution by USP <711> Apparatus 1 at 100 rpm, with Q = 80% at 30 min. Because no compression is applied, tableting-induced polymorphic transformation is avoided, but hygroscopic fill blends may still require a silica gel desiccant at 1 g per 10 capsules in HDPE packaging; moisture pick-up is monitored over 12 months at 25 °C/60% RH per VICH GL3.
For oral powder sachets, segregation control is the dominant release risk. When the label claim is below 100 mg per sachet, a 1:10 pre-blend and a 1:100 main blend are screened through a 30 mesh stainless steel sieve before mixing in a 500 L bin blender at 8 rpm for 20 min. Segregation potential is tested by sampling the top, middle, and bottom of the blender after 5 min of vibration on a sieve shaker; an assay difference above 5.0% relative to the mean indicates the need for finer API particles or 0.5% w/w colloidal silicon dioxide. Sachet filling is carried out on a vertical form-fill-seal line with an auger filler; for a 2 g target fill weight, fill weight variation is maintained within ±7.5%, and seal integrity is tested at 200–300 mbar vacuum. Foil laminate moisture barrier is selected by water vapor transmission rate per ASTM F1249-20; a laminate with 0.06 g/m²/day at 38 °C/90% RH is used for moisture-sensitive formulas. Finished sachet dose uniformity is assessed by USP <905> with an acceptance value not more than 15.0; the auger fill speed is limited to 40 strokes/min if the powder has a Carr Index above 25 as measured by USP <1174>.
| Presentation | Critical control | Test method/standard | Typical numerical limit |
|---|---|---|---|
| Tablets | Dose uniformity | USP <905> | AV ≤ 15.0 for 10 units |
| Injectable solution | Subvisible particulates | USP <788> | ≤ 6,000/container ≥10 µm; ≤ 600/container ≥25 µm |
| Capsules | Fill weight variation | USP <905> | ±5.0% for 20 capsules |
| Oral powder sachets | Segregation assay | Blender sampling + USP <905> | Mean deviation ≤ 5.0%; AV ≤ 15.0 for finished units |
| Granules | Loss on drying | USP <731> | 1.0–2.0% w/w after drying |
| Premix | Feed homogeneity | 21 CFR 225 + FDA-CVM sampling | CV ≤ 5.0% at 10 locations per ton |
| Oral solution | pH | USP <791> | ±0.1 from specification |
Producing free-flowing oral granules from the API powder begins with fluid-bed top-spray granulation in a Glatt GPCG 3 unit equipped with a 1.2 mm twin-fluid nozzle. The binder phase is prepared by dissolving hydroxypropyl methylcellulose E5 in purified water at 60 °C, cooling to 25 °C, and applying as a 3.0% w/w solution at a spray rate of 12–18 g/min. Inlet air temperature is set to 65 °C; outlet air temperature is maintained between 35 °C and 40 °C; atomization air pressure is 1.5 bar. Granulation endpoint is reached when the Dv50 of the granulate reaches 180–250 µm and loss on drying by USP <731> is 1.0–2.0% w/w. Over-wetting beyond 3.0% w/w residual moisture produces agglomerates that require a 1.0 mm screen and reduces granule flow. After drying, granules are passed through a 12 mesh sieve and retained on a 60 mesh sieve; the 12–60 mesh fraction is filled into sachets or high-density polyethylene bottles. Tap density is controlled between 0.45 g/mL and 0.65 g/mL by adjusting binder viscosity; granules below 0.40 g/mL are rejected because they raise dust and sachet fill variability. Dissolution of immediate-release oral granules is tested by USP <711> Apparatus 2 at 50 rpm, with 80% release at 30 min. For enteric-coated granules, a subcoat of 2.0% w/w hydroxypropyl methylcellulose is followed by a methacrylic acid copolymer dispersion; acid-stage release is not more than 10% after 2 h in 0.1 N HCl, and buffer-stage release is not less than 80% at 45 min in pH 6.8 phosphate buffer. Binder solution is filtered through a 150 µm mesh before spraying to reduce nozzle blockage and batch-to-batch spray rate drift.
When the premix is applied to pelleted feed instead of meal feed, the API powder must be stabilized in a carrier that withstands post-pelleting coating or surface application without segregation. The premix is manufactured as a Type A medicated article under 21 CFR 226; downstream dilution to Type B or Type C medicated feed falls under 21 CFR 225. A 0.5% w/w active premix is prepared by mixing the API powder with ground limestone or rice hulls in a double-ribbon blender at 20 rpm for 15 min; carrier particle size is matched to the feed pellet diameter to reduce transport segregation. If the premix is applied after pelleting, soybean oil at 1.0% w/w to 2.0% w/w is sprayed onto heated pellets at 45 °C, and the premix is adhered in a rotary coater. For fixed exit mixers, 10 incremental samples are taken per ton from the discharge stream; the assay coefficient of variation must be below 5.0% for medicated feed per FDA-CVM sampling guidance. If the API is heat-sensitive, the premix is not added before pelleting because pellet die temperatures above 70 °C can reduce assay below 95.0%; instead, a vacuum coater at 150 mbar for 8 min is used to achieve a surface distribution variation below 8.0% CV. Finished medicated feed is assayed by HPLC with method validation per VICH GL1 and stability under 25 °C/60% RH for 12 months per VICH GL3. If an iron oxide tracer is required, it is added at 0.1% w/w and the tracer CV below 5.0% is used as a surrogate for blend homogeneity. Published data for this specific API in pelleted feed is limited; therefore, process qualification requires three consecutive production-scale batches with assay RSD below 5.0% before release.
Oral solution formulas require pH adjustment within a range where the API remains in solution for the entire shelf life. A titration curve is prepared in 0.05 M buffer systems from pH 2.0 to 8.0; if solubility drops below 10 mg/mL at a given pH, that pH region is excluded unless a cosolvent is justified by a stability study. Typical solvent systems use propylene glycol 10.0% v/v to 30.0% v/v or glycerin 5.0% v/v to 15.0% v/v, but feline products avoid propylene glycol because repeated doses above 1.0 g/kg/day have been associated with Heinz body formation. The solution is filled into amber polyethylene terephthalate bottles with child-resistant closures, and headspace oxygen is purged with nitrogen to below 2.0% v/v if forced degradation shows oxidation at 40 °C/75% RH for 6 months per VICH GL3. Preservative systems are selected by antimicrobial effectiveness testing per USP <51>; methylparaben at 0.1% w/v and propylparaben at 0.02% w/v are common choices, but sorbitol may reduce free paraben concentration and require adjustment. pH is checked after batch makeup and adjusted within ±0.1 unit of the registered specification using 1 N hydrochloric acid or sodium hydroxide; pH is measured per USP <791>. Packaging leachables are monitored by storing filled solutions at 40 °C/75% RH for 6 months and testing common extractables by GC-MS or LC-MS per USP <1664>. The oral solution is dosed with calibrated oral syringes or pump dispensers; delivered dose tolerance is ±5.0% for doses above 1 mL and ±10.0% for doses below 1 mL. After final clarification through a 10 µm filter, the solution is filled on a peristaltic pump line at 20–40 bottles/min; extractable polymer tubing is replaced after 8 h of contact to limit leachable accumulation.
Competitive Tianma Powder Veterinary Grade API for Tablets / Injections / Capsules / Powders / Granules / Premix / Solutions prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618963613625 or mail to sales10@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618963613625
Email: sales10@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
Tianma Powder Veterinary Grade API is supplied as a controlled-particle-size active substance for incorporation into tablets, injections, capsules, powders, granules, premixes, and solutions. The Tianma Powder designation functions as the commercial model identifier rather than a discrete numerical model code; batch traceability is maintained through the manufacturer’s batch number and the active substance monograph. The grade is distinguished from commodity technical powders by a release specification aligned with veterinary pharmacopoeial expectations and by the requirement to support multiple downstream unit operations. The powder may be directly compressed into tablets or filled into hard capsules after flow and compaction evaluation; it may also be dissolved for sterile injectable manufacturing when the batch certificate includes bacterial endotoxin and particulate control data. The manufacturer’s certificate of analysis should be reviewed for assay, related substances, residual solvents, and residual moisture before use. Published stability data for this specific configuration is limited, so each dosage-form developer should generate formulation-specific stability and compatibility data under ICH/VICH conditions.
For injectable solutions, the powder is not automatically sterile or pyrogen-free. Suitability depends on bacterial endotoxin level, sub-visible particulate burden, and the ability of the formulator to remove or inactivate bioburden. The batch certificate should include a compendial endotoxin test, for example Ph. Eur. 2.6.14 or USP <85>, with a limit tied to the maximum intended dose and animal body weight. A typical endotoxin limit for a parenteral veterinary API is ≤ 0.25 EU/mg, but the final limit must be derived from the K/M relationship, where K is 5 EU/kg for small-volume parenterals and M is the maximum dose per kilogram of body weight. Sub-visible particulate matter after reconstitution or filling is assessed according to USP <788> or Ph. Eur. 2.9.19; solutions for injection should meet the light obscuration particle count thresholds of ≥ 10 µm and ≥ 25 µm. If the powder is used in an injectable emulsion or suspension, the particle size distribution must be controlled by laser diffraction according to ISO 13320:2020 to prevent capillary blockage or tissue irritation. Table 1 summarizes representative release parameters for a veterinary-grade API intended for multiple dosage forms. The values are typical industrial acceptance bands, not product-specific certificates; the batch-specific certificate of analysis prevails.
| Parameter | Test method / standard | Typical acceptance band |
|---|---|---|
| Appearance | Visual inspection | White to off-white powder |
| Identification | IR spectrophotometry | Corresponds to reference spectrum |
| Assay (dried basis) | HPLC | 98.0–102.0% |
| Loss on drying | Ph. Eur. 2.2.32 | ≤ 0.5% |
| Sulfated ash | Ph. Eur. 2.4.14 | ≤ 0.1% |
| Heavy metals | Ph. Eur. 2.4.8 | ≤ 20 ppm |
| Residual solvents | VICH GL18 / Ph. Eur. 2.4.24 | Class 1 absent or ≤ 1 ppm; Class 2 within limits |
| Bulk density | USP <616> | 0.35–0.65 g/cm³ |
| Particle size D90 | Laser diffraction ISO 13320:2020 | ≤ 100 µm or agreed |
| Microbial limits | Ph. Eur. 2.6.12 / 2.6.13 | TAMC ≤ 10³ CFU/g, TYMC ≤ 10² CFU/g |
| Bacterial endotoxins | Ph. Eur. 2.6.14 / USP <85> | ≤ 0.25 EU/mg if injectable |
Before tablet and capsule batches are released from the powder, flow and compaction properties are measured because the powder’s performance on a rotary press or capsule filler is not guaranteed by chemical assay alone. Bulk density and tapped density are determined according to USP <616>; the Hausner ratio and Carr compressibility index are calculated from the measured values. A Hausner ratio below 1.25 is generally associated with acceptable free-flowing direct compression, while values above 1.35 often require granulation or glidant addition. Angle of repose measurements provide additional flow information: values of 25–30° suggest excellent flow, 31–35° good flow, 36–40° fair flow, and greater than 40° poor flow. The particle size distribution is obtained by laser diffraction per ISO 13320:2020; typical D90 values for direct compression powders are ≤ 100 µm, but the exact distribution is agreed between the API manufacturer and the dosage-form developer. On a rotary tablet press equipped with a precompression station, the powder should be evaluated for ejection force, sticking, and capping; compression force settings are formulation-specific and should be established by compaction simulation rather than extrapolated from other APIs. Capsule filling on a dosator or tamping-pin machine requires sufficient powder cohesiveness to form a plug. Fill weight variation should remain within the acceptance limits of Ph. Eur. 2.9.5 or USP <905> for the selected capsule size. Dissolution testing is performed according to USP <711> or Ph. Eur. 2.9.3 using the specified apparatus and medium.
High-dose tablets and capsules often require granulation because the raw powder may exhibit poor flow or segregation. Wet granulation in a high-shear mixer requires monitoring impeller speed, chopper speed, and liquid addition rate; over-granulation produces dense agglomerates that resist disintegration, while under-granulation leaves fine particles that segregate during compression. The granulate is dried to a target loss on drying, typically 1.0–3.0% for many immediate-release formulations, then milled through a screen with a defined aperture. Drying end-point is confirmed by Karl Fischer titration or loss on drying according to Ph. Eur. 2.2.32. Roller compaction is an alternative when the API is moisture-sensitive or when solvent exposure must be avoided; roll force, roll speed, and screen size control granule density and tablet tensile strength. The resulting granules are blended with disintegrant and lubricant, and tablet hardness is measured according to USP <1217>; friability is assessed according to Ph. Eur. 2.9.7. Dissolution failure at this stage is often traced to over-lubrication or excessive granule hardness rather than chemical instability. If the powder is granulated for capsule filling, the granule size distribution should be controlled to maintain consistent plug formation; the D50 and D10 are often more informative than D90 for capsule fill uniformity.
Formulating a solution for injection from the powder requires a solvent system that achieves complete dissolution without precipitation during storage. The dissolved active substance is filtered through a 0.22 µm membrane filter; filter compatibility should be confirmed because some APIs adsorb to nylon, polyethersulfone, or PVDF membranes. Terminal sterilization by moist heat at 121 °C for 15 min is acceptable only where stability data demonstrate no unacceptable degradation in the final container. If the molecule is thermolabile, aseptic filtration followed by filling in an ISO 14644-1:2015 Class 5 environment is required. Tonicity adjustment with sodium chloride or dextrose is evaluated by osmolality; the final solution should meet the product-specific specification, typically 285–310 mOsm/kg for isotonic preparations. The container-closure system is tested for clarity, pH, and sub-visible particles after storage. Compatibility with siliconized elastomeric closures and rubber stoppers should be assessed because adsorption or extractables can alter solution purity. Published data for this specific configuration is limited; therefore batch-specific compatibility and stability studies are mandatory before release.
In feed premix manufacturing, the powder is first blended with a carrier such as ground limestone or corn cob to form a concentrated premix, then diluted into complete feed. Mixing uniformity is assessed by sampling multiple points and calculating the coefficient of variation; a CV of ≤ 5% is a common acceptance criterion for medicated premixes, but the exact limit depends on the active substance and target species. Equipment selection includes horizontal ribbon mixers, paddle mixers, or double-cone blenders; mixing time is established by measuring homogeneity at multiple time points rather than fixed intervals. Particle size differences between the API and carrier create segregation risk; the particle size distribution is controlled by sieve analysis or laser diffraction per ISO 13320:2020. Granules for oral administration or feed incorporation may be produced by dry granulation to improve handling and reduce dust. Sampling protocols follow ISO 6497, and the completed feed is assayed to confirm target concentration. Dust control during transfer is required because fine API particles can deposit in exhaust ducts and create cross-contamination risk. Where the premix is intended for food-producing species, withdrawal periods are determined from residue depletion studies; the API’s particle size and formulation matrix can influence the time required for tissue residues to fall below the maximum residue limit.
The veterinary grade differs operationally from human-grade and technical-grade powders in the constraints applied to endotoxin, microbial burden, and particle size. Human-grade active substances may meet pharmacopoeial purity but are not automatically supported by target-animal safety or residue depletion data; their use in food-producing species may violate regulatory withdrawal period requirements. Technical-grade powders may contain higher levels of related substances or heavy metals and are not manufactured under full GMP. Feed-grade powders often consist of the active substance adsorbed onto carriers and have lower assay values. Table 2 summarizes the operational distinction.
| Attribute | Tianma Powder Veterinary Grade | Human-Grade API | Technical/Feed-Grade Powder |
|---|---|---|---|
| Assay | 98.0–102.0% dried basis | 98.0–102.0% dried basis | Variable, often lower |
| Endotoxin control | Included per Ph. Eur. 2.6.14 / USP <85> | Usually included | Not controlled |
| Microbial limits | Ph. Eur. 5.1.4 or 2.6.12 | Harmonized | Not controlled |
| Particle size control | Specified D10/D50/D90 by ISO 13320:2020 | May be specified | Broad or not specified |
| Residual solvents | VICH GL18 | ICH Q3C | Not always controlled |
| GMP manufacturing | Yes | Yes | Not always |
| Target-animal residue data | Veterinary dossier | Not provided | Not provided |
Typically, the powder is packed in double polyethylene liners inside fibre or HDPE drums, with desiccant where the API is hygroscopic. The material should be dispensed in a humidity-controlled area; exposure to relative humidity above 60% may cause moisture uptake and flow deterioration. Pre-drying according to the manufacturer’s instructions is required for hygroscopic batches. The powder should not be combined with strong oxidising agents unless compatibility studies demonstrate safety. Safety during handling is based on the active substance’s toxicological profile; containment measures such as local exhaust ventilation or isolators are specified by the safety data sheet. Re-evaluation of the batch after prolonged storage should include assay, related substances, moisture, and microbial enumeration. Containers should be closed immediately after use to limit exposure to oxygen and light.