Products

Jiawei Jidan Powder Veterinary Grade API for Tablets / Injections / Capsules / Powders / Granules / Premix / Solutions

    • Product Name: Jiawei Jidan Powder Veterinary Grade API for Tablets / Injections / Capsules / Powders / Granules / Premix / Solutions
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: sales10@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 301602
    Product Name Jiawei Jidan Powder
    Chinese Name 加味鸡胆散
    Product Category Veterinary Grade API
    Grade Veterinary Grade
    Api Form Powder
    Active Ingredients Chicken bile powder and added herbal ingredients
    Appearance Brownish-yellow to brown fine powder
    Color Brownish-yellow to brown
    Odor Characteristic
    Taste Bitter
    Solubility Slightly soluble in water
    Moisture ≤ 5.0%
    Ash ≤ 5.0%
    Heavy Metals ≤ 10 ppm
    Arsenic ≤ 2 ppm
    Microbial Limit ≤ 1000 CFU/g
    Particle Size ≥ 80 mesh
    Identification TLC
    Dosage Forms Tablets, Injections, Capsules, Powders, Granules, Premix, Solutions
    Application Veterinary use
    Target Animals Poultry, swine, cattle, sheep, goats
    Packaging 25 kg/drum, double plastic bags inside
    Storage Cool, dry, ventilated place, away from light
    Shelf Life 24 months
    Certification GMP, ISO
    Origin China
    Moq 1 kg

    As an accredited Jiawei Jidan Powder Veterinary Grade API for Tablets / Injections / Capsules / Powders / Granules / Premix / Solutions factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Packaged in 25 kg double-lined fiber drums with sealed polyethylene inner bags, clearly labeled for veterinary-grade Jiawei Jidan Powder API.
    Container Loading (20′ FCL) 20′ FCL container loading for Jiawei Jidan Powder Veterinary Grade API, suitable for tablets, injections, capsules, powders, granules, premix, solutions.
    Shipping Jiawei Jidan Powder Veterinary Grade API is shipped in sealed, moisture-resistant containers under ambient or controlled conditions as required. Packaging options include drums, bottles, and foil bags for tablets, injections, capsules, powders, granules, premix, or solutions. Shipments comply with IATA/IMDG/ADR and local regulations, with proper labeling, MSDS, and documentation.
    Storage Store Jiawei Jidan Powder Veterinary Grade API in a cool, dry, well-ventilated place, away from direct sunlight, heat, moisture, and incompatible chemicals. Keep containers tightly closed when not in use. Segregate from food, feed, and drinking water to prevent contamination. Keep out of reach of children and animals. Use appropriate PPE and follow the manufacturer’s label, SDS, and local regulations.
    Shelf Life Typically 24–36 months in unopened, sealed original packaging; store cool, dry, protected from light; confirm exact expiry on COA.
    Application of Jiawei Jidan Powder Veterinary Grade API for Tablets / Injections / Capsules / Powders / Granules / Premix / Solutions

    Medicated Premix Manufacture Inside a 2,000 L Paddle Mixer

    When Jiawei Jidan Powder Veterinary Grade API is converted into a medicated premix, the first processing constraint is the physical behaviour of the powder in a low-moisture carrier system. The powder is typically brought into the feed mill as a 80-mesh to 120-mesh free-flowing material, but batch records must confirm the actual particle-size distribution because cellulose-rich botanical fragments above 1,000 µm segregate vertically in the mixer. A validated 5% (w/w) premix intermediate is produced by geometric dilution into a milled rice-hull or calcium carbonate carrier; the final complete-feed inclusion rate is set solely by the approved veterinary medicinal product registration and the target species dose. No universal ratio applies across layer, broiler, or breeder feeds. The mixing vessel is a single-shaft paddle mixer with a working volume of 2,000 L, a fill ratio of 60–70%, and a shaft speed of 50–60 rpm. Homogeneity release testing uses six sampling points drawn after 7 min and 12 min, with a coefficient of variation not greater than 5% for the chemical or botanical marker. If the powder has been stored above 60% RH, it is pre-dried at 50°C for 2 h to prevent polysaccharide-based soft agglomerates from binding carrier fines. Terminal premixes are filled into 25 kg paper-polyethylene sacks or 1,000 kg FIBC bags under nitrogen flush when moisture uptake exceeds 0.5% in 24 h. The finished premix is subsequently diluted into layer-breeder feeds, custom mineral-vitamin premix bases, or top-dress concentrates, and the batch must be traceable from API lot to farm delivery under 21 CFR Part 225 medicated feed GMP.

    What Limits Drinking-Water Dosing When the Active Matrix Is a Botanical Powder?

    Drinking-water administration of Jiawei Jidan Powder Veterinary Grade API depends on the formation of a fast-hydrating, nipple-compatible dispersion rather than a true molecular solution. Soluble-powder development starts with a solubility screen at 2 g/L in purified water at 20°C and 37°C, stirred at 200 rpm for 30 min; if material retained on a 45 µm sieve exceeds 5% of the starting mass, direct metering through a proportioner is rejected. Wet granulation is then used to embed the API in a carrier matrix of dextrose monohydrate, citric acid, and a low-foaming surfactant accepted for drinking-water use. The granulated powder is dried to loss on drying below 3% and milled through a 60-mesh screen. On-farm proportioners such as Dosatron-type units must be calibrated with the actual sachet stock solution because pump hysteresis and air entrainment change final water concentration. For a 1,000 L header tank, the stock solution is required to show no visible insoluble film when a light beam passes through a 10 cm path length; undissolved matter above 0.1% is considered a nozzle-clogging risk for nipple drinkers. Batch release includes pH, loss on drying, wet-sieving residue, and reconstitution time in deionized water. The terminal product is a multi-dose sachet or 1 kg tub that is diluted into drinking water for laying flocks or breeder pullets, with water consumption monitoring used as a process control for dose uniformity.

    Tablet Compression of High-Load Botanical Powders Forces a Granulation Step

    Tablet manufacture with Jiawei Jidan Powder Veterinary Grade API is normally not feasible by direct compression at active fractions above 30% (w/w). The dry powder exhibits poor flow with compressibility indices above 25%, and ejection forces rise sharply when the blend moisture exceeds 4%. A wet-granulation route is therefore selected. The API is blended with microcrystalline cellulose PH 102, lactose monohydrate, croscarmellose sodium, and pregelatinized starch; povidone K30 solution at 5% (w/v) is added at 25–35% of dry-blend mass in a high-shear granulator. Granules are dried at 50°C until loss on drying is 2–4%, milled through a 1.0 mm screen, and lubricated with magnesium stearate 0.5–0.75% (w/w) and colloidal silicon dioxide 0.25% (w/w). Tablets of 1,200 mg total mass are compressed on a rotary press with 16 mm oblong tooling. Hardness is controlled at 60–80 N, friability not more than 1.0% by USP <1216>, and disintegration not more than 30 min in water at 37°C by USP <701>. Weight uniformity is verified by USP <905>. Terminal products are PVC-aluminium blisters of 10 or 30 tablets for oral dosing in companion animals or small ruminants, with batch traceability to the granulation lot and compression machine setting parameters.

    In capsule-filling operations, Jiawei Jidan Powder Veterinary Grade API requires feedable granulate because the neat powder often has bulk densities below 0.45 g/mL and tapped densities above 0.75 g/mL, yielding large fill-weight variability. Dry granulation is preferred over wet granulation when the objective is to avoid thermal exposure of volatile markers. The API is roll-compacted at a roll pressure of 30–50 bar and screened through a 0.8 mm sieve to obtain granules with a porosity that collapses under tamping-pin force. The final powder blend is adjusted to a tapped density of 0.62–0.75 g/mL, an angle of repose not more than 35°, and a compressibility index not more than 20% by USP <1174>. A Size 0 or Size 1 two-piece hard gelatin or HPMC capsule is filled on a dosator-type or dosing-disc machine at 60–80% of rated speed to reduce split-capsule rejects. The target fill weight is established by the approved veterinary dose, but filling at 450–550 mg per Size 1 capsule may serve only as an equipment-setting pilot point. Weight variation is checked at 10 min intervals using USP <905>. Terminal capsules are packaged in HDPE bottles with desiccant when the capsule shell moisture specification is below 12% at 25°C/60% RH. This oral solid form is intended for dogs, cats, or exotic companion species where body-weight-adjusted dosing is required and where feed/water administration is not controlled.

    For injectable presentations, Jiawei Jidan Powder Veterinary Grade API is the highest-risk conversion route and is developed only when the master formula and stability data support a fully parenteral grade. Aqueous extraction of the powder in water for injection at 50–70°C for 2–4 h may remove soluble active constituents, but high-molecular-weight polysaccharides, proteins, and lipophilic components can be lost during cooling. The solution is clarified by progressive depth filtration, then membrane-filtered through 0.45 µm followed by 0.22 µm sterilizing-grade filter. If filter capacity is below 10 L/m², the botanical matrix is not suitable for aseptic filtration without pre-treatment. Sterility is verified according to USP <71> or EP 2.6.1; bacterial endotoxin testing uses USP <85>; particulate matter is controlled to USP <788> limits for large-volume injectables. Terminal sterilization at 121°C for 15 min is applied only if stability-indicating assays demonstrate marker retention above 95%; published data for this specific powder in terminal-sterilized injectable form is limited, so a feasibility batch is mandatory before committing to commercial scale. The formulation is filled into 10 mL or 50 mL glass vials under nitrogen or argon if oxidative markers show colour shift within 48 h of exposure. Avoid contact with polyvalent metal ions such as Fe³⁺ and Al³⁺ if polyphenolic constituents are present; insoluble chelates can block the sterilizing filter and form visible precipitates. The terminal product is a sterile injectable solution for cattle, swine, or poultry veterinary use, and batch release includes pH, osmolality, active marker assay, sterility, endotoxin, and particulate matter.

    Granulation for Oral Top-Dress on Feed Requires a Defined Particle-Size Window

    A defined particle-size window of 500–1,000 µm is the primary release criterion for oral top-dress granules based on Jiawei Jidan Powder Veterinary Grade API. The fluid-bed top-spray process charges the API with lactose monohydrate and pregelatinized starch. A binder solution of povidone K30 or hydroxypropyl methylcellulose at 3–5% (w/w) is sprayed at an inlet air temperature of 55–65°C, maintaining product temperature between 35°C and 40°C. Drying continues until the granule moisture is below 2%, and the dried granulate is classified through 16-mesh and 35-mesh sieves. This size range reduces segregation from mash feed and allows uniform sprinkling over pellets. Granule strength is controlled by attrition testing: fines passing a 60-mesh sieve after a 10 min tumbling test should not exceed 5%. The terminal product is packed in 1 kg sachets or 25 kg drums for farm-level top-dress application. In layer-breeder operations, top-dress dosing is recorded in batch sheets with feed consumption monitoring because uneven distribution to dominant animals is an inherent limitation of this route.

    When oral liquid dosing is the preferred route, Jiawei Jidan Powder Veterinary Grade API must address sedimentation, microbial growth, and preservative interaction separately from solid-dose routes. The API extract or ultra-fine powder is dispersed in purified water with sorbitol solution 70% (w/w), propylene glycol, and a suspending agent such as microcrystalline cellulose plus carboxymethyl cellulose. A typical pilot batch may target a final concentration of 50 mg/mL of dried powder equivalent, but the actual registered concentration is derived from the approved veterinary product specification. Preservative efficacy must be confirmed by USP <51> antimicrobial effectiveness testing; if natural polyphenols in the drug substance bind methylparaben or propylparaben, the preservative recovery by HPLC can fall below 90% and the preservative system must be changed. The manufacturing process uses a high-shear rotor-stator mixer at 3,000 rpm for 15 min to reduce particle aggregates, followed by homogenization at 200–300 bar. The finished liquid is filled into 100 mL or 500 mL HDPE bottles with a measuring cap. Storage stability is assessed at 25°C/60% RH and 40°C/75% RH; phase separation greater than 1% in 72 h is a rejection criterion. This route is intended for neonatal calves, lambs, or herd administration where individual oral liquid dosing through a drench gun improves dose accuracy compared with feed medication.

    Free Quote

    Competitive Jiawei Jidan Powder Veterinary Grade API for Tablets / Injections / Capsules / Powders / Granules / Premix / Solutions prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618963613625 or mail to sales10@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618963613625

    Email: sales10@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Jiawei Jidan Powder Veterinary Grade API for Tablets / Injections / Capsules / Powders / Granules / Premix / Solutions is an unformulated active pharmaceutical ingredient supplied as a powder for downstream veterinary dosage form development. The product model designation is assigned by the batch manufacturing record and appears on the label as a manufacturer product code; the code denotes the release specification profile rather than a finished formulation number. Release criteria typically address appearance, identity, assay, loss on drying, residue on ignition, residual solvents, particle size distribution, and microbial enumeration. Published data for this specific configuration is limited; consequently, the certificate of analysis is the operative specification. The material contains no carrier, binder, glidant, or preservative. Unlike ready-to-use premixes or directly compressible granules, it must be incorporated into a qualified excipient system for each intended route or dosage form. Its veterinary-grade status means that the material is released under veterinary GMP batch documentation, but it is not a sterile injectable and it is not a certified reference standard. Because the powder is unformulated, incoming bulk density can vary within the approved specification range; downstream weighing systems should therefore be calibrated using the actual batch density rather than an assumed nominal value. The product model designation on the label should be cross-checked with the certificate of analysis and should not be used as a stability-indicating name.

    What Release Controls Are Assessed Before Multi-Dosage-Form Use?

    For solid oral forms, the powder is characterized for particle size distribution, bulk density, tapped density, Hausner ratio, and flow function. Release documentation includes USP <616> or Ph. Eur. 2.9.34 for bulk and tapped density, USP <1174> for powder flow observations, and USP <786> or Ph. Eur. 2.9.35 for particle size estimation by laser diffraction. Direct compression on a rotary tablet press may be influenced by feed frame fill dynamics; cohesive arching can occur when powder flow is below the die-fill requirement. A glidant such as colloidal silicon dioxide is evaluated between 0.2–1.0 wt%, but the optimal level is formulation-specific. Capsule filling on dosator nozzles is more sensitive to bulk density variation than tamping-pin systems. Low-dose tablets require blend uniformity testing because API particle size distribution affects content uniformity during tablet press discharge. Blend uniformity acceptance criteria should follow USP <905> or an equivalent veterinary pharmacopoeial method. Dry granulation via roller compaction may be used when the powder has poor flow; the compaction pressure and roll gap must be balanced to avoid compact hardness that reduces tabletability. The release method does not guarantee downstream flow; it supplies the physical data required to select mixing, filling, and compression parameters.

    Quality control matrix applicable to the unformulated veterinary API powder
    AttributeMethod or standard designationDosage-form relevance
    Bulk and tapped densityUSP <616>, Ph. Eur. 2.9.34Capsule fill weight, die fill
    Particle size distributionUSP <786>, Ph. Eur. 2.9.35Blend uniformity, dissolution
    Powder flowUSP <1174>Direct compression, capsule filling
    Loss on dryingUSP <731>Stability, hygroscopicity, granulation endpoint
    Microbial enumerationUSP <61>, USP <62>, Ph. Eur. 2.6.12Non-sterile oral dosage forms
    Bacterial endotoxinsUSP <85>, Ph. Eur. 2.6.14Injection and solution development
    Residual solventsUSP <467>, VICH GL18Veterinary medicinal product safety
    Elemental impuritiesICH Q3D, USP <232>/USP <233>Maximum daily dose safety

    Injectable solution preparation imposes additional control expectations beyond oral solid release. The API is not sterile upon receipt; downstream terminally sterilized or aseptic processing is required. Aqueous solubility is batch-specific and should be determined before compounding; no saturation concentration is assigned from published data for this specific configuration. Warehousing under relative humidity above 60% is an operational boundary: the powder should be equilibrated or dried before weighing to reduce moisture-related assay shift and flow variability. Filtration compatibility must be tested with polyethersulfone and nylon membranes because active compound adsorption may reduce recovery; no universal membrane type is designated without product-specific validation. Endotoxin control is evaluated on the formulated solution according to USP <85> or Ph. Eur. 2.6.14, not on the dry API alone. The product should not be combined with unvalidated preservative systems in aqueous vehicles because ionic strength and pH shifts during terminal sterilization may alter solubility and visible particle formation. For steam sterilization at 121 °C for 15 min, load probe studies should be performed to confirm that the active moiety remains within assay limits. Solution pH drift during autoclaving can be evaluated in a pilot-scale steam sterilizer with load probes placed at the cold spot. No preservative combination should be selected without a challenge test under USP <51> or Ph. Eur. 5.1.3 for multi-dose injectable solutions. Extractables and leachables risk assessment through the final container closure system is required for injectable development.

    Granulation and Premix Mixing Boundaries on Production-Scale Equipment

    For oral powders, granules, and feed premixes, carrier selection controls blend uniformity more than API particle size alone. Production-scale ribbon mixers operating below 30% of nominal volume may exhibit weak axial mixing; fill level should be recorded as part of batch documentation. Typical ribbon mixer working volume is between 30% and 70% of capacity. In a low-shear granulator, the powder is usually pre-blended with a portion of carrier before binder addition. The binder addition rate must be controlled to avoid overwetting and lump formation because the unformulated material can be hygroscopic. Sieving through a 60-mesh screen is used only after attrition tendency has been assessed; excessive sieving may shift particle size distribution and increase fines. For feed-applied granules, dryer inlet temperature and final granule moisture content influence subsequent flow, dissolution, and microbial stability. Published data for this specific configuration is limited; equipment-specific development batches are required. The use of fluid-bed drying rather than tray drying may reduce granule hardening, but the drying endpoint must be correlated with loss-on-drying results rather than fixed time cycles. Blending with mineral carriers such as calcium carbonate or dicalcium phosphate should include evaluation of pH interaction with the active ingredient. When prepared as a feed premix, a two-stage mixing protocol is required: first geometric dilution with a small carrier mass, then incorporation into the full batch. Bypassing this step can produce active-rich agglomerates that survive the mixer and cause assay hotspots.

    On a high-shear granulation line with bowl sizes from 100 L to 600 L, the powder is pre-mixed with intragranular fillers before binder addition to reduce API loss on the vessel wall. Impeller and chopper speeds are set according to the granule endpoint determined by torque monitoring; no universal endpoint exists. For a 250 L high-shear granulator, pre-mix time is often limited to 2–3 min to avoid excessive temperature rise. These values are process development starting points and must be confirmed with the specific formulation. In wet granulation, water addition rates of 1–3% of dry mass per minute may be a starting range but must be adjusted based on torque. If granules are too hard after drying, dissolution may be retarded; milling speed and screen size become critical process parameters. In tablet compression, over-lubrication with magnesium stearate in the range 0.5–1.5 wt% may reduce dissolution even when blend uniformity is acceptable. Therefore, lubrication time and total revolutions are controlled during scale-up. The product is unflavored; taste masking for oral veterinary tablets is a formulation function, not a property of the API. Tablet hardness and disintegration must be validated because the API can affect the compression profile of a standard formulation. If the powder is intended for capsule filling, bulk density adjustments through slugging or roller compaction may be evaluated when the as-received material cannot meet filling weight requirements.

    When the Concentrated Powder Replaces a Carrier-Diluted Premix in Feed Additives

    The material differs from carrier-based premixes because it is an unformulated active ingredient with no standardized dilution. A feed mill substituting this API for a 10% premix must recalculate the inclusion rate from the assay value on the certificate of analysis and the target active concentration in complete feed. In a 500 kg paddle mixer, direct addition of concentrated powder without a two-stage pre-blend can create content uniformity risk; a stepped dilution with ground corn or lactose is used to achieve a coefficient of variation below 5% as an operational target. The 5% value is a quality target, not a product guarantee. This product should not be considered equivalent to microencapsulated or sustained-release veterinary powders unless coating studies are performed. For feed additive application, the API may be applied onto a carrier by dry adsorption; the dry adsorption process requires a carrier with adequate absorption capacity, such as precipitated silica, to reduce segregation. Cross-contamination control in multi-product feed mills is critical because the concentrated nature of the API increases carryover risk; equipment cleaning validation should include active residue limits based on the lowest therapeutic dose of the next product. Carryover residue limits can be derived from the permitted daily exposure of the next product; cleaning validation should include swab and rinse sampling. Published data for this specific configuration is limited, and process analytical technology controls are preferred over fixed wash cycles.

    Compared to single-dosage-form veterinary APIs, Jiawei Jidan Powder is released against a multi-dosage-form specification that includes microbial enumeration for non-sterile oral forms and endotoxin guidance for parenteral development. It is not a certified reference standard and should not be used for calibration or identification of unknown samples. It differs from feed-grade additives because it is produced under veterinary GMP with documented batch records and change control. However, the absence of a carrier means that formulators must assume responsibility for blend uniformity, dissolution, stability, and residual solvent clearance. The release documentation may include residual solvents and elemental impurities per ICH Q3C and ICH Q3D; actual limits are method-defined and batch-specific. Compared to a manufacturer’s formulated premix, the powder has no label claim for active concentration per kilogram of carrier; all concentration statements must be derived from the certificate of analysis. If a use requires a specific model number beyond the manufacturer product code, the certificate of analysis is the authoritative source. The material is not necessarily interchangeable with another manufacturer’s API powder even if the active moiety is the same, because particle morphology, bulk density, and impurity profiles can differ.

    For oral solution preparation, the powder is dispersed in a small volume of vehicle to form a slurry before final dilution. Temperature and pH are controlled because they affect dissolution rate and chemical stability. In hard capsule filling, the powder may require pre-compaction or slugging if bulk density is too low. The final dosage form must be tested for content uniformity, dissolution, and microbial quality according to the applicable pharmacopoeial monograph. If the formulation is intended for injection, aseptic filtration or terminal sterilization is validated after reconstitution; the dry powder itself is not terminally sterilized. Each batch of the product should be sampled upon receipt, and the certificate of analysis should be reviewed against the approved specification before release for production. The product’s suitability for a given solution application is not confirmed until stability data are generated in the intended vehicle.

    Top