Products

Dilute Sulfuric Acid Veterinary Grade API for Tablets / Injections / Capsules / Powders / Granules / Premix / Solutions

    • Product Name: Dilute Sulfuric Acid Veterinary Grade API for Tablets / Injections / Capsules / Powders / Granules / Premix / Solutions
    • Factroy Site: Zhanjiang, Guangdong, China
    • Price Inquiry: sales10@ascent-petrochem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 355435
    Productname Dilute Sulfuric Acid Veterinary Grade API for Tablets / Injections / Capsules / Powders / Granules / Premix / Solutions
    Chemicalname Sulfuric acid
    Synonyms Oil of vitriol; Hydrogen sulfate; Sulphuric acid
    Grade Veterinary Grade
    Apistage Active Pharmaceutical Ingredient
    Casnumber 7664-93-9
    Einecscode 231-639-5
    Molecularformula H2SO4
    Molecularweight 98.079 g/mol
    Appearance Clear, colorless to slightly yellow, odorless liquid
    Concentration Dilute, typically 0.1 N to 1 N
    Ph Strongly acidic; pH < 1 for concentrated, pH 1-3 for dilute solutions
    Solubility Miscible with water; soluble in ethanol
    Dosageforms Tablets, Injections, Capsules, Powders, Granules, Premix, Solutions
    Veterinaryuse pH adjustment, acidification, supportive therapy
    Storageconditions Store in a cool, dry, well-ventilated area away from bases, metals, and organic materials
    Shelflife 24 months when stored properly
    Packaging HDPE drums, glass bottles, plastic containers
    Hazardclass Corrosive
    Unnumber 1830
    Packinggroup II
    Qualitystandard Complies with veterinary grade specifications
    Assay Typically 95-98% for concentrated; dilute varies
    Impurities Heavy metals, arsenic, iron, chloride, nitrate, reducing substances

    As an accredited Dilute Sulfuric Acid Veterinary Grade API for Tablets / Injections / Capsules / Powders / Granules / Premix / Solutions factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Dilute Sulfuric Acid Veterinary Grade API supplied in 25 L HDPE jerrycans, securely sealed and labeled, with 200 L drum options.
    Container Loading (20′ FCL) 20′ FCL loaded with palletized drums of Dilute Sulfuric Acid Veterinary Grade API, securely braced, labeled, and sealed for transport.
    Shipping Dilute Sulfuric Acid Veterinary Grade API is shipped as a corrosive hazardous material: UN2796, Class 8, PG II/III as applicable. Use UN-approved acid-resistant packaging, correct labels/placards, SDS, and dangerous goods documentation. Keep upright, sealed, cool, dry; segregate from bases, metals, cyanides, sulfides. Follow IATA/IMDG/ADR and carrier rules.
    Storage Store in tightly closed, corrosion-resistant containers under cool, dry, well-ventilated conditions away from sunlight, heat, and ignition sources. Segregate from bases, oxidizers, reactive metals, cyanides, and sulfides. Use secondary containment and appropriate PPE. Maintain labeled inventory; avoid freezing or extreme temperatures. Follow manufacturer/safety data sheet requirements for veterinary-grade API and final dosage forms. Inspect regularly for leaks or container degradation.
    Shelf Life Typically 24 months from manufacture when stored in tightly closed, original containers, away from heat, light, moisture, and incompatible materials.
    Application of Dilute Sulfuric Acid Veterinary Grade API for Tablets / Injections / Capsules / Powders / Granules / Premix / Solutions

    In aqueous oral solution and drench manufacture, the veterinary-grade dilute sulfuric acid API is metered into the compounding vessel after the active pharmaceutical ingredient has been fully solubilised and the batch has been cooled to 20–25 °C. The addition rate is controlled at 0.5–2.0 L/min per 1000 L batch volume using a peristaltic pump with PTFE-lined or Viton tubing to avoid local pH overshoot at the dosing point. Because dissolved veterinary actives often carry amino, imidazole, or carboxylate moieties, the ionic form and resulting solubility at final pH determine whether the solution remains clear or forms free-base precipitate. A pH probe calibrated with NIST-traceable buffers at pH 1.68 and 4.01 is used to confirm that the final batch pH is within ±0.05 pH units of the registered specification. When sulfate ions are required for salt formation or counterion control, the substance is quantified as sulfate by ion chromatography with conductivity detection against a certified sulfate reference solution. Alkaline buffer species such as sodium bicarbonate or sodium carbonate release carbon dioxide on contact with the acid; the vessel must be vented and pH adjustment sequenced before buffer addition to prevent foam overflow and batch loss. The dilute acid is transferred from closed stainless steel day tanks equipped with double mechanical seals, and transfer lines are flushed with purified water after each use to prevent dried acid films from accumulating in dead legs.

    What Limits Acid Dosing Accuracy in Medicated Drinking Water and Soluble Powder Reconstitution?

    Because drinking water medication systems dilute stock solutions at fixed ratios, often 1:100 to 1:200, the acid demand of the source water determines the final pH after in-line mixing. Bicarbonate alkalinity above 250 mg/L CaCO₃ consumes acid and shifts the pH upward, requiring titration of the raw water before batch preparation. For water-soluble powders containing veterinary actives such as tetracycline or sulfonamide salts, pre-acidified reconstitution at pH 2.5–3.5 reduces oxidative degradation and improves solubility, but the acidified solution must be used within 6 to 24 hours depending on the active substance stability monograph. Dosing accuracy is validated by in-line pH sensors with automatic temperature compensation and calibrated against USP <791> potentiometric pH. The stock solution is prepared in high-density polyethylene or 316L stainless steel tanks; carbon steel and aluminium are incompatible below pH 4. Daily two-point buffer calibration at pH 1.68 and 4.01 is required to correct for sensor drift caused by dissolved carbon dioxide outgassing in closed lines. The following control points apply to acidified drinking water and reconstituted soluble powder systems.

    Control pointMethod or standardTypical acceptance rangeEquipment/technique
    Raw water alkalinityPotentiometric titration with 0.1 N HCl<250 mg/L CaCO₃Auto-titrator
    Stock solution pHUSP <791> / Ph. Eur. 2.2.32.5–3.5In-line pH sensor with ATC
    Acid addition rateGravimetric calibration±2% of setpointPeristaltic pump
    Reconstituted solution assayHPLC per registered methodAssay loss <10% over target use periodRefrigerated dosing tank

    Precipitation Boundaries Are Determined by Titration Curves, Not Nominal pH Alone

    Precipitation risk in aqueous injectable formulations is governed not by the nominal pH alone but by the titration curve of the dissolved veterinary active substance. Weak base drugs converted to hydrochloride or sulfate salts exhibit minimum solubility at pH values close to the isoelectric point; moving the pH downward with dilute sulfuric acid can increase solubility, but the sulfate anion itself may form sparingly soluble salts with calcium, barium, strontium, or lead if residual metals are present from tubing or stopper leachables. Manufacturing lines for injectable solutions follow USP <1> Injections requirements and terminal sterilisation where possible. The acid is added to Water for Injection meeting USP <645> conductivity limits in a closed stainless steel dosing loop, and the pH is adjusted within a range specified by the formulation. A pH outside that range by even 0.1 unit can change the fraction of un-ionised base, alter membrane permeability, and modify syringeability due to viscosity and precipitation. Post-addition 0.22 μm filtration is performed with polyethersulfone membrane filters because nylon membranes may hydrolyse below pH 2.5; filter integrity is tested by bubble point according to the filter manufacturer. Visible particulates are inspected under USP <790>. Chloride-containing additives are not combined with sulfuric acid in the same concentrate because mixed acid vapours accelerate corrosion of 316L vapour spaces. The sequence of acid addition, pH adjustment, filtration, and nitrogen overlay must be defined in the batch record because residual oxygen accelerates oxidative degradation of acid-sensitive actives. Published data for this specific configuration is limited when formulation-specific solubility boundaries are not declared in the registered dossier.

    When Sulfate Ion Migration Influences Granule Hardness and Disintegration Time

    When a dilute sulfuric acid solution is used as a granulating liquid in a high-shear wet granulation process for tablets or capsules, the final granule characteristics depend on the neutralisation reaction between the acid and the basic excipients. In a 300 L high-shear mixer with impeller tip speed of 8 m/s and chopper speed of 1500 rpm, the acid is sprayed at 2–5% of dry powder mass over 3–6 minutes. If the formulation contains calcium carbonate or dicalcium phosphate, carbon dioxide evolution creates intragranular pores that reduce granule tensile strength and increase disintegration time. The sulfate anion can migrate to the granule surface and recrystallise during fluid-bed drying at 50–60 °C, forming surface bridges that raise friability. Granules intended for capsule filling are milled through a 1.0 mm screen and blended with lubricant. The release profile is checked using USP <711> dissolution test, while disintegration is checked using USP <701>. A formulation with final granule moisture content above 2.5% may exhibit cap crushing due to die wall friction during compression. Batch-to-batch variation is reduced by controlling acid addition rate and by pre-blending acid with 10% of the diluent before spraying. Because basic disintegration agents such as sodium starch glycolate can neutralise residual acid and delay pH-sensitive release, the acidified granules are discharged only after the wet mass passes an in-process pH spot test with a flat-tip surface electrode.

    Feed acidifier premixes containing dilute sulfuric acid are produced on continuous paddle mixers where the acid is sprayed onto a mineral carrier such as precipitated silica or calcium sulfate. The carrier must absorb the acid without releasing free liquid, and the final premix moisture is held below 8% to prevent caking. A horizontal paddle mixer with a working volume of 500 kg and shaft speed of 40–60 rpm provides shear sufficient to distribute the acid over the carrier in 5–10 minutes. Batch homogeneity is assessed by sampling from ten defined points and measuring pH after a 1:10 aqueous dilution, with relative standard deviation below 5% as an internal control. Acidified premixes are incorporated into complete feed at 0.5–3.0 kg/tonne before pelleting; the pellet mill conditioner temperature is limited to 70 °C because higher temperatures increase the vapour pressure of residual acid and may corrode the conditioner wall. The intended technical function is to lower feed and digesta pH; efficacy in target species must be supported by registration dossiers under the applicable feed additive regulation such as EU Regulation 1831/2003. The effect depends on dietary buffering capacity as measured by acid-binding capacity at pH 4 with hydrochloric acid titration, not on acid inclusion alone.

    Corrosion Control and Cross-Contamination Limits in Multi-Species Acidified Product Lines

    Ribbon blender discharge samples collected after 2, 5, and 10 minutes of mixing are used to establish the mixing endpoint for each new carrier lot, because carrier particle size shifts alter acid absorption capacity. A single-wash 1.0% sodium carbonate rinse is insufficient for neutralisation when dried acid crystals form in blender corners; 316L stainless steel surfaces develop rouge layers and require passivation per ASTM A967. Cross-contamination into non-acidified premixes is controlled by measuring the pH of the 10-mL rinse water from a surface swab. Lines producing injectable-grade solutions are segregated from feed acidifier lines because the cleaning validation acceptance limits for residues differ by three orders of magnitude. The cleaning validation protocol adopts carryover limits expressed as residual active moiety, not visible cleanliness alone. Operators verify that acid transfer hoses are labelled with separate colour-coded tags for injectable and feed-grade service, and that pH electrodes are stored in 3 M potassium chloride solution after each shift to maintain response slope. Equipment contact surfaces are inspected for pitting at semiannual intervals using boroscope examination of tank welds and pump casings; replacement is specified when surface roughness exceeds 0.8 μm Ra.

    Free Quote

    Competitive Dilute Sulfuric Acid Veterinary Grade API for Tablets / Injections / Capsules / Powders / Granules / Premix / Solutions prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618963613625 or mail to sales10@ascent-petrochem.com.

    We will respond to you as soon as possible.

    Tel: +8618963613625

    Email: sales10@ascent-petrochem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Described herein is dilute sulfuric acid veterinary grade API intended for incorporation into tablets, injections, capsules, powders, granules, medicated premix, and oral solutions. The material is supplied as an aqueous solution at two concentrations: a 10.0% w/w grade designated in this text as DSA-VET-10 and a 35.0% w/w grade designated DSA-VET-35. The 10.0% w/w solution corresponds to the strength range described by the current United States Pharmacopeia Dilute Sulfuric Acid monograph when the assay is expressed as 9.5–10.5 g/100 mL. The 35.0% w/w grade is a non-compendial industrial concentration that is used where reduced water transport is required in oral premix and granulation operations. In all dosage forms the material acts as a non-volatile pH modifier and sulfate counterion source; its suitability is route-specific because injectable applications impose endotoxin and particulate controls that are not required for every oral premix or granulation use. The same chemical identity does not imply interchangeable use. Injectable application requires low bacterial endotoxin, sub-visible particulate control under USP <788>, and sterile filtration, while an oral premix can tolerate higher bioburden but cannot tolerate elevated chloride because of corrosion and drug-excipient interaction risk.

    What Specifications and Test Methods Apply to Injectable and Oral Grades?

    The compendial control framework for the 10.0% w/w material is based on titration, density, clarity, impurity limits, and, for parenteral grades, bacterial endotoxins and bioburden. Assay is performed by acid-base titration with carbonate-free sodium hydroxide using a combined pH electrode. The sample is diluted with carbon dioxide-free water and titrated to the second equivalence point near pH 6.8–7.2. Density at 20 °C is measured by oscillating U-tube according to ASTM D4052-22; typical values are 1.0661 g/cm³ for the 10.0% w/w solution and 1.2599 g/cm³ for the 35.0% w/w solution. These values are release checks rather than quantitative assay results. pH is not used as a final release specification for the API because the electrode response is non-linear in concentrated acid, but final product pH is controlled under USP <791>.

    ParameterDSA-VET-10DSA-VET-35Reference method
    Sulfuric acid assay9.5–10.5 g/100 mL33.5–36.5% w/wTitrimetric, current USP-NF
    Density at 20 °C1.0661 g/cm³1.2599 g/cm³ASTM D4052-22
    AppearanceClear, colorless, syrupy liquidClear, colorless, syrupy liquidVisual inspection
    Chloride≤0.005%≤0.005%USP <221> / Ph. Eur. 2.4.4
    Arsenic≤0.0001% (1 ppm)≤0.0001% (1 ppm)Ph. Eur. 2.4.2
    Heavy metals, expressed as Pb≤0.001% (10 ppm)≤0.001% (10 ppm)Ph. Eur. 2.4.8
    Iron≤0.001% (10 ppm)≤0.001% (10 ppm)Spectrophotometric limit test
    Residue on ignition≤0.005%≤0.005%Compendial gravimetric method
    Bacterial endotoxins, injectable grade<0.25 EU/mLNot specifiedUSP <85> / Ph. Eur. 2.6.14
    Total aerobic microbial count, oral grade<100 CFU/mL<100 CFU/mLUSP <61> / Ph. Eur. 2.6.12

    Clarity and color are checked against reference suspensions or measured at 430 nm using a spectrophotometer; acceptance is typically no more than 10 NTU for injectable grade, though the specific limit depends on the finished product. Published data for this specific configuration is limited. The 35.0% w/w grade is generally not suitable for direct parenteral use unless the manufacturer performs additional endotoxin reduction, particulate filtration, and batch-specific confirmation. Chloride above 0.005% creates risk of pitting in 316L stainless steel at elevated sterilization temperatures. Iron and heavy metals can catalyze oxidation of antioxidants, vitamins, and unsaturated excipients in premixes and oral solutions; therefore their control is more stringent than in technical-grade acid.

    Storage and transfer of the 35.0% w/w material require a ventilated stainless steel or high-density polyethylene system. Because dilution enthalpy is strongly exothermic, the acid must be added to water with continuous agitation; reverse addition may cause localized boiling and acid aerosol. Transfer lines for injectable use are typically 316L stainless steel with internal surface finish Ra ≤0.6 µm per ASME BPE and are passivated before use. Contact with hypochlorite sanitizers, sodium hydroxide, or carbon steel is not permitted because of exothermic reaction or corrosion. Containers should be kept closed at 5–30 °C; at low ambient temperatures, the 10.0% w/w solution may freeze near −2 °C. Opened containers should be retested for density and bioburden before use, particularly when the material will enter injectable processing.

    When Tablet Granulation and Powder Blending Require Sulfate Acidification

    In tablet manufacturing, the 10.0% w/w acid is often used as a binder-fluid acidulant during wet granulation of weakly basic active substances. It converts the base to a sulfate salt in the granule, which can improve compactability and dissolution rate. The acid is introduced into a high-shear granulator through a peristaltic pump and nozzle at a rate of 2–5 kg/min for a 600 L bowl, but the actual rate is dictated by the formulation’s liquid-to-solid ratio and the main impeller speed. A processing boundary exists at the addition point: if the acid is added without adequate chopper action, local liquid saturation can exceed 0.85 and cause agglomerate growth beyond the target particle size. Batch records from production of buffered veterinary granulations show that acid binder temperature is maintained at 18–22 °C; higher temperatures lower the binder viscosity and change wet mass rheology. Loss on drying is typically controlled to 2.0–3.5% by USP <731> after tray drying at 50–60 °C.

    The sulfate counterion is non-volatile, so it remains in the dried granule; this is a deliberate formulation feature but differs from hydrochloric acid, which may be partially lost during drying. Tablet compression on a rotary press may require target hardness 80–120 N; acid granulations containing sulfate salts often show brittle fracture, and precompression force must be adjusted to prevent capping. Disintegration is tested by USP <701>. Use of sulfuric acid in a carbonate-containing formulation is contraindicated because sulfate reacts with carbonate to generate carbon dioxide, causing loss of granule integrity and variable tablet mass. For water-sensitive actives, the 35.0% w/w grade permits lower water addition, but the higher acid strength demands closer control of nozzle atomization to avoid localized charring of starch, cellulose, or maltodextrin binders.

    For oral powders, granules, medicated premix, and capsules, the acid is typically sprayed onto a silica or maltodextrin carrier in a ribbon blender with 316L contact surfaces. Calcium carbonate carriers are not used because sulfate reacts to form calcium sulfate and carbon dioxide, causing caking and loss of flow. Mixing time is determined by uniformity testing; a typical sampling plan uses 10 thief probe samples and relative standard deviation ≤5.0% for acid content. In liquid-filled hard capsules, the acid is used at low concentration in a non-aqueous vehicle after compatibility evaluation at 40 °C/75% RH for 6 months; published data for this specific configuration is limited. Oral solutions are usually adjusted to pH 2.5–4.0 with USP <791> verification; the acid is fed through a static mixer using a proportional pH control loop to avoid overshoot. Injectable forms use the 10.0% w/w grade only when the intended active is compatible with sulfate. A typical sequence for a small-volume parenteral is: dissolve the active in Water for Injection, add the acid through a dip tube with agitation at 150–250 rpm, adjust pH to the target range, then add tonicity agent and dilute to final volume. The solution is filtered through 0.22 µm membrane filters before filling and sterilized by terminal steam sterilization or aseptic filtration. The non-volatile character of sulfuric acid prevents pH drift during terminal steam cycles in vented vessels; this is a key process advantage over hydrochloric acid.

    Compatibility Boundaries and Comparative Acidulant Selection

    The primary operational boundary is sulfate precipitation. Calcium sulfate has limited solubility in water; published solubility for gypsum at 20 °C is approximately 2.5 g/L, but the value is reduced by ethanol or polyols present in some parenteral vehicles. Consequently, dilution and mixing orders must be fixed, and the maximum hold time before filtration should be validated; a common in-process limit is 2 hours when calcium is present. The second boundary is materials of construction. Dilute sulfuric acid corrodes carbon steel and can attack 304 stainless steel at elevated temperatures; for injectable processing, 316L, PVDF, PFA, and borosilicate glass are accepted contact materials. Elastomeric seals should be ethylene propylene diene monomer or silicone; natural rubber can deteriorate rapidly at pH below 1.0.

    AcidulantKey pKaVolatilityCounterion boundary
    Sulfuric acid 10.0% w/wpKa1 −3, pKa2 1.99Non-volatileSulfate precipitates calcium, barium, and strontium
    Hydrochloric acid 10.0% w/wpKa −7Volatile chlorideChloride promotes pitting corrosion on stainless steel
    Phosphoric acid 10.0% w/wpKa1 2.15, pKa2 7.20, pKa3 12.35Non-volatileCalcium phosphate precipitation at higher pH
    Citric acid 10.0% w/wpKa1 3.13, pKa2 4.76, pKa3 6.40Non-volatile organicChelates calcium; organic carbon increases microbial risk

    Compared with hydrochloric acid, dilute sulfuric acid has lower vapor pressure and does not build chloride stress-corrosion conditions in 316L autoclaves. Compared with phosphoric acid, it provides stronger initial pH depression per unit volume but less buffering near neutral pH. Compared with citric acid, it leaves no organic carbon source and therefore reduces the risk of microbial spoilage in oral solutions; however, citrate is preferred when calcium-containing formulations require chelation. The specification difference between veterinary API grade and technical-grade sulfuric acid is not concentration alone. Technical material may contain iron, chloride, and suspended solids that interfere with titration endpoints, catalyze oxidation of vitamins or antioxidants in premixes, and generate visible particles in injectable solutions. The absence of endotoxin testing in technical grades makes them unsuitable for parenteral or ophthalmic preparations. Published data for this specific veterinary-grade configuration is limited, but the quality burden is higher because the material enters the drug product rather than a cleaning or pH-neutralization operation.

    Top