    Specifications
    HS Code 784668
    Product Name Xylene
    Grade Electronic/EL Grade
    Chemical Formula C8H10
    Cas Number 1330-20-7
    Molecular Weight 106.17 g/mol
    Appearance Clear colorless liquid
    Purity As Xylene Isomers ≥99.9%
    Water Content ≤50 ppm
    Evaporation Residue ≤1 ppm
    Acidity ≤10 ppm (as Acetic Acid)
    Color Apha ≤10
    Refractive Index At 20 C 1.4940 - 1.4970
    Density At 20 C 0.860 - 0.870 g/cm³
    Boiling Range 138 - 144 °C
    Flash Point 25 °C
    Metal Impurities Each element ≤1 ppb

    As an accredited Xylene Electronic/EL Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Xylene Electronic/EL Grade is packaged in 200L HDPE drums with nitrogen blanket, ensuring solvent purity, safe handling, and minimal contamination risk.
    Container Loading (20′ FCL) 20′ FCL loading of Xylene Electronic/EL Grade: secure drums on pallets, label hazmat, ventilate, and block/bracing for safe transport.
    Shipping Xylene Electronic/EL Grade ships as a flammable, high-purity solvent in sealed, corrosion-resistant containers. Transport requires ground or sea freight only, with proper hazard labeling and documentation. Avoid air shipment. Store upright, away from ignition sources, and follow all applicable dangerous goods regulations during handling and delivery.
    Storage Store Xylene Electronic/EL Grade in tightly sealed, approved containers in a cool, dry, well-ventilated area away from direct sunlight, heat, and ignition sources. Keep segregated from oxidizers and incompatible materials. Use grounded containers and secondary containment to prevent spills. Ensure proper labeling, fire suppression, and access to emergency eyewash equipment.
    Shelf Life Xylene Electronic/EL Grade has a shelf life of 2–3 years when stored sealed, cool, dry, and away from light and ignition sources.
    Application of Xylene Electronic/EL Grade

    In 300 mm coater/developer tracks, EL-grade xylene is metered through dedicated edge bead removal nozzles positioned over the wafer bevel. Mixed xylene fractions with boiling points from 137 °C to 144 °C dissolve cyclized polyisoprene negative resists and partially swell novolac-positive resist edge deposits before thermal stabilization. Delivery lines are fabricated from 316L stainless steel with PTFE-coated internals; point-of-use filtration at 0.05 µm reduces particle addition during top-side and backside rinse. Xylene is not universally interchangeable with PGMEA because its lower polarity slows dissolution of heavily esterified positive resists; rework dwell time may rise by a factor of 2–3 when PGMEA is replaced at 23 °C. Moisture control is process-critical: free water above 200 mg/kg by ASTM E1064 can generate amine-bearing defects in chemically amplified resists. Xylene-based developers for negative-tone resists require the same low-metal profile; sodium and potassium are controlled below 20 ng/g by ICP-MS to avoid gate oxide contamination in sub-50 nm node flows. Bulk storage under nitrogen with 0.2 µm vent filtration is standard. Typical edge bead removal formulations blend xylene with n-butyl acetate at 30–70 wt%, adjusted to match coater cup exhaust and wafer rotation speed.

    Typical EL-grade mixed xylene acceptance control matrix
    Control parameterAcceptance windowMethod
    Water content200 mg/kgASTM E1064
    Nonvolatile residue10 mg/kgASTM D1353
    Acid wash colorNo darker than referenceASTM D848
    Metals by ICP-MS50 ng/g for Na, K, Fe, Cu, Ni; ≤ 10 ng/g for Ca, Mg, ZnICP-MS after dry-down
    Particles ≥ 0.5 µm25 particles/mLOptical liquid particle counter

    When Do Solder Mask Formulators Substitute EL-Grade Xylene for Glycol Ether Acetate?

    Xylene EL grade enters PCB fabrication when thermally curable epoxy-acrylate solder masks require viscosity adjustment without reducing photoinitiator concentration. The solvent is added at 3–10 wt% to screen-print pastes; higher additions cause smudging and incomplete wedge filling on 35 µm copper features. Mixing uses low-shear planetary dispersion at 20–30 rpm for 10–15 min to avoid air entrapment. The aromatic solvent interacts with bisphenol A epoxy oligomers, lowering paste viscosity from 180–220 Pa·s to 80–120 Pa·s at 25 °C when 5 wt% is added, measured by Brookfield CP at 5 rpm. After screen printing, the prebake profile must evaporate xylene before UV or thermal cure; residual solvent above 0.5 wt% in a 75 µm wet film can create blistering during convective cure at 150 °C. Compliance with IPC-SM-840C requires the cured deposited film to pass thermal shock cycling and IPC-TM-650 2.3.25 ionic cleanliness testing. Xylene is incompatible with waterborne solder mask systems because phase separation occurs at additions above 2 wt%; this limits its use to solvent-borne formulations.

    Oligomeric Polyimide Precursor Diluents in Roll-to-Roll Casting

    Flexible circuit manufacturers use EL-grade xylene as a co-solvent for polyamic acid ester systems during wet-cast polyimide film production. In roll-to-roll coaters, xylene raises solvent boiling point and promotes uniform drying across 25–50 µm wet films. The solvent is blended with N-methyl-2-pyrrolidone or dimethylacetamide at 10–35 wt%; xylene-rich formulations reduce drying-tower defects but retard imidization if the substrate exits the first zone below 120 °C. Sodium and potassium in xylene above 20 ng/g each cause measurable leakage-current degradation in cured polyimide layers, so each lot must undergo ICP-MS after dry-down. Coating solution viscosity at 23 °C is adjusted to 1,000–5,000 mPa·s by changing the solvent ratio rather than monomer loading, preserving polymer molecular weight. The coating head is a slot die with a 0.2 mm lip gap; cross-web solvent variation must remain below 2% to avoid anisotropic dielectric constant. Azeotropic removal of imidization water by xylene between 135 °C and 145 °C reduces polyimide cure time in nitrogen-circulated ovens. Published data for the cross-web tolerances of this specific EL-grade xylene-polyamic acid ester configuration are limited; coaters prequalify each lot by pilot slot-die trial before roll changeover.

    EL-grade xylene is employed in TFT-LCD array fabs for removal of organic residue from shadow-mask aligner tooling and from carrier plates after plasma-enhanced chemical vapor deposition cleaning cycles. The solvent is applied in ultrasonic baths at 30–45 kHz, then rinsed with isopropyl alcohol and dried with filtered nitrogen. Stainless steel immersion tanks require continuous 0.1 µm recirculation because particle counts above 25 particles/mL at 0.5 µm optical liquid particle counter transfer to glass substrates. Xylene shows high solubility for fluorinated etch by-products and vacuum-pump oils but is not applied directly to active-matrix backplanes because residual hydrocarbon can shift threshold voltage in amorphous silicon thin-film transistors. Equipment operators limit immersion time to 5–10 min for anodized aluminum fixtures; extended contact at 40 °C degrades seal elastomers and extracts plasticizers from EPDM gaskets. The aromatic solvent evaporates more slowly than acetone, so a post-clean hot-air knife at 60 °C is used to prevent drying marks on shadow masks.

    If Xylene EL-Grade Replaces Chlorinated Solvents in Relay Degreasing

    High-reliability military and aerospace electronic components are dry-cleaned with EL-grade xylene before seam sealing. The solvent removes hydrocarbon-based stamping oils from nickel-iron alloy relay cans and contact surfaces without attacking alkyd varnishes used on coil windings. Vapor-phase degreasing is run at 140–145 °C in equipment with external heating coils and a freeboard ratio above 1.0 to reduce solvent loss. Because mixed xylene has a flash point near 25 °C by ASTM D56 Tag closed cup, heated immersion requires inert-gas blanketing and oxygen monitoring below 5% by volume. Impurity control is the limiting acceptance criterion: chloride residues above 5 mg/kg can initiate electromigration between adjacent gold-plated contact pads when condensation occurs. EL-grade xylene meeting a purchase specification typically records total metals below 50 ng/g by ICP-MS and nonvolatile residue below 10 mg/kg by ASTM D1353. The cleaning line uses vapor degreaser, first rinse, second rinse, and liquid spray lance. Liquid xylene at elevated temperature is incompatible with nitrile and butyl rubber seals; PTFE or fluorocarbon elastomer contact surfaces are specified.

    For selective robotic dispense of solvent-borne silicone conformal coating, EL-grade xylene is added at 5–15 wt% to reduce viscosity to 35–60 mPa·s; the coated assembly rests at 25 °C for 10 min before thermal cure to prevent solvent entrapment.

    Free Quote

    Competitive Xylene Electronic/EL Grade prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615365186327

    Email: admin@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Xylene Electronic/EL Grade is a high-purity aromatic hydrocarbon solvent supplied as a mixed-isomer stream under CAS 1330-20-7. The term Electronic/EL Grade does not denote a distinct molecular species; it identifies a controlled impurity envelope intended for semiconductor, flat-panel display, and precision cleaning operations. The material is composed primarily of m-xylene, p-xylene, o-xylene, and ethylbenzene, with the ethylbenzene fraction typically retained because its boiling point is close to the xylene isomers and separation is not economical for all electronic applications. Typical assay by capillary gas chromatography is ≥99.9% for the sum of xylene isomers and ethylbenzene, with the remaining fraction consisting of toluene, cumene, and aliphatic hydrocarbons. Physical constants include molar mass 106.16 g/mol, boiling range 137–144 °C at 760 mmHg, density 0.862–0.875 g/cm³ at 20 °C, flash point 25–32 °C by closed cup, and vapor pressure 0.8–1.2 kPa at 20 °C. The product is supplied in 4-L glass bottles with PTFE-lined caps, 20-L stainless steel cans, and 200-L epoxy-phenolic lined drums; semiconductor wet benches typically receive 200-L drums under nitrogen pad with point-of-use filtration. Certificate-of-analysis documentation for Electronic/EL Grade is usually more detailed than for reagent-grade material, including metal and particle counts that are not always specified for ACS-grade xylene.

    Because xylene is a commodity aromatic produced by catalytic reforming and aromatic extraction, the isomer ratio is set by the source naphtha and reformer severity. A typical mixed xylene may contain 40–60% m-xylene, 10–20% p-xylene, 10–25% o-xylene, and 10–25% ethylbenzene. Electronic/EL Grade does not isolate para-xylene or meta-xylene; users requiring isomer-pure solvent must specify p-xylene or m-xylene separately. The presence of ethylbenzene can affect solvency, evaporation, and oxidation behaviour, but it is not a defect in electronic-grade mixed xylene. This composition is determined by gas chromatography using ASTM D7504 and is reported on the certificate of analysis.

    How Does Electronic/EL Grade Xylene Differ from Reagent-Grade and Technical-Grade Mixed Xylenes?

    The distinction is not primarily isomer composition. Electronic/EL Grade and lower-purity grades may contain the same aromatic backbone. The difference lies in controlled impurities that affect wafer-level defects: water, non-volatile residue, acidity, chloride, sulfur, metals, and particles. Reagent-grade xylene meeting ACS specifications is acceptable for analytical extraction and general laboratory use, but its water and residue limits are broader and its trace-metal content is not controlled to semiconductor levels. Technical-grade xylene is commonly associated with higher odor, higher sulfur, and variable distillation behavior that can produce organic films after drying. The comparison in Table 1 is drawn from public specifications for ACS reagent grade and from typical industrial technical-grade ranges; Electronic/EL Grade values are supplier-dependent and may be tighter for advanced nodes.

    ParameterElectronic/EL GradeReagent/ACS GradeTechnical Grade
    Assay (xylenes + ethylbenzene), GC≥99.9%≥98.5%95–99%
    Water, Karl Fischer≤100 mg/kg≤200 mg/kgnot controlled
    Non-volatile residue≤5 mg/kg≤20 mg/kg≤50 mg/kg
    Acidity≤0.005 meq/g≤0.005 meq/gnot specified
    Color APHA≤10≤10≤20
    Metals by ICP-MS≤100 µg/kg totalnot specifiednot specified
    Particle count ≥0.5 µmcontrolled per SEMI C8not specifiednot specified

    Distillation range is narrower for electronic grade, with dry point controlled to reduce high-boiling residues. Technical-grade xylene may have a wider boiling range and include heavier aromatic hydrocarbons. The narrower cut limits the formation of drying films on polished surfaces. Sulfur compounds in technical-grade material may include thiophenes and mercaptans; electronic-grade hydrodesulfurization and adsorptive treatment reduce sulfur below 1 mg/kg and lower the potential for surface sulfide formation. Metal contamination sources include distillation columns, transfer piping, drum linings, and reusable containers; electronic-grade supply chains use dedicated stainless steel or lined equipment and filtered filling to limit these contributions.

    Within semiconductor lithography and packaging operations, Xylene Electronic/EL Grade serves as a solvent for edge bead removal, photoresist stripping formulations, epoxy and polyimide carrier systems, and precision cleaning of deposition masks and stencils. The solvent is applied in single-wafer tools or immersion baths; when used as an edge bead remover, it is dispensed through fluoropolymer nozzles at the wafer edge after resist spin-up. Its solvency for novolak and polyhydroxystyrene resists allows the removal of resist edges before bake, reducing edge bead height and flake generation. In immersion stripping, the material swells cross-linked photoresist and facilitates delamination when used with ultrasonic or megasonic agitation. For metal stencils and printed circuit board tooling, EL-grade xylene removes rosin-based flux residues and some epoxy adhesives; however, published data for extraction rates on high-temperature polyimide residues is limited. Xylene has Hansen solubility parameters δD 17.8 MPa½, δP 1.0 MPa½, and δH 3.1 MPa½, which place it near novolak, polystyrene, and many epoxy resins. This dispersive interaction with aromatic polymers supports resist edge bevel cleaning and epoxy adhesive thinning.

    In production wet benches, bath life management is a practical constraint. Xylene recycled through distillation can accumulate high-boiling photoresist oligomers and metal complexes; without fractional distillation to a 150 °C dry point, residue levels can exceed 5 mg/kg after multiple cycles. Point-of-use filters must be rated for aromatic hydrocarbons; polypropylene and PTFE cartridges are generally compatible, while natural rubber and EPDM seals may swell and release extractables. In high-volume packaging tools, two failure modes are observed when lower-purity xylene is substituted unintentionally: redeposition of non-volatile residues on heated stencils and drift in ultrasonic bath conductivity caused by water uptake. These failures are not typically observed with Electronic/EL Grade if point-of-use filtration and nitrogen blanketing are maintained.

    Metals, Particulate, and Non-Volatile Residue Limits Are the Defining Specification Envelope

    For semiconductor-grade materials, the specification envelope is tighter than reagent or technical grades. Table 2 lists common supplier certificate-of-analysis bands for Xylene Electronic/EL Grade; exact guarantees vary by supplier and semiconductor node. The values are not a single universal standard, but they are representative of publicly available product certifications aligned with SEMI C8. Water is controlled because residual water in xylene can cause corrosion of copper interconnects, promote photoresist interfacial defects, and alter spin coating rheology. Chloride and sulfur are monitored because they can form acid species during combustion or surface reactions. Metal limits are set at micrograms per kilogram levels because even trace cations can alter device performance in gate oxide and interconnect layers.

    ParameterTest method / basisCommon specification band
    Assay (xylenes + ethylbenzene)ASTM D7504≥99.9%
    WaterASTM E1064≤100 mg/kg
    Non-volatile residueASTM D1353≤5 mg/kg
    AcidityASTM D847≤0.005 meq/g
    ChlorideASTM D5194≤1 mg/kg
    SulfurASTM D4045≤1 mg/kg
    Total metalsICP-MS≤100 µg/kg
    Particle count ≥0.5 µmSEMI C8≤100 particles/mL
    Color APHAASTM D1209≤10
    Distillation rangeASTM D850137–144 °C

    Individual metal limits for sodium, potassium, calcium, iron, copper, zinc, aluminium, and manganese may be set below 10 µg/kg for advanced nodes; published data for this specific configuration is limited. Lot-to-lot variation in metal impurities can also be influenced by reusable drum cleaning and transfer lines, so supplier lot-specific certificates should be reviewed before qualification.

    Incoming material qualification for Xylene Electronic/EL Grade typically includes gas chromatography with flame ionization detection for assay, coulometric Karl Fischer titration for water, evaporation under controlled airflow for non-volatile residue, and ICP-MS for trace metals after solvent evaporation and acid digestion. Particle counts are measured by laser particle counters on filtered samples; bottles and drums are sampled under cleanroom flow or a laminar hood to avoid ambient particle contamination. Measurement repeatability for metal impurities near 10 µg/kg can be affected by sample introduction and lab atmosphere; suppliers typically use cleanroom-compatible digestion and internal standards to reduce matrix effects.

    Storage and Material Compatibility Boundaries in Production Use

    Storage requires closed-top vessels with inert gas blanketing and bonding/grounding. Xylene is a flammable liquid with lower flammable limit 1.0 vol% and upper flammable limit 7.0 vol%; process areas must maintain vapor concentrations below 10% of LFL. Avoid contact with strong oxidizers such as nitric acid and perchlorates, and do not blend with amine-based stripper concentrates unless compatibility testing is complete, because exothermic reactions or salt precipitation may reduce bath life. Use PTFE, PVDF, or 316L stainless steel for wetted components; EPDM and Buna-N gaskets are not recommended for continuous exposure. Pre-drying of process lines is required when relative humidity exceeds 60% to avoid water uptake into the solvent. If the solvent is exposed to ambient air for extended periods, it can absorb moisture and form trace oxidation products, so headspace should be blanketed with dry nitrogen. Drum pumps should be explosion-proof and grounded; transfer lines should be dissipation-rated for low-conductivity hydrocarbons. Regulatory classification includes flammable liquid Category 3 under GHS, acute toxicity Category 4, and aspiration toxicity Category 1. Xylene is registered under EU REACH and is subject to VOC emission controls in semiconductor fabs; it is not an intentional RoHS substance and is not a food-contact material.

    When Xylene Electronic/EL Grade Replaces Acetone or PGMEA in Cleaning Baths, Drying and Wastehandling Shift

    Replacement of acetone or propylene glycol monomethyl ether acetate (PGMEA) with xylene changes evaporation rate, surface tension, and waste classification. At 20 °C, xylene vapor pressure is 0.8–1.2 kPa, compared with 24 kPa for acetone and 0.4 kPa for PGMEA. Drying time in single-wafer tools therefore increases relative to acetone and is closer to PGMEA. Surface tension of xylene is 28.5–30.1 mN/m, which is higher than acetone at 23.7 mN/m and similar to PGMEA at 27.5 mN/m. The higher boiling range 137–144 °C reduces evaporative cooling on spin-clean tools but leaves a longer residence tail on heated chucks. Water solubility in xylene is ≤0.02% at 20 °C, so water entering the bath separates rather than dissolving; this can create microemulsion droplets if surfactants are present. Wastehandling shifts because xylene is a flammable liquid and a VOC; spent solvent must be segregated from aqueous acid waste streams to avoid two-phase hazards and to maintain distillation recovery. In vapor degreasers, xylene is not a direct substitute for chlorinated solvents such as perchloroethylene because of its lower boiling point and higher flammability; immersion and spray-under-inerting are preferred.