| HS Code | 349066 |
| Product Name | Xenon (Xe) Electronic/EL Grade |
| Chemical Formula | Xe |
| Cas Number | 7440-63-3 |
| Molecular Weight | 131.293 g/mol |
| Grade | Electronic/EL Grade |
| Purity | ≥99.999% (5N) |
| Appearance | Colorless gas |
| Odor | Odorless |
| Melting Point | -111.8 °C at 1 atm |
| Boiling Point | -108.1 °C at 1 atm |
| Density | 5.894 g/L at 0 °C and 1 atm |
| Specific Gravity | 4.56 (air = 1) |
| Solubility In Water | Approximately 0.63 g/L at 20 °C and 1 atm (slightly soluble) |
| Critical Temperature | 16.6 °C |
| Critical Pressure | 5.84 MPa |
| Moisture H2o Content | ≤1 ppm (typical) |
| Oxygen O2 Content | ≤1 ppm (typical) |
| Total Hydrocarbon Content | ≤0.5 ppm (typical) |
As an accredited Xenon (Xe) Electronic/EL Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Xenon Electronic/EL Grade is supplied in 50 L steel cylinders, 5.0 Nm³ fill, with CGA 580 outlet, 99.999% purity. |
| Container Loading (20′ FCL) | 20′ FCL for Xenon (Xe) Electronic/EL Grade: cylinders secured upright, protected, ventilation ensured, weight distribution balanced, full container load. |
| Shipping | Xenon (Xe) Electronic/EL Grade ships as a non-flammable, compressed gas in high-pressure cylinders, strictly adhering to DOT/UN transport regulations. Cylinders are secured upright with protective valve caps and labeled with hazard and purity documentation. Handling requires proper ventilation and leak checks to ensure safe delivery. |
| Storage | Store Xenon (Xe) Electronic/EL Grade as a compressed gas in high-pressure cylinders. Keep cylinders upright, secured, and in a cool, dry, well-ventilated area. Maintain temperature below 52°C (125°F) and away from ignition sources and incompatible materials. Protect valves with caps. Use proper leak detection and monitor oxygen levels to prevent asphyxiation. |
| Shelf Life | Shelf life is indefinite when stored in sealed, approved cylinders under proper conditions; gas remains stable. |
In flat-panel-display fabrication, low-temperature polysilicon thin-film transistors are produced by scanning a 308 nm XeCl excimer laser beam across a hydrogenated amorphous silicon layer, a process in which the xenon concentration in the laser gas mixture is the governing formulation variable rather than any downstream liquid or solid additive. The laser gas fill is a high-purity mixture containing xenon at 0.1 vol% to 0.5 vol%, hydrogen chloride at 0.05 vol% to 0.2 vol% as the halogen donor, and balance neon, held at a total fill pressure of 3 bar to 4 bar absolute. Gas-delivery hardware uses electro-polished 316L stainless steel manifolds, sub-ppb noble-gas purifiers, mass flow controllers calibrated for low-flow xenon/hydrogen chloride blends, and closed-loop halogen replenishment that compensates for chlorine depletion during high-repetition-rate operation; the laser enclosure is classified under IEC 60825-1:2014 Class 4, and the gas panel is validated against SEMI C3 moisture and particle thresholds by cavity ring-down spectroscopy and laser particle counting. Passivation of the gas panel with a neon/hydrogen chloride mixture at 10% above working pressure for 24 h to 72 h before first fill is normal practice to reduce initial chlorine consumption from passivated surfaces. On the production line, pulse-to-pulse energy stability is monitored by photodiode, and beam overlap between successive pulses is held at 95% to 98% with an energy density of 250 mJ/cm² to 400 mJ/cm² on the substrate. Process excursions above 0.5 vol% xenon shorten gas lifetime by accelerating deposition on the output coupler, while excursions below 0.1 vol% reduce pulse energy stability below the ±1% standard deviation required for uniform crystallization across a Gen 6 glass substrate. The terminal products are LTPS TFT backplanes for active-matrix OLED smartphone displays, notebook panels, and microdisplays.
Satellite electric propulsion systems consume xenon as a single-species propellant, so the addition-ratio requirement is expressed as a purity boundary rather than a blend concentration. The xenon feed must meet ISO 15859-13:2004 limits, with mission-specific procurement often tightening water to 0.5 ppmv and krypton to 5 ppmv because both species alter hollow-cathode ignition and discharge stability. Propulsion system integration follows ECSS-E-ST-35C. Ground support equipment evacuates the satellite propellant tank to 10-6 mbar before loading, and xenon is loaded into composite overwrapped pressure vessels at 150 bar to 300 bar. During operation, the pressure-regulation module delivers xenon to the anode flow controller at 1 bar to 3 bar differential, and mass flow is maintained at 5 mg/s to 30 mg/s for a 1 kW to 5 kW thruster. The flow is split between the anode and the hollow cathode, with the cathode typically receiving 10% to 20% of the total mass flow. Discharge voltage typically ranges from 200 V to 400 V, discharge current from 5 A to 20 A, and specific impulse from 1500 s to 2500 s. Acceptance testing occurs in high-vacuum chambers at 10-5 mbar or lower, where beam divergence, thrust, and cathode ignition repeatability are measured. Field failures during acceptance are most often associated with water ingress at propellant loading interfaces and with particulate contamination, which can shift the cathode keeper voltage and delay ignition. Terminal products include all-electric GEO communications satellites, LEO broadband constellation spacecraft, and interplanetary probes.
| Parameter | Representative control limit | Analytical method |
|---|---|---|
| Xenon purity | 99.9995 vol% minimum | GC-PDHID differential |
| Water | 0.5 ppmv maximum | CRDS |
| Oxygen | 1 ppmv maximum | GC-PDHID |
| Nitrogen | 2 ppmv maximum | GC-PDHID |
| Total hydrocarbons | 0.5 ppmv maximum | FID |
When semiconductor failure-analysis laboratories replace gallium liquid-metal ion sources with xenon plasma focused ion beam sources, the milling window for large-area package delayering expands from a few tens of micrometers to several hundred micrometers per session. The xenon feed is not a formulated mixture; it is 99.9995 vol% xenon supplied to the inductively coupled plasma source at a controlled flow of 5 sccm to 30 sccm. Beam acceleration is generally fixed at 30 kV, with current selectable from 0.1 µA to 2.5 µA, enabling high-throughput cross-sectioning without gallium implantation. Tool safety compliance follows SEMI S2, and section preparation follows ASTM E3-11. The source is driven by an RF power supply that maintains an inductively coupled plasma discharge in the xenon gas; extraction is implemented through a set of electrostatic lenses and apertures. Published data for exact sputter yields in this specific configuration is limited, because milling rate depends on beam current, impact angle, and workpiece material. The downstream production process consists of package-level sample preparation, broad-beam ion milling of solder bumps, copper pillar interconnects, and through-silicon vias, followed by scanning electron microscopy or energy-dispersive X-ray analysis. Terminal products are TEM lamellae, package-level cross-section specimens, and process control monitors for advanced packaging.
Automotive high-intensity discharge burner photometric behavior depends on xenon cold-fill pressure, which determines warm-up speed, reignition voltage, and electrode sputter rate. Burner type approval follows ECE R99, and lamp safety is evaluated under IEC 62035:2014. The fill gas is not a blend; xenon cold-fill absolute pressure typically falls between 5 bar and 15 bar for 35 W D1/D2 and D3/D4 burners. The mercury dose is in the 0.2 mg to 0.5 mg range; metal halide salt dosing is lamp-specific, and published data for exact salt formulations is limited. Downstream production includes quartz arc tube formation, electrode insertion, pinch sealing, evacuation, xenon backfill, outer-jacket mounting, and photometric screening for color temperature and lumen output. Processing bottlenecks arise during pinch sealing, where excessive thermal load can devitrify the quartz and create stress fractures that fail under high-temperature ignition. Burner orientation is fixed during photometric testing because arc bowing varies with fill pressure and electrode geometry. Terminal products are D1S, D2S, D3S, and D4S automotive headlamp burners and aftermarket replacement lamps.
Plasma display panel discharge performance is governed by the Ne/Xe gas mixture, not by any external process atmosphere, because xenon excitation produces the 147 nm and 173 nm vacuum ultraviolet photons that pump the phosphor layer. The panel fill uses 4 vol% to 10 vol% xenon in neon, with total fill pressure between 400 torr and 600 torr; helium addition up to 30 vol% lowers the firing voltage but reduces vacuum ultraviolet efficiency. Increasing xenon content within this window raises VUV output and luminous efficacy, but it also increases sustain voltage and discharge delay, which creates a process conflict for panel drive electronics. Optical measurement follows IEC 61988-2-1:2005. The downstream production process includes back-plate and front-plate fabrication, barrier rib formation, phosphor deposition, frit sealing, vacuum bake at 300 °C to 400 °C, and gas backfill through a tubulation port. Terminal products are plasma display televisions, commercial information displays, and high-ambient-brightness public displays.
Digital cinema projection relies on xenon short-arc lamps, in which the xenon fill pressure and electrode geometry set the arc luminance and spectral radiance. Lamp safety is assessed under IEC 62035:2014; cinema projector integration also requires lamp-housing interlocks and forced-air cooling. Xenon cold-fill pressure ranges from 5 bar to 20 bar absolute depending on lamp wattage; during operation internal pressure rises to 50 bar to 100 bar as gas temperature increases. The fill gas is nominally 99.999 vol% xenon, not a mixture. Downstream production includes quartz envelope forming, tungsten electrode machining, pinch sealing, evacuation, xenon fill, and accelerated aging; spectral radiance and arc stability are measured with spectroradiometers before shipment. Operation beyond the rated current accelerates electrode erosion and quartz devitrification, compressing lamp life from a typical 1000 h to 1500 h down to 300 h or less. Solar simulator spectral match is classified under IEC 60904-9:2020 when the lamp is used as the irradiance source. Terminal products are 2K and 4K cinema projection lamps, solar simulator light sources, and high-power searchlight systems.
Competitive Xenon (Xe) Electronic/EL Grade prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8615365186327
Email: admin@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Xenon (Xe) Electronic/EL Grade is a compressed noble gas supplied for semiconductor front-end, optoelectronic, and electric propulsion processes where impurity-controlled feed gases are specified. The product is identified by CAS 7440-63-3, UN 2036, and molecular weight 131.293 g/mol. Representative commercial designations combine purity level, product class, and cylinder volume; a product code such as Xe-5.5N-EL-50L denotes 99.9995% minimum purity, electronic/EL preparation, and a 50 L water-capacity cylinder. Xenon’s normal boiling point is -108.1 °C at 101.325 kPa; its gas density is 5.897 kg/m³ at 0 °C and 101.325 kPa; and its critical temperature and pressure are 16.6 °C and 5.84 MPa. Because filling at 21 °C can exceed the critical pressure, cylinder contents may exist as a supercritical fluid, so gas withdrawal calculations use real-gas compressibility rather than ideal-gas assumptions.
Xenon is obtained from air separation, where its atmospheric concentration is about 0.086 ppmv. The cryogenic air separation unit concentrates xenon in the krypton-xenon fraction, and electronic/EL material is further processed by getter and cryogenic adsorption to remove oxygen, moisture, nitrogen, carbon species, and particulates. The additional purification is required because single-digit ppm impurity levels can alter excimer laser kinetics, plasma etch repeatability, and lamp fill chemistry.
Electronic/EL xenon specifications center on oxygen, moisture, nitrogen, total hydrocarbons, carbon monoxide, carbon dioxide, fluorocarbon, and particle loadings. The limits listed below are representative of a merchant 5.5N electronic grade; individual certificates of analysis vary by supplier.
| Parameter | Limit | Analytical Method |
|---|---|---|
| Purity | 99.9995% minimum | Balance by difference |
| Oxygen | <0.5 ppmv | Gas chromatography with pulsed discharge helium ionization detection |
| Moisture | <0.5 ppmv | Cavity ring-down spectroscopy |
| Nitrogen | <0.5 ppmv | Gas chromatography with pulsed discharge helium ionization detection |
| Total hydrocarbons as methane | <0.1 ppmv | Gas chromatography with flame ionization detection |
| Carbon monoxide | <0.1 ppmv | Gas chromatography or Fourier transform infrared spectroscopy |
| Carbon dioxide | <0.1 ppmv | Gas chromatography or Fourier transform infrared spectroscopy |
| Particles ≥0.1 µm | <5 per standard cubic foot | Condensation particle counter |
The methods require calibration gases traceable to national metrology institutes under ISO 17025. Moisture measurement by cavity ring-down spectroscopy at 0.5 ppmv carries an expanded uncertainty of approximately ±0.1 ppmv, and lot release normally requires all impurities to remain below 50% of the published maximum so that analytical variability does not produce false acceptance. For 6N Xenon Electronic Grade, some suppliers tighten moisture and oxygen to <0.1 ppmv and total hydrocarbons to <0.05 ppmv, but not all distributors use identical method detection limits; the certificate of analysis should be reviewed before qualifying the cylinder for a process line.
In excimer laser fill gas delivery, Xenon Electronic/EL Grade is metered into premix cylinders with neon or helium buffer and a halogen donor such as HCl or F₂ diluted in helium. A typical XeCl laser head uses 1% to 2% xenon, 0.1% to 0.3% halogen donor, and a total operating pressure of 2–5 bar. The dominant wavelengths are 308 nm for XeCl, 351 nm for XeF, and 282 nm for XeBr. Moisture in the fill gas quenches the upper laser level and produces corrosive HCl in the laser tube; a rise from 0.5 ppmv to 2 ppmv moisture can measurably reduce pulse energy and increase window contamination after 10⁷–10⁸ shots. Gas replacement intervals are therefore affected by impurity buildup as much as by halogen depletion. Most excimer gas panels use mass flow controllers with repeatability of ±0.5% of setpoint for halogen donor and xenon injection; electronic grade xenon prevents the moisture and hydrocarbon background from converting a stable laser gas fill into an absorbing mixture.
For semiconductor plasma etch and ion beam etch, the high atomic mass of xenon improves physical sputter yield and sidewall profile control. Inductively coupled plasma sources operated at 5–100 mTorr chamber pressure and 0.2–2 kW RF power use xenon as a noble sputter gas in magnetic tunnel junction and hard-mask open etch. Electronic/EL xenon reduces cylinder-borne metal and organic contamination. In xenon difluoride vapor etching of silicon, electronic xenon is used as the feedstock for fluorination; water in the xenon feed above 0.5 ppmv can generate HF in the synthesis loop, altering etch selectivity. Published wafer-level defect data for xenon-only metal-hard-mask etch is limited; tool-specific design-of-experiments is required when changing from argon or krypton to xenon.
Electronic/EL cylinders are vacuum-baked at 60–80 °C for 12–24 h, helium leak tested, passivated, and filled only from dedicated manifolds. The cylinder valve is commonly CGA 580 in North America or DIN 477 No. 6 in Europe, with stainless steel or nickel internals. Elastomer seals are minimized in favor of metal-to-metal seals to prevent plasticizer migration and moisture ingress. Cylinder preparation also includes internal particle counting after drying; typical acceptance is fewer than 5 particles per standard cubic foot at ≥0.1 µm. The package is then filled to a service pressure typically between 50 bar and 60 bar at 21 °C, with the final fill mass controlled by load cell to ±0.2% of target.
Once installed, the cylinder must be connected to a gas cabinet with forced exhaust and oxygen-deficiency monitoring. The gas panel should use electropolished 316L stainless steel tubing, orbital welding, and high-integrity face-seal fittings rated for at least 6.0 MPa. Pressure-reducing regulators with Hastelloy C-22 diaphragms and metal-to-metal seats are used to bring cylinder pressure to 0.3–0.6 MPa tool delivery pressure. Before process gas is introduced, the panel is leak-tested with helium at 1×10⁻⁹ mbar·L/s maximum leak rate and purged with purified helium or argon until the outlet moisture is below 10 ppbV. Dual-cylinder changeover panels should execute 10–15 pressure/vent cycles to remove dead-leg contamination; the remaining impurity burden is a function of valve seat leakage and panel dead volume rather than the bulk xenon specification.
Research and industrial xenon grades often carry oxygen and moisture burdens of 1–5 ppmv and may lack particle or total hydrocarbon specifications. The electronic/EL product class reduces these impurities by an order of magnitude and adds cylinder-by-cylinder certification. In excimer laser service, a qualification run with industrial xenon typically shows faster pulse-energy roll-off and earlier optics degradation. In Hall-effect thruster propellant feed, particulates above 5 µm can lodge in porous tungsten inserts and shift cathode emission; electronic/EL packaging is therefore specified for long-duration satellite propulsion. Comparative impurity targets are shown in the following table.
| Parameter | Electronic/EL 5.5N | Research 5N | Industrial 4.8N |
|---|---|---|---|
| Minimum purity | 99.9995% | 99.999% | 99.998% |
| Oxygen | <0.5 ppmv | <1 ppmv | <5 ppmv |
| Moisture | <0.5 ppmv | <1 ppmv | <3 ppmv |
| Nitrogen | <0.5 ppmv | <1 ppmv | <5 ppmv |
| Total hydrocarbons as methane | <0.1 ppmv | <0.5 ppmv | <2 ppmv |
| Particle specification | <5 per standard cubic foot ≥0.1 µm | Not specified | Not specified |
| Cylinder preparation | Vacuum bake, passivation, particle count | Vacuum purge only | Standard industrial |
| Lot certification | Lot-specific impurity certificate | Lot analysis | Certificate of conformance |
The difference between electronic/EL xenon and laser-grade xenon is often related to certification and packaging. Laser-grade xenon may meet the same bulk impurity limits for oxygen and moisture but may not include semiconductor-grade particle counting, lot-specific moisture by cavity ring-down spectroscopy, or equivalent valve outlet cleaning. For semiconductor front-end qualification, the electronic/EL designation is used because wafer defect budgets are tied to airborne molecular contamination and particles rather than only gas-phase purity.
Xenon cylinders should not be heated above 50 °C. The real-gas pressure rise in a closed cylinder can exceed the safety relief valve setpoint if local heating occurs. Cylinder relief valves are commonly set near 75% of service pressure; a 60 bar service cylinder may relieve at 45 bar. Storage areas must be secured, ventilated, and posted for simple asphyxiation. Xenon is chemically inert and does not require oxidizer or flammable gas segregation; however, oxygen-deficiency monitoring is required because a leak can displace air without visible indication.
Flow control in ion thrusters and excimer laser panels uses mass flow controllers calibrated for xenon; use of argon or nitrogen calibration factors is not acceptable because the thermal flow signal depends on gas heat capacity. A xenon mass flow controller with full-scale 50 sccm to 500 sccm should have a setpoint accuracy of ±1% of full scale and a leak-tight shutoff of <1×10⁻⁵ sccm helium. The high molecular weight of xenon produces lower gas conductance than helium in the same line; panel designers must increase bore diameter or delivery pressure to maintain the same mass flow.
Xenon Electronic/EL Grade is also used in high-intensity discharge lamps and flash lamps, where cold-fill xenon at 5–10 bar increases luminous efficacy and arc stability. Moisture and hydrogen in lamp fill gas below 0.5 ppmv are critical to preventing alkali metal reaction in the arc tube. Spacecraft electric propulsion qualifies this grade by lot-specific certificate and long-duration storage stability; cylinder-to-cylinder consistency is verified by residual gas analysis before tanking.