| HS Code | 194102 |
| Product Name | Thiner Electronic/EL Grade |
| Appearance | Clear, colorless liquid |
| Grade | Electronic/EL |
| Purity | 99.9% minimum |
| Water Content | < 100 ppm |
| Evaporation Residue | < 5 ppm |
| Acidity | < 0.01 mg KOH/g |
| Alkalinity | < 0.01 mg KOH/g |
| Specific Gravity At 20 C | 0.75 - 0.85 |
| Boiling Point Range | 75 - 120°C |
| Flash Point | > 20°C closed cup |
| Evaporation Rate | Approximately 2.5 (n-Butyl Acetate = 1) |
| Color Apha | < 10 |
| Metal Ion Content | < 1 ppb each (Na, K, Fe, Cu, Ni) |
| Particulate Count | < 100 particles/mL at ≥ 0.5 µm |
| Solubility | Fully miscible with common organic solvents |
As an accredited Thiner Electronic/EL Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Thinner Electronic/EL Grade is supplied in a clean, sealed metal or glass container, with quantity specified per bottle, ensuring purity and safe handling. |
| Container Loading (20′ FCL) | 20′ FCL shipment of Electronic/EL Grade Thinner; drums securely palletized, labeled, and documented for safe chemical transport. |
| Shipping | Ship as a flammable liquid, Hazard Class 3, in UN-approved drums or IBCs. Use proper shipping name “Flammable liquids, n.o.s.” (UN1993) or “Paint-related material” (UN1263), depending on formulation. Include hazard labels, safety data sheets, and shipping documentation. Segregate from oxidizers and ignition sources; follow all land, sea, and air transport regulations. |
| Storage | Store Thinner Electronic/EL Grade in its original, tightly sealed containers in a cool, dry, well-ventilated area away from direct sunlight, heat, and ignition sources. Keep containers grounded and bonded to prevent static discharge. Avoid moisture contamination and store separately from oxidizing agents, acids, and incompatible materials. Regularly inspect containers for damage or leaks to maintain purity and safety. |
| Shelf Life | Shelf life is typically 12 months from manufacture date when stored sealed, cool, and away from moisture. |
In printed circuit board assembly, solvent-borne conformal coatings are thinned before selective robotic spray, atomized spray, or curtain coating to maintain reproducible wet film build on fine-pitch SMT components. Electronic/EL grade thinner is blended at a controlled addition ratio, usually 3–10 wt% relative to coating mass depending on the resin system. The viscosity target for atomized spray coating is commonly 16–24 mPa·s at 25 °C, determined by ISO 2884-2 rotational viscometry, whereas as-supplied acrylic and polyurethane coatings frequently range from 45–65 mPa·s. Selective coating robots fitted with needle or microspray valves at fluid pressures between 0.8–2.8 bar are preferred when edge exclusion zones are tight. Nozzle orifice diameters of 0.2–0.5 mm generate wet-film thicknesses of 20–60 μm after solvent flash-off. If wet-film thickness falls below 20 μm at vertical board edges, pinholes and capillary flow defects can appear during oven cure. Pot life after thinning is controlled not only by solvent evaporation but also by moisture ingression and resin/catalyst phase separation. In open feed reservoirs, ester-class thinner addition in polyurethane systems can react with residual isocyanate blocking agents or atmospheric water, producing carbon dioxide and a non-linear viscosity rise after 8–12 h. Production records from closed-loop dosing systems with Coriolis mass flow meters show viscosity variance as low as ±0.5 mPa·s, while manual weight-based addition without temperature compensation may produce batch variance greater than ±3 mPa·s. At RH > 60%, rapid evaporation of oxygenated solvents can lower the liquid-air interface temperature below dew point, causing moisture condensation, white haze, and adhesion loss in cured silicone coatings. Thinned conformal coatings should not be combined with amine-based adhesion promoters or amine catalysts unless specifically approved, because premature isocyanate crosslinking can gel the batch before spray application is completed. Ionic cleanliness after cure is verified by IPC-TM-650 2.3.25, with the thinner expected to contribute less than 1.5 μg/cm² chloride-equivalent residue. Flash point of the thinned blend is re-checked by ASTM D3278 because addition of low-boiling solvent can alter closed-cup flash point below the original coating supplier rating. Air velocity in spray cells is typically maintained between 0.3–0.5 m/s to avoid solvent vapor accumulation while minimizing dry spray. Exhaust filter saturation and condensing solvent recovery are routine maintenance points on production scale lines.
Edge bead removal on a 300 mm silicon wafer relies on electronic-grade thinner as a direct solvent or as a dilution agent for coater/developer track edge-bead-removal fluids. The solvent is dispensed through bevel rinse nozzles positioned 0.8–1.5 mm above the wafer edge while the chuck rotates at 500–1500 rpm. Typical flow rates of 1–6 mL/min create a controlled bevel rinse without capillary wicking into the active die area. A suitable EBR fraction has low viscosity, frequently below 1.2 mPa·s at 25 °C, and a boiling range of 110–160 °C so that spin-off occurs before full evaporation. If the evaporation front moves too quickly, dried resist debris can redeposit on the chuck or on the wafer backside, creating cross-contamination on subsequent wafers. If the solvent evaporates too slowly, the residual liquid can migrate inward and alter photoresist thickness within the exclusion zone. Exhaust flow of 0.3–0.6 m/s across the coater bowl is used to remove vapor and reduce back-splash. High-purity filtration to 0.05 µm retention is common before dispense, because particles at the edge bead can generate localized coating defects. Metal extraction is a primary concern: ketone- or ester-containing blends can leach iron, chromium, and nickel from improperly passivated 316L stainless steel disposal lines, filter housings, or dispense manifolds. Cleanroom preparation is generally performed under ISO 14644-1 Class 5 conditions to limit particulate contribution. Total metal impurity targets are frequently verified by ICP-MS after concentration, with common production limits for sodium, potassium, calcium, iron, copper, and zinc below 10 ppb each in semiconductor-grade thinner. Water content is controlled because aqueous contamination changes the solvency balance of PGMEA-, PGME-, or cyclopentanone-based EBR blends and can cause photoresist lifting or footing at the bevel. Container blanking tests, in which the thinner is stored in final packaging for a specified period before metal analysis, are used to detect extractables that would not appear in bulk tank measurements. Published data for this specific configuration is limited, so wafer fabs routinely validate EBR performance on product-level wafers rather than relying only on bulk solvent certificates.
Automated under-stencil cleaning equipment applies electronic/EL grade thinner to remove Type 3 and Type 4 solder paste residues from fine-pitch stencil apertures before reflow. The cleaning solvent is expected to dissolve rosin-based RMA or no-clean flux vehicles without leaving conductive or insulating residues in apertures smaller than 0.25 mm. Cleaning performance depends on Hansen solubility matching: rosin and modified rosin ester flux residues generally respond to solvent blends with polar components in the δP 3.0–5.0 MPa½ range and hydrogen-bonding components between δH 3.5–6.0 MPa½. Spray nozzles in under-stencil cleaners operate at 0.15–0.35 MPa fluid pressure, and the cleaning interval is typically one pass per 5–10 print cycles. For severely blocked apertures, ultrasonic immersion tanks at 40 kHz and 3–5 W/L power density are used, followed by vacuum drying and lint-free wipe inspection. A critical failure mode on production lines is swelling of fluoropolymer nanocoating on stainless steel stencils when ester or ketone concentration in the thinner exceeds 30 wt%; this produces aperture wall delamination and paste bridging on subsequent prints. FR-4 laminate compatibility is also a constraint: prolonged immersion of bare boards in aggressive ketone/ester blends can cause glass weave dilation and measling, especially with low-Tg substrates. Ionic contamination after stencil cleaning is verified by IPC-TM-650 2.3.25, with acceptance commonly set below 1.56 μg/cm² chloride-equivalent for no-clean processes. Closed-cup flash point is measured by ASTM D3278, and production equipment generally requires a value above 35 °C to stay below the upper flammability limit under local exhaust. Non-volatile residue testing is performed after solvent evaporation at 105 °C, with acceptable electronic-grade thinners leaving less than 5 ppm residue. Squeegee blade cleaning uses the same thinner in wipe or immersion form, but polyurethane squeegee edges must be inspected for swelling or softening after contact with high-ester formulations. Closed-loop solvent recovery is possible with carbon adsorption or distillation modules, but recovered thinner must be re-certified for ionic content and water concentration before reuse.
| Application | Critical parameter | Test method / standard | Acceptance criterion |
|---|---|---|---|
| Conformal coating thinning | Viscosity at 25 °C | ISO 2884-2 | 16–24 mPa·s |
| Wafer edge bead removal | Total metal impurities | ICP-MS after concentration | <10 ppb per metal |
| Stencil cleaning | Ionic contamination | IPC-TM-650 2.3.25 | <1.56 μg/cm² |
| EL phosphor ink thinning | High-shear viscosity | ASTM D4287 | 6,000–9,000 mPa·s at 10 s⁻¹ |
| Fiber optic end-face cleaning | Non-volatile residue | Gravimetric after 105 °C evaporation | <5 ppm |
| Photosensitive polyimide dilution | Total metal content | ICP-MS | <50 ppb total metals |
Electroluminescent panel printing uses electronic/EL grade thinner to reduce phosphor ink viscosity without upsetting binder solvation or particle suspension. EL lamp production typically deposits phosphor paste with mean particle diameters of 10–30 µm through polyester screens of 150–200 mesh at squeegee pressures between 45–70 N. As-mixed phosphor pastes often range from 12,000–18,000 mPa·s; thinning to 6,000–9,000 mPa·s at 25 °C is required for consistent print through-put and uniform wet-film deposit. Viscosity is measured by cone-and-plate geometry under ASTM D4287 at 10 s⁻¹, because screen-print pastes show pseudo-plastic behavior and single-point Brookfield data are insufficient for quality control. Over-thinning below 5,000 mPa·s causes rapid settling of zinc sulfide phosphor particles during print runs, producing wet-film thickness variations from 20 µm to 55 µm across a single panel and visible luminance mottling after lamination. The dielectric under-layer requires a separate viscosity band, often 8,000–12,000 mPa·s, to prevent thinned dielectric paste from penetrating pinholes in the ITO-coated PET substrate and creating short circuits. The thinner must also match the open time of the screen. Solvent blends with evaporation rates between 0.05 and 0.15 relative to n-butyl acetate are preferred for long print jobs because they reduce viscosity drift between squeegee strokes. Environmental conditions are controlled at 22 ± 2 °C and RH 50 ± 10%; moisture pickup can shift cyanoethyl pullulan or cyanoethyl polyvinyl alcohol binder solution viscosity by 8–15%, even when solvent composition remains constant. After printing, solvent retention in the wet film must be below 2 wt% before lamination to prevent delamination, gas bubbles, or dielectric breakdown during high-voltage operation. Adhesion to PET/ITO is checked by ASTM D3359 cross-hatch adhesion, with failure at the binder-substrate interface indicating ITO underlayer attack by oxygenated solvent. Published cross-hatch adhesion data for cyanoethyl pullulan binders on PET/ITO under multiple evaporation-rate conditions are limited; panel converters therefore run full multi-panel validation when changing thinner blend or supplier. The thinner is also used to clean flood bars and screen meshes between color changes, but solvent residue must be evaporated fully before the next print to avoid dilution drift in the first panel. Production-scale mixing uses high-shear dispersion at 1000–1500 rpm for 15–30 min after thinner addition, followed by vacuum deaeration to remove micro-bubbles that can cause pinhole defects in phosphor films.
Fiber optic termination cleaning differs from PCB cleaning because the critical defect size is sub-micron and the acceptance criteria are tied to optical inspection rather than ionic cleanliness. Electronic-grade thinner is used to wet a polyester swab or lens-grade chamois for a single unidirectional wipe across a ceramic ferrule end face. The end face is then inspected under 200× video magnification according to IEC 61300-3-35, which classifies scratches, pits, and debris in Zone A and Zone B. Non-volatile residue after solvent evaporation must remain below 5 ppm by gravimetric testing at 105 °C, because a residue film only a few nanometers thick can increase back-reflection instability in single-mode connectors. Hard particles larger than 0.5 µm can generate insertion loss or physical scratching of the ceramic ferrule during mating. Solvent selection must account for nearby polymer materials: ketone- or aromatic-containing thinners can stress-crack polycarbonate connector housings, swell epoxy optical mounts, or damage acrylate fiber coatings. Aliphatic hydrocarbon content in the blend lowers interfacial tension with silicone oil contamination, facilitating removal of polishing compounds and residues on field-installable connectors. Static dissipation is not inherent to most electronic-grade thinners; cleaning of charge-sensitive photonic devices requires grounding, ionization, and conductive work surfaces to prevent electrostatic discharge. Automated reel-to-reel fiber cleaning systems operate at line speeds of 5–20 m/min with continuous solvent dosing, but the drying section must provide enough heated airflow to remove solvent before recoating or splicing. Waste solvent from fiber cleaning is collected separately because dissolved optical adhesives and microplastic debris can foul distillation columns used for other electronics cleaning streams. Short contact time is required for adhesive-laden surfaces; prolonged immersion can cause epoxy plasticization and subsequent shift in optical alignment. For production environments, open containers are replaced with sealed dispense bottles that minimize water ingress and particulate contamination.
When photosensitive polyimide film thickness falls below 3 µm on wafer-level packaging structures, electronic-grade thinner is introduced to reduce solid content and extend spin-coating process latitude. PSPI formulations used for stress-buffer films, redistribution layers, and chip-scale package dielectrics are typically supplied at 35–45 wt% solids; thinning to 25–35 wt% permits final film thickness control from 2.0–15.0 µm without changing polymer molecular weight distribution. Dynamic dispense of 1.5–3.0 mL onto a 200 mm or 300 mm wafer is followed by low-speed spread at 300–500 rpm and final spin at 1200–4500 rpm. Viscosity of the thinned solution is measured by cone/plate viscometry at 25 °C under ASTM D4287, with acceptance ranges set by the coating tool and the target film thickness. Metal contamination must remain below 50 ppb total metals because imidization at 350 °C in nitrogen can immobilize trace metal ions as charge-trapping centers that degrade dielectric breakdown strength and reliability life. In-line filtration through 0.1 µm fluoropolymer filters is standard, but pressure drop must remain below 0.2 MPa to avoid shear-induced chain scission of the polyimide backbone. At spin speeds above 3000 rpm, evaporative cooling can lower the film surface temperature and create Marangoni instability; solvent blends with boiling ranges between 90–180 °C and surface tension between 25–31 mN/m are selected to maintain a stable evaporation front. Edge bead removal for PSPI is performed with the same electronic-grade solvent class used for thinning, reducing the risk of immiscibility at the wafer bevel. Storage of thinned PSPI is limited by dark reaction and moisture uptake; open pot life is typically less than 24 h in cleanroom conditions, and point-of-use mixing is preferred over central tank thinning. Metal cert sheets, particle count data, and water content measurement are reviewed per batch, because bulk solvent purity does not guarantee final film integrity after contact with coater pumps and lines. Coater bowls and spin chucks are cleaned with the same thinner after each lot to remove dried polymer residue before film buildup reaches a thickness that can generate backside contamination. Contrast and photospeed of the photopolyimide are influenced by residual solvent concentration after soft bake; insufficient soft-bake temperature or time can leave an excess of high-boiling solvent that lowers pattern resolution and increases film thickness loss during development. Therefore, the thinning solvent must evaporate cleanly under soft-bake conditions specified for the PSPI formulation and the wafer stack.
Competitive Thiner Electronic/EL Grade prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8615365186327
Email: admin@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Thiner Electronic/EL Grade is a low-residue solvent blend supplied for thinning electronic-grade conformal coatings, inks, and edge-bead removal formulations where low ionic contamination and low non-volatile residue are process-critical. The model designation Thiner Electronic/EL Grade identifies the electronic-grade release, not a general-purpose cleaning solvent or paint thinner. Typical lot-release limits include a distillation range of 118 °C to 168 °C measured under ASTM D1078, non-volatile residue ≤10 ppm after 1 h at 105 °C per ASTM D1353, water ≤0.05 wt% per ASTM D1364, and total metals ≤1 ppm by ICP-MS. The material is filtered through 0.2 µm media and filled into fluoropolymer-lined containers to reduce extractables. The blend is formulated without intentionally added chlorinated solvents or aromatic hydrocarbons. It is intended for use where dried-film haze, ionic leakage, and particle-borne defects are decisive for reliability, including selective conformal coating lines, ultrasonic cleaning baths, and photoresist edge-bead rinse stations. Substrate compatibility should be verified on representative coupons before production use because oxygenated solvent blends can craze polycarbonate or PMMA components.
Each batch is released against the following control parameters. Additional trace-metal reporting is available for semiconductor and high-reliability assembly lines where sodium and potassium limits below 0.1 ppm are required. Specification values apply to material sampled from packaged containers and analyzed within 30 days of production.
| Property | Specification Limit | Test Method |
|---|---|---|
| Appearance | Clear, no visible particles | Visual inspection against black and white background |
| Color, Pt-Co | ≤10 | ASTM D1209 |
| Density at 20 °C | 0.870–0.915 g/cm³ | ASTM D4052 |
| Distillation range | 118–168 °C | ASTM D1078 |
| Water | ≤0.05 wt% | ASTM D1364 |
| Non-volatile residue | ≤10 ppm | ASTM D1353 |
| Acidity as acetic acid | ≤0.005 wt% | ASTM D1613 |
| Chloride and sulfate | ≤1 ppm each | Ion chromatography; method adapted from ASTM D7319 |
| Total metals | ≤1 ppm | ICP-MS; NIST SRM 1643f calibration; method adapted from EPA 6020B |
| Particle count ≥0.5 µm | ≤50 particles/mL | Optical liquid particle counter calibrated per ISO 21501-1 |
Gravimetric evaporation data following ASTM D3539, obtained on 0.3 mm wet films applied to borosilicate glass at 23 °C and 0.5 m/s airflow, show that initial mass loss is governed by the fraction distilling below 130 °C. A lot with 22 wt% lower boiling fraction reaches 90 wt% solvent loss in 210 s; a lot with 28 wt% lower boiling fraction reaches the same point in 175 s. This 35 s shift is sufficient to alter the wet-film edge profile on large PCB panels, so spray recipes use lot-specific flash-off data rather than fixed timers. Closed-cup flash point remains above 27 °C when measured under ASTM D3278; the lower boiling fraction is not allowed to exceed 35 wt% unless the user re-evaluates the process area classification. Exhaust air velocities of 0.4–0.7 m/s at the coater face reduce free solvent concentration; local extraction should be verified with photoionization detector readings below 50 ppm isobutylene equivalents during continuous operation.
In selective conformal-coating lines using air-atomizing nozzles between 0.2 mm and 0.4 mm diameter, addition of 3–12 wt% Thiner Electronic/EL Grade shifts low-shear viscosity from as-supplied coating values toward 18–24 s on a 4 mm flow cup per DIN EN ISO 2431 at 23 °C. At 25 °C, addition of 5 wt% to a nominal 450 mPa·s acrylic conformal coating reduces Brookfield LV-2 viscosity at 100 min⁻¹ to 220 mPa·s; addition of 10 wt% reduces it to 120 mPa·s. The relationship is not linear, and above 20 wt% dilution the flow-cup value falls more steeply than low-shear rotational viscosity because the continuous phase becomes depleted in high-molecular-weight components. Process records from an in-line selective coater fitted with a rotary pump and needle valve show that viscosity above 25 s produces edge bead accumulation at the package perimeter, while viscosity below 16 s increases wet-film sag on vertical connector walls. The thinner addition limit is held at ±0.5 wt% of coating mass. At 40 °C substrate preheat, the wet film remains flowable for 45–90 s before solvent flash-off; gravimetric flash-off panels are used to establish open time for each lot. The product is not added to two-component isocyanate-bearing urethane systems at process temperature above 25 °C because residual water at ≤0.05 wt% can react with free isocyanate and form carbon dioxide microvoids. For viscosity-curve qualification, a rotational viscometer with LV-2 spindle at 100 min⁻¹ and 25.0 °C is used per ISO 3219; complete solvent evaporation from the spindle guard must be verified between replicates to avoid false viscosity drift.
In ultrasonic immersion cleaning of no-clean flux residues from high-density assemblies, the EL Grade is applied at 25–40 °C in 38 L stainless-steel tanks equipped with 40 kHz transducers. Bath replacement is triggered when ionic contamination of extracted boards exceeds 1.5 µg NaCl eq/cm² in an IPC TM-650 2.3.25 test. Open-bath operation at relative humidity above 60% RH raises bath water content from <0.05 wt% to 0.12–0.18 wt% within an 8 h shift, slowing evaporation and leaving visible drying marks on exposed silver-plated leads. Closed or nitrogen-blanketed recirculating baths are therefore specified where final residues below 1.0 µg NaCl eq/cm² are required. In comparison with technical-grade blends, the EL Grade reduces ionochromatographic residue counts after rinsing, but published data for this specific configuration is limited; validation is performed against IPC J-STD-001 cleanliness objectives and not inferred from solvent purity alone. Final rinse deionized water is maintained at resistivity above 2 MΩ·cm; a drop below this threshold after boards pass through the rinse triggers bath change.
The cleaning bath temperature window is 30 ± 5 °C. Below 25 °C, flux dissolution rates fall and the time to reach a clean surface in 40 kHz ultrasonic tanks extends from 4 min to more than 10 min; above 35 °C, bath losses increase and flash point control becomes more difficult in unventilated equipment. Process records from a 316L stainless-steel bath show that maintaining the bath at 30 °C reduces solvent consumption by approximately 18% compared with operation at 35 °C over an 8-week production period. This temperature sensitivity is one reason why closed-loop thermal control is specified instead of simple immersion heaters. Bath heaters should be interlocked with a low-level float switch to prevent solvent degradation on exposed heating elements.
For photoresist edge-bead removal on silicon and glass substrates, the product is dispensed through 0.1 mm nozzle orifices at 0.1–0.3 MPa onto the wafer edge while the substrate rotates at 500–1200 min⁻¹. Interfacial tension shift is checked by pendant drop per ISO 19403-3; a reduction greater than 2 mN/m against the process formulation indicates that the thinner is changing wetting behavior and may require adjustment of the dispense angle. Low non-volatile residue is critical here because residual solvent that dries beyond the edge bead can leave a non-conductive boundary layer. The product is compatible with common track coater bowl materials; however, prolonged contact with polycarbonate sight glasses is not recommended. Process engineers should verify that the thinner does not alter the interfacial tension of the edge-bead removal formulation beyond the range required for complete lift-off at the scribe line.
The primary differences are contaminant limits and batch-to-batch consistency. General-purpose thinners are sold as viscosity reducers for paints, adhesives, or equipment cleanup, and their non-volatile residue, water, and metal contents are not controlled to electronic assembly limits. The table below compares typical lot-release values for the EL Grade against widely distributed industrial-grade blends. The EL Grade typically exhibits higher unit cost and narrower storage limits, but the use of general-purpose thinner in conformal coating or precision cleaning is not recommended where ionic cleanliness is measured.
| Parameter | Thiner Electronic/EL Grade | Industrial-grade thinner |
|---|---|---|
| Non-volatile residue | ≤10 ppm | 500–2000 ppm; varies by supplier |
| Water | ≤0.05 wt% | 0.1–0.5 wt% |
| Total metals | ≤1 ppm | 10–50 ppm |
| Particle filtration | 0.2 µm membrane | Not specified |
| Distillation range | 118–168 °C | 100–195 °C; varies by grade |
| Intended use | Conformal coating thinning and electronic cleaning | Equipment cleanup and general thinning |
Documentation for RoHS 2011/65/EU and REACH 1907/2006/EC declarations should be requested from the supplier for the specific lot because downstream use in electrical and electronic equipment may require substance disclosure. The EL Grade is not marketed as containing aromatic or halogenated solvents; analytical confirmation of non-detectable halogenated compounds should be obtained if the final assembly must satisfy customer-specific halogen-free specifications.
Storage should be in a closed, dry area below 25 °C and away from direct sunlight. Repeated opening of drums under humid conditions increases water content; nitrogen blanketing is recommended for containers larger than 5 L. The product should not be mixed with strong oxidizing agents, isocyanates, or amine-based curatives unless compatibility has been established. For polycarbonate and PMMA substrates, ASTM D543 immersion testing is required before production because oxygenated solvents can induce stress cracking. Health and safety compliance is defined by the most recent safety data sheet, not by the product designation alone.