    Specifications
    HS Code 528500
    Product Name Silver Plating Solution (MacDermid Silver Max 300) Electronic/EL Grade
    Product Type Electrolytic silver plating solution
    Chemical System Alkaline, non-cyanide organic silver complex
    Appearance Clear to light amber liquid
    Physical State Liquid
    Odor Mild odor
    Ph 9.0 - 10.5
    Specific Gravity 1.10 - 1.20 at 25°C
    Boiling Point Approximately 100°C (212°F)
    Freezing Point Approximately 0°C (32°F)
    Silver Content 30 - 40 g/L of metallic silver
    Solubility In Water Fully miscible
    Operating Temperature Range 20 - 35°C (68 - 95°F)
    Cathode Current Density 0.5 - 4.0 A/dm²
    Deposit Purity ≥ 99.9% silver
    Storage Temperature 15 - 30°C (59 - 86°F)

    As an accredited Silver Plating Solution (MacDermid Silver Max 300) Electronic/EL Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Supplied in a 1-gallon (3.78 L) HDPE container with secure closure, labeled MacDermid Silver Max 300 Silver Plating Solution, Electronic/EL Grade.
    Container Loading (20′ FCL) 20′ FCL of MacDermid Silver Max 300 electronic-grade silver plating solution, securely packed, segregated, and containerized per hazardous chemical regulations.
    Shipping Shipping: This Silver Plating Solution must be handled as a hazardous chemical. Consult the Safety Data Sheet for the exact UN number (likely UN 1713 or 1588, Class 6.1, Packing Group II). Use UN-certified containers, label as toxic, and segregate from acids. Include proper shipping documentation and emergency response details.
    Storage Store Silver Plating Solution (MacDermid Silver Max 300, Electronic/EL Grade) in tightly sealed original containers in a cool, dry, well-ventilated area away from heat, sparks, and direct sunlight. Avoid contact with acids and oxidizing agents. Keep containers upright to prevent leaks, and ensure the storage area is clearly labeled and secured.
    Shelf Life Shelf life is typically 6 months when stored tightly sealed in original container at recommended temperatures.
    Application of Silver Plating Solution (MacDermid Silver Max 300) Electronic/EL Grade

    Silver Max 300 Electronic/EL Grade is operated as an electrolytic silver deposit for selective reel-to-reel, rack, and barrel plating where the functional requirement is a 99.9% silver layer with controlled porosity and low-voltage contact resistance. The supplier-defined control envelope comprises 28–32 g/L silver metal, pH 8.5–9.0, 50–60°C, and 0.2–2.0 A/dm² cathode current density. The faradaic silver equivalent is 4.025 g per A·h; at 95% cathode efficiency the theoretical deposition rate is 36.5 µm/h at 1.0 A/dm², but field uniformity losses on stamped and etched geometries reduce the practical rate to approximately 0.5–0.7 µm/min in flat zones. The deposit is classed under ASTM B700 Type II and, when invoked, MIL-DTL-45204D Type II Grade A Class 2.

    Press-Fit Connector Finishes: Insertion Force Stability and Porosity Thresholds

    Electrodeposited silver is applied to copper-alloy press-fit tail zones on reel-to-reel selective lines to keep terminal insertion force within 25–60 N per pin and maintain a gas-tight interface through the compliance section of the pin. The preplate sequence on 0.25–0.40 mm C7025 or C19400 strip comprises alkaline electrocleaning at 5.0–10.0 A/dm², 10–20 vol% sulfuric acid activation, a sulfamate nickel underplate of 1.5–2.5 µm, and a silver strike before Silver Max 300 deposition at 0.5–1.5 A/dm² and 55°C. The silver thickness at the contact zone is held at 2–5 µm; below 2 µm, ASTM B809 porosity coupons over the nickel underplate show a rise from fewer than 1 pore/cm² to more than 5 pores/cm² on stamped sidewall radii, which is the established failure threshold for gas-tight press-fit zones.

    Current density distribution, rather than absolute current, defines the operating boundary. On stamped strips, the edge radius concentrates the electric field; at planar current settings above 2.0 A/dm², nodular growth appears at the strip edge within 2–4 min. Production cells therefore use segmented insoluble anodes and conforming shields to hold edge current density at 0.8–1.2 A/dm² while the flat contact zone carries 1.0–1.5 A/dm². This arrangement maintains thickness tolerance across a ±0.5 µm band on the functional tail. Replenishment is metered at 4.025 g silver per A·h with a 0.95 efficiency correction; the organic additive feed is adjusted by hull cell steering rather than fixed volume, avoiding additive overloading that produces carbon codeposition and later wire-bond failure. Porosity is the first acceptance criterion because gas-tight zones do not tolerate through-pores. Production lots are tested per ASTM B809 on flat pad samples and on formed sidewall coupons cut from the actual stamped geometry; a pore count above 1/cm² at 5 µm triggers a line shutdown and additive re-balance. Finished parts include backplane press-fit connectors and board-to-board interconnects tested in accordance with IEC 60352-5 and IEC 60603-2, used in ATCA chassis and industrial programmable-logic controller assemblies.

    Full-body silver plating of WR-28 and WR-34 waveguide cavities machined from 6061-T6 aluminum or C11000 copper is run at 5–10 µm thickness to reduce conductor insertion loss above 26.5 GHz. Aluminum substrates require a double zincate pretreatment and a cyanide copper strike of 1.5–2.5 µm before Silver Max 300; copper substrates receive a non-cyanide copper strike or enter the silver bath directly after cleaning, but only if oxide removal is verified by a water-break-free surface. The rack fixture uses internal conforming anodes because the corner thickness of a rectangular cavity without an auxiliary anode is only 40–60% of the flat-zone thickness. The bath is run at 0.2–0.8 A/dm² with a 50°C set point, and flat-zone thickness is raised to 8–10 µm so that internal corners do not drop below 3 µm. For silver at 10 GHz, skin depth is approximately 0.64 µm; therefore the deposit bulk is electrically active only near its outer surface, and the more important quality variables are surface roughness below 0.4 µm Ra and freedom from nodulation. Terminal products include 5G mmWave cavity filters, satellite feed horns, and test-waveguide calibration sections. Tarnish control uses a benzotriazole-free passivation dip; without this step, silver sulfide formed in IEC 60068-2-60 Method 4 mixed-flow gas exposure increases insertion loss by 0.05–0.2 dB after 21 days.

    What Current Density Window Prevents Burnt Edge Growth on QFN Leadframes?

    On QFN leadframes etched from 0.127–0.203 mm C19400 or EFTEC-64T strip, Silver Max 300 is deposited selectively on die pads and lead fingers through a reel-to-reel spot cell. The current density window is 0.5–1.5 A/dm². Above 2.0 A/dm², burnt edge growth appears as raised nodules along the etched sidewall within 3–5 min, because the current density concentrates at the transition between photoresist opening and bare alloy. The effect is amplified when silver metal content exceeds 32 g/L, when pH drifts above 9.5, or when strip speed drops and dwell time in the high-current zone increases. Acceptable top-surface thickness is 3.0–5.0 µm, and sidewall coverage must not fall below 60% of the top-surface value. Thickness audits use XRF per ASTM B568 and cross-sectional SEM at die-attach pad corners; optical comparison is insufficient for sidewall characterization.

    Finished QFN strip enters die-attach reflow at 350°C for 60 s; the plated surface must remain free of discoloration and intermetallic voiding. Wire-bond shear strength after 25 µm silver wire bonding is tested per MIL-STD-883 Method 2011.9; production lots are trended by SPC because wire type and bond-pad alloy shift the acceptance limit. The EL Grade additive set is designed to limit co-deposited metallic impurities to below 50 ppm total, because higher impurity levels correlate with increased cratering risk during thermosonic bonding. Anode-to-cathode area ratio is maintained at 2:1 to 4:1 with platinised titanium mesh; this ratio stabilizes bath potential and reduces additive oxidation at the anode. Published data for this specific configuration is limited when palladium-coated copper wire is substituted; qualification coupons are required for each wire type. Terminal products include QFN packages for power management ICs, gate drivers, and RF front-end modules.

    In mid-power LED leadframe plating, Silver Max 300 is used as a 1.0–3.0 µm functional silver layer on the reflector cup and die-attach pad, applied at 0.5–1.0 A/dm² on reel-to-reel lines. The top-surface thickness is selected by the thermal design of the package, not by reflectivity alone; measured reflectance is compared against a production reference mirror at 450 nm, with no absolute reflectance threshold because package geometry dominates optical extraction. The deposit is specified as ASTM B700 Type II; RoHS recast 2011/65/EU does not restrict silver metal. Finished leadframes are supplied for 0.2–5 W white LED packages and automotive exterior lighting arrays. The main operational limitation is silver tarnish during storage before die attach; leadframe inventory is therefore limited to 72 h after plating when ambient sulfur is uncontrolled.

    Micro-Relay and MEMS Contact Metallization Under Hot-Switching Loads

    Silver Max 300 deposits at 0.5–2.0 µm thickness are applied to signal-relay blades and MEMS switch contact pads using rack or controlled-vibration barrel plating. Barrel current density is limited to 0.2–0.8 A/dm²; higher barrel settings create thickness spans from 0.2 µm to 2.5 µm within the same load and produce poor contact-force distribution. The primary boundary is hot-switching: at 5 V DC and 10 mA, fine transfer arcs can increase four-wire contact resistance from below 5 mΩ to above 20 mΩ after 10⁴–10⁵ cycles per ASTM B539. For dry-circuit signal loads below 20 mV and 10 mA, a 1.5 µm deposit remains below 10 mΩ after 100,000 operations per ASTM B667. An anti-tarnish dip containing 0.1–0.5% mercaptobenzothiazole in alcohol is applied as a final step; without it, IEC 60068-2-60 mixed-flow gas exposure causes contact resistance drift within 72 h. Terminal products include telecom signal relays, pogo-pin landings, and MEMS cantilever switches.

    When Silver Max 300 Replaces Hard Gold on Edge Card Pads Below 0.4 mm Pitch

    Edge-card pad metallization at 0.30–0.40 mm pitch uses Silver Max 300 selectively over electroless nickel-phosphorus at 3–5 µm with 7–9 wt% phosphorus. The silver topcoat is set at 2–4 µm; thickness below 2 µm increases porosity over the nickel and permits pad-edge corrosion, while thickness above 4 µm raises the risk of silver migration at fine pitch and increases material cost without functional gain. A nickel underlayer must be present because silver directly over copper can form copper-silver intermetallic within 30 days at 85°C/85% RH, increasing contact resistance and reducing solderability. The main process conflict is edge-card insertion durability versus silver’s lower hardness compared with hard gold; repeated insertion beyond 50 cycles can wear the topcoat enough to expose nickel at the pad periphery.

    The limiting environmental boundary is silver electrochemical migration under DC bias. At 0.3 mm spacing, 10 V DC, and 85°C/85% RH, IPC-TM-650 Method 2.6.14.1 surface insulation resistance coupons show dendritic shorting when the surface is unprotected. A conformal anti-tarnish coating preserves insulation resistance above 10⁸ Ω after 1,000 h. Terminal products include memory-module edge cards and industrial plug-in controller boards where insertion cycles are below 50 and service humidity is controlled by enclosure sealing.

    Test parameterStandard/methodAcceptance criterion
    Silver thicknessASTM B5682–4 µm Ag over 3–5 µm Ni-P
    Nickel-phosphorus contentASTM B7337–9 wt% P
    AdhesionASTM B571No separation after 90° bend
    PorosityASTM B8091 pore/cm² on flat pads
    SolderabilityJ-STD-00295% coverage after 8 h steam aging
    Surface insulation resistanceIPC-TM-650 2.6.14.1>10⁸ Ω after 1,000 h at 85°C/85% RH
    Free Quote

    Competitive Silver Plating Solution (MacDermid Silver Max 300) Electronic/EL Grade prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615365186327

    Email: admin@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    The MacDermid Silver Max 300 electrolyte is a liquid alkaline non-cyanide electrolytic silver plating system supplied in electronic grade for connector, leadframe, relay, and selective-plating operations. The model designation separates it from bright decorative silver and immersion silver finishes; the Electronic/EL suffix indicates a formulation with reduced organic additive loading intended to preserve solderability, wire-bonding performance, and stable contact resistance. The product is normally provided as a make-up concentrate and a replenisher/additive package, and it is operated in rack, barrel, or reel-to-reel equipment with a direct-current rectifier and insoluble or soluble anodes as approved by the supplier. Because the bath does not contain free cyanide, the working environment and rinsewater treatment are not governed by alkaline cyanide destruction; however, silver recovery and pH neutralization are still required. Published product-specific numerical ranges for this formulation are limited in public secondary sources; the current revision of the manufacturer’s technical data sheet is the controlling document for silver concentration, pH, temperature, and current density. In qualification practice, the deposit is evaluated by thickness, adhesion, solderability, and contact resistance according to ASTM B700-20, J-STD-003, and ASTM B667-97(2019).

    The electrolyte operates by cathodic reduction of silver(I) species in an alkaline non-cyanide medium. This mechanism differs from immersion silver, where silver deposition proceeds by displacement on copper and is self-limiting. The non-cyanide chemistry reduces the regulatory and operational burden of cyanide but requires more disciplined pH, agitation, and replenishment control. The Electronic/EL grade is not a bright decorative silver; the additive system is selected to limit fine organic inclusions that can appear as carbon-bearing residues in the deposit. For high-reliability applications, the underlayer stack, final thickness, and post-treatment are specified together because silver is susceptible to tarnishing in sulfur-containing environments and to migration under humid DC bias.

    How Does Silver Max 300 Differ from Cyanide and Immersion Silver Chemistries?

    Compared with conventional cyanide silver, the most immediate difference is waste treatment. Cyanide silver baths generate dragout containing free cyanide and metal cyanide complexes; treatment requires alkaline cyanide oxidation, commonly with sodium hypochlorite or electrochemical oxidation, before pH reduction and silver precipitation. Silver Max 300 does not contain free cyanide, so the treatment sequence can be shortened to precipitation of silver with sulfide, dithiocarbamate, or proprietary scavengers, followed by solids removal. This does not eliminate all waste-treatment duties: silver-bearing sludge remains a regulated or recoverable solid, and the complexing system may require mild oxidation or pH adjustment before discharge. In terms of plating performance, cyanide silver usually has higher throwing power and wider tolerance to low agitation; the non-cyanide electrolyte delivers similar deposit purity but often needs higher solution velocity, closer anode-to-cathode spacing, and more frequent additive analysis to prevent mid-current-density dullness or edge buildup.

    Immersion silver is not a substitute for Silver Max 300 when thickness above 0.3 µm is required. Immersion silver forms a thin, self-limiting layer on copper by chemical displacement; it is used as a final finish on printed circuit boards, but it cannot provide the controlled thickness build of an external-current electrolytic process. Silver Max 300 is also differentiated from electroless silver by the requirement for a rectifier; electroless silver does not require external current but has limited commercial use due to bath stability and control complexity. The electronic-grade designation should not be interpreted as a tarnish-proof or migration-proof finish; it indicates a reduced additive residue and suitability for interconnection processes when qualified on the actual device.

    Representative class comparison for electronic silver chemistries; product-specific control limits remain as defined by the supplier data sheet.
    CharacteristicSilver Max 300 Electronic/EL gradeConventional cyanide silverImmersion silver
    Free cyanideNot presentPresent; requires cyanide oxidationNot present
    Deposition driveExternal DC rectifierExternal DC rectifierSpontaneous displacement on copper
    Thickness capabilityFaradaic; 0.2–5.0 µm common in connector workFaradaic; often 1–10 µm for wear or electronicsSelf-limiting; typically 0.05–0.3 µm
    Organic additive loadReduced electronic-gradeBrightener and grain refinersLow to moderate depending on formulation
    Waste streamSilver precipitation without cyanide oxidationCyanide oxidation followed by silver precipitationDragout and silver recovery; no cyanide oxidation
    Process sensitivityRequires pH and agitation controlHigh throwing power; robustRequires microetch control and copper surface management

    For reel-to-reel selective plating lines with insoluble anodes, the Silver Max 300 working electrolyte is maintained by ampere-hour-based replenishment of the silver concentrate and by analytical silver titration or atomic absorption control. The rectifier ripple is held below 5% rms because high ripple can promote nodulation and reduce grain uniformity. Cathode-to-anode spacing and solution flow through eductor nozzles or flooded cells are adjusted to maintain thickness uniformity across stamped strip; this is more critical in the non-cyanide electrolyte than in a high-throwing-power cyanide bath. Bath pH is controlled within the mild alkaline window stated in the current data sheet; corrections are made with the designated pH adjuster rather than generic acid or caustic, because improper adjustment can destabilize the silver complex and form colloidal or metallic silver sludge. Operating temperature is maintained by immersion heaters or external heat exchangers. Filtration through 1–5 µm polypropylene cartridges is standard for electronic-grade plating. Air agitation is generally avoided in electronic non-cyanide silver plating because oxygen can accelerate carbonate accumulation and degrade reducing agents; mechanical agitation or eductor recirculation is preferred.

    The make-up procedure for electronic-grade non-cyanide silver baths normally uses deionized water with a resistivity above 10 MΩ·cm to limit calcium, chloride, and sulfate contamination. The silver concentrate is added first, followed by the supplier’s wetting and grain-refining additives; pH is then adjusted with the designated alkaline or acid solution. The bath is not acidified with raw mineral acid unless explicitly approved, because the silver complex can precipitate as silver salts or metal. For initial start-up, a silver strike is often used on copper and nickel substrates to prevent immersion deposition or adhesion failure; the strike can be a separate silver tank or a low-current-density in-situ treatment. Analytical control includes silver metal titration, pH, specific gravity, and additive activity tests. Replenishment is best performed after each shift or after a defined ampere-hour count on automated lines. Over-replenishment of silver can reduce grain uniformity at high current density; under-replenishment can cause burning at the cathode edge. These process control requirements are typical for alkaline non-cyanide noble metal baths, and the exact product-specific tolerances are listed in the MacDermid technical data sheet.

    The bath is not tolerant of cyanide drag-in from preceding cyanide copper or silver strike baths; dedicated rinses and separate dragout controls are required. Similarly, acidic dragout or brightener contamination from nickel lines can reduce bath life and should be isolated by rinsing and pH control. In barrel plating, barrel rotation and solution exchange are adjusted so that low-current-density areas inside the barrel receive sufficient silver; barrel plating of electronic connectors often uses finer grain refiners to avoid rough or non-uniform deposits. Production experience on reel-to-reel lines shows that thickness uniformity is more sensitive to contact alignment and solution flow than in cyanide silver, and that belt speed, masked area, and current density must be developed together rather than copied from a cyanide line.

    When Connector and Leadframe Applications Require Low Porosity Without Cyanide Post-Rinse

    Silver Max 300 is applied where a cyanide-free electrolytic silver is required for solderability, low contact resistance, or high-frequency surface conductivity. Typical electronic components include press-fit connectors, USB-type shells, relay contacts, leadframes, EMI shielding cans, and wire-bond pad areas that cannot tolerate cyanide dragout. On copper alloy substrates, a nickel or copper underlayer of 1–3 µm is often used to prevent copper diffusion; a silver strike may be needed for adhesion. Final silver thickness for connector applications commonly falls between 0.5 µm and 2.0 µm, while wear-contact applications may require 2.0–5.0 µm. Below 0.5 µm, porosity can expose the underlayer and increase corrosion risk in mixed-gas tests; above 5.0 µm, deposit stress and cost increase without proportional electrical benefit except in specific wear or wire-bond conditions.

    The electrolytic mechanism allows selective deposition on defined areas using masks, plating tape, or reel-to-reel spot plating; immersion silver cannot produce such localised thickness because it requires full contact with the copper surface. The Electronic/EL grade is intended to avoid the high organic brightener content associated with decorative silver finishes, but it is not inherently tarnish-proof. Silver tarnishes in sulfur-containing atmospheres, so parts may require post-treatment, protective packaging, or connector lubricant when used in high-humidity or industrial environments. Qualification for solderability is performed after steam aging or mixed-gas exposure according to J-STD-003 or IEC 60068-2-20, and contact resistance is measured in accordance with ASTM B667-97(2019) at a defined probe force and geometry.

    For press-fit connectors, the final silver layer is often specified to maintain low insertion force after aging; silver provides a hard lubricious surface compared with tin, but the tarnish film may increase contact resistance if the contact interface is not gas-tight. For high-frequency signal connectors, silver thickness is configured to maintain effective surface conduction at the frequency of interest; at higher frequencies, current concentrates in the outer skin, so thickness uniformity is more important than total silver volume. The application of Silver Max 300 should be accompanied by process capability studies on the actual stamped strip or turned contact, because geometry, masking, and current density distribution affect the deposit more than the bath chemistry alone.

    Deposit Purity, Solderability, and Contact Resistance Benchmarks

    Electronic-grade silver deposits are evaluated primarily for purity, thickness, adhesion, solderability, and contact resistance. The purity of an Electronic/EL grade deposit should meet the engineering silver minimum of 99.9% silver specified in ASTM B700-20; this value is more easily maintained when the organic brightener load is low and when the bath is not over-replenished. Thickness is measured on production coupons or actual parts by X-ray fluorescence according to ASTM B568-98(2021) or by cross-section according to ASTM B487-20. Adhesion is checked by bend, tape, or thermal shock methods defined in ASTM B571-97(2013). Solderability after aging is verified using J-STD-003 or IEC 60068-2-20; silver surfaces typically exhibit rapid wetting on adequately cleaned underlayers, but tarnish films from sulfur exposure can increase wetting time if the parts are not protected.

    Contact resistance measurements performed with a hard-metal probe at 50–100 cN in accordance with ASTM B667-97(2019) often fall below 10 mΩ for clean silver; exact values depend on probe radius, surface roughness, and applied current. For high-frequency applications, the deposit is also assessed for thickness uniformity because skin-effect conductivity concentrates current near the conductor surface; this is an application-specific measurement rather than a bath property. Codeposited organic residues in decorative bright silver can increase apparent resistivity and reduce wire bond pull strength after thermal aging; the Electronic/EL grade is formulated to reduce this failure mode. The reduction in organic residue does not remove the need for clean rinsing after plating; residual electrolyte or brightener on the surface can still lead to tarnish, adhesion loss, or solder wetting defects.

    Compliance and test matrix for electronic silver deposits
    PropertyReference method or regulationTypical acceptance criterion
    Silver purityASTM B700-2099.9% silver
    ThicknessASTM B487-20, ASTM B568-98(2021)As specified on part print; often 0.5–2.0 µm
    AdhesionASTM B571-97(2013)No blisters or separation after bend or thermal shock
    SolderabilityJ-STD-003 / IEC 60068-2-20Uniform wetting after preconditioning
    Contact resistanceASTM B667-97(2019)Low milliohm range; process-specific limit
    Restricted substancesRoHS Directive 2011/65/EU Annex IINo cadmium, lead, mercury, or hexavalent chromium in deposit

    Operating boundaries for the Silver Max 300 electronic electrolyte include incompatibility with cyanide contamination, acid dragout, and uncontrolled pH corrections. The bath is not an immersion silver and will not deposit by displacement without external current; rack or barrel loads without electrical contact will not plate. The non-cyanide chemistry is more sensitive to carbonate accumulation than cyanide silver, and regular analytical monitoring of silver metal, pH, specific gravity, and additive levels is required. In wastewater treatment, the absence of cyanide allows silver precipitation by sodium dithiocarbamate or proprietary metal scavengers, followed by clarifier settling and filter press dewatering; however, the resulting silver-bearing sludge must be classified under applicable hazardous waste regulations. The deposit itself is not immune to tarnish in sulfur-rich environments, and silver migration under humid DC bias remains a circuit-design constraint that must be controlled by spacing, coating, or conformal coating.

    For original equipment manufacturer qualification programs, published data for this specific configuration is limited in secondary sources; qualification coupons should therefore be processed on the exact reel or barrel line and tested against the final assembly specification before lot acceptance. The bath is not intended for decorative use, and the Electronic/EL grade should not be combined with bright decorative silver additives unless approved by the supplier. Mixing with cyanide silver or other non-cyanide silver chemistries is not permitted; even small volumes of contaminated dragout can alter grain refinement and reduce solderability. The deposit’s performance is evaluated on the finished part, not from generic coupon data; solderability tests, mixed-gas exposure, and contact resistance measurements must be repeated after any change in underlayer, masking, rinsing, or post-treatment.

    Top