| HS Code | 453127 |
| Chemical Formula | HClO4 |
| Molecular Weight | 100.46 g/mol |
| Cas Number | 7601-90-3 |
| Grade | Electronic/EL Grade |
| Concentration | 70% w/w aqueous solution |
| Appearance | Clear colorless liquid |
| Density | 1.664 g/cm3 at 25°C |
| Boiling Point | 203°C |
| Melting Point | -17°C |
| Vapor Pressure | 6.8 mmHg at 25°C |
| Solubility In Water | Miscible |
| Specific Gravity | 1.67 |
As an accredited Perchloric Acid Electronic/EL Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Packaged in a 1 L fluorinated HDPE bottle with leak-proof closure, under nitrogen, ensuring high-purity perchloric acid for electronic applications. |
| Container Loading (20′ FCL) | 20' FCL loading: secure upright drums/containers of Perchloric Acid EL Grade, with proper segregation, bracing, and spill containment. |
| Shipping | Perchloric Acid Electronic/EL Grade ships as UN 1873, Perchloric Acid Aqueous Solution—a Class 5.1 oxidizer with corrosive subsidiary risk. Approved leak-tight packaging, typically glass or fluoropolymer, is required. Shipments carry hazard labels, dangerous-goods documentation, and emergency response guidance, kept segregated from organic and reducing materials to prevent dangerous reactions. |
| Storage | Store Perchloric Acid Electronic/EL Grade in a dedicated, clearly labeled acid cabinet made of inert, corrosion-resistant materials, away from organics, reducing agents, and combustible materials. Keep containers tightly sealed, upright, and in secondary containment. Ensure cool, well-ventilated conditions, protected from sunlight and temperature extremes, with spill containment and compatible handling protocols. |
| Shelf Life | Shelf life is typically 6 months from manufacture; store cool, tightly sealed, away from organics to prevent decomposition. |
Electronic-grade perchloric acid is supplied as a 69.0–72.0 wt% aqueous solution with a density of approximately 1.67 g/cm³ at 25 °C and is not used in anhydrous form when blended into chromium etchants for photomask processing. In a quartz photomask blank, the functional stack comprises a sputtered chromium layer of 60–110 nm thickness, often capped with CrOxNy, on a 6025-grade quartz substrate. Wet etching must remove the chromium hard mask without attacking the quartz and without leaving cation residues at the Cr/quartz interface. Perchloric acid in a ceric ammonium nitrate, (NH4)2Ce(NO3)6, etchant maintains the Ce(IV)/Ce(III) redox potential above approximately 1.2 V versus Ag/AgCl, which drives chromium oxidation from Cr(0) to Cr(VI) and reduces redeposition of Cr2O3 at the metal edge.
Concentration control is critical because excess free perchlorate raises ionic strength and retards mass-transfer-limited etch rate, while insufficient HClO4 lowers the redox potential and produces black chromium oxide residue. The acid is typically dosed to maintain 0.3–0.5 M perchlorate in the working bath, with bath temperature controlled at 35–40 °C in a PVDF or PTFE-lined spray processor or quartz immersion tank. Endpoint is determined by laser reflectometry at 670 nm, and total clear-etch time for a 105 nm chromium film commonly runs 60–120 s; published data for exact supplier-specific blending ratios on 6025 masks is limited. The wetted surface materials are restricted to PVDF, PTFE, and quartz because 316L stainless steel releases chromium and nickel into the bath and shifts the cation burden on the reticle. The resist used to pattern the chromium layer must be chemically resistant to the etchant, and the bath must not be contaminated with stripper solvents or residues because perchlorate-organic mixtures can form hazardous deposits.
The finished photomask blank is rinsed with ultrapure water, dried with filtered nitrogen, and measured for surface metal contamination by total reflection X-ray fluorescence according to ISO 14706:2014. Sodium, aluminum, and iron are the critical cations because they affect mask transmission, defect density, and resist adhesion. The aqueous HClO4-containing etchant does not attack the quartz substrate at the process temperature, but microroughness on the quartz surface is controlled by limiting etch time and by maintaining uniform bath agitation.
Twin-jet electropolishing of 3 mm transmission electron microscope disks uses a chilled perchloric acid-alcohol electrolyte to thin metals, alloys, and semiconductors until perforation occurs. A common electrolyte for copper, aluminum, austenitic stainless steel, and titanium is 8–12 vol% HClO4 in methanol or ethanol, held at −30 °C to −20 °C. In this window the anodic current density is typically 50–300 mA/cm², and the applied DC voltage is 10–30 V. The electronic/EL grade acid is specified because Fe from technical acid deposits as a nanocrystalline metallic film on the perforation edge. At 50 ppb Fe, each liter of electrolyte carries approximately 50 µg of iron, which is sufficient to produce X-ray fluorescence artifacts and shifting of the local work function in electron energy-loss spectroscopy.
Temperature is the critical process variable; above −15 °C the diffusion-limited current rises sharply and the reaction of perchlorate with methanol can generate methyl perchlorate, creating an explosive hazard. The electrolyte reservoir is therefore jacketed and connected to a recirculating chiller, while the polishing cell is built from PTFE. The cathode is 99.95 % platinum, and the jet flow rate is 5–10 mL/min per side in commercial twin-jet units such as Struers TenuPol-5 or Fischione Model 110. The power supply is operated in constant-voltage mode, and the perforation endpoint is detected by a photodiode when transmitted light reaches a preset intensity. Over-polishing expands the perforation but reduces the usable wedge thickness below 10 nm.
Electrolyte batch life is short because water absorption from ambient air alters the perchlorate-alcohol equilibrium. An electrolyte batch is discarded when the base current at −25 °C increases by more than 15 % from its initial value or when the electrolyte darkens. The final foil is rinsed in methanol and isopropanol and dried under clean dry air. This application is confined to small electrolyte volumes below 250 mL and is not scaled to trough-style electropolishing; the fume hood must be of perchloric acid-rated washdown design and free of accumulated organic film.
Trace-metal certification of silicon, gallium arsenide, indium phosphide, sapphire, and high-purity device materials requires digestion in acids that do not add analyte cations at parts-per-trillion blank levels. High-purity HClO4 at 70 % is used after HNO3/HF pre-digestion because the high-boiling azeotrope reaches 203 °C, allowing dense white fumes to convert refractory fluorides and organic residues into soluble perchlorate salts. In a typical high-purity silicon digestion, a sample mass of 0.2–0.5 g is weighed into a 50 mL PTFE beaker, wetted with 3–5 mL electronic-grade HNO3, treated with 1–2 mL HF, and taken to HF fuming at 160 °C. After volume reduction, 0.5–1.0 mL HClO4 is added and heated to dense white fumes at 180–190 °C on a PTFE-lined graphite hot block. The final residue is re-dissolved in 2 % HNO3 and diluted to 50 mL with ISO 3696:1987 grade 1 water.
The perchloric acid stock must be chosen so that the total metal blank does not exceed 1 ng/g in the final diluted digest when solid method detection limits below 0.01 µg/g are required. Digestion batches are prepared inside ISO 14644-1:2015 Class 5 laminar-flow workstations. Quadrupole ICP-MS instruments with collision or reaction cell modes are used to suppress Cl-O and Ar-Cl interferences that originate from acid-derived chloride; perchloric acid is preferred over hydrochloric acid in some schedules because it introduces a lower chloride blank. The fuming step requires a dedicated perchloric acid-rated hood with washdown and no exposed organic deposits, because distillate collected on duct surfaces can accumulate shock-sensitive perchlorate films.
| Parameter | Photomask Cr etch | TEM twin-jet polishing | ICP-MS digestion |
| HClO4 assay | 69.0–72.0 wt% | 69.0–72.0 wt% | 69.0–72.0 wt% |
| Iron | ≤10 µg/L | ≤5 µg/L | ≤0.5 µg/L |
| Sodium | ≤10 µg/L | ≤5 µg/L | ≤0.5 µg/L |
| Chloride | ≤2 mg/L | ≤1 mg/L | ≤0.5 mg/L |
| Cleanroom handling | ISO 14644-1:2015 Class 6 | ISO 14644-1:2015 Class 6 | ISO 14644-1:2015 Class 5 |
High-purity lithium perchlorate used in non-aqueous lithium primary cells and in specialized electrochemical systems is synthesized by neutralizing lithium carbonate with electronic-grade perchloric acid. The stoichiometry is Li2CO3 + 2 HClO4 → 2 LiClO4 + H2O + CO2. Because perchlorate salts are highly soluble, most cation impurities introduced by the acid remain in the crude product after evaporation, which makes the cation budget of the raw acid the primary purity driver. The reaction is run in a glass-lined or PTFE-lined reactor at 60–70 °C, with HClO4 added at a rate no higher than 3 mL/min per liter of reaction mass to control CO2 evolution. The endpoint is held at pH 7.0–7.5, and excess acid is back-titrated with lithium carbonate. The crude solution is filtered through a 0.2 µm PTFE membrane and vacuum-concentrated below 80 °C to avoid thermal decomposition.
Process control focuses on sodium, potassium, calcium, lead, and chloride. For lithium anode applications, sodium and potassium levels in LiClO4 below 20 µg/g are required to avoid dendrite initiation; this translates to raw acid Na and K limits in the low single-digit µg/L range depending on dilution. The final product is assayed by ion chromatography for ClO4−, by ICP-MS for cations, and by Karl Fischer titration for moisture. Drying is performed at 120–130 °C under vacuum below 10 mbar until water is below 50 µg/g. Storage is in sealed aluminum-laminated pouches under dry argon because LiClO4 is hygroscopic and a strong oxidizer; contact with reducing solvents is prohibited, and the drying oven must be explosion-proof and free of organic grease.
Electropolishing of larger aluminum and stainless steel surfaces for semiconductor equipment components, vacuum hardware, and analytical metallography uses perchloric acid-methanol or perchloric acid-acetic acid electrolytes at low temperature. This process is distinct from twin-jet TEM polishing because the electrolyte volume is 1–20 L and the part geometry controls current distribution. A 5–10 vol% HClO4 in methanol electrolyte is held between −30 °C and −10 °C in a tank externally cooled by a recirculating chiller using a silicone-based heat-transfer fluid. The part is the anode; the cathode frame is 99.95 % platinum or anodically passivated aluminum. The operating voltage is 15–35 V, and the current density for aluminum alloys is 0.2–0.6 A/cm². Electronic/EL grade acid is specified because technical-grade iron and copper contaminants are deposited on the workpiece and later detected by Auger electron spectroscopy or X-ray photoelectron spectroscopy.
The critical risk in this process is thermal runaway. Above −15 °C, the reaction rate of perchlorate with methanol increases rapidly, and the vapor space can accumulate methyl perchlorate. The temperature-control loop therefore uses a dual-channel chiller with an independent high-temperature cut-off at −10 °C and a bath power-density limit. The work area is built with a welded stainless steel liner, a perchloric acid-approved washdown hood, and ventilation designed to NFPA 45:2024. Paper, fabric, and organic grease are excluded from the enclosure. After polishing, the part is rinsed in high-resistivity water, immersed in dilute nitric acid to strip residues, and dried with filtered nitrogen. Surface roughness is verified by white-light interferometry or stylus profilometry; for UHP gas delivery components, the target is normally 0.2 µm Ra or lower, with chromium oxide enriched passivation confirmed by XPS.
Competitive Perchloric Acid Electronic/EL Grade prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8615365186327
Email: admin@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Perchloric acid electronic/EL grade is supplied primarily as an aqueous solution at a nominal concentration of 70.0% (mass fraction), corresponding to a density of 1.67 g/cm³ at 20 °C. The product designation PCA-EL-70-FT identifies the electronic grade, the nominal concentration, and fluoropolymer drum packaging; exact model suffixes vary by supplier, but the EL designation denotes acid refined for semiconductor and electronic wet-process use. The material is filtered through 0.05 µm or 0.1 µm high-purity PTFE/PFA membrane cartridges and is typically packaged in 30 L or 200 L fluoropolymer drums under nitrogen. Trace-metal specifications are established by inductively coupled plasma mass spectrometry using EPA Method 6020B, while assay, density, and refractive index are checked against lot release values. The product differs from technical and ACS reagent grades primarily in particle count control, metallic impurity ceilings, and packaging cleanliness.
Trace-metal ceilings for electronic/EL perchloric acid are derived from ultra-trace contamination control requirements in wafer processing and from the analytical limitations of ICP-MS when handling a high-chloride matrix. The chloride-rich matrix generates polyatomic interferences such as ClO⁺ and ArCl⁺, which affect vanadium and arsenic determinations. Method EPA Method 6020B requires collision/reaction cell operation or standard addition calibration to suppress these interferences. Lot release data for sodium and potassium are commonly specified at ≤ 10 ppb because these ions are mobile contaminants in gate dielectric processing; aluminum, iron, and calcium are controlled below 5 ppb. Batch-to-batch variation has been observed in quadrupole ICP-MS blank levels when the sodium and potassium load rises from 5 ppb to 10 ppb, requiring recalibration of online particle counters and ion chromatographs on certain production wet benches.
| Parameter | Specification | Method |
|---|---|---|
| Assay as HClO4 | 70.0%–72.0% w/w | Acid-base titration |
| Density at 20 °C | 1.66–1.68 g/cm³ | Oscillating U-tube density meter |
| Residue after ignition | ≤ 3 mg/L | Gravimetric |
| Chloride as Cl | ≤ 0.5 mg/L | Ion chromatography |
| Sulfate as SO4 | ≤ 0.5 mg/L | Ion chromatography |
| Phosphate as PO4 | ≤ 0.2 mg/L | Ion chromatography |
| Nitrate as NO3 | ≤ 0.5 mg/L | Ion chromatography |
| Sodium as Na | ≤ 10 ppb | ICP-MS per EPA Method 6020B |
| Potassium as K | ≤ 10 ppb | ICP-MS per EPA Method 6020B |
| Aluminum as Al | ≤ 5 ppb | ICP-MS per EPA Method 6020B |
| Iron as Fe | ≤ 5 ppb | ICP-MS per EPA Method 6020B |
| Calcium as Ca | ≤ 5 ppb | ICP-MS per EPA Method 6020B |
| Chromium as Cr | ≤ 2 ppb | ICP-MS per EPA Method 6020B |
| Copper as Cu | ≤ 2 ppb | ICP-MS per EPA Method 6020B |
| Nickel as Ni | ≤ 2 ppb | ICP-MS per EPA Method 6020B |
| Zinc as Zn | ≤ 2 ppb | ICP-MS per EPA Method 6020B |
| Particles ≥ 0.2 µm | ≤ 1000 particles/mL | Laser particle counter calibrated per ISO 21501-4:2018 |
| Particles ≥ 0.5 µm | ≤ 100 particles/mL | Laser particle counter calibrated per ISO 21501-4:2018 |
| Appearance | Clear, colorless liquid | Visual inspection |
Electronic/EL grade perchloric acid is filtered at point-of-fill and frequently at point-of-use because particle counts at 0.2 µm and 0.5 µm are release-critical parameters. Filtration through 0.05 µm or 0.1 µm high-purity PTFE/PFA cartridges reduces particle burden, but the housing and wetted surfaces must be fluoropolymer or quartz. Stainless steel and titanium are not recommended for prolonged contact with 70% perchloric acid, particularly where chloride impurity can initiate crevice corrosion or metal release. On a production-scale recirculating bath, differential pressure across the final filter is monitored continuously; filter replacement is governed by pressure rise rather than fixed service hours. Clean-room transfer of the acid to wet benches is performed with fluoropolymer pressure vessels or peristaltic pump heads using PTFE tubing. Atmospheric exposure during transfer can introduce airborne particles and water vapor; therefore closed-loop blanketing with nitrogen or filtered air is standard practice on semiconductor lines. The low-particulate behavior of the EL grade is not equally guaranteed by technical or ACS reagent grades, which are typically filled without final membrane filtration or point-of-use particle counting.
Although perchloric acid is not a direct replacement for hydrogen peroxide or nitric acid in standard RCA cleaning sequences, electronic/EL grade material is specified where a strongly oxidizing mineral acid with low particle and trace-metal background is required for metal etch, quartzware cleaning, or contamination sample digestion. In semiconductor analytical support, mixtures of perchloric acid and nitric acid are used for dissolution of metal films and residues from wafer surfaces; the acid is also used to remove chromium and molybdenum layers in specialty device fabrication. In printed circuit board processing, perchloric acid has been used in specific etch formulations for copper alloys, but adoption is limited relative to ferric chloride or cupric chloride etchants because of safety, waste handling, and cost constraints. Published data for its use in oxide CMP slurry formulations is limited; therefore, process qualification is required before substitution into a slurry or post-CMP cleaning sequence. The key operational distinction is that perchloric acid introduces a strong oxidizing potential that can decompose organic contaminants and passivate metal surfaces, but it also imposes strict compatibility limits on tool materials and waste drains.
Heated perchloric acid baths must be restricted to dedicated wet benches with acid-resistant ductwork and wash-down capability. At temperatures above 150 °C, or in contact with organic matter, perchloric acid can form unstable perchlorate esters and metal perchlorates that are shock-sensitive when dry. Metal etch baths using 70% perchloric acid are commonly maintained below 85 °C to avoid accelerated decomposition and vapor generation, although the exact thermal limit depends on bath additives and vessel venting. The operational boundary is determined as much by the bath additive flash point and the ductwork design as by the acid itself. Wetted materials are limited to PTFE, PFA, PVDF, and quartz; polycarbonate and polymethyl methacrylate are incompatible due to oxidative stress cracking. Combination with acetic anhydride, alcohols, glycol ethers, or reducing agents is prohibited because of rapid exothermic reaction and perchlorate ester formation. Waste drain lines for perchloric acid are segregated from sulfuric acid lines and organic solvent lines, and the drains are flushed with water to prevent accumulation of crystalline perchlorate salts. These constraints are not hypothetical; fume hood fires and duct explosions have been documented when perchloric acid was used in ordinary chemical hoods without wash-down and segregated disposal. The EL grade does not alter the intrinsic oxidation hazard; it only controls the trace-metal and particle background that would otherwise contaminate semiconductor surfaces or analytical blanks.
Relative to technical and ACS reagent perchloric acid, electronic/EL grade is distinguished not primarily by assay but by particle burden, trace-metal ceilings, and container cleanliness. Technical grade is commonly supplied at 60% or 70% concentration and may contain chloride above 5 mg/L, with transition metals in the low mg/L range. ACS reagent grade meets monograph limits for chloride, sulfate, residue after ignition, and heavy metals as lead, but does not include sub-ppb transition metal specifications or point-of-use particle monitoring. Electronic/EL grade adds particle control and is packaged in fluoropolymer drums that have been cleaned with dilute nitric acid or hydrofluoric acid and rinsed with ultrapure water before filling.
| Characteristic | Technical grade | ACS reagent grade | Electronic/EL grade |
|---|---|---|---|
| Typical assay | 60%–70% | 60%–72% by monograph | 70.0%–72.0% |
| Chloride as Cl | ≤ 5 mg/L typical | Monograph limit | ≤ 0.5 mg/L |
| Transition metal control | Not individually specified | Heavy metals as Pb only | ≤ 2–10 ppb per element |
| Particle count | Not controlled | Not controlled | ≤ 100 particles/mL at ≥ 0.5 µm |
| Packaging | HDPE drums | Glass or HDPE | Fluoropolymer drums under nitrogen |
| Intended use | Chemical synthesis | Analytical reagent | Semiconductor wet processing and ultra-trace analysis |
In storage, electronic/EL perchloric acid is segregated from organic solvents, reducing agents, and strong dehydrating agents. Bulk containers are vented through acid-resistant scrubbers or check valves; secondary containment is constructed of fluoropolymer-lined steel or high-density polyethylene. Because perchloric acid is hygroscopic, ambient moisture can dilute the 70% assay over extended storage in non-sealed containers. Containers are stored at 15 °C–25 °C and protected from direct sunlight. At relative humidity above 60%, the product may absorb water and drift below assay limits; therefore point-of-use density or refractive index checks are recommended before use in etch rate-sensitive processes. The material should remain in dedicated perchloric acid cabinets and should not be returned to general chemical stores after opening.