    HS Code 366075
    Product Name PCB Special Cleaning Agent (Anji Microelectronics ICS8000) Electronic/EL Grade
    Grade Electronic/EL Grade
    Physical State Liquid
    Appearance Clear, colorless, transparent liquid without suspended particles
    Odor Mild, low odor
    Chemical Nature Ultra-high-purity aqueous electronic-grade cleaning formulation
    Water Solubility Completely miscible with water
    Density 20 C 1.00-1.06 g/cm3
    Ph 25 C 7.0-10.5
    Boiling Point Approximately 100°C
    Flash Point None (non-flammable)
    Voc Content Less than or equal to 0.1%
    Non Volatile Residue Less than or equal to 50 ppm
    Particle Content Less than or equal to 100 particles/mL at particle size ≥0.5 µm
    Individual Metal Impurities Na, Mg, Al, K, Ca, Fe, Ni, Cu, Zn, and Mn each ≤1 ppb
    Ionic Impurity Content Cl⁻ ≤1 ppm, SO₄²⁻ ≤1 ppm, NO₃⁻ ≤1 ppm

    As an accredited PCB Special Cleaning Agent (Anji Microelectronics ICS8000) Electronic/EL Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Anji ICS8000 PCB cleaning agent is supplied in 1 L fluoropolymer-lined HDPE bottles, nitrogen-purged and double-bagged for electronic/EL grade purity.
    Container Loading (20′ FCL) 20' FCL loaded with securely packed drums of Anji ICS8000 electronic-grade PCB cleaning agent, properly labeled and braced.
    Shipping Ship via authorized hazmat carrier in original, sealed containers with proper labeling. Secure upright, away from oxidizers, heat, and foodstuffs. Keep SDS accessible and follow all applicable ground/air transport regulations. Classify as electronic/EL grade high-purity cleaning agent; ensure leak-proof secondary containment to prevent spills during transit.
    Storage Store in a clean, tightly sealed original container in a cool, dry, well-ventilated area away from direct sunlight, heat, and incompatible oxidizers. Maintain stable temperature between 15–25°C, avoid moisture and contamination, and keep segregated from acids, alkalis, and ignition sources. Ensure secondary containment and proper labeling for trace-metal purity protection.
    Shelf Life Refer to manufacturer’s certificate of analysis; typically 12 months from production date when stored unopened in original container.
    Application of PCB Special Cleaning Agent (Anji Microelectronics ICS8000) Electronic/EL Grade

    Anji Microelectronics ICS8000 (Electronic/EL grade) enters the assembly defluxing sequence when lead-free SAC305 reflow leaves heat-activated rosin/weak organic acid residues beneath low-standoff QFN and BGA packages. In an inline spray-under-immersion system, the working bath is prepared at 8–15 vol% in 18 MΩ·cm deionized water meeting ASTM D1193 Type I and held at 45–55 °C; three sequential spray zones deliver total wash residence time 30–45 s at nozzle pressure 0.8–1.2 MPa. The rinse stage uses two counter-flow DI cascades; final rinse conductivity is controlled below 10 µS/cm, and drying air knives operate at 0.5–0.6 MPa with discharge temperature not exceeding 80 °C to avoid solder mask blistering on FR-4 substrates. Ionic cleanliness is assessed with IPC-TM-650 2.3.25; the acceptance criterion is <1.56 µg NaCl eq/cm² for extracted ionics, while no visual residue is permitted on solder joints or board surfaces under IPC-J-STD-001H. Surface insulation resistance is verified according to IPC-TM-650 2.6.3.7; boards must maintain ≥100 MΩ at 85 °C/85% RH under 50 V bias for 168 h. Low-standoff components with clearance below 75 µm require reduced spray pressure or secondary vertical agitation to prevent hydrodynamic trapping; unsealed electromechanical relays and MEMS cavities are excluded from immersion wash unless the component supplier assigns a washable classification under IEC 60749. Finished assemblies include automotive ADAS electronic control units, server CPU motherboards, and power modules with solder mask-defined pads.

    Fine-grain electroformed stencils with aperture area ratios below 0.45 accumulate dried SAC305 paste along aperture walls and underside gasketing zones, especially at 0.3 mm-pitch BGA and 0.4 mm-pitch QFP patterns. In pneumatic under-stencil wipe units, ICS8000 is applied undiluted through 0.2 µm absolute polypropylene filtration; in ultrasonic immersion tanks the working solution is diluted to 10–20 vol% with 18 MΩ·cm DI water and maintained at 35–45 °C. Dual-frequency transducers sweep between 40 kHz and 80 kHz with power density 20–30 W/L to avoid standing-wave cavitation erosion on nano-coated stencil surfaces. Cleaning time per stencil is 3–6 min depending on aperture density, and on nano-coated stencils power density is reduced to 15 W/L to preserve the anti-flux coating. The post-clean rinse continues until final conductivity is below 5 µS/cm; drying uses 0.1 µm filtered compressed air to prevent aperture moisture retention. Stencil design tolerances are governed by IPC-7525B, and paste compatibility is evaluated under J-STD-005. End items include SMT stencils, step stencils, and micro-BGA aperture stencils for mobile board assembly.

    What Are the Rework Limits for Misprinted PCBs Before Solder Paste Tack Time Expiry?

    Misprinted double-sided PCBs that have not passed through reflow are processed in a dedicated batch cleaner with dual-frequency ultrasonics and spray-in-air support. The working fluid is prepared at 10–20 vol% in 18 MΩ·cm DI water at 38–42 °C; ultrasonic power density is held at 15–25 W/L with frequency sweep between 40 kHz and 80 kHz to avoid paste redeposition on exposed solder mask. Total cycle time for 2–4 mm-thick boards is 8–12 min, followed by a two-stage DI rinse and filtered air-knife drying at 0.4–0.5 MPa. Cleanliness is verified using IPC-TM-650 2.3.25; accepted boards meet IPC-A-610H conditions and are returned to solder paste printing only within the paste supplier’s tack-time window, commonly 4–8 h after initial print. Boards with unsealed quartz resonators, open electromechanical relays, or exposed MEMS microphones require localized cleaning or mask protection to prevent liquid ingress. This rework cell supports double-sided automotive sensor boards, RF power amplifier boards, and power-over-ethernet controller assemblies.

    Compliance/test matrix for ICS8000 downstream scenarios
    ScenarioStandard or test methodMeasured parameterControl point
    Post-reflow defluxingIPC-TM-650 2.3.25ROSE ionic contamination<1.56 µg NaCl eq/cm²
    Post-reflow defluxingIPC-TM-650 2.6.3.7SIR at 85 °C/85% RH≥100 MΩ after 168 h
    Stencil cleaningIPC-7525BAperture area ratio / print release≥0.45 for 0.3 mm pitch
    Misprinted PCB reworkIPC-A-610HVisual residue after cleaningNo visible solder paste or gasket transfer
    Pre-conformal coatingASTM D2578Wetting tension≥38 mN/m
    Post-etch cleaningIPC-6012DAHDI board cleanliness / copper surfaceNo cuprous oxide under backlight
    Pre-ENIG cleaningIPC-4552AENIG deposit / pre-plate ionic load<0.5 µg NaCl eq/cm²

    Surface Energy Recovery and Ionic Residue Limits on Cleaned Printed Board Assemblies Prior to Coating

    Assemblies that move into conformal coating after cleaning are washed at 5–10 vol% ICS8000 in 18 MΩ·cm DI water at 40 °C for 60–90 s in a single-chamber spray washer with 0.7 MPa nozzle pressure. A chemical isolation stage with air-knife blow-off prevents drag-out from entering the two-stage DI rinse; final rinse conductivity is reduced to <5 µS/cm. The board is then dried with air knives below 70 °C and processed within 4 h to avoid recontamination from handling. Handling after drying is conducted in an ISO 14644-1 Class 8 cleanroom. Surface energy is measured by ASTM D2578 and must be ≥38 mN/m; water contact angle is measured by ASTM D7334 and is controlled at <25°. Ionic contamination before coating is verified by IPC-TM-650 2.3.25 at <0.75 µg NaCl eq/cm², below the general assembly limit but suitable for silicone and acrylic coating adhesion under IPC-CC-830B. The cleaned output includes LED driver boards, avionics controllers, and outdoor telecom modules that require moisture-resistant dielectric protection.

    Alkaline Etch Residue Removal on Laser-Drilled Microvia Substrates Requires a 5–12 vol% Working Concentration

    After alkaline copper chloride etching of fine-line outer layers, residues adsorb on exposed copper and via capture pads. ICS8000 is introduced at 5–12 vol% in 18 MΩ·cm DI water at 45–50 °C in a horizontal conveyorized spray line with 1.2–1.8 m/min conveyor speed, top/bottom spray pressure 0.7–1.0 MPa, and 0.5 µm absolute filtration. Three-stage DI cascade rinsing reduces final rinse conductivity to <10 µS/cm; pH is monitored according to ASTM E70 and maintained within the supplier-specified working band to avoid copper oxide redeposition. Filtration back-pressure is not permitted to exceed 0.2 MPa; back-pressure above this value forces filter-bag replacement to prevent particulate redeposition. The process is located before dry-film lamination or solder mask application. Compliance with IPC-6012DA for HDI boards requires ionic cleanliness by IPC-TM-650 2.3.25 and absence of cuprous oxide under backlight inspection. Process boundaries include bath life not exceeding 48 h without replenishment, and pH drift above 0.5 units triggers bath replacement. Published data for ICS8000 on via capture-pad residue elimination in this exact conveyor configuration is limited; therefore batch qualification with SEM/EDX is required before high-volume processing. Downstream finished products include HDI PCBs, 5G mmWave antenna modules, and IC test boards.

    When Electroless Nickel Immersion Gold Requires Pre-Plating Cleanliness Below 0.5 µg NaCl eq/cm²

    Before electroless nickel immersion gold deposition, copper pads contaminated with residual organic films create nickel skip, black pad, or poor solder wettability. ICS8000 is used at 8–15 vol% in 18 MΩ·cm DI water at 50–55 °C; conveyorized spray contact time is 45–90 s, while immersion tanks require 3–5 min with recirculation and 0.5 µm filtration. Rinsing continues until final rinse resistivity reaches ≥5 MΩ·cm, and the board is dried below 70 °C before microetch. Cleanliness is verified with IPC-TM-650 2.3.25; the target ionic contamination is below 0.5 µg NaCl eq/cm² to protect the ENIG bath. Deposit thickness and solderability must then meet IPC-4552A and J-STD-003C; failure analysis of nickel skip uses X-ray fluorescence per ASTM B568. Bath temperature above 55 °C accelerates evaporation and concentration drift, so conductivity and pH are recorded every shift. Immersion racks are restricted to titanium or stainless steel; this cleaning step is not combined with bare aluminum fixtures in the same bath because galvanic corrosion can transfer metals to copper pads. Finished printed boards serve aircraft engine controls, automotive braking systems, and semiconductor test sockets.

    Free Quote

    Competitive PCB Special Cleaning Agent (Anji Microelectronics ICS8000) Electronic/EL Grade prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615365186327

    Email: admin@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Post-soldering contamination control in high-density printed circuit board assembly is governed by electrochemical migration risk and cleanliness acceptance criteria defined in IPC J-STD-001H and IPC-TM-650 2.3.25. The Anji Microelectronics ICS8000 PCB special cleaning agent is specified as an electronic/EL grade formulation for removal of organic acid flux residues, no-clean solder paste residues, light machining oils, and particulate contamination from rigid and flexible PCB surfaces before conformal coating, wire bonding, or underfill dispensing. The electronic/EL grade designation imposes controls on trace metal cations, chloride, sulfate, and non-volatile residue that are tighter than those for technical-grade solvents. Because the supplier does not publicly disclose the complete solvent blend, lot-specific values for density, distillation range, and non-volatile residue must be taken from the certificate of analysis.

    In printed circuit board manufacturing and assembly, the cleaning agent is not a universal surface preparation chemical. Its primary process position is after solder paste reflow or wave soldering, where polar and nonpolar flux fractions remain. It is also used in stencil cleaning and misprint cleaning when solder paste has been reflowed or dried, provided the cleaning equipment can maintain solvent contact time and mechanical energy. The product’s purity is relevant when downstream processes are sensitive to ionic contamination; conformal coating adhesion loss and underfill voiding can be accelerated by residual amine or organic acid flux fractions at pad surfaces. The cleaning agent is introduced into the process after thermal profiling and before conformal coating, wire bonding, or encapsulation.

    Electronic/EL grade solvents for PCB cleaning are characterized by low alkali and transition-metal content because these species can lower surface insulation resistance. The ICS8000 designation is paired with a batch traceability system typical for specialty electronic chemicals; incoming inspection should record the batch number, date of fill, and particle count. When the product is received in stainless steel or high-density polyethylene containers, the container liner should be verified for leachable species using the same ion chromatography method applied to the solvent. Published data for the specific packaging configuration used by Anji Microelectronics is limited; user-side qualification is required for any change in container material or lot source.

    What Limits the Cleaning Window for Low-Standoff Micro-BGA and QFN Assemblies?

    Low standoff gaps below 0.20 mm restrict solvent exchange in static immersion baths because capillary forces retain dissolved residues and reduce bulk fluid velocity to near-zero at the interior pad plane. In such configurations, ICS8000 is applied with mechanical assistance. A typical production line uses a two-stage immersion ultrasonic system at 40 kHz and 600–900 W transducer power for 180–300 s, followed by a spray-in-air rinse with deionized water at 18 MΩ·cm resistivity and 15–25 °C. The spray stage should use flat-fan nozzles at 1.5–3.0 bar to generate shear at the PCB surface. For vacuum-assisted processes, a vacuum impulse of −0.8 bar to −0.95 bar gauge for 2–5 min can remove trapped air from under components before the cleaning agent enters the gap.

    Residue removal is controlled by solvent penetration, dissolution, and mechanical displacement. For no-clean flux residues that are thermally crosslinked, the cleaning agent requires a pre-soak or a heated stage. Heating the bath to 35–45 °C lowers the formulation viscosity and increases molecular diffusion into the flux film. However, heating above the flash point or above the boiling range of the low-boiling cosolvent fraction may cause pronounced evaporation and shift the solvent composition, which reduces the dissolution power for high-molecular-weight rosin fractions. Closed-loop equipment with vapor recovery is therefore preferred for continuous production. The ultrasonic frequency may be swept from 35 kHz to 45 kHz to avoid standing waves that can damage fine-pitch wire bonds or sensitive MEMS structures.

    Table 1. Applicable test methods and typical electronic/EL grade solvent cleaner acceptance bands
    PropertyTest methodTypical electronic/EL grade bandICS8000 verification basis
    Density at 20 °CASTM D40520.85–1.10 g/cm³Batch certificate of analysis
    Distillation rangeASTM D1078Initial boiling point ≥ 80 °C; dry point ≤ 220 °CBatch certificate of analysis
    Flash point, closed cupASTM D93Class dependent; verify SDSSafety data sheet
    Non-volatile residueASTM D135310 ppmBatch certificate of analysis
    Chloride contentIon chromatography, ASTM D43275 mg/LBatch certificate of analysis
    Trace metal cations, Na, K, Ca, MgICP-MSEach ≤ 1 mg/kgBatch certificate of analysis
    Surface tension at 25 °CASTM D133124–32 mN/mBatch certificate of analysis
    Particle count at point of fillASTM F3120.5 µm particles ≤ 100/mL; ≥ 1.0 µm particles ≤ 10/mLBatch certificate of analysis

    Material compatibility screening is required because electronic/EL grade solvent blends may contain polar cosolvents that plasticize certain acrylic solder masks. The product should be screened on coupons with ENIG, immersion silver, immersion tin, and OSP finishes. A practical screening condition is immersion at 45 °C for 2 h, followed by visual inspection at 10× for solder mask lifting, color shift, or surface dulling. If the cleaning agent is used on flexible circuits, adhesion of coverlay and stiffener adhesives should also be checked after extended immersion. In a high-volume PCB assembly line, a common failure mode observed with electronic cleaning agents is bath exhaustion caused by flux drag-out and water uptake. Water uptake above 0.5 wt% can reduce solvency for nonpolar rosin fractions and change the drying profile. Karl Fischer titration should be used to monitor water content; if the bath exceeds 1.0 wt%, the cleaning bath should be partially replaced or dried by molecular sieve filtration.

    Halide-Free Formulation and Compatibility Boundaries in Mixed-Metal Board Finishes

    Halide-free electronic cleaning agents are preferred where silver migration or copper dendrite growth is a reliability concern. The absence of chloride and bromide in the formulation is not sufficient to guarantee low halide contamination on the board; the rinse equipment and rinse water must also be controlled. In mixed-metal finishes, the cleaning agent should not create a galvanic cell between ENIG pads and exposed copper sidewalls. Compatibility tests should include electrochemical migration testing at 85 °C and 85% RH with 50 V bias for 500 h using the assembled board or a representative interdigitated coupon. Published data for ICS8000 in this specific test configuration is limited; therefore, the user should generate lot-specific data for each finish stack.

    OSP-coated copper is vulnerable to aggressive solvent blends that chelate the organometallic film or dissolve the protective layer. If the cleaning agent contacts OSP-finished boards, the OSP film thickness should be measured before and after cleaning using UV-Vis absorbance or X-ray fluorescence; a loss greater than 25% relative to the pre-cleaning value indicates an incompatible process. Immersion silver and immersion tin can develop sulfide or oxide tinting if the cleaner is contaminated with copper ions or if the rinse water contains dissolved oxygen; nitrogen-blanketed rinse tanks are used where necessary. In immersion silver processes, the cleaning bath should be monitored for copper concentration below 5 mg/L to avoid galvanic displacement reactions that degrade the finish.

    When Ionic Residue Limits Tighten Below 1.56 µg NaCl/cm²

    The IPC J-STD-001H default cleanliness objective for high-impedance and high-voltage assemblies is 1.56 µg NaCl/cm² equivalent. This value is measured by resistivity of solvent extract using IPC-TM-650 2.3.25 with an alcohol-water extract solution. For assemblies that must meet this limit, the ICS8000 cleaning process is typically qualified with a three-bath sequence: first-stage cleaning agent with ultrasonic energy, second-stage rinse with deionized water, and third-stage hot-air drying at 70–90 °C for 10–15 min. The final rinse water should be monitored for conductivity and total organic carbon; typical setpoints are ≤ 1 µS/cm and ≤ 0.5 mg/L TOC for the top-up water.

    Ion chromatography of extracted residues provides speciation data that ROSE cannot provide. If the ROSE value passes but ion chromatography shows residual weak organic acid anions above 2 µg/cm², cleanroom surface insulation resistance may degrade under humid conditions. The cleaning process should therefore be characterized by both ROSE and ion chromatography during initial validation. The extraction volume for ROSE should be normalized to the board surface area; a common reference is 100 mL extractant per 100 cm² board area equivalent, with exact values calculated per the method. Shelf-life of the cleaning bath is not indefinite; drag-out of flux residues accumulates and raises the non-volatile residue of the bath even if the solvent phase remains clear. Bath replacement is typically triggered when the non-volatile residue of the bath exceeds 500 ppm or when the rinse water ionic load reaches a predetermined control limit.

    Drying Parameters and Rinse Water Quality Are Process-Coupled

    Rinsing is not a dilution step; it is a mass-transfer operation that displaces the contaminated solvent film from the board surface. For electronic/EL grade cleaning agents with flash points above 21 °C, the rinse stage can be operated at ambient temperature, but the final hot-air drying stage should be configured with high extraction airflow. A typical convection oven setting for high-density assemblies is 70–90 °C for 10–15 min with airflow ≥ 15 air changes/min. For assemblies with moisture-sensitive components, the drying temperature should not exceed the moisture sensitivity level limit specified in IPC/JEDEC J-STD-033C for the component package.

    Incomplete drying leaves a solvent-water film that can cause conformal coating adhesion loss or white spot formation. The drying stage should be validated by gravimetric or gas-chromatographic measurement of residual solvent on the board surface. If residual water is suspected, Fourier transform infrared spectroscopy can detect the O-H stretch band at approximately 3200–3600 cm⁻¹ on the board surface. Compressed air used for blow-off should be filtered to 0.01 µm and oil-free; otherwise particulate contamination from the air line can settle on the wet board surface. The final board should be processed within a controlled humidity environment not exceeding 60% RH to avoid rehydration of solder mask and flux residues.

    Compared with isopropanol or ethanol cleaners, electronic/EL grade PCB cleaning agents are typically filtered through 0.2 µm or smaller membranes and packaged in cleanroom-compatible containers to avoid particle shedding. The difference is not simply solvency but post-cleaning ionic cleanliness. Isopropanol evaporates rapidly and can redeposit rosin fractions or leave halide salts at the edge of the cleaning area; electronic/EL grade blends are formulated to keep dissolved residues in solution until the rinse stage removes them. Compared with halogenated solvent degreasers, the PCB special cleaning agent presents a different toxicological and residue profile; however, the user must verify the SDS for flash point, exposure limit, and ventilation requirements before replacing an existing vapor degreaser. Replacement of isopropanol with ICS8000 in existing cleaning equipment should not proceed without a compatibility review of pump seals, gaskets, and filter elements. Polypropylene, PTFE, and stainless steel are generally acceptable, but Buna-N seals may swell in solvent blends.

    Table 2. Comparative process boundaries for common PCB cleaning product classes
    Product classPrimary removal mechanismFlash point classIonic residue riskTypical application boundary
    Anji Microelectronics ICS8000 electronic/EL gradeSolvent dissolution, ultrasonic/mechanical displacement, rinseVerify SDS; class dependentControlled by low NVR ≤ 10 ppm and trace-metal gradeHigh-density PCB, no-clean flux removal, pre-coating
    Isopropanol / ethanolPolar dissolution and fast evaporationLow flash point, typically ˂ 13 °CMay redeposit rosin and leave halide saltsLight oil removal; not robust for crosslinked no-clean flux
    Halogenated solventAggressive solvency, vapor degreasingNonflammable but low exposure limitsHigh if not rinsed; residue may affect solderabilityHeavy oils/waxes; generally not used for water-sensitive OSP boards
    Aqueous saponifierAlkaline saponification of rosinNonflammableHigh if rinse volume or pH control is inadequateWater-tolerable assemblies; larger boards without water-sensitive components

    Storage conditions for electronic/EL grade cleaning agents are critical because moisture absorption and particulate ingress alter the formulation. The product should be stored at 5–35 °C in a dry, ventilated area. Containers should be resealed immediately after dispense. Shelf-life after opening is controlled by the user; if the water content exceeds 0.5 wt% by Karl Fischer titration, the material should not be used for high-density board cleaning without drying or replacement.

    The operational boundary for the product includes restrictions on direct application to energized equipment and exclusion from closed electronic enclosures unless the solvent has been removed by drying. The product should not be mixed with amine-based additives or strong oxidizers unless compatibility data are available, because exothermic reactions or phase separation may occur. Waste solvent and rinse effluent are managed according to local hazardous waste regulations; the halogen-free formulation does not automatically permit disposal into municipal wastewater without treatment. The material is intended for industrial printed circuit board cleaning processes, not for consumer or household use.