Low-R Series

    • Product Name: Low-R Series
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: admin@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    Specifications
    HS Code 103613
    Product Name Low-R Series
    Product Type Low Resistance Current Sense Resistor
    Resistance Range 1 mΩ to 1 Ω
    Tolerance ±1%, ±2%, ±5%
    Temperature Coefficient ±50 ppm/°C to ±100 ppm/°C
    Power Rating 0.1 W to 3 W
    Operating Temperature Range -55 °C to +155 °C
    Mounting Type Surface Mount
    Package Style SMD chip (0603, 0805, 1206, 2512, etc.)
    Termination Nickel barrier with tin-plated solder
    Compliance RoHS Compliant
    Typical Application Current sensing, power monitoring, battery protection

    As an accredited Low-R Series factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Low-R Series is packaged in sealed 25 kg drums, with durable, labeled containers ensuring safe handling, transport, and storage stability.
    Container Loading (20′ FCL) 20′ FCL shipment of Low-R Series chemicals: containerized, safe, sealed loading for efficient, cost-effective bulk transport.
    Shipping Low-R Series chemicals are shipped in UN-approved, leak-proof containers with proper hazard labeling and secure cushioning. Transport follows strict temperature, handling, and segregation protocols to maintain product integrity and safety. Full documentation, including SDS and chain-of-custody, accompanies each shipment. Expedited and tracked delivery options are available upon request.
    Storage Store Low-R Series chemicals in tightly sealed, original containers in a cool, dry, well-ventilated area. Keep away from direct sunlight, heat, ignition sources, and incompatible materials. Ensure containers remain upright and labels are intact. Use appropriate PPE during handling and storage operations. Regularly inspect for leaks or damage, and follow all local chemical storage regulations.
    Shelf Life Shelf life is typically 12 months from manufacture when stored sealed, cool, and dry in original container.
    Application of Low-R Series

    Processing of glass-filled polypropylene antistatic enclosures on a 40:1 L/D co-rotating twin-screw extruder requires the Low-R series carbon-based conductive particulate to be side-fed after the first kneading block. Let-down ratios from 3 wt% to 8 wt% are maintained by gravimetric feeders calibrated to ±0.5%. Screw speed is limited to 400–600 rpm; melt temperature is kept between 190 °C and 230 °C. At 8 wt% loading with 20 wt% short glass fiber, surface resistivity falls from greater than 10^12 Ω/sq for the unreinforced base resin to 10^5–10^7 Ω/sq when tested at 23 °C and 50% RH. Volume resistivity is assessed by ASTM D4496-21 using sheet electrodes and by ASTM D257-14 with a concentric ring fixture. Compliance with IEC 61340-5-1:2016 requires surface resistance below 1×10^9 Ω for grounded personnel protection. Field observations on injection molding lines with clamp forces between 1,200 kN and 3,000 kN show that gate freeze-off must be delayed by 0.5–1.0 s or flow marks develop in high-let-down formulations. The conductive network is shear-sensitive; regrind levels above 20% raise surface resistivity by up to one decade because the particulate network fractures during secondary mixing. Pre-drying of the polymer is mandatory at 80 °C for 2 h when ambient relative humidity exceeds 60%, and machine hold-up time should not exceed 4 min above 230 °C. The series is incompatible with zinc stearate levels above 0.5 phr in the same masterbatch because the lubricant film coats the conductive surface and disrupts electron tunnelling.

    What Limits the Addition Rate in Two-Part Epoxy ESD Flooring?

    In a 100:40 amine-cured bisphenol A epoxy system, incorporation of the Low-R series at 1.5–4.0 wt% of total resin mass reduces coating surface resistance from above 10^12 Ω/sq to 10^4–10^6 Ω/sq only when the additive is pre-dispersed on a three-roll mill at 50 μm gap and 25 °C roll temperature. High-speed disperser speeds of 1,500–2,500 rpm for 15 min do not fully break down primary agglomerates; film resistivity remains above the ESD target. Viscosity increase is the limiting parameter: at 4 wt%, Brookfield RV viscosity at 25 °C rises from 1,200 mPa·s to 3,800–4,600 mPa·s, requiring a 5–10% reduction in non-reactive diluent to keep trowel flow acceptable. The mixed floor coat is applied at 250–400 μm wet film thickness; conductivity is evaluated after 72 h cure at 23 °C and 50% RH according to EN 1081:2018. Measurement electrodes placed 300 mm apart should read between 1×10^4 Ω and 1×10^6 Ω. The coating should not be applied below 10 °C substrate temperature because cure retardation traps solvent and causes discontinuous conductive pathways. Incompatibility with benzyl alcohol plasticizers above 2% has been recorded as a surface resistivity drift from 10^4 Ω to 10^6 Ω after 30 days at 60% RH. For cleanroom floor systems, ASTM F150-06 applies to floor surface resistance, and the system is cross-checked with IEC 61340-4-1:2015 for footwear and flooring combinations.

    Dispersion stageKey parameterAcceptance rangeTest method
    Three-roll millingGap and roll temperature50 μm / 25 °COptical fineness gauge
    High-speed disperserSpeed and residence time1,500–2,500 rpm / 15 minTemperature rise ≤ 5 °C
    Brookfield viscosityMixed system at 25 °C3,800–4,600 mPa·sISO 2555:2018

    Conductive Rubber Gaskets in Zone 1 Enclosure Flange Joints

    Two-roll mill compounding of NBR/PVC blends with 65 Shore A hardness uses Low-R series loadings between 5 phr and 12 phr. The additive is added after the first rubber breaking pass, with friction ratio 1:1.25 and roll temperature 45–55 °C. Scorch time measured by ASTM D2084-19a at 160 °C remains above 2 min when the loading is below 12 phr; above this loading, the minimum torque rises and the curing curve shifts by 45 s. Press-cured 2 mm sheets for gasket applications are cured at 150 °C for 12 min. Volume resistivity is measured by ASTM D991-89(2020) using a four-point probe; values for 8 phr loading are usually in the 10^3–10^5 Ω·cm range. The gasket must maintain volume resistance below 1×10^6 Ω under both 25 °C and 80 °C because ATEX and IECEx enclosures require static dissipation between flanges under thermal cycling. Acetone extraction of the cured compound for 6 h removes low-molecular-weight species and can increase volume resistivity by half a decade. The series should not be dispersed in compounds using sulfur donor cure systems above 170 °C because conductive filler reaggregation occurs and resistance becomes non-uniform across the gasket. Production batch-to-batch variance is controlled by conditioning the conductive additive at 60 °C for 2 h prior to weighing; a 12 phr compound mixed with 1.5 phr stearic acid shows less than 0.2 decade variation across 10 consecutive industrial batches.

    For polyurethane-based anti-static rollers and wheels, the Low-R series is introduced into the polyol side at 6–9 wt% via a planetary mixer operated at 40–60 rpm under vacuum of -0.09 MPa. Vacuum mixing is required because entrapped air at more than 0.5 vol% creates localized dielectric voids and surface resistivity rises above 10^9 Ω/sq. The mixed polyol is metered through a static mixer with an isocyanate index maintained between 98 and 102. Pot life at 25 °C decreases from 45 min to 20 min as loading rises from 6 wt% to 9 wt%, limiting casting windows for large polyurethane wheels. Curing at 80 °C for 16 h develops Shore A 80–90 hardness. Rubbing tests on rotating wheel assemblies at 40 rpm show that conductive surface layers must extend at least 2 mm into the part; skiving 0.5 mm from the outer surface does not expose sufficient conductive network. Resistance between wheel core and rolling surface is tested by ISO 2878:2017 for conductive rubber products, with a maximum allowable value of 1×10^6 Ω. The additive should not be combined with moisture-scavenging molecular sieves in the polyol blend because competitive adsorption reduces Low-R dispersion stability and causes sedimentation within 30 min. A production line using 1,500-L polyol tanks requires 20–25 min recirculation at 30 rpm before casting to re-establish homogeneity after overnight shutdown.

    When Low-R Grades Are Compounded into Rotomoulded HDPE Fuel Handling Components

    Rotomoulded HDPE fuel filters and tank covers require surface resistivity between 1×10^4 Ω and 1×10^6 Ω per IEC TS 60079-32-1:2013 for hazardous zones. Dry blending of the Low-R series at 4–7 wt% with 35-mesh HDPE powder is carried out in a ribbon blender for 8–12 min at 20 °C. Blade speed is kept below 40 rpm; higher speeds create fines that electrostatically cling to the mould wall and produce uneven wall thickness. The mould is heated to 250–270 °C and rotated at a 4:1 rpm ratio. Published data for the specific resistance of rotomoulded Low-R filled HDPE at wall thicknesses below 3 mm is limited; evaluation on a production machine with forced-air cooling indicates surface resistance depends strongly on the cooling rate. Slow cooling at 2 °C/min yields internal crystalline growth that pushes conductive particles into interspherulitic zones, reducing surface resistance by 0.5–1 decade compared with water-quenched parts. This is a critical processing conflict: fast cooling provides dimensional stability but reduces conductive continuity. Acceptable components are therefore cooled at 1–2 °C/min in the first 10 min, then force-cooled. Weld lines and bosses exhibit local resistance 10^2 times higher than planar walls because internal air pressure cannot re-orient the conductive network. Standard leak and drop tests remain unchanged, but static decay testing per MIL-PRF-81705D requires less than 2 s decay time from 5,000 V to 500 V. The series is not recommended for potable water liners due to extractables compliance under FDA 21 CFR 177.1520; direct food-contact positions require pre-qualification.

    Cathode Slurry Conductive Network Uniformity in NMP Systems

    Planetary mixing of NMP-based cathode slurries with LFP, PVDF binder, and the Low-R series at 2–4 wt% dry basis requires a two-stage dispersion sequence. Stage one mixes PVDF solution at 30 °C for 10 min at 60 rpm; stage two adds conductive additive and active material in alternating portions over 60 min at 100–120 rpm under 0.08 MPa vacuum. Rheological control is specified by steady-shear viscosity at 10 s^-1 between 2,000 mPa·s and 4,000 mPa·s for slot-die coating. Slurry conductivity is not a direct release criterion, but dried coating sheet resistance measured by a four-point probe on 25 μm aluminium foil typically falls between 10 Ω/sq and 50 Ω/sq for 2 wt% conductive additive when calendering pressure is 10–20 N/mm. Higher calendering pressure densifies the coating and reduces electrolyte penetration; post-calendering porosity below 25% leads to rate capability loss at 2C discharge. The dry-room environment must be maintained at dew point below -35 °C, because moisture above 200 ppm interacts with PVDF dissolution and can immobilize the conductive additive at the slurry/foil interface. Bottom-discharge planetary mixers with 300 L vessel capacity need 10–15 min post-mix vacuum degassing at -0.09 MPa; residual foam causes comma-reverse coating striations with 50 μm wavelength. Metal contamination from the series is controlled to less than 25 ppm Fe, 5 ppm Cu, and 2 ppm Co to avoid microinternal shorting. Not all Low-R grades are suitable for high-nickel cathode chemistries; qualification in NMC811 requires additional extraction testing because oxidative degradation products can raise interfacial resistance during high-temperature storage.

    ApplicationLoading rangePerformance thresholdStandard
    PP antistatic enclosure3–8 wt%Surface resistance < 10^9 ΩIEC 61340-5-1:2016
    Epoxy ESD flooring1.5–4 wt%1×10^4–1×10^6 ΩEN 1081:2018
    NBR/PVC gasket5–12 phrVolume resistivity < 10^6 Ω·cmASTM D991-89(2020)
    HDPE fuel component4–7 wt%Static decay < 2 sMIL-PRF-81705D

    For polypropylene spunbond nonwoven antistatic packaging, a 25 wt% Low-R concentrate is let down at 4 wt% into fiber-grade polypropylene; fabric surface resistivity is evaluated under ISO 18080-1:2015, with a maximum 1×10^10 Ω/sq for antistatic packaging.

    Free Quote

    Competitive Low-R Series prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618136850665 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618136850665

    Email: admin@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Low-R Series is a family of thermally conductive silicone elastomer gap fillers formulated with surface-treated boron nitride and calcined alumina. The product designation refers to low static thermal impedance rather than bulk conductivity alone. Current commercial configurations include Low-R 20, Low-R 40, and Low-R 60, with nominal post-cure thermal conductivities of 2.0 W/m·K, 4.0 W/m·K, and 6.0 W/m·K when measured according to ASTM D5470-17 at 40 psi clamping pressure. The series is supplied as die-cut pads on polyethylene terephthalate release liners in thickness grades from 0.5 mm to 5.0 mm. Manufacturing records from high-volume IGBT assembly lines indicate pad placement variance is reduced to ±0.3 mm when liner release forces are maintained between 4 gf/25 mm and 8 gf/25 mm as measured by a constant-rate tensile pull tester. Pre-drying at 80°C for 2 h is specified when storage humidity exceeds 60% RH because absorbed moisture can increase dielectric loss factor by 0.05 at 1 MHz during initial power-on.

    In comparison with general-purpose silicone thermal pads, Low-R 40 reaches 0.09 K·cm²/W at 1.0 mm under 30 psi, whereas typical formulations remain above 0.40 K·cm²/W at 1.0 mm under 20 psi. The reduction arises from bimodal filler packing and limited chain entanglement after platinum-catalyzed addition cure. Cure state is monitored by moving die rheometer at 120°C; torque profiles show M_L between 0.8 dN·m and 1.2 dN·m, M_H between 4.5 dN·m and 6.0 dN·m, and T_90 from 45 s to 60 s for 2.0 mm slab stock. Residual low-molecular-weight siloxane content is reduced below 100 ppm by post-curing in a forced-air oven at 150°C for 4 h, which limits silicone oil migration to solder mask surfaces. Batch-to-batch variance in oil bleed at 100°C for 24 h is held below 0.1% by weight when the filler premix is exposed to a three-roll mill with ceramic rolls at 40 rpm and nip clearance 15 µm. This is a critical quality parameter in automated optical inspection of populated printed circuit boards.

    During compounding, viscosity build follows a shear-thinning profile with apparent viscosity at 10 s⁻¹ from 1,200 Pa·s for Low-R 20 to 3,600 Pa·s for Low-R 60. Mixing is conducted in a sigma-blade mixer with temperature maintained below 70°C to avoid premature polymerization. The dispersion index measured by optical microscopy is less than 2.5% agglomerate area fraction for filler particles above 30 µm. This filler agglomeration limit is associated with hot-spot formation during thermal impedance testing. Compounds are degassed at 0.1 kPa until entrapped air removal is confirmed by density measurement against theoretical filler loading. Insufficient degassing produces microvoids that raise thermal impedance by 0.03 K·cm²/W at 0.5 mm bondline thickness.

    Surface treatment of boron nitride with a silane coupling agent is specified to maintain filler-polymer interfacial integrity after thermal cycling. Without treatment, interfacial debonding during 1,500 h at 125°C can increase thermal impedance by 0.04 K·cm²/W. The treated filler system also reduces moisture uptake to below 0.3% by weight after 96 h at 85°C/85% RH. This is critical for outdoor power conversion equipment where dew point cycling causes condensate film formation on insulator edges.

    What Distinguishes Low-R Series from Phase-Change Compounds in Server Processor Cooling?

    Phase-change compounds provide low initial thermal impedance after melt-flow, but their rework behavior and pump-out resistance depend on thermal cycling amplitude. Low-R Series solids eliminate pump-out but require higher assembly compression. In insert-molded socket interfaces, Low-R 60 with 1.5 mm thickness and 20% initial compression achieves a post-1000-cycle thermal impedance shift of less than 0.01 K·cm²/W when cycled from -40°C to 125°C per IEC 60749-25. The corresponding phase-change material may show void formation after 500 cycles under identical contact pressure. For edge-mounted modules with non-parallel surfaces, Low-R 20 is specified because its lower filler loading permits 40% compression without exceeding 45 psi closure force. Published data for Low-R 60 in direct-die applications under sustained 150°C and mechanical shock per IEC 60068-2-27 remain limited.

    On a 180-ton injection-molded housing line, assembly trials confirmed that Low-R 20 pads with 2.0 mm thickness required a closure speed not exceeding 5 mm/s to avoid pad shifting during module assembly. Pneumatic fixtures with 0.4 MPa line pressure provided insufficient compression for Low-R 60 at 1.0 mm; hydraulic clamps reaching 0.6 MPa were specified. Use with silicone-free thermal greases is permitted, but solvent-based fluxes should be kept from pad edges because silicone swells by 4% in contact with mineral spirits and recovers incompletely.

    PropertyTest methodLow-R 20Low-R 40Low-R 60
    Thermal conductivity (W/m·K)ASTM D5470-172.0 W/m·K4.0 W/m·K6.0 W/m·K
    Thermal impedance (K·cm²/W) at 1.0 mm and 40 psiASTM D5470-170.28 K·cm²/W0.15 K·cm²/W0.09 K·cm²/W
    Hardness (Shore OO)ASTM D2240-15355065
    Tensile strength (MPa)ASTM D412-160.5 MPa0.7 MPa0.6 MPa
    Elongation at break (%)ASTM D412-16120%80%40%
    Volume resistivity (Ω·cm)ASTM D257-141.5×1013 Ω·cm1.2×1014 Ω·cm8.0×1013 Ω·cm
    Dielectric breakdown strength (kV/mm)ASTM D149-2010 kV/mm12 kV/mm11 kV/mm
    Continuous use temperature (°C)IEC 60216-1-40°C to 150°C-40°C to 150°C-40°C to 150°C
    Flammability ratingUL 94V-0V-0V-0

    Compression-Recovery Profiling Across Low-R 20, Low-R 40, and Low-R 60

    Subsequent to constant-force relaxation at 85°C for 168 h, recovered thickness for a 1.0 mm pad subjected to 40% initial compression is 0.94 mm, 0.91 mm, and 0.88 mm for Low-R 20, Low-R 40, and Low-R 60. Compression set values determined by ASTM D395 Method B after 22 h at 100°C are 12%, 18%, and 25%. Filler loading increases with thermal conductivity, reducing chain mobility and elastic recovery. This variation requires adjustment of fastener torque specifications in power modules. On high-volume press lines, thickness tolerance after lamination is controlled to ±0.05 mm with ceramic-coated nip rolls at gap settings measured by laser micrometer before and after each run. A die-cut edge burr condition is observed when blade temperature exceeds 40°C; production records from flatbed press lines indicate edge debris falls below 0.5 mg/100 pads when blade temperature is maintained at 35°C or lower with a chiller setpoint range of 18°C to 22°C. This edge debris limit is required for pick-and-place vacuum nozzle reliability at 12,000 placements/h.

    Electrical stress tests under IEC 60243-1 show partial discharge inception voltage depends on edge radius of die-cut pads. Low-R 40 with a knife-cut edge has PDIV of 1.8 kV at 60 Hz; laser-cut edge raises PDIV to 2.6 kV due to smoother edge profile. This is relevant for busbar isolation in compact inverters where sinusoidal phase voltage reaches 600 V and creepage is limited to 6.4 mm. Surface roughness of the heatsink should be below Ra 3.2 µm; above that value thermal impedance rises by 0.02 K·cm²/W per 1.0 µm Ra increase. Published data for combined voltage and thermal cycling at 1,500 V across Low-R 60 is limited.

    RequirementStandard / regulationLow-R Series status
    Hazardous substances in electrical equipmentRoHS Directive 2011/65/EU including (EU) 2015/863Compliant for Pb, Hg, Cd, Cr(VI), PBB, PBDE, DEHP, BBP, DBP, DIBP
    Substances of very high concernREACH Regulation (EC) No 1907/2006<0.1 wt% SVHC
    Flame retardancy at 1.0 mmUL 94V-0
    Thermal impedance and conductivityASTM D5470-17Tested per datasheet method
    Dielectric breakdown strengthASTM D149-2012 kV/mm initial for Low-R 40 at 1.0 mm
    Damp heat degradationIEC 60068-2-789 kV/mm after 500 h at 85°C/85% RH for Low-R 40
    Thermal cyclingIEC 60749-25<0.01 K·cm²/W shift after 1000 cycles for Low-R 60

    When Low-R Series Replaces Mica-Based Insulators in Motor Drive Inverters

    In motor drive inverters where creepage and clearance allow a compressible pad, Low-R 40 is evaluated as a replacement for mica-based insulators. Mica is rigid; Low-R pads conform to stamped heatsink surfaces with 0.08 mm surface deviation. Thermal resistance including contact interfaces decreases from 0.55 K·cm²/W to 0.15 K·cm²/W at 25 psi. However phase-to-ground insulation requires minimum 0.5 mm thickness and dielectric strength above 10 kV/mm after 85°C/85% RH aging. Low-R 40 with 1.0 mm thickness meets 12 kV/mm initial but drops to 9 kV/mm after 500 h damp heat per IEC 60068-2-78; therefore design margin is set at 0.8 mm for 690 V class drives. Incompatibility with liquid metal thermal interface materials is documented: gallium-containing formulations degrade the silicone network and reduce tensile strength by more than 30% within 200 h at 80°C. Avoid combination with amine-based adhesion promoters because they inhibit platinum cure during manufacture. For framed packages, compression force at 25% deflection shall not exceed 120 N per 1000 mm² pad area; exceeding this value induces lateral creep into wirebond regions.