| HS Code | 322554 |
| Dielectricstrength Kv Per Mm | 15-30 |
| Thermalstability Degc | Up to 180 |
| Insulationresistance Ohm Cm | 1e14 - 1e16 |
| Adhesion | Excellent to substrates and copper |
| Viscosity Cp | 500 - 5000 |
| Curingtemperature Degc | 120 - 200 |
| Moistureresistance | High |
| Chemicalresistance | Resistant to solvents and fluxes |
| Dissipationfactor At 1khz | 0.001 - 0.01 |
| Dielectricconstant | 3.0 - 4.0 |
As an accredited Insulation Coating Material Electronic/EL Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Packaged in sealed, clean containers to prevent moisture and contamination; available in 1 kg, 5 kg, and 20 kg quantities. |
| Container Loading (20′ FCL) | EL-grade insulation coating in sealed drums is palletized, secured, and loaded into 20′ FCL to ensure safe transport and purity. |
| Shipping | Our electronic-grade insulation coating ships in sealed, moisture-resistant containers to preserve purity. Transport follows standard hazardous material regulations, avoiding extreme temperatures and direct sunlight. Ground shipping is standard; air freight available with proper documentation. Each batch includes MSDS and certificate of analysis to ensure safe handling and compliance throughout transit. |
| Storage | Store in a cool, dry, well-ventilated area away from heat, sparks, open flames, and direct sunlight. Keep the container tightly sealed to prevent moisture absorption and contamination. Avoid contact with strong oxidizers and incompatible materials. Use explosion-proof equipment and ground containers when transferring. Maintain stable temperatures to preserve purity and performance. |
| Shelf Life | Shelf life is typically 12 months when stored sealed in a cool, dry area away from sunlight and moisture. |
In high-density printed circuit assembly, electronic/EL grade insulation coating is specified when creepage distances on FR-4 substrates fall below 0.2 mm between adjacent pads and flux residues must be immobilised under humid bias. A low-viscosity acrylic electronic-grade formulation, supplied at 30–35 wt% solids in a butyl acetate/2-propanol blend, is thinned with butyl acetate at a ratio not exceeding 10 parts by weight thinner to 100 parts by weight stock to maintain Brookfield RV viscosity between 20–50 mPa·s at 25 °C. Selective robotic coating equipment, such as a Nordson ASYMTEK Spectrum II or PVA Delta 8, is programmed with a valve speed of 150–300 mm/s, a nozzle standoff of 8–12 mm, and a fluid pressure of 0.7–1.2 bar. The wet film is deposited at 50–100 µm; after thermal cure at 60–80 °C for 10–20 min, dry film thickness is held at 25–75 µm per IPC-CC-830B. Surface insulation resistance is evaluated per IPC TM-650 2.6.3.7 using 50 V DC bias at 85 °C/85% RH; the pass criterion is 1.0 × 108 Ω maintained over 168 h. Ionic cleanliness is verified by ion chromatography per IPC TM-650 2.3.28, with chloride <5 ppm, sodium <5 ppm, and total halogens <50 ppm to minimise electrochemical migration on 0.4 mm pitch ball grid arrays. Edge coverage on quad flat no-lead packages remains process-critical: coatings with equilibrium surface tension above 28 mN/m dewet from solder mask dams of 100–150 µm height, producing corner dry film thickness below 10 µm. Two-pass application with intermediate flash-off at 40 °C for 3 min is required when the first wet pass exceeds 75 µm; single-pass deposition above that threshold generates solvent-pop microvoids visible at 200× magnification. The cured acrylic layer is qualified for continuous operating temperature up to 130 °C under UL 746B; for higher thermal classes, polyurethane or silicone electronic-grade coatings are substituted, with dry nitrogen or argon blanketing during storage to avoid a 10–20% viscosity rise at 25 °C after 30 days in unsealed containers. Finished assemblies include smart-meter control boards, industrial power supply modules, and servo drive logic boards.
For hairpin stator impregnation, slot fill factor above 85% and void content below 2 vol% are the primary acceptance targets in 180–220 mm stack lengths. A two-component epoxy electronic-grade system is mixed at 100:30 by weight resin-to-hardener and degassed at 1–5 mbar for 10 min before being transferred to a trickle impregnation head. The stator is preheated to 60–70 °C to lower resin viscosity to 80–150 mPa·s at the winding surface; when bath viscosity exceeds 200 mPa·s at 40 °C, slot penetration in the middle of the stack drops and void content rises to 4–6 vol% in cross-sectioned parts. Trickle flow rate is set at 0.5–1.5 L/min with rotation at 20–60 rpm for 10–20 min; gel time at 120 °C is typically 5–8 min, and final cure at 150 °C for 30–60 min develops dielectric strength above 20 kV/mm per ASTM D149. Vacuum pressure impregnation is specified when the stator slot fill is below 80% after trickle processing or when inverter switching frequencies exceed 20 kHz; the process uses a vacuum of 50–100 mbar followed by pressure of 3–5 bar in a Hedrich or Hübers VPI vessel. The table summarises the two process windows.
| Parameter | Trickle impregnation | Vacuum pressure impregnation |
|---|---|---|
| Resin bath temperature | 40–60 °C | 25–40 °C |
| Stator preheat temperature | 60–70 °C | 40–50 °C |
| Viscosity at application | 80–150 mPa·s | 200–500 mPa·s |
| Cycle time | 10–20 min | 45–90 min |
| Void content after cure | 2–4 vol% | <2 vol% |
For 800 V inverter-fed machines, partial discharge inception voltage is evaluated per IEC 60034-18-41; acceptance thresholds are system-specific and published data for generic electronic/EL grade single-component formulations in production hairpin windings is limited. The impregnated stator is qualified under UL 1446 as part of an insulation system at thermal class 180 °C for polyesterimide and 200 °C for epoxy-anhydride systems. Incompatibility arises with amine-based accelerators added to lower cure temperature; amine residues increase dissipation factor above 0.02 at 155 °C after 500 h thermal ageing. The finished end product is a traction motor stator for battery-electric vehicles or industrial servo motors.
When high-frequency toroidal cores with ferrite core outer diameters between 10 mm and 25 mm are dip-coated, edge coverage on the outer radius is controlled by thixotropic index rather than initial viscosity. A single-component epoxy electronic/EL grade material with Brookfield viscosity 500–1,000 mPa·s at 25 °C and a thixotropic index of 2.5–3.5 is held in a dip tank at 20–25 °C with continuous low-shear mixing at 10–20 rpm. Cores are immersed for 5–10 s, withdrawn at 50–100 mm/min, and rotated through 90° every 30 s during flash-off to prevent edge build-up. Dry film thickness of 50–150 µm is measured on the flat side of the core by eddy current gauge. Edge coverage on the outer radius of 2–4 mm remains the limiting requirement: when withdrawal speed exceeds 100 mm/min, capillary drainage from the toroid inner diameter creates a meniscus that raises edge thickness above 200 µm and produces stress cracks after cure at 125 °C for 1 h. The cured coating must meet UL 94 V-0 at 0.5 mm thickness and IEC 61558-1 creepage requirements for reinforced insulation when the wound component operates at 600 V working voltage. Salt-spray exposure per ASTM B117 for 96 h on post-cured parts shows no corrosion of copper windings when the coating is free of pinholes; pinhole density below 1/cm² is verified by high-voltage pinhole testing at 1.5 kV AC. The terminal component is a common-mode choke for switch-mode power supplies or a gate-drive transformer for isolated converters.
For outdoor LED driver boards, electronic/EL grade encapsulation must combine moisture exclusion with low stress on aluminium-core substrates. A two-component silicone gel with mixed viscosity 800–1,500 mPa·s at 25 °C is dispensed into a polycarbonate housing at a fill volume of 70–85% of cavity height, leaving 2–3 mm headspace for thermal expansion. The material is cured at 100 °C for 15 min followed by 150 °C for 1 h; cured hardness is 60–80 Shore 00 and tensile modulus is below 10 MPa per ASTM D412, preventing solder-joint stress on metal-core printed circuit boards during thermal cycling from -40 °C to 105 °C per IEC 60068-2-14. Optical clarity is not a primary requirement for driver encapsulation, but the coating is specified with UV stabilisers and tested per ASTM G154 for 500 h; yellowness index per ASTM E313 increases by less than 5 points. Flame resistance is verified to UL 94 V-0 at 2 mm, and outdoor suitability is supported by UL 746C f1 exposure for 720 h UV-water cycling. Process control includes vacuum defoaming at 20–50 mbar for 5 min to reduce bubbles larger than 0.5 mm in the uncured liquid; entrapped bubbles at the aluminium substrate interface cause partial discharge sites in luminaires operating at 700 V DC. The terminal assembly is an IP66-rated street luminaire driver or high-bay LED power supply.
On automotive engine-control modules, electronic/EL grade polyurethane conformal coating is applied where the assembly must survive 1,000 thermal shock cycles from -40 °C to 125 °C per ISO 16750-4. Before coating, the printed circuit board is exposed to in-line atmospheric plasma with a process gap of 10–12 mm and travel speed of 50–80 mm/s, raising surface energy above 62 mN/m as checked by contact-angle test inks. The coating is dispensed with selective spray equipment at dry film thickness 25–50 µm; wet film thickness is adjusted for 40–50 wt% solids in propylene glycol methyl ether acetate. After moisture-cure at 25 °C/50% RH for 72 h or forced cure at 80 °C for 2 h, adhesion is tested per ASTM D3359 cross-cut tape pull and must remain grade 5B after thermal shock. CTE mismatch is the dominant stress driver: the cured polyurethane exhibits a glass transition below 5 °C and a coefficient of linear thermal expansion of 80–120 ppm/°C, whereas FR-4 expands at 14–17 ppm/°C; polymer chain mobility below 5 °C reduces stress relief and causes corner delamination on ceramic chip capacitors if thickness exceeds 75 µm. Chemical resistance is validated by immersion in test fluids per ISO 2812-1 at 60 °C for 24 h; visual blistering and loss of adhesion beyond 1 mm from scribe lines constitute failure. Salt spray resistance per ASTM B117 for 96 h is required when the ECU is mounted in wheel arches or chassis zones. The terminal product is an ECU for fuel injection, transmission control, or battery management in 48 V mild-hybrid systems.
In wearable biometric monitoring, flexible hybrid assemblies use electronic/EL grade silicone or urethane coatings that must deform with polymeric substrates without cracking. A platinum-catalysed addition-cure silicone with durometer 20–30 Shore A and elongation at break above 150% per ASTM D412 is screen-printed or stencil-printed at 25–50 µm dry film over silver-flake conductors on polyimide or thermoplastic polyurethane substrates. The material is cured at 80–100 °C for 30 min; moisture-permeable formulations are not used because silver migration under sweat contact can develop at 3 V DC bias in 24 h when chloride contamination exceeds 10 µg/cm². Dynamic flex testing is performed on a 5 mm bend radius at 1 Hz for 100,000 cycles per IPC TM-650 2.4.3; the pass criterion is resistance change of the covered conductor below 1%. The cured coating is qualified for skin-contact biocompatibility per ISO 10993-5 and ISO 10993-10 only if the module is intended for direct dermal contact; otherwise those tests are not part of the electrical insulation qualification. Volume resistivity after 85 °C/85% RH conditioning is verified above 1.0 × 1012 Ω·cm per ASTM D257. The terminal component is a flexible ECG electrode patch or a stretchable printed heater for rehabilitation garments.
Silicon carbide power modules for 1,200 V blocking voltage demand electronic/EL grade silicone gel coatings that suppress partial discharge at metallic triple points on direct-bonded copper substrates. The gel is a two-component addition-cure silicone with mixed viscosity 500–1,000 mPa·s at 25 °C and is degassed at 10–20 mbar for 10 min before dispensing into a module frame. It is applied at a thickness of 3–6 mm over wire-bonded SiC MOSFET dies and cured at 100 °C for 15 min followed by 150 °C for 1 h; post-cure hardness is 40–60 Shore 00, and the low modulus prevents wire-bond lift-off under 150 °C temperature swings in active power cycling. Dielectric strength is tested on cast sheets per ASTM D149 and is typically above 18 kV/mm; volume resistivity remains above 1.0 × 1014 Ω·cm per ASTM D257 after 1,000 h at 200 °C. Outgassing for hermetically capped modules is controlled by ASTM E595, with total mass loss below 1% and collected volatile condensable material below 0.1% to avoid optical window fogging in sealed housings. Partial discharge inception voltage is measured on assembled modules per IEC 60270 with 50 Hz AC at 1.2 kV and 1.5 kV test levels; the gel must remain discharge-free at 1.2 kV when needle-plane electrode spacing is 2 mm. Failures occur when the base resin has absorbed moisture above 200 ppm prior to cure, producing micron-scale voids that increase discharge intensity by 10–20 dB in phase-resolved partial discharge mapping. The terminal module is used in traction inverters, solar string inverters, and industrial motor drives.
Competitive Insulation Coating Material Electronic/EL Grade prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8615365186327
Email: admin@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
For applications demanding low extractable ion content and high comparative tracking index on copper busbar edge radii, stator winding overhangs, or printed circuit board edge sealing, Insulation Coating Material Electronic/EL Grade is supplied as a one-component, solventborne modified epoxy-phenolic coating. The product is formulated with a solids content of 36 ± 2% by weight per ISO 3251:2019 and a viscosity of 35–55 s Ford cup No. 4 at 25 °C. Cured films are intended for dry-film thickness of 25–40 µm per coat, with 2–4 coats applied on busbar edge radii below 8 mm. The controlling specification threshold is a maximum total chloride content of 10 ppm after cure determined by ion chromatography; this distinguishes EL grade from general-purpose electrical paints, which may contain 50–500 ppm residual ionic material.
The principal performance boundary is the level of extractable ionic contamination. General-purpose alkyd and acrylic coatings may retain residual sodium, potassium, or ammonium ions in the 50–500 ppm range after cure, whereas the electronic/EL grade is filtered and reacted to hold total extractable ion content below 10 ppm when tested by IEC 62631-3-1 extraction and conductivity methods. This difference is critical for creepage-stressed surfaces: ionic species promote water uptake and conductive paths under humidity and DC bias. In addition, the electronic/EL grade is formulated to achieve a comparative tracking index of at least 600 V under IEC 60112:2020, while conventional alkyd insulating paints commonly fail below 400 V in the same test. The cured film also displays a volume resistivity of 1×1015 Ω·cm at 23 °C and 50% RH per ASTM D257-14, approximately one to two orders of magnitude higher than plasticized acrylic conformal coatings.
The material is suitable for application by dip, flow coating, and selective spray. For dip coating of copper busbars, the bath viscosity must be maintained between 35 s and 55 s Ford cup No. 4; when ambient evaporation raises viscosity above 55 s, addition of the manufacturer-specified aromatic hydrocarbon thinner is limited to 5 wt% per batch to avoid disturbing the nonvolatile balance. A wet-film thickness of 60–80 µm per dip typically deposits 25–35 µm dry film after flash-off. The flash-off interval at 25 °C is 15–20 min before forced-air curing; components with intricate slots require extension to 30 min to prevent solvent entrapment. Cure schedule for full polymerization is 120–150 °C for 2 h, with an accelerated schedule of 180 °C for 45 min used only where substrate mass does not exceed 5 kg because thermal lag in heavy copper lowers actual film temperature.
Dry-film dielectric breakdown strength is measured according to IEC 60243-1:2013 using 6.35 mm diameter electrodes and a 0.5 kV/s voltage ramp. On polished copper panels coated at 30 µm, the cured material yields 18–22 kV/mm; on edge radii below 2 mm the local thickness is lower and the same test geometry can produce 12–15 kV/mm, which must be accounted for in busbar insulation design. After 96 h exposure at 40 °C and 95% RH, dielectric strength typically declines by 15–20%, but the electronic/EL grade retains 15 kV/mm or higher under these conditions. Tracking resistance, assessed with 0.1% ammonium chloride electrolyte solution in IEC 60112:2020, produces a CTI of ≥600 V for a 35 µm film.
| Property | Test Method | Condition | Typical Value |
|---|---|---|---|
| Viscosity | ASTM D1200-18 | 25 °C, Ford cup No. 4 | 35–55 s |
| Nonvolatile content | ISO 3251:2019 | 105 °C, 3 h | 36 ± 2% |
| Density | ISO 2811-1:2021 | 25 °C | 0.98–1.02 g/cm³ |
| Dielectric strength | IEC 60243-1:2013 | 30 µm dry film, 0.5 kV/s | 18–22 kV/mm |
| Volume resistivity | ASTM D257-14 | 23 °C, 50% RH | 1×1015 Ω·cm |
| Comparative tracking index | IEC 60112:2020 | 35 µm on glass | ≥600 V |
| Thermal class | UL 1446 | Class F recognition | 155 °C |
For operation in thermally classed systems, the cured film is recognized under UL 1446 for Class F (155 °C) insulating systems when applied over tested substrates. On copper, the bond strength after 24 h at 155 °C retains more than 80% of initial lap-shear value when measured by ASTM D1002-10. Thermal aging at 180 °C for 500 h produces a weight loss of 2–4% and a reduction in dielectric strength of less than 25%; this is acceptable for Class F service but does not constitute Class H (180 °C) qualification. The coating should not be used as a sole insulation at continuous operating temperatures above 155 °C or in direct contact with silver-plated substrates unless adhesion testing has been performed according to ASTM D3359-17 tape pull methods.
When CTI compliance is required as part of a double-insulated switchgear assembly, the selection of the electronic/EL grade changes creepage clearance calculations under IEC 60664-1:2020. With a CTI of ≥600 V, the surface is classified as Material Group I, allowing a reduction in creepage distance relative to Material Group IIIa or IIIb coatings that display CTI values from 175 V to 400 V. For a working voltage of 400 V rms at pollution degree 2, the creepage distance for reinforced insulation according to IEC 60664-1:2020 Table F.4 is 6.3 mm for Material Group I, compared with 10.0 mm for Material Group IIIb. This reduction is available only if the coated surface is verified for CTI on the actual substrate, because porosity and edge coverage can lower the measured tracking performance below the values determined on glass plates.
Chemical resistance of the cured film is relevant where board assemblies are exposed to no-clean flux residues, isopropyl alcohol cleaning, or occasional mineral oil splash. After 168 h immersion in ASTM D115 oil at 105 °C, the coating remains free of blistering, softening, and cracking. Exposure to isopropyl alcohol for 24 h at 23 °C produces a 2–4% weight uptake and a 10% reduction in dielectric strength, which is considered acceptable for service. However, exposure to methyl ethyl ketone, acetone, or strong alkaline strippers dissolves or delaminates the coating; rework should use mechanical abrasion or selected solvent blends validated by the manufacturer. The material is incompatible with ambient-cure amine-based adhesives applied directly over the uncured surface because free amine can initiate premature crosslinking at the interface, producing a chalk-like boundary layer.
Adhesion is verified by cross-cut tape pull according to ASTM D3359-17, with a minimum rating of 4B on degreased copper and 3B on polyester powder-coated laminate after 24 h at 23 °C. When components are subjected to thermal cycling between −40 °C and 155 °C with 30 min dwells for 50 cycles, the coating does not crack or delaminate on flat areas; edge radii below 2 mm may show microcracking above 100 cycles, and published data for this specific configuration is limited. The observed failure mode on production-scale dip lines is edge pullback during cure from excessive wet-film thickness above 80 µm per coat, which produces solvent boil at 120 °C and should be corrected by reducing withdrawal speed rather than increasing oven temperature.
| Parameter | Electronic/EL Grade | General-purpose alkyd insulating paint | Acrylic conformal coating |
|---|---|---|---|
| Comparative tracking index | ≥600 V | 250–400 V | 300–600 V |
| Volume resistivity | 1×1015 Ω·cm | 1×1013–1×1014 Ω·cm | 1×1013–1×1015 Ω·cm |
| Extractable ion content | <10 ppm | 50–500 ppm | 20–200 ppm |
| Thermal class | 155 °C Class F | 105–130 °C | 105–125 °C |
| Oil immersion resistance | Pass 168 h at 105 °C | Blistering by 72 h | Softening by 24 h |
Storage stability is 12 months in unopened containers at 5–30 °C. At storage below 5 °C the resin may show viscosity increase; the material must be restored to 20–25 °C and mixed by low-shear propeller agitation for 30 min before use. At application sites with relative humidity above 60%, pre-drying of the substrate at 60–80 °C for 30 min is required to prevent blushing and adhesion loss. The product is supplied in 20 L pails and 200 L drums with a maximum batch-to-batch viscosity variance of ±5 s. Continuous dip-tank operation requires periodic replenishment with fresh material and densimetric monitoring to control resin depletion; a density outside 0.98–1.02 g/cm³ at 25 °C indicates solvent imbalance.