| HS Code | 899462 |
| Product Name | Hypochlorous Acid Electronic/EL Grade |
| Chemical Name | Hypochlorous acid aqueous solution |
| Chemical Formula | HOCl |
| Molecular Weight | 52.46 g/mol |
| Cas Number | 7790-92-3 |
| Grade | Electronic/EL (high-purity semiconductor grade) |
| Appearance | Clear, colorless to slightly yellow liquid |
| Odor | Slight chlorine-like odor |
| Concentration | 5-15% available HOCl (typical for electronic grade) |
| Ph | 5.0-7.0 |
| Density | 1.00-1.05 g/cm3 at 20°C |
| Boiling Point | Approximately 100°C in aqueous solution; decomposes before boiling |
| Freezing Point | Approximately -5°C to -10°C, concentration dependent |
| Solubility | Fully miscible with water |
| Stability | Decomposes under heat, UV light, and in contact with metal ions |
| Storage Temperature | 2-8°C in a cool, dark, ventilated area |
| Shelf Life | 3-6 months when properly stored |
| Trace Metals | Controlled to ultra-low levels (typically below ppb) |
| Chloride Content | Ultra-low, controlled per electronic-grade specifications |
| Particle Content | Filtered to electronic-grade cleanliness requirements |
As an accredited Hypochlorous Acid Electronic/EL Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Supplied in 25 L HDPE drums with tamper-evident seals, inert linings, and nitrogen purge to maintain electronic-grade purity. |
| Container Loading (20′ FCL) | 20′ FCL loaded with palletized, sealed drums of Electronic/EL Grade Hypochlorous Acid, properly secured, labeled, and segregated for safe transport. |
| Shipping | Shipped as UN 3264 Corrosive Liquid, Acidic, Inorganic, N.O.S. (hypochlorous acid solution), Class 8, PG II/III. Packaged in UN-certified HDPE drums or jerricans with vented closures. Labeled corrosive; segregated from alkalis and reactive metals. Protected from heat and sunlight. Ground transport requires hazard placards, emergency response documentation, and spill containment. |
| Storage | Store Hypochlorous Acid Electronic/EL Grade in tightly sealed, clean high-purity containers, preferably in a cool, dark, well-ventilated area between 5–25°C. Protect from light, heat, and contamination. Keep away from incompatible materials, including strong acids, bases, reducing agents, and organic compounds. Do not freeze. Inspect regularly and use within shelf-life limits to maintain electronic-grade purity. |
| Shelf Life | Shelf life is typically six months when stored properly in a cool, dark, tightly sealed container. |
Metered injection of Hypochlorous Acid Electronic/EL Grade into single-wafer spin cleaning systems at 10 mg/L to 30 mg/L free available chlorine, controlled to a pH envelope of 5.2–5.8 and 22–25 °C, is used for oxidation of post-ashing acrylate and methacrylate residues on 300 mm silicon before shallow trench isolation liner deposition and after low-k etch residue removal. The feed stream is prepared from 1,000 mg/L stock diluted at 1:100 to 1:20 v/v in UPW, then filtered through a 0.05 μm PFA point-of-use filter into water having resistivity ≥18.2 MΩ·cm at 25 °C, total organic carbon <1 μg/L, and dissolved oxygen <2 μg/L. Oxidation is delivered as a puddle or spray on a spin processor at 500–1,500 rpm, with chemical exposure of 30–90 s, followed by a two-stage UPW rinse of 1.5–2.5 L/min and megasonic energy 0.8–1.2 W/cm² at 1.0 MHz. Residual chloride after spin-dry is specified at ≤1×1010 atoms/cm² by time-of-flight secondary ion mass spectrometry, and trace metal extractables for Na, K, Ca, and Fe are controlled below 100 ng/L according to SEMI C1 analytical guidance. Process excursions above pH 6.5 increase the hypochlorite anion fraction and can produce pitting on exposed Al-Cu bond pads if benzotriazole passivation is incomplete; excursions below pH 5.0 shift the chlorine equilibrium so that Cl₂ off-gassing exceeds 0.1 ppm at the process bowl, requiring local exhaust verification. The finished wafer is suitable for subsequent gate oxide growth or barrier metal deposition only when final surface chloride remains below the specified threshold and no organic residue is detected by laser scanning at 0.09 μm sensitivity.
In flat-panel display lines running G8.5 or G10.5 glass, dilute hypochlorous acid of Electronic/EL grade is injected into a horizontal conveyorized wet cleaning station at 5 mg/L to 15 mg/L FAC, prepared by 1:200 to 1:66 dilution of 1,000 mg/L concentrate, at pH 4.8–6.2 and 35–45 °C, immediately before photoresist coating. The station operates brush and ultrasonic modules; the HOCl step is sprayed at 0.3–0.5 MPa through fan nozzles at a flow of 4–8 L/min per workable glass width, with contact time of 20–40 s. The process targets adsorbed organic films on indium tin oxide and on surrounding glass after edge grinding and washing, because a residual carbon layer above 0.3 μg/cm² as measured by UV-ozone contact-angle shift produces resist adhesion non-uniformity. Incoming chemical is controlled for Na, Mg, Al, K, Ca, and Fe by ICP-MS at ≤1 μg/L each, with particles ≥0.2 μm fewer than 10 particles/mL. Anion residue after the final deionized water rinse is checked by ion chromatography per ISO 10304-1:2007; surface chloride should remain below 0.5 ng/cm² to avoid formation of indium chloride complexes at the subsequent hot-plate bake. Below pH 4.8, indium oxide dissolution increases sharply in bench tests, and published data for this specific configuration is limited; therefore the lower pH stop is treated as a hard interlock. Finished substrates enter the photolithography cell as cleaned TFT backplanes for liquid-crystal display or organic light-emitting diode frontplanes.
Biofilm eradication in semiconductor ultrapure water storage and reverse osmosis permeate distribution loops uses low-dose shock sanitation with HOCl at 0.5–1.0 mg/L FAC, prepared by 1:2,000 to 1:1,000 dilution from 1,000 mg/L stock, at pH 5.5–6.0 and 22–30 °C. The loop is configured for recirculation at 1.5–2.0 m/s to prevent spiral-type reverse osmosis elements from being exposed to stagnant chemical; permeate-side flush is used while the concentrate side is isolated, or membranes are sanctioned only after review of polyamide tolerance. Sanitization contact is held for 60–120 min, after which the system is drained and rinsed with 60 °C UPW until DPD residual chlorine falls below 0.02 mg/L and ORP returns to within ±20 mV of baseline. This sequence removes attached biomass in piping elbows, tank headspace, and dead legs without leaving disinfection byproducts that would contaminate subsequent ultrapure water. The microbial count in the loop after re-establishment is verified at <1 CFU/100 mL by membrane filtration, and the final rinse water meets SEMI F63-0521 resistivity ≥18.2 MΩ·cm at 25 °C, total organic carbon <5 μg/L, and dissolved silica <0.5 μg/L. Analytical confirmation of sanitizer residual is performed by DPD colorimetry per EPA 334.0 and by amperometric electrode calibrated against ASTM D2022-19 iodometric titration. For heat-sensitive reverse osmosis trains, the operating boundary is the manufacturer-documented free chlorine tolerance of the specific membrane grade; continuous exposure above 1.0 mg/L FAC is not applied to polyamide composite membranes because chlorine-induced oxidation of the barrier layer increases salt passage.
| Downstream segment | FAC concentration | pH window | Contact time | Temperature | Critical endpoint |
|---|---|---|---|---|---|
| Semiconductor post-ash pre-clean | 10–30 mg/L | 5.2–5.8 | 30–90 s | 22–25 °C | Cl ≤1×1010 atoms/cm² |
| Flat-panel display substrate preparation | 5–15 mg/L | 4.8–6.2 | 20–40 s | 35–45 °C | C ≤0.3 μg/cm²; Cl ≤0.5 ng/cm² |
| Ultrapure water loop and RO sanitation | 0.5–1.0 mg/L | 5.5–6.0 | 60–120 min | 22–30 °C | Residual Cl <0.02 mg/L; <1 CFU/100 mL |
| Aseptic isolator decontamination | 50–150 mg/L | 5.0–6.5 | 10–20 min | 18–25 °C | Extraction Cl <0.05 mg/L |
| Reticle pod interior cleaning | 20–50 mg/L | 5.0–6.0 | 5–10 min | 20–25 °C | Metals <0.1 ng/cm² |
| Photovoltaic cover glass edge cleaning | 5–15 mg/L | 5.5–6.5 | 30–60 s | 40–50 °C | Cl <2 mg/m² |
A chloride-extraction-limited bio-decontamination sequence in aseptic isolators for pharmaceutical transfer of vials, stoppers, and syringes applies Electronic/EL grade HOCl at 50–150 mg/L FAC, prepared by 1:20 to 1:6.7 dilution of 1,000 mg/L stock, at pH 5.0–6.5 and 18–25 °C. Low-pressure rotary nozzles deliver 1.0–2.0 L/min to achieve a visibly wet surface with contact time of 10–20 min. The product is selected because the low trace-metal burden reduces residue on passivated 316L stainless steel and chlorobutyl elastomer glove materials compared with technical sodium hypochlorite grades that can contain 20–50 mg/L sodium and 1–5 mg/L transition metals. A critical operational boundary is chloride extraction after decontamination; treated surfaces are rinsed with Water for Injection at 60–70 °C until condensate or swab extract shows chloride below 0.05 mg/L by ion chromatography per ISO 10304-1:2007. If extraction is truncated, residual chloride can initiate pitting on stainless steel welds and accelerate degradation of nitrile transfer gauntlets at repeated exposure. Disinfectant efficacy is verified against facility environmental isolates by surface challenge per USP <1072> and the relevant pharmacopoeial disinfectant qualification; routine monitoring uses contact plates with limits aligned to ISO 14644-1 for the occupied cleanroom state. A 500 L working solution at 100 mg/L from 1,000 mg/L stock requires 50 L of EL grade concentrate and is used within 4 h because FAC half-life in cleanroom lighting can fall below 2 h at pH above 6.5. Finished materials move into Grade A filling after aeration and surface dryness verification on a stainless-steel surrogate coupon.
Replacement of isopropyl alcohol in photomask reticle pod interiors uses a 20–50 mg/L FAC solution at pH 5.0–6.0, prepared by 1:50 to 1:20 dilution from 1,000 mg/L Electronic/EL grade stock, and applied at 20–25 °C to polycarbonate or polypropylene pod interior surfaces by low-pressure spray and cleanroom wiper. Contact time is 5–10 min, followed by hot UPW rinse at 40–50 °C and drying under high-efficiency particulate air filtered to 0.003–0.1 μm. Removing isopropyl alcohol eliminates alkane and ester residues that can outgas and deposit on 193 nm or 13.5 nm mask surfaces under vacuum or high photon flux. Extractables after cleaning are measured by ICP-MS after dynamic water extraction; sodium, calcium, magnesium, and iron should remain below 0.1 ng/cm², and non-volatile residue below 0.1 μg/cm². Compliance is checked against SEMI C1 for analytical methodology and ISO 10304-1:2007 for chloride breakthrough after rinsing. The process is limited to non-optical surfaces; direct application to pelliculated reticle surfaces is not used because hypochlorous acid can degrade fluoropolymer pellicle films and because particle generation from pod gasket materials increases after repeated exposure exceeding 30 cycles. Published data for this specific configuration is limited, so cycle life is requalified with the pod supplier. The finished dry pod is purged with clean dry air filtered to 0.003 μm and passed into the mask shop stocker.
Roll-to-roll and sheet-fed photovoltaic cover glass cleaning lines using HOCl before anti-reflective coating deposit a working solution at 5–15 mg/L FAC, prepared by 1:200 to 1:66 dilution from 1,000 mg/L Electronic/EL grade concentrate, at pH 5.5–6.5 and 40–50 °C. The chemical is sprayed in a horizontal brush conveyor, with contact time of 30–60 s, to oxidize adsorbed cutting oils, edge grinding debris, and atmospheric organic films without leaving the metal-cation residue that technical sodium hypochlorite would deposit in the coating interface. The process window is narrow in pH and concentration; at pH below 5.5, chloride retention on textured glass edges increases, and at FAC above 15 mg/L, the subsequent deionized water rinse must be prolonged beyond 60 s to meet the chloride threshold. The final glass is monitored by surface energy measurement, and anti-reflective coating adhesion is tested by cross-cut per ISO 2409:2013 after lamination at 150–200 °C. Residual chloride on the glass before coating is held below 2 mg/m² by ion-chromatographic extraction in 250 mL of deionized water per 1 m² glass. Published data for this specific configuration is limited, so line qualification includes a statistical process capability study across 50 glass sheets to confirm adhesion loss below 1% by area.
| Control task | Method or standard designation | Typical limit |
|---|---|---|
| Free available chlorine verification | ASTM D2022-19; EPA 334.0 | Application-specific FAC range |
| Trace metal extractables in liquid | SEMI C1; ICP-MS | Na, K, Ca, Fe ≤1 μg/L or ≤100 ng/L by segment |
| Chloride residue after rinse | ISO 10304-1:2007 | 0.05 mg/L to 0.5 ng/cm² by segment |
| Particle burden | SEMI C1; ISO 14644-1 | ≥0.05 μm or ≥0.2 μm per process specification |
| Microbial count after sanitation | Membrane filtration; ISO 14644-1 | <1 CFU/100 mL for UPW loops |
| Coating adhesion after cleaning | ISO 2409:2013 | Adhesion loss <1% by area |
Competitive Hypochlorous Acid Electronic/EL Grade prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8615365186327
Email: admin@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Hypochlorous acid Electronic/EL Grade is supplied as a high-purity aqueous formulation under product codes EL-HOCL-0500 and EL-HOCL-1000, corresponding to nominal free available chlorine concentrations of 500 mg/L and 1000 mg/L respectively. The product is specified at pH 5.5–6.5 and an oxidation-reduction potential of 850–950 mV versus Ag/AgCl at 25 °C. At this pH interval, the chlorine equilibrium places >95% of free available chlorine as undissociated HOCl, the neutral molecular form associated with high biocidal penetration and reduced anionic hypochlorite character. The product is generated from high-purity water and dilute hydrochloric acid in a membrane electrolysis module, not by dilution of commodity sodium hypochlorite. Consequently, sodium, potassium, calcium, iron, copper, and zinc content is controlled to <1 µg/L per element when analyzed by inductively coupled plasma mass spectrometry.
The electrochemical route oxidizes chloride at a dimensionally stable anode according to 2Cl⁻ → Cl₂ + 2e⁻, followed by chlorine hydrolysis to form hypochlorous acid according to Cl₂ + H₂O ⇌ HOCl + H⁺ + Cl⁻. A cation-exchange membrane separates the anolyte and catholyte to limit cation and chloride drag-over into the product water. This route yields a lower residue matrix than direct chlorine gas injection or dilution of sodium hypochlorite. The product is intended for cleanroom surface disinfection, high-purity water system sanitization, and controlled-environment contamination control. It is not positioned as a direct wafer-cleaning chemistry; published data for device-level wafer-cleaning integration is limited, and semiconductor process qualification is required before direct contact with product wafers is assessed.
| Parameter | Analytical Method | Typical Specification |
|---|---|---|
| Free available chlorine | ISO 7393-2:2017 | 500 ± 50 mg/L or 1000 ± 100 mg/L |
| pH | ASTM D1293-18 | 5.5–6.5 |
| Oxidation-reduction potential | ASTM D1498-14 | 850–950 mV vs Ag/AgCl |
| Trace metals: Na, K, Fe, Cu, Ca, Zn | ISO 17294-2:2016 | <1 µg/L per element |
| Residue after evaporation | Gravimetric | <5 mg/L |
| Particle count at ≥0.1 µm | USP <788> | <50 particles/mL |
Diluted sodium hypochlorite is an alkaline equilibrium mixture with a sodium cation load roughly equimolar to available chlorine. For a 500 mg/L free available chlorine bleach solution, the sodium concentration approximates 162 mg/L; hypochlorite ion constitutes more than 50% of the chlorine species above pH 8.0. Electronic/EL Grade hypochlorous acid contains sodium below 0.1 mg/L and holds pH below 6.5, so the biocidal HOCl form remains dominant. Electrolyzed oxidizing water generated from sodium chloride brine carries sodium and chloride residuals above 50 mg/L unless post-treated. The hydrochloric acid–based membrane process used for the Electronic/EL Grade reduces cationic metal and chloride drag-over and produces a lower residue matrix. Compared with quaternary ammonium products, the product leaves no persistent cationic film. Compared with hydrogen peroxide–peracetic acid blends, it does not leave acetic acid or peroxide residues after aeration.
These differences are relevant in controlled environments because non-volatile residues can alter surface contact resistance, contaminate ion chromatography blanks, or contribute to particle deposition. The product is therefore specified with a residue after evaporation below 5 mg/L and a particle count at ≥0.1 µm of <50 particles/mL by USP <788>. Free available chlorine is determined by DPD colorimetry under ISO 7393-2:2017. Trace metals are determined by ISO 17294-2:2016. Chlorate content is monitored by ion chromatography with a limit based on end-user residue tolerance; no quaternary ammonium cation, alcohol, aldehyde, or phenol is added to the formulation.
Cleanroom biocontamination control programs in ISO 14644-1:2015 class 5 and class 7 environments frequently apply the 500 mg/L product through pneumatic or ultrasonic fogging nozzles producing a mass median diameter of 5–15 µm. Wet contact times of 5–10 min on electropolished stainless steel, vinyl, epoxy flooring, and glass are typical for bactericidal and fungicidal outcomes, but site-specific validation against the target microbiota should be performed according to EN 13697:2015+A1:2019. Equipment should be operated at room temperature 20–25 °C and relative humidity below 65% to avoid condensation that can carry airborne residues into ULPA filter housings. Because the product contains no surfactant, surface tension remains near 72 mN/m, similar to water, which can limit wetting on hydrophobic polymer surfaces and may require longer contact times. Post-fog surfaces may require a high-purity water wipe if visible liquid remains after the aeration period.
When total fogging volume exceeds 10 mL/m³, the cleanroom air handling system is typically placed in recirculation bypass, and dampers are set to exhaust for 20–30 min after the dwell to reduce airborne chlorine species. Airborne total chlorine should be verified below 0.5 ppm at return-air grilles before operators re-enter without respirators; a direct-reading electrochemical sensor with a minimum resolution of 0.01 ppm is preferred. Process equipment and exposed metal panels should be inspected for liquid pooling because hypochlorous acid solutions can wick into crevices and produce localized corrosion or residue crystallization. For fogging cycles exceeding 10 mL/m³, repeated exposure to polycarbonate covers and acrylic windows is not recommended without manufacturer compatibility data. Following the aeration phase, an optional high-purity water rinse at 18.2 MΩ·cm resistivity removes chloride residues from polished surfaces; this rinse is especially relevant for surfaces that will later contact analytical sensors or microelectronic assemblies.
In ultrapure water distribution loops, the product is used at 50–100 mg/L free available chlorine during sanitization holds, with loop recirculation maintained for 60–120 min before draining. Polyvinylidene fluoride and 316L electropolished stainless steel are commonly used in the distribution system; elastomeric seals should be checked against chlorinated oxidizer compatibility. Because the product introduces chloride ion, the loop must be rinsed with ultrapure water until resistivity returns to ≥18.2 MΩ·cm at 25 °C and total organic carbon falls below 10 µg/L by on-line oxidation. This rinse endpoint is more stringent than is required for municipal water systems and distinguishes electronic/EL grade use from general facility sanitization. Published data for specific wafer-cleaning immersion processes using this product is limited; process owners should conduct oxide-film and metal-loss studies before integrating it into wet bench operations.
At 500–1000 mg/L free available chlorine, the product is not compatible with aluminum 1100, copper C11000, brass, mild steel, or zinc-galvanized surfaces. Prolonged contact with these substrates can generate localized corrosion, hydrogen evolution, and metal ion release. Electropolished 316L stainless steel and 304L stainless steel are generally resistant at ambient temperature for limited exposure periods up to 24 h, but crevices, weld seams, and stressed zones require review because chloride-assisted stress corrosion cracking risk increases above 60 °C. Coupon weight-loss testing according to ASTM G31-21 is recommended when a new equipment surface or elastomer is introduced. The product should not be mixed with ammonia, amines, or alkaline cleaners because chloramine formation is rapid and may produce volatile irritants. Mixing with reducing agents, strong acids, or hydrogen peroxide releases heat and chlorine gas.
For polypropylene, high-density polyethylene, polytetrafluoroethylene, and polyvinylidene fluoride, the product shows acceptable service for short-term contact; seals made of natural rubber, neoprene, or polyamide should be avoided. Following application, rinse water should be analyzed for chloride and free chlorine to verify complete removal. In facilities that routinely monitor airborne molecular contamination, chloride levels on surfaces can be quantified by ion chromatography after extraction; this is a standard method in semiconductor fabs for corrosion risk assessment. The product is distributed by peristaltic pump or inert pressure vessel; high-shear dispersion is not required, and no additional wetting agent is permitted in the electronic/EL grade specification.
Hypochlorous acid decomposition is accelerated by ultraviolet light, elevated temperature, and catalytic transition metals. The product is stored in opaque, vented high-density polyethylene containers to limit oxygen gas accumulation and to maintain the product within the 15–25 °C range. At 40 °C, accelerated aging studies conducted according to ASTM F1980-21 show that free available chlorine half-life can fall below 30 days depending on packaging headspace and pH drift. Cold-chain storage is not required, but warehouse temperature should remain below 30 °C and the product should not be stored in sunlight or near ozone generators. Chlorate formation is monitored by ion chromatography to ensure that the product remains within the specified chlorate limit during its lot-release shelf life. Each opened container is assigned a 7-day use period to minimize contamination and free available chlorine drift. The product is not classified as flammable, but headspace oxygen accumulation in unvented containers requires use of closures that relieve pressure without permitting carbon dioxide ingress.