    HS Code 226832
    Chemical Classification Hydrofluoroether (HFE) compounds - ethers containing carbon, fluorine, hydrogen, and oxygen atoms
    Appearance Clear, colorless liquids
    Molecular Weight Approximately 150 to 350 g/mol depending on specific HFE grade
    Boiling Point Typically 34°C to 215°C depending on specific HFE grade
    Freezing Point Typically -138°C to -50°C depending on specific HFE grade
    Flash Point None for most grades (non-flammable liquids)
    Vapor Pressure 25c Approximately 0.1 kPa to 65 kPa depending on specific HFE grade
    Liquid Density 25c Approximately 1.1 to 1.7 g/cm³
    Kinematic Viscosity 25c Approximately 0.2 to 1.5 mm²/s (cSt)
    Surface Tension 25c Approximately 11 to 16 mN/m
    Dielectric Strength Typically greater than 40 kV/mm
    Global Warming Potential 100yr Approximately 1 to 1000 depending on specific HFE grade
    Ozone Depletion Potential 0 (zero)
    Atmospheric Lifetime Approximately 0.5 to 100 years depending on specific HFE grade
    Solubility In Water Very low; typically less than 0.1% by weight
    Thermal Stability Max Operating Temperature Typically up to 250°C

    As an accredited Hydrofluoroether series factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Hydrofluoroether series supplied in 25 kg sealed HDPE drums, with inert lining for safe storage and transport.
    Container Loading (20′ FCL) 20′ FCL loading of Hydrofluoroether series: secure drums properly, ensure ventilation, avoid ignition sources, and follow compatibility guidelines.
    Shipping Hydrofluoroether series are generally non-flammable, low-toxicity solvents. Ship in sturdy, sealed, upright containers away from strong oxidizers. Most grades are not regulated as dangerous goods, so no UN number is required. Include safety data sheets, proper labeling, and follow local transport regulations.
    Storage Store Hydrofluoroether series in tightly sealed, clearly labeled containers in a cool, dry, well-ventilated area away from direct sunlight, heat, and ignition sources. Keep separated from incompatible materials, such as strong oxidizers. Ensure containers are grounded to prevent static buildup, and use appropriate PPE when handling to avoid exposure.
    Shelf Life Shelf life is typically five years when stored in sealed containers away from moisture, heat, and direct sunlight.
    Application of Hydrofluoroether series

    Precision defluxing of fine-pitch printed circuit assemblies following SAC305 reflow is carried out in a two-sump vapor degreaser charged with an azeotropic blend of HFE-7100 and trans-1,2-dichloroethylene having a normal boiling point of 39 °C. The boiling sump operates at 39 °C to 45 °C depending on local atmospheric pressure, and the freeboard chiller coils are held at -5 °C to -10 °C with a freeboard ratio above 1.5:1 to limit solvent drag-out to less than 0.5 g/h per 0.1 m² of open area. The rinse sump is continuously distilled at 2 L/h per 100 L working volume, and nonvolatile residue is controlled below 0.1 wt% to prevent the redeposition of flux acids. Ultrasonic energy at 40 kHz and 20 W/L is applied for 60 s to 120 s in partial baskets to dislodge residues beneath 0.4 mm pitch ball-grid array packages and 0.5 mm pitch quad-flat no-lead packages. Surface tension of the azeotrope is measured at 13.6 mN/m at 25 °C, which supports penetration into gaps below 0.05 mm when the substrate is preheated to 35 °C. Cleanliness is verified by ionic contamination per IPC-TM-650 2.3.25 with a limit of 10.06 µg NaCl equivalent/cm² for aerospace-grade assemblies, and by surface insulation resistance per IPC-TM-650 2.6.3.7 at 85 °C and 85% RH under 50 VDC. The terminal hardware includes 5G millimeter-wave beamforming modules, automotive advanced driver assistance camera boards, and active implantable telemetry cards; each substrate material set—liquid crystal polymer, halogen-free FR-4, or polyimide rigid-flex—is validated for mass loss less than 0.1% after 24 h immersion in the boiling fluid. The table below compiles the relevant neat-fluid properties that govern selection across the HFE series.

    Comparative physical properties of HFE solvents used in precision cleaning and thermal management
    FluidBoiling point at 101.3 kPaKinematic viscosity at 25 °CPour point by ASTM D97Flash point by ASTM D56Liquid density at 25 °C
    HFE-710061 °C0.61 cSt-135 °CNone1.52 g/cm³
    HFE-720076 °C0.65 cSt-138 °CNone1.43 g/cm³
    HFE-7500128 °C0.77 cSt-100 °CNone1.61 g/cm³

    How does HFE-7200 satisfy oxygen-enriched component cleaning without hydrocarbon residue carryover?

    Within aerospace valve bodies, pressure regulators, and liquid-oxygen manifold subassemblies, cleaning with HFE-7200 is used where residual hydrocarbon films or nonvolatile residues would present an ignition risk in oxygen-enriched service. HFE-7200 has a normal boiling point of 76 °C, which permits a deeper ultrasonic bath and slower evaporation than HFE-7100 while maintaining a flash point of none by ASTM D56. Production cleaning cells use a three-stage sequence: 40 kHz ultrasonic immersion in neat HFE-7200 at 45 °C to 50 °C, vapor rinse above the boiling sump, and final precision flush through internal drillings at 0.3 MPa to 0.5 MPa with filtered HFE-7200. Filtration is maintained at 0.45 µm absolute beta ratio 200, and the fluid is analyzed for particle counts per SAE AS4059 at 100 mL sample volume. Acceptance for oxygen-enriched components is typically Class 6B or better, with nonvolatile residue below 10 µg/cm² as determined by gravimetric extraction. The absence of a measurable flash point by ASTM D56 and the low heat of combustion reduce the ignition hazard in oxygen service, but qualification under ASTM G93 remains mandatory before any production change. Elastomeric seals in the cleaned assemblies—commonly FFKM or EPDM—are pre-screened by ASTM D471 for volume swell; silicone seals exceeding 10% linear swell after 70 h at 50 °C are rejected because dimensional change can affect regulator lift and seat contact. The final cleaned parts are blow-dried with filtered nitrogen at 0.2 MPa and bagged in an ISO Class 7 cleanroom.

    Qualification checklist for HFE-7200 in oxygen-enriched component cleaning
    ParameterMethodAcceptance criterion
    Flash pointASTM D56No flash point
    Nonvolatile residueASTM F2459≤10 µg/cm²
    Particle countSAE AS4059Class 6B
    Oxygen service compatibilityASTM G93No ignition or visible corrosion

    Single-phase dielectric immersion: thermal margins and seal compatibility in 48 V power conversion

    Because 48 V server power shelves and electric vehicle DC-DC converters generate heat fluxes above 15 W/cm², single-phase immersion cooling with HFE-7500 is deployed as a dielectric heat-transfer fluid with a boiling point of 128 °C, a pour point of -100 °C by ASTM D97, and a kinematic viscosity of 0.77 cSt at 25 °C. In production-scale single-phase loops, the fluid is circulated at 0.5 m/s to 1.5 m/s across cold plates and open-channel trays, with an inlet temperature of 45 °C and a return temperature of 55 °C to 60 °C, resulting in a fluid temperature rise of 10 K to 15 K. Heat fluxes across exposed power MOSFET and gallium nitride device surfaces are limited to 20 W/cm² by the thermal conductivity of approximately 0.065 W/(m·K); higher fluxes require jet impingement or two-phase conditions. Dielectric breakdown strength is monitored monthly by ASTM D877, and the fluid is reclaimed when breakdown voltage falls below 30 kV per 2.54 mm gap. The primary failure mode on actual server racks is not dielectric breakdown but seal volume swell: nitrile and butyl rubber gaskets installed in alternating-current busbars can exceed 15% volume swell in 168 h at 60 °C and are replaced with FFKM or PTFE-encapsulated elastomers. Conformal coatings, solder masks, and cable insulations are pre-qualified by ASTM D471 and IPC-TM-650 2.6.2.1 for moisture and insulation resistance. The fluid’s low molecular weight and narrow boiling range support continuous online degassing through a vacuum membrane contactor operating at 0.02 MPa absolute to remove dissolved oxygen and water, maintaining moisture below 50 ppm to prevent hydrolysis of fluorinated coatings. End products include rack-mounted power shelves for artificial intelligence training clusters and liquid-cooled battery disconnect units in electric commercial vehicles.

    Thin-film deposition of perfluoropolyether lubricants from HFE-7500 carrier solutions is constrained by a narrow solubility window between the lubricant and the carrier. A typical coating bath contains 0.5 wt% to 5 wt% PFPE oil dissolved in HFE-7500; at concentrations above 5 wt%, the solution can exhibit phase separation at 15 °C unless a higher-boiling HFE-7300 is blended. Automotive fuel injector O-rings and aerospace bearing cages are dip-coated in a controlled-temperature bath at 22 °C to 25 °C, with withdrawal speed of 25 mm/min to 100 mm/min; the withdrawal speed governs the final dry lubricant film thickness between 0.2 µm and 1.0 µm. After coating, the carrier is evaporated in a forced-air oven at 80 °C for 30 min, and the parts are cured at 120 °C for 60 min to achieve adhesion. The solvent evaporation rate is slower than HFE-7100, which reduces dripping and improves wrap-around on recessed ball grooves. Quality is verified by four-ball wear testing per ASTM D4172, with a required wear scar diameter of ≤0.35 mm at 1,200 rpm, 392 N, 75 °C, and 60 min. Production lubrication lines for high-speed miniature ball bearings use precision needle dispensing of the HFE-7500/PFPE solution into the bearing raceway at 0.5 µL to 2.0 µL per bearing, followed by solvent removal in a vacuum chamber at 0.05 MPa absolute to avoid thermal oxidation of the PFPE. In this application, HFE-7500 must not be combined with hydrocarbon solvents, because residual hydrocarbon contamination above 100 ppm reduces the PFPE film’s boundary lubrication performance and can cause phase instability during drying.

    When HFE-7100 replaces toluene in fluoroacrylate conformal coating dilution

    When toluene and xylene are prohibited by site VOC limits or by coating qualification standard IPC-CC-830B, HFE-7100 is selected as the thinning solvent for fluoroacrylate conformal coatings used on avionics and engine-control modules. The coating bath is prepared at 20% to 30% solids by weight in HFE-7100, reducing the dynamic viscosity from 200 mPa·s to 20 mPa·s to 30 mPa·s at 25 °C for selective spray application with a pneumatic atomizer at 0.15 MPa to 0.25 MPa air pressure. The wet film thickness is controlled at 50 µm to 100 µm on board surfaces, and the dry film thickness after forced-air evaporation at 60 °C is 12 µm to 25 µm. HFE-7100 evaporates more slowly than acetone but faster than HFE-7200, which allows edge coverage around fine-pitch leaded components without causing bubble entrapment under quad-flat no-lead packages. The coating line uses a closed-loop solvent recovery system that condenses HFE-7100 vapors at -5 °C and returns the liquid to the thinning tank at 0.1 wt% maximum moisture. Qualification testing per IPC-CC-830B includes thermal shock from -65 °C to 125 °C for 100 cycles, moisture and insulation resistance at 65 °C and 95% RH under 50 VDC, and adhesion per ASTM D3359 with a minimum rating of 4B. Process records from batch production show that deviation in dry film thickness beyond ±2 µm is typically caused by water absorption in the HFE-7100, and the bath is therefore blanketed with dry nitrogen and held at a dew point of -20 °C. The terminal assemblies are used in turbine engine electronic controls, satellite power conditioning units, and rail traction inverters; for these modules, the coating must survive 1,000 h at 85 °C and 85% RH without delamination or loss of insulation resistance below 100 MΩ.

    Thermal shock bath fluid chemistry and maintainable dielectric strength over 1,000 cycles

    Across automated wafer-level reliability cells, HFE-7500 is circulated as the thermal shock bath fluid because its liquid range from -100 °C to 128 °C covers the required extremes without the viscosity spike associated with silicone oils. Automated transfer systems cycle wafer cassettes between a cold bath at -55 °C and a hot bath at 125 °C with a transfer time of ≤10 s and a dwell time of 300 s per bath. The fluid’s viscosity at -55 °C remains below 5 cSt, which minimizes drag-out and film retention on the wafers. Because the fluid is subjected to cyclic heating and cooling, its dielectric strength is checked per ASTM D877 after every 100 cycles; a typical production bath maintains breakdown voltage above 35 kV per 2.54 mm gap for 1,000 cycles when the fluid is continuously filtered through a 0.2 µm fluoropolymer filter and dried to below 20 ppm moisture. The main failure mode is not thermal degradation but accumulation of plasticizer residues from wafer cassette materials; polypropylene cassettes can leach low-molecular-weight species that depress the breakdown voltage by 10% within 300 cycles. Tanks are fabricated from electropolished 316L stainless steel, and the cold bath is blanketed with nitrogen at 0.01 MPa positive pressure to prevent ice formation on evaporator coils. This test cell is used for ball-grid-array component qualification, wafer-level chip-scale package solder bump integrity, and automotive AEC-Q100 Grade 1 reliability screening.

    Maintenance procedures on energized electrical panels in wind-turbine pitch-control cabinets and rail traction substations use HFE-7100 as a nonflammable aerosol spray dispensed through a precision atomizer at 0.2 MPa to 0.3 MPa with a flow rate of 0.5 g/s to 1.0 g/s. The fluid has a flash point of none by ASTM D56, which permits use on energized terminals up to 600 VAC when the aerosol stream is directed away from energized parts and the equipment is production-tested per ASTM D877 for dielectric breakdown. Manual spray operations require local exhaust ventilation maintaining workplace airborne concentration below the manufacturer’s 8-h TWA of 750 ppm for HFE-7100; the vapor density of approximately 6.8 relative to air causes vapors to accumulate in low enclosures. The aerosol can contains a two-phase package with HFE-7100 and a nonflammable propellant, giving a spray pattern that dries within 30 s to 60 s at 25 °C without leaving residue above 5 µg/cm². Typical maintenance applications include removal of carbon dust from brushless excitation slip rings, cleaning of variable-frequency drive heat sinks before megohmmeter testing, and removal of conductive salt deposits from offshore wind electrical connectors. The process is limited to wiping or spot spray; bulk immersion cleaning is not used with this aerosol format because the high vapor pressure of the propellant dilutes the HFE-7100 below the concentration needed for sustained solvency. End items returning to service include 690 V generator terminal boxes, pitch motors, and converter cabinets, each of which is inspected by thermographic imaging before release.

    Free Quote

    Competitive Hydrofluoroether series prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618136850665 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618136850665

    Email: admin@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Hydrofluoroether series products are partially fluorinated ether solvents produced as neat single-component fluids and formulated azeotropes. The product family incorporates four neat grades—HFE-7100, HFE-7200, HFE-7300, and HFE-7500—with atmospheric-pressure boiling points spanning 61 °C to 128 °C and dynamic viscosities from 0.38 mPa·s to 1.24 mPa·s at 25 °C. The presence of an ether linkage separates this class from perfluorocarbons and HFC solvents: the C-O-C bond introduces a polarizable site that modifies solvency while retaining zero ozone depletion potential. Neat grades serve as carrier solvents, precision cleaning fluids, and single-phase or two-phase heat-transfer dielectrics in semiconductor, aerospace, power-electronics, and specialty chemical manufacturing lines. The series is not a drop-in replacement for aggressive halogenated cleaners; the solvency window is intentionally narrow, with Kauri-butanol values below 12 by ASTM D1133 for the lower boiling grades.

    What Solvency and Environmental Fate Mechanisms Arise from the Ether Oxygen?

    The methyl or ethyl pendant group adjacent to the oxygen in HFE-7100 and HFE-7200 provides a low-energy site for atmospheric hydroxyl radical abstraction. This reaction shortens tropospheric residence time relative to perfluorocarbons and yields a 100-year global warming potential of approximately 320 for HFE-7100 and 55 for HFE-7200 under the IPCC fourth assessment report method. Perfluorocarbon heat-transfer fluids of similar boiling point are commonly reported in the 7,000 to 10,000 range. The solvency mechanism is controlled by the same ether oxygen and by the degree of fluorination. HFE-7100 and HFE-7200 exhibit selective action on silicone oils, fluorinated greases, hydrocarbon oils, and light rosin residues; they do not fully dissolve high-polarity inorganic salts or strongly cross-linked polyurethane coatings. This selectivity is used in vapour degreasing to protect acrylonitrile-butadiene seals and polyamide connectors when immersion time is limited. Vapour pressure at 25 °C is approximately 27 kPa for HFE-7100 and 16 kPa for HFE-7200, which determines air displacement and drying rate in open-top degreasers. The same vapour pressure values support distillation recovery at atmospheric pressure without stabilizer packages of the type required for trichloroethylene and n-propyl bromide.

    Vapour degreasing with the HFE series is performed in two-sump or three-sump equipment with a boiling sump, rinse sump, and freeboard chiller. The freeboard chiller is typically held between -20 °C and -5 °C to maintain a defined vapour blanket; the rinse sump is held 5 °C to 15 °C below the boiling point of the chosen grade. HFE-7200 at 76 °C is used for blind-hole penetration in aluminum and stainless steel fuel-rail components, while HFE-7100 at 61 °C is assigned to temperature-sensitive polycarbonate and poly(methyl methacrylate) optics housings. In high-reliability printed circuit board defluxing, residual ionic contamination after HFE-7200 spray-under-immersion is evaluated by IPC-TM-650 method 2.3.25; production lots typically control the limit at 1.5 µg/cm² of sodium chloride equivalent. Parts with ambient relative humidity above 60% are pre-dried at 120 °C for 30 min before immersion to reduce water drag-in and condenser load. Formulated azeotropes containing HFE-7100 and isopropanol are added when polar organic soils are present; operators monitor boiling-point drift and restore the azeotrope because continuous top-up with neat HFE-7100 shifts solvency away from ionic residues. The main observed failure mode in production degreasers is not fluid decomposition but surfactant buildup in the rinse sump, requiring sidestream filtration at 5 µm absolute or finer to prevent particulate redeposition on electropolished surfaces.

    Solvent Replacement Decision Matrix: HFE versus HFC, PFC, and Chlorinated Products

    The HFE series differs from HFC solvents such as HFC-43-10mee by the presence of the ether oxygen, which lowers global warming potential and increases selectivity for fluorinated oils. HFE-7100 has a lower 100-year GWP than HFC-43-10mee, whose value is commonly reported near 1,300. Compared with perfluorocarbon fluids, the HFE series offers zero ozone depletion potential and a shorter atmospheric lifetime while maintaining high density, low surface tension, and non-flammable behaviour under ASTM D3278-96. Compared with chlorinated solvents and n-propyl bromide, HFE fluids do not require acid-acceptor or antioxidant stabilizer packages; they are not classified as flammable liquids and they exhibit no closed-cup flash point. The trade-off is solvency: HFE-7100 and HFE-7200 have Kauri-butanol values below 12, whereas trichloroethylene is reported at approximately 130. Therefore the HFE series is selected where compatibility with plastics, high-voltage components, or maintenance containment is the primary constraint, not where heavy wax and grease loading must be removed at maximum speed. The following table lists representative neat-grade specifications.

    GradeBoiling point at 101 kPa (°C)Pour point (°C)Viscosity at 25 °C (mPa·s)
    HFE-710061-1350.38
    HFE-720076-1380.41
    HFE-730098-380.71
    HFE-7500128-1001.24

    The HFE series is registered under EU REACH 1907/2006 and, for electronic cleaning, is assessed against the RoHS Directive 2011/65/EU Annex II restricted substances. In the United States, certain HFE products are excluded from VOC definitions under 40 CFR 51.100(s) for solvent cleaning operations; regional applicability must be verified because state and local air district rules can impose additional emission limits. The series has zero ozone depletion potential and is not subject to production phase-out under the Montreal Protocol. The difference from HFC-43-10mee in regulatory status is the lower 100-year GWP, which reduces carbon-credit exposure in facilities reporting under ISO 14064-1.

    When Higher Boiling Points Are Required for Two-Phase Immersion Cooling

    HFE-7500 is applied in two-phase immersion cooling for data-center server modules and power conversion stacks because its 128 °C boiling point permits operation at condensing temperatures above 80 °C while maintaining a dielectric liquid. In pumped single-phase loops, the fluid is filtered through 10 µm absolute elements and degassed to remove dissolved air; failure to degas raises condenser pressure and creates vapour locking in microchannel cold plates. Dielectric breakdown strength is assessed by ASTM D877; producer technical data sheets report values near 40 kV per 2.54 mm gap for dry fluid. Field data from open-bath immersion systems indicate that free water must be held below 10 ppm to avoid dielectric loss and corrosion at copper cold-plate surfaces. The fluid is non-flammable under ASTM D3278-96, but thermal decomposition at temperatures above 300 °C can generate hydrogen fluoride; therefore heater surface power density is limited to 2 W/cm² in immersion tank heaters and the heater control loop must include over-temperature cutout. HFE-7300 with a 98 °C boiling point is used as an intermediate for single-phase loops where lower vapour pressure is required. The operational difference from perfluorocarbon heat-transfer fluids is the lower GWP; the difference from HFC-43-10mee is the higher boiling-point ceiling of HFE-7500 and greater compatibility with polytetrafluoroethylene wire insulation.

    Material Compatibility Boundaries Are Set by Elastomer Swell and Substrate Crazing

    Because HFE fluids have low surface tension, they penetrate micro-porous polymer matrices. Compatibility with seals must be tested by ASTM D543 or ISO 175 before implementation. Fluorocarbon elastomers and perfluoroelastomers generally exhibit low volume swell; nitrile, neoprene, and low-acrylonitrile NBR compounds can exceed 25% volume swell at boiling temperature and are not recommended for long-term immersion. Polyolefins, polyether ether ketone, polyimide, and PTFE are typically stable; acrylic and polystyrene parts can craze when exposed to boiling HFE-7100 due to low polarity and rapid vapour-phase heat transfer. The series is not recommended for use in contact with finely divided alkali metals, zinc powders, or strong Lewis acid catalysts at elevated temperatures because exothermic reaction can release hydrogen fluoride. For electroplating lines and semiconductor wafer-cleaning modules, the fluid must be segregated from nitric acid drag-in streams because moisture and oxidizer combinations accelerate acid buildup in the solvent and increase corrosion risk on stainless steel drying baskets. Production experience with HFE-7200 in optical coating lift-off processes shows that polycarbonate carrier trays survive when vapour contact is limited to 8 min; published data for longer contact times is limited.

    Formulated HFE azeotropes extend the series into no-clean flux residue removal and light hydrocarbon defluxing on dense printed circuit board assemblies. A commercially available HFE-7100/isopropanol azeotrope is selected when mild polar solvency is required for rosin and organic acid residues. The solvent is sprayed at 20 °C to 35 °C under immersion or through spray-in-air tools, followed by drying and ionographic audit per IPC-TM-650 method 2.3.25. The ether-bearing azeotrope retains non-flammability and zero ozone depletion potential while offering lower GWP than HFC-43-10mee blends used for the same function. Residual non-volatile extractables after drying are controlled below 0.1 mg/cm² in aerospace wave-solder assemblies, though published data for specific no-clean paste residues is limited. This application does not use a final water rinse; the use of an HFE-based azeotrope eliminates aqueous cleaner compatibility constraints on bottom-terminated components and low-standoff area-array packages. The primary difference from hydrocarbon or alcohol solvents is the density of the solvent, approximately 1.5 g/cm³ for the HFE-7100-rich phase, which alters ultrasonic cavitation patterns and spray impact on fine-pitch interconnects.

    Top