    HS Code 724188
    Maximum Continuous Service Temperature 220°C (short-term exposure up to 260°C)
    Dielectric Strength ≥ 18 kV/mm at 25°C for a 0.1 mm cured film
    Volume Resistivity ≥ 1×10^15 Ω·cm at 25°C
    Surface Resistivity ≥ 1×10^14 Ω/sq at 25°C
    Thermal Endurance > 2000 hours at 220°C
    Glass Transition Temperature ≥ 180°C
    Adhesion Performance ASTM D3359 Cross-Cut Class 5B on aluminum and glass substrates
    Flexibility Passes 1 mm diameter mandrel bend without cracking
    Cured Film Thickness Per Coat 5 to 20 μm depending on application method
    Cure Schedule 30 minutes at 150°C hot-air or infrared cure
    Solvent Resistance Resistant to MEK, isopropyl alcohol, and acetone after full curing

    As an accredited High Temperature Resistant Insulation Coating Material Electronic/EL Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Packaged in 1 kg sealed containers, this high-temperature resistant insulation coating material ensures purity for electronic/EL grade applications.
    Container Loading (20′ FCL) One 20′ FCL loaded with drums/pails of high-temperature-resistant electronic-grade insulation coating, securely palletized and protected for safe transit.
    Shipping This chemical ships in sealed, corrosion-resistant containers to prevent contamination and moisture ingress. Transport requires temperature-controlled, ventilated vehicles, avoiding direct sunlight and impact. Ensure proper hazard labeling and documentation. Keep upright, away from incompatible materials, and follow all regulations for safe handling and delivery.
    Storage Store in a cool, dry, well-ventilated area away from direct sunlight, heat sources, and open flames. Keep the container tightly sealed to prevent moisture absorption and contamination. Recommended storage temperature range is typically 5–35°C. Ensure adequate ventilation and keep incompatible materials separate. Shelf life is generally six months to one year from manufacture date if stored properly.
    Shelf Life Shelf life is 6 months from manufacture when stored sealed, cool, and dry.
    Application of High Temperature Resistant Insulation Coating Material Electronic/EL Grade

    Electronic/EL-grade high-temperature insulation coating materials are deployed where continuous operating temperatures exceed 150 °C and voltage stress interacts with thermal aging. The wet resin is supplied at 28–45% solids by weight, a viscosity of 150–800 mPa·s at 25 °C, and a cured dry-film thickness range of 15–250 μm. The following six downstream applications are limited to sectors where the coating is an actual dielectric barrier, not a decorative or mechanical topcoat. Characterization follows IEC 60243-1 for dielectric strength, IEC 62631-3-2 for volume resistivity, and IEC 60085 for thermal class assessment. The process descriptions are based on production-scale coating lines, VPI systems, selective spray cells, and curing towers; published data for some specific configurations is limited, and numerical ranges reflect typical manufacturing windows rather than single-source datasheets.

    Traction Motor Slot Encapsulation Demands a Dielectric Margin Above the Thermal Class Alone

    In traction motor slot encapsulation, the coating is deposited over slot liner paper and enameled copper windings before VPI. The addition ratio on production VPI lines is controlled by diluting the supplied resin to 32–38% solids by weight; dry-film thickness over the slot liner is 40–80 μm, with local build-up at slot exits held below 120 μm to avoid insertion interference. The production process begins with stator preheating at 60–80 °C for 2–4 h to drive off winding moisture, followed by vacuum pulling below 10 kPa absolute for 30–60 min and pressure assist at 0.4–0.6 MPa using dry air or nitrogen. Bath viscosity above 600 mPa·s at 25 °C produces a characteristic failure signature: bubble collapse at wire-to-wire interfaces, a drop in dielectric strength from 80–95 kV/mm to below 55 kV/mm under IEC 60243-1, and an increase in partial discharge events at the slot exit during IEC 60034-18-41 impulse testing. Compliance is anchored to IEC 60085 class H or N, UL 1446 insulation system recognition, and IEC 60034-18-41 for inverter-fed machines. Post-VPI cure follows a staged profile: 90 °C for 1 h, 130 °C for 2 h, and 175 °C for 2 h; rotation during draining reduces edge pooling at slot ends. Finished terminal product types are traction motors for battery electric vehicles, industrial servo motors, and high-speed spindle motors with continuous winding temperatures up to 180 °C and transient peaks to 200 °C.

    What Processing Limitations Emerge When High-Solids Liquid Coating Is Substituted for Powder Coatings on EV Busbars?

    When powder coating is replaced by high-solids liquid coating on EV busbar lines, robot-controlled airless spray systems must operate within a narrower sag-and-edge-coverage window. The addition ratio is maintained at 2.0–3.5% by weight of fumed silica relative to wet resin to control sag, with final dry-film thickness of 100–250 μm over copper busbars and 75–150 μm over laser-welded joints. The production process requires substrate heating to 40–60 °C before spraying; lower substrate temperatures increase surface condensation and cratering, while higher temperatures reduce flow time and produce orange-peel roughness above 12 μm Ra. Airless nozzle pressure is set to 8–12 MPa, gun speed to 300–600 mm/s, and overlap to 50–70%. The most severe processing limitation occurs at busbar edges, where cure shrinkage during 150–180 °C baking for 30–60 min can reduce edge dry-film thickness below 30 μm; this lowers dielectric withstand under IEC 60664-1 below the 2.5 kV reinforced-insulation requirement for an 800 V system. Compliance includes UL 94 V-0 at the finished assembly thickness, UL 746B relative thermal index at 130 °C or higher, and GB 38031-2020 thermal propagation testing. Finished terminal product types are lithium-ion battery modules, electric vehicle battery packs, and stationary energy storage busbar assemblies.

    The Viscosity Threshold Separating Acceptable Winding Impregnation From Partial Discharge Failure in Transformer Potting

    High-frequency ferrite and planar transformer manufacturing uses vacuum potting with the coating as an impregnation resin. The addition ratio is 100 parts by weight resin to 15–25 parts by weight reactive diluent and 0.5–1.0 parts by weight adhesion promoter; the mixture is degassed at 1–5 kPa for 10–20 min before dispensing. In the potting chamber, vacuum is pulled to 50–100 Pa to remove entrained air from windings with wire diameters down to 0.05 mm. Filling is performed under vacuum, followed by pressure assist at 0.3–0.5 MPa. The operating window is defined by viscosity: above 800 mPa·s at 25 °C, incomplete wetting of triple points at the core-winding interface lowers partial discharge inception voltage from 1.5 kV to below 0.8 kV under IEC 60270 at 50 Hz. Compliance for this segment is defined by UL 1446 system recognition, IEC 61558-1 for power transformers, and IEC 62368-1 for components in ICT equipment. The production process includes staged cure at 80 °C for 1 h, 120 °C for 2 h, and 160 °C for 3 h; post-cure C-scan inspection at 25 MHz rejects voids larger than 0.2 mm. Finished terminal product types include planar transformers for on-board chargers, high-frequency power transformers for server power supplies, and gate-drive transformers for railway traction inverters.

    The following matrix consolidates the principal compliance anchors referenced across the application segments. Test condition descriptions are abbreviated to the applicable equipment load protocol, not the full clause text.

    ApplicationStandard / ClauseTest ConditionRequired Performance
    Traction motor slot encapsulationIEC 60034-18-41Impulse voltage, inverter-fed dutyPDIV above 1.2 kV
    EV busbar insulationUL 94 V-0 / GB 38031-2020Vertical burn at final assembly thicknessNo sustained combustion after flame removal
    High-frequency transformer pottingIEC 6027050 Hz, 25 °C, void-free specimenPDIV above 1.5 kV
    PCB conformal coatingIPC-CC-830BThermal shock, 100 cyclesNo cracking, no loss of adhesion
    Heating element coatingIEC 60335-1 / IEC 60664-1Thermal cycling -40 °C to 260 °CNo flashing, maintained creepage
    Aerospace wire topcoatSAE AS22759 / FAR 25.869Scrape, abrasion, fire resistancePer applicable slash sheet limits

    For selective conformal coating of high-temperature automotive underhood and downhole drilling PCBs, the electronic/EL-grade material is diluted to 28–35% solids by weight, applied at 50–125 μm wet film through robotic needle-valve spray heads with needle diameters of 0.3–0.5 mm, cured at 150 °C for 30 min, and qualified to IPC-CC-830B, UL 746E, and MIL-I-46058C, producing engine control units, transmission control modules, and downhole measurement-while-drilling electronics.

    When a 0.2 mm Dip-Coated Layer Must Survive Thermal Cycling at 260°C

    Dip coating of cylindrical heating elements and power resistors uses the material at 35–40% solids by weight with 20–25 wt% inorganic filler loading. The substrate is preheated to 50–70 °C and immersed at a withdrawal speed of 0.1–0.4 m/min to deposit 0.2–0.5 mm dry film after cure. Withdrawal speed below 0.1 m/min is used only for cartridge heaters under 6 mm diameter because edge build-up exceeds 0.8 mm at the bottom termination. The dip line is controlled below 60% RH; higher humidity produces surface haze and local dielectric strength loss. The curing profile is 100 °C for 1 h, 180 °C for 2 h, and 220 °C for 1 h. Thermal cycling performance is assessed under IEC 60335-1, creepage and clearance under IEC 60664-1, and heater safety under UL 1030. Failure modes observed on production dip lines include pinholes at dust particles larger than 0.1 mm and end-face adhesion loss after 500 cycles from -40 °C to 260 °C. The operational boundary is 260 °C continuous with short-term excursions to 300 °C. Finished terminal product types include cartridge heaters, PTC ceramic heating elements, power resistors, and thick-film heating plates.

    Aerospace engine-zone wire and cable topcoat application is performed on tandem coating towers after primary insulation extrusion. The electronic/EL-grade material is applied as a 10–25 μm dry topcoat over fluoropolymer or polyimide primary insulation with 0.2–0.8% by weight of silane adhesion promoter in the dilute bath; tension is controlled between 1.0 N and 3.0 N, laser diameter gauge resolution is 0.1 μm, and amine-based adhesion promoter above 0.8% causes gel particles exceeding 15 μm that trigger automatic rejection. Compliance is governed by SAE AS22759 slash sheets, FAR 25.869 fire protection, and IEC 60068-2-6 vibration testing; finished terminal product types are engine-zone wiring, airframe harnesses, landing gear sensor cables, and high-temperature data bus cables.

    Free Quote

    Competitive High Temperature Resistant Insulation Coating Material Electronic/EL Grade prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615365186327

    Email: admin@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Product designation HTRIC-EL 550 is a single-component, solvent-borne insulation coating formulated from a polyimide-silicone hybrid binder, surface-treated fumed silica, and a high-flash cycloaliphatic ester solvent system. The material is supplied as a sprayable, screen-printable, and needle-dispensable liquid with a nominal solids content of 42 ± 2 % when tested in accordance with ASTM D2369, and a room-temperature Brookfield viscosity of 420–580 mPa·s at 25 °C under ASTM D2196. The grade is intended for electronic and electroluminescent (EL) dielectric layers that must survive continuous thermal excursions at 180–220 °C without loss of insulation resistance or film integrity. The product differs from general-purpose alkyd and polyurethane insulating varnishes by retaining a volume resistivity above 1.0 × 1014 Ω·cm per ASTM D257 after 1,000 h at 200 °C, and by exhibiting no visible cracking on a 1 mm mandrel bend per ASTM D522 at a dry film thickness of 25 µm. It is not a direct substitute for ceramic-filled epoxy thick-film dielectrics; published performance data for continuous operation above 220 °C or for single-pass film builds above 75 µm are limited, and qualification in the intended assembly configuration is required.

    Cure chemistry proceeds through solvent evaporation followed by thermal imidization and silanol condensation. The hybrid backbone contains a siloxane segment molecular weight between 1,500 g/mol and 2,500 g/mol, with an amide-to-imide conversion of 72–78 % after the standard cure schedule as measured by Fourier-transform infrared spectroscopy. Higher imide conversion increases the thermal endurance rating but reduces adhesion to indium tin oxide; higher siloxane content improves low-temperature flexure but depresses the 20,000 h thermal class below 180 °C. This formulation window is the primary reason the material is designated as an EL grade rather than a general-purpose high-temperature conformal coating.

    What Limits Continuous Operating Temperature in EL-Grade Dielectric Coatings?

    Thermal endurance is governed by oxidative stability at the film-substrate interface and by retention of dielectric strength at edge zones, not solely by the initial glass transition temperature. The cured material exhibits a glass transition temperature of 175–185 °C by differential scanning calorimetry, but the failure mechanism under continuous thermal load is localized oxidative microcracking at the copper or ITO interface after repeated excursions. Thermogravimetric analysis per ASTM E1131 shows a 5 % mass-loss onset above 420 °C under nitrogen and 365–375 °C in air. Under IEC 60216-1 and IEC 60216-6, with an endpoint of 50 % loss of initial dielectric strength, the material is classifiable as a 200 °C system at a 20,000 h service-life criterion for a 25 µm dry film on copper. A conventional alkyd varnish evaluated under the same protocol typically retains dielectric strength above 10 kV/mm only to 130–155 °C and loses flexibility due to oxidative embrittlement at the wire edge. Polyurethane wire enamels with a 155 °C thermal class maintain higher abrasion resistance but show a lower continuous-use ceiling than this polyimide-silicone hybrid. The specific difference is that the EL-grade product does not rely on a high filler loading for thermal stability; the aromatic imide segments provide thermal decomposition resistance, while low-free-volume silicone segments allow the 25 µm film to survive bending onto small-radius busbar corners without tensile cracking.

    On a production EL lamp screen-printing line, the coating is printed through a 120–160 mesh stainless steel screen with a polyurethane squeegee hardness of 70–75 Shore A at a pneumatic squeegee pressure of 0.18–0.32 MPa. A single pass deposits a wet-film thickness of 60–90 µm; after forced-air drying at 65–75 °C for 10 min and thermal cure at 200 °C for 20 min, the dry dielectric layer measures 18–28 µm. Pinhole density under a 500 V DC spark test on a 100 mm × 100 mm coupon remains below 0.05 mm⁻² when the substrate is corona-pre-treated PET with surface energy of at least 48 mN/m. On untreated polycarbonate or bare aluminum, pinhole density can exceed 0.15 mm⁻² because of surface-tension-driven dewetting during solvent flash-off. A four-zone conveyorized convection oven with independent airflow control is recommended; a single-zone box oven often produces non-uniform skin formation and batch-to-batch dielectric strength variation greater than ± 20 %. The critical process window for zone 3 cure temperature is 200 ± 5 °C; overshoot above 215 °C causes the surface to skin over before residual solvent diffuses out, forming microvoids that reduce dielectric strength below 70 kV/mm.

    Dielectric, Mechanical, and Solvent-Resistance Specifications

    Property Test method Representative value Test condition
    Solids content ASTM D2369 42 ± 2 % 110 °C, 60 min
    Viscosity ASTM D2196 420–580 mPa·s 25 °C, spindle 4, 20 rpm
    Dielectric strength IEC 60243-1 ≥ 85 kV/mm 25 µm dry film, 23 °C, oil immersion
    Volume resistivity ASTM D257 ≥ 1.0 × 1014 Ω·cm 25 °C, 500 V DC, 60 s electrification
    Thermal endurance IEC 60216-1 200 °C / 20,000 h 25 µm on copper, 50 % dielectric strength endpoint
    Flexibility ASTM D522 No cracks on 1 mm mandrel 25 µm dry film
    Pencil hardness ASTM D3363 4H 25 µm dry film on aluminum
    Solvent resistance ASTM D5402 > 200 MEK double rubs 25 µm dry film, 1 kg load
    Adhesion ASTM D3359 5B Copper with chemical conversion coating
    Halogen content IEC 61249-2-21 < 900 ppm total Cl + Br Homogeneous material

    Dielectric strength is recorded after 24 h post-cure stabilization at 23 ± 2 °C and 50 ± 5 % relative humidity. Values below 70 kV/mm at 25 µm are typically the result of incomplete solvent evaporation or incomplete imide conversion, and the cure state must be confirmed by infrared absorption for imide carbonyl at 1778 cm⁻¹ and 1725 cm⁻¹ rather than by dry-to-touch inspection. Volume resistivity is thickness-dependent below 15 µm; at 10 µm dry film, the value may fall to 8.0 × 1013 Ω·cm because of electrode surface roughness. The 5B adhesion rating is conditional on a chromate-free conversion coating or a 3–5 µm zinc phosphate layer; on bare rolled copper after 1,000 thermal cycles from −40 °C to 200 °C, crosshatch adhesion may degrade to 3B. Solvent resistance above 200 MEK double rubs applies only after full cure; a film cured for 10 min at 180 °C instead of the specified 20 min at 200 °C typically fails at 60–80 double rubs.

    When the Coating Is Applied to High-Density Inverter Transformer Windings

    In high-density inverter transformer windings, HTRIC-EL 550 is used as a thin-film secondary insulation layer over enameled copper wire rather than as a cavity-filling resin. The coating is applied by selective needle dispensing at a volumetric flow rate of 0.8–1.4 cm³/min through a 22 gauge stainless steel needle, with a needle-to-substrate gap of 100–150 µm. Wet-film thickness on the wire surface is maintained between 25 µm and 50 µm; a single-pass film build above 75 µm is not recommended because the outer surface skins during cure and traps residual cycloaliphatic solvent, causing void formation at the 200 °C step. The coating is compatible with polyamide-imide and polyester-imide wire enamels when a 10 min flash-off at 25 °C and 45–55 % relative humidity is inserted before thermal cure. Without this flash-off, solvent attack can soften the underlying wire enamel and reduce winding bond strength from 0.35 kN/cm² to below 0.20 kN/cm² after 1,000 thermal cycles from −40 °C to 200 °C. Thermal conductivity of the cured film is 0.22–0.28 W/m·K when measured by laser flash per ASTM E1461. This value is lower than that of filled epoxy slot-fill resins and therefore limits the material to external surface insulation duties rather than internal hot-spot diffusion applications.

    A direct substitution of a ceramic-filled epoxy coating with HTRIC-EL 550 is not equivalent. Ceramic-filled epoxies typically offer thermal conductivity of 0.8–1.2 W/m·K and compressive strength above 80 MPa, but they are qualified for thick sections above 200 µm and may crack when applied to flexible EL lamp circuits. In contrast, this EL-grade coating is intended for thin-film dielectric structures where pinhole resistance, flexure on small-radius bends, and dielectric strength matter more than bulk thermal conductivity. Compared with general-purpose polyurethane conformal coatings, the product provides a higher thermal class but requires a longer thermal cure and has a narrower solvent-balance window. At ambient relative humidity above 60 %, the material must be pre-dried at 35–40 °C for 30 min or applied under a nitrogen blanket to prevent water condensation from forming microvoids at the film-substrate interface. Mixing with amine-based additives is not permitted because basic amine accelerates silanol condensation in the wet state and shortens pot life below 4 h, producing screen clogging on automated lines.

    The solvent system is formulated for high flash point and controlled evaporation; closed-cup flash point is 42–46 °C per ASTM D3278. For spray application, dilution with the recommended cycloaliphatic ester diluent at 3–5 wt% is typical, but higher dilution reduces the solids content and increases the number of passes required to reach a 25 µm dry film, which in turn increases the risk of interlayer adhesion loss. Interlayer adhesion after oven aging at 200 °C for 500 h remains above 4B when the first layer is cured for 10 min at 200 °C before the second pass; if the first layer is only flash-dried at 80 °C, interlayer adhesion can fall to 2B due to solvent re-wetting and differential polymer diffusion.

    Rheological adjustments become shear-rate dependent in high-speed dispensing systems

    Batch-to-batch viscosity variation in the supplied material is controlled to ± 15 % of the nominal midpoint at 25 °C, but high-shear dispensing conditions generate a different apparent viscosity than the Brookfield low-shear value. At a shear rate of 1,000 s⁻¹, a cone-and-plate rheometer test per ASTM D4287 returns an apparent viscosity of 180–240 mPa·s, indicating shear-thinning behavior suitable for needle dispensing. Thinning with the recommended cycloaliphatic ester diluent may reduce viscosity to 120–150 mPa·s at 1,000 s⁻¹, but addition above 5 wt% lowers solids content below 40 % and increases sag tendency on vertical busbar surfaces. During screen printing, solvent evaporation from the flooded screen changes the viscosity at the aperture edge; the printing environment is therefore maintained at 22–26 °C and 40–50 % relative humidity with a solvent dew point below 10 °C. Solvent-retention measurements by headspace gas chromatography show residual cycloaliphatic solvent below 0.5 % of dry film mass after the specified cure cycle; residual levels above 1.5 % correlate with dielectric strength dispersion greater than ± 20 % across a single production lot. If viscosity in the reservoir rises above 650 mPa·s due to open-tank solvent loss, the material should not be reduced with high-aromatic thinners because the polyimide-silicone binder can precipitate, producing gel particles that block 22 gauge needles and leave uncoated areas around wire terminations.

    For rework, cured film is removed from copper or ITO by immersion in a 1-methyl-2-pyrrolidone-based stripper at 80 °C for 30–45 min; mechanical abrasion is not recommended for EL panel substrates because it scratches the ITO layer and changes sheet resistance by more than 10 %. Reworked substrates show a 5–15 % reduction in adhesion rating after recoating unless an oxygen plasma treatment at 200 W for 2 min is applied to restore surface energy to at least 50 mN/m.

    Unopened containers have a shelf life of 12 months from date of manufacture when stored at 5–25 °C. Storage below 5 °C may cause reversible precipitation of the polyimide-silicone binder; the material must be warmed to 25 °C and rolled for 2 h before use. After opening, the container should be blanketed with dry nitrogen if the material is not consumed within 8 h to prevent moisture ingress and solvent fractionation.

    Requirement Standard/regulation Status
    Restriction of hazardous substances RoHS 2011/65/EU Annex II including 2015/863 Pass
    REACH candidate list substances > 0.1 % w/w EC 1907/2006 Article 33 Not intentionally added
    Total halogen content IEC 61249-2-21 < 900 ppm Cl + Br
    Ozone-depleting substances Montreal Protocol Annex A/B Not present
    Vertical burn on FR-4 at 25 µm ASTM D6413 Self-extinguishing within 10 s; substrate dependent