| HS Code | 947372 |
| Product Name | Gold Plating Salt (Sumitomo Chemical AU-300) Electronic/EL Grade |
| Manufacturer | Sumitomo Chemical |
| Grade | Electronic/EL Grade |
| Chemical Name | Potassium dicyanoaurate(I) |
| Chemical Formula | KAu(CN)2 |
| Cas Number | 13967-50-5 |
| Molecular Weight | 288.10 g/mol |
| Appearance | White to off-white crystalline powder |
| Gold Content | Approximately 68.3% gold by weight |
| Purity | ≥99.9% gold-salt purity with controlled trace impurities |
| Solubility | Soluble in water; sparingly soluble in common organic solvents |
As an accredited Gold Plating Salt (Sumitomo Chemical AU-300) Electronic/EL Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Packaging: 100 g sealed container of Sumitomo Chemical AU-300 Gold Plating Salt, Electronic/EL Grade, for precision electroplating. |
| Container Loading (20′ FCL) | One 20′ FCL container of Gold Plating Salt (Sumitomo AU-300), Electronic/EL grade, securely packed and sealed for safe transport. |
| Shipping | Shipment of Gold Plating Salt (Sumitomo Chemical AU-300, Electronic/EL Grade) requires strict hazmat compliance. This material ships via ground transportation only, as it is classified as a hazardous substance. Proper UN-certified packaging, labeling, and documentation are mandatory. International air freight is prohibited. Signature and temperature-controlled handling may apply. Contact shipper for current regulatory details. |
| Storage | Store in the original, tightly sealed container in a cool, dry, well-ventilated area, away from direct sunlight, heat, and incompatible substances. Protect from moisture and physical damage. Maintain ambient room temperature and low humidity to preserve purity and prevent degradation. Label clearly and segregate from oxidizers and reactive chemicals to ensure safety. |
| Shelf Life | Shelf life is typically 12 months from manufacture when stored unopened in a cool, dry place, protected from moisture and contamination. |
In wafer-level bumping of 200 mm and 300 mm wafers, the Sumitomo Chemical AU-300 Electronic/EL Grade gold salt serves as the gold source for electroplated Au bumps on aluminum or copper bond pads. The plating cell is a fountain-type wafer plating tool with a recirculation rate of 20–40 L/min per 300 mm wafer and a filtration loop containing a 0.05 µm polypropylene depth filter. The make-up window for a sulfite-based gold bump bath operates at an Au(I) concentration of 8–15 g/L. The pH is held between 7.0 and 8.5 by sulfamic acid or potassium hydroxide additions. Bath temperature is controlled at 50–60 °C. The wafer is cathodically biased at 0.5–1.5 A/dm². The lower half of that current density range is used for fine-pitch bumps below 60 µm pitch. At current densities above 2.0 A/dm², nodule formation and tensile stress increase because gold deposition becomes mass-transport limited at the photoresist openings. Process control includes ICP-MS measurement of Fe, Ni, Co, Cu, and Ag at each shift. Fe and Ni above 1 mg/L produce roughness shifts and reduce bump height uniformity. Cu above 5 mg/L creates dendritic edge growth at the photoresist boundary. Peristaltic pumps and fluoropolymer tubing replace stainless steel fittings to minimize metallic contamination. The terminal products are flip-chip CSP packages, LCD driver ICs with Au-bump interconnects, and CMOS image sensor devices that require thermosonic or thermocompression bonding. Plated bump height is verified by white-light interferometry or contact profilometry. Published data for the AU-300 salt's vendor-specific impurity certificate is limited; achieved bath purity depends on make-up water, resist stripping residues, and anode bypass flow.
| Parameter | Range | Measurement | Deviation signal |
|---|---|---|---|
| Au(I) concentration | 8–15 g/L | Volumetric titration, once per shift | Bump height reduction at fixed current density |
| pH | 7.0–8.5 | Calibrated pH meter | Ductility loss below 6.8 |
| Bath temperature | 50–60 °C | NIST-traceable RTD | Organic brightener decomposition above 65 °C |
| Cathodic current density | 0.5–1.5 A/dm² | Rectifier current divided by exposed pad area | Nodule formation above 2.0 A/dm² |
| Filter pore size | 0.05–0.1 µm | Housing inlet/outlet pressure drop | Bath haze, particle-related porosity |
Hard gold for edge connector contacts requires cobalt or nickel codeposition to raise the deposit hardness. The AU-300 salt is reconstituted in an acid citrate electrolyte at 8–16 g/L Au. Cobalt or nickel is added as sulfate or citrate at 50–400 mg/L. The pH is controlled at 4.0–5.5. Bath temperature is maintained at 45–65 °C. Reel-to-reel selective plating uses a pressure jet cell with insoluble platinized titanium anodes. Current density is normally held at 0.5–2.0 A/dm². Below 0.5 A/dm², cobalt codeposition decreases and Knoop hardness can fall below 130 HK. Above 1.2 A/dm², cobalt transport becomes limiting and organic inclusion levels rise. RoHS Annex III restrictions on lead in plating baths require lead-free brightener systems. The terminal products are PCI Express edge connectors, DDR DIMM sockets, and backplane contacts. The deposit is qualified to MIL-DTL-45204D Type II Grade C or ASTM B488 Type II. The nickel underplate is 2.5–5.0 µm sulfamate nickel. The gold topcoat is 0.75–1.5 µm for high-insertion-cycle connectors. Porosity testing is performed by nitric acid vapor per ASTM B735. Adhesion is verified by bend test per ASTM B571. Solderability is assessed by J-STD-002D steam aging. The most frequent production failure is gold nodulation at the edge mask boundary. Nodulation occurs when current density exceeds the local mass transport limit in the jet cell. A second failure mode is hydrogen embrittlement in spring-hardened copper alloy contacts. Embrittlement risk increases when the carrier strip has not received adequate baking after plating. Batch-to-batch variance in the AU-300 salt's metallic impurity profile shifts the cobalt brightener consumption rate. Impurity control therefore includes liquid chromatography for brightener breakdown products and ICP-MS for Cu, Ni, Co, Fe, and Pb.
| Property | Test method | Typical acceptance |
|---|---|---|
| Gold thickness | ASTM B568 | 0.75–1.5 µm over 2.5–5.0 µm Ni |
| Knoop hardness | ASTM B578 | 130–200 HK |
| Porosity | ASTM B735 | No through-porosity to Ni |
| Adhesion | ASTM B571 | No blistering or lift after bend |
| Solderability | J-STD-002D | ≥95% wetted area |
| Composition | SEM/EDS or XRF | Au ≥99.0 wt%; Co or Ni <1 wt% |
For multilayer ceramic packages with Kovar or Alloy 42 leads, the gold salt is used in barrel or vibratory plating after a sulfamate nickel strike. Military and aerospace ceramic packages generally specify soft gold. The applicable finish is MIL-DTL-45204D Type I Grade A or ASTM B488 Type I. Lead-frame gold thickness is 1.27–2.54 µm. The bath make-up uses 8–12 g/L Au. pH is maintained at 6.5–8.0. Temperature is held at 55–70 °C. Cathodic current density is 0.2–0.8 A/dm². The low current density prevents excessive stress and maintains ductile grain structure. Soft gold deposits must withstand wire bonding and package seam sealing without cracking. Solderability is evaluated by J-STD-002D after 8 h steam aging. Hermeticity is verified by MIL-STD-883 Method 1014. Wire bond integrity is analyzed by MIL-STD-883 Method 2011 destructive bond pull and Method 2019 die shear. Failure modes include nickel diffusion from the underplate when the gold layer is below 1.0 µm. Nickel diffusion produces a non-solderable surface after high-temperature storage. The barrel plating process is limited by rotational speed. Excessive tumbling creates mechanical abrasion at lead tips. Insufficient rotation produces non-uniform gold distribution in the barrel center. The terminal products are space-qualified ceramic FPGAs, crystal oscillators, and optocouplers.
Electroless gold deposition on immersion nickel is not a Faradaic diffusion-limited process. The replacement reaction is self-limiting because the nickel surface passivates as gold coverage becomes continuous. The AU-300 salt is used to make an electroless gold replenisher at 0.5–2.0 g/L Au. The pH is maintained between 5.0 and 6.0 for acidic electroless gold. Bath temperature is controlled at 80–90 °C. Immersion time is 7–12 min. The resulting gold thickness is 0.05–0.15 µm over an electroless nickel layer of 3–6 µm. This stack conforms to IPC-4552A. The most serious process defect is black pad. Black pad originates from hyperlocal phosphorus-rich nickel corrosion. It is detected after gold stripping by scanning electron microscopy. Nickel ion drag-in above 10 mg/L destabilizes the bath and shortens bath life. Stabilizer addition is controlled by an automatic replenishment loop. Surface finish ionic contamination is measured per J-STD-001 for assemblies. The terminal products are HDI PCB solder pads, BGA package substrates, and wire-bondable chip-on-board surfaces. Production-scale rack lines must isolate ENIG tanks from acid copper baths to prevent mist transport. Drag-out recovery and countercurrent rinses reduce palladium contamination. Published data for electroless AU-300 bath life in high-throughput HDI lines is limited.
Microwave and satellite waveguide assemblies require thick soft gold on aluminum or brass flanges. The AU-300 salt is used in a low-stress rack plating bath. The bath make-up uses 8–12 g/L Au. pH is held at 6.8–7.2. Temperature is maintained at 50–60 °C. Current density is limited to 0.2–0.5 A/dm². The low current density is necessary because thick deposits accumulate internal stress. The gold thickness is 3–5 µm per ASTM B488 Type I Grade A. The basis metal is machined brass or aluminum. A copper strike and a 2.5–5.0 µm sulfamate nickel underplate precede gold plating. Surface roughness of the basis metal is held below 0.4 µm Ra before plating. Gold replicates the substrate roughness. Raised roughness increases passive intermodulation in waveguide transmission. Thickness uniformity is checked by ASTM B568 X-ray fluorescence at five locations on each flange. Adhesion is tested by thermal cycling from -65 °C to +125 °C per MIL-STD-883 Method 1010.8. Failure modes include blistering at the nickel-gold interface and edge build-up at flange bolt holes. Edge build-up is controlled by conforming anode placement. The terminal products are satellite waveguide filters, phase shifter housings, and T/R module frames. Published data for AU-300 bath lifetime in thick rack gold plating is limited.
In LED and optoelectronic lead frames, silver-plated copper or Alloy 194 is selectively plated with a thin gold topcoat for wire bonding and sulfidation protection. The AU-300 salt is used in a reel-to-reel spot plating line. The gold bath is operated at 1–4 g/L Au. pH is controlled between 6.5 and 7.5. Temperature is held at 45–60 °C. Current density is 0.5–2.0 A/dm². Gold thickness is 0.2–0.5 µm on the wire-bond pad. The gold overplate blocks atmospheric sulfur from converting silver to Ag2S. Silver migration under DC bias follows an Arrhenius temperature dependence. At 85 °C and 85% RH, silver ion transport accelerates along condensed moisture films. Sulfur-containing mold compound outgassing intensifies dendrite formation. Gold thickness below 0.1 µm leaves through-porosity that permits Ag2S film growth. Thickness above 0.8 µm increases solder joint embrittlement after die attach. The plated lead frame is tested for wire bond shear per JESD22-B116. Sulfidation resistance is evaluated by mixed flowing gas testing per ASTM B827. The terminal products are PLCC LEDs, automotive optocouplers, and light sensor modules. The main production failure is misregistration of the spot plating mask. Misregistration allows gold bleed onto the solder pad. Gold bleed changes solder joint intermetallic composition. Optical inspection with a 2 µm resolution camera verifies spot position.
Competitive Gold Plating Salt (Sumitomo Chemical AU-300) Electronic/EL Grade prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8615365186327
Email: admin@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
The procurement specification for gold plating salts used in semiconductor packaging and high-reliability electrical interconnect fabrication is driven primarily by the concentration of non-gold metallic impurities and by the consistency of the gold metal content rather than by nominal appearance. Sumitomo Chemical AU-300 is supplied as an Electronic/EL grade gold plating salt, a designation that places it within the tighter impurity-control band used for gold electrodeposition where wire-bond reliability, solderability, and interfacial voiding after thermosonic bonding are acceptance criteria. The product is intended for controlled bath preparation and replenishment in gold electroplating electrolytes; the exact ligand system, inhibitor package, and lot-specific certificate-of-analysis values are not reproduced in general technical literature. Where application-specific data for AU-300 are unavailable, the term Electronic/EL grade implies the salt is supplied with documented impurity ceilings rather than the broader limits accepted for decorative or general-purpose gold salts. In cyanide-based plating salts, the stoichiometric gold content of potassium gold cyanide is 68.2 wt%, and electronic-grade products are commonly specified within a narrow lot-to-lot window around the theoretical value; for non-cyanide systems, the metal content is lower and must be confirmed by density or absorbance before bath make-up.
Sumitomo Chemical AU-300 is identified by the model designation AU-300 and the Electronic/EL grade classification. The Electronic/EL grade suffix is used in semiconductor and connector supply chains to denote electronic-grade purity; it is not a claim of electroless operation unless explicitly stated on the lot certificate. Electronic/EL grade gold salts are normally offered with certificate-of-analysis documentation that includes gold metal content, moisture content, and trace impurity values. The supplier has not published a complete AU-300 specification in open technical literature; therefore, the numerical values that follow are representative industrial benchmarks for this grade and not lot-specific AU-300 data. Buyers must request the certificate of analysis for each lot and compare it with the bath impurity budget before issuing a batch release.
Electronic/EL grade gold plating salts are differentiated less by gold content than by the parts-per-million budget for trace metals that compete with gold deposition or form high-resistance intermetallic phases. In wire-bond and solder-terminal applications, lead, cadmium, copper, nickel, iron, and zinc are controlled because their co-deposition can reduce 99.99% gold deposit purity and change the wire-bond pull strength distribution. The following representative benchmark values are derived from industry technical bulletins for electronic-grade gold salts and are not lot-specific AU-300 certification data; they serve as a comparison baseline for incoming chemical inspection. A buyer evaluating AU-300 would require the actual certificate of analysis and would verify the measurement method against ISO 17294-2:2016 or an equivalent inductively coupled plasma mass spectrometry procedure. In addition to cationic impurities, chloride and sulfate are frequently limited to avoid bath drag-in effects that alter anode corrosion and organic additive breakdown. Particles are controlled through final filtration at the chemical packaging stage and through in-tank filtration at 0.1 µm to 0.2 µm absolute in semiconductor-grade installations.
| Element or anion | Typical upper control limit (mg/kg) | Common analytical method |
|---|---|---|
| Lead (Pb) | 2 | ICP-MS, ISO 17294-2:2016 |
| Cadmium (Cd) | 1 | ICP-MS, ISO 17294-2:2016 |
| Copper (Cu) | 3 | ICP-MS or ICP-OES |
| Nickel (Ni) | 3 | ICP-MS or ICP-OES |
| Iron (Fe) | 5 | ICP-MS or ICP-OES |
| Zinc (Zn) | 3 | ICP-MS or ICP-OES |
| Chloride (Cl) | 20 | Ion chromatography |
| Sulfate (SO₄) | 20 | Ion chromatography |
The lot-to-lot variance of the salt is as critical as the absolute impurity level. Electronic gold plating baths are typically operated at low gold metal concentrations, and replenishment is often automated through ampere-hour counters; if the salt dissolution rate or the apparent gold content varies by more than ±0.5 wt%, the bath gold concentration shifts outside statistical process control. Incoming inspection should include Fourier-transform infrared spectroscopy if the ligand system is cyanide, UV-visible absorbance for gold concentration, and moisture content by Karl Fischer titration when the salt is hygroscopic. Process engineers in high-volume connector lines have reported that uncontrolled moisture in raw plating salts increases the risk of localised pH excursions during make-up, which in cyanide baths generates hydrogen cyanide vapour. Therefore, the Electronic/EL grade packaging and handling recommendations are part of the product specification, not an ancillary safety note.
For high-speed reel-to-reel spot plating of LED leadframes or press-fit connectors, the replenishment model is normally based on the ampere-hour integral rather than on manual addition. A cell processing 40,000 contacts per hour can consume gold at a rate that shifts the bath metal concentration by 0.5 g/L within a single shift if the salt feed is not matched to the rectifier output. AU-300 as a dry salt is dissolved in high-purity water to prepare a concentrated gold solution; the concentrate is then metered into the working bath through a closed dosing loop. The make-up water should conform to ASTM D1193 Type I or equivalent with resistivity not less than 18 MΩ·cm at 25 °C. Bath agitation is preferably generated by eductor or cathode-rod reciprocation rather than air agitation, because air oxidation of cyanide bath components and carbonate accumulation alter pH response and current efficiency. Filtration through a 0.2 µm polypropylene cartridge is standard; however, on tanks with hard gold alloy additions the filter media must be checked for adsorption of polymeric brighteners.
Substitution of an Electronic/EL grade salt into an existing cyanide gold bath requires a controlled transition rather than direct addition. The first difference is analytical: the electronic salt is usually supplied with a certified impurity report, but the operating bath already contains accumulated base metals. Unless the bath is treated by dummy plating or partial bleed-and-feed, the beneficial purity of the new salt is masked by the residual copper, nickel, or iron content of the aged electrolyte. The transition protocol normally includes a 50% partial dump, a carbon or selective ion-exchange treatment if organic brightener breakdown is suspected, and a dummy-plating step at 0.1 A/dm² to 0.2 A/dm² for 2 to 4 ampere-hours per litre. The operating window for cyanide electronic gold plating salts is typically maintained at 60 °C to 70 °C, with pH between 6.0 and 7.5. The acceptable pH range narrows when the bath operates above 65 °C because carbonate formation and cyanide decomposition accelerate; pH drift above 7.5 tends to reduce current efficiency and may create a deposit with lower density and higher porosity.
| Parameter | Rack/barrel operating range | High-speed selective operating range |
|---|---|---|
| Gold metal concentration | 8–20 g/L | 10–25 g/L |
| Bath temperature | 60–70 °C | 55–70 °C |
| pH | 6.0–7.5 | 6.0–7.2 |
| Cathode current density | 0.2–1.0 A/dm² | 5–50 A/dm² |
| Anode type | Platinized titanium or mixed oxide | Platinized titanium or insoluble dimensionally stable anode |
| Agitation | Cathode rod or eductor flow | Impinging solution jet or flooded cell |
| Filtration | 0.1–0.2 µm absolute cartridge | |
The largest process risk during substitution is the interaction between the new salt’s impurity profile and the existing brightener system. Cyanide gold baths used for connectors often contain cobalt, nickel, or iron as hardening and brightening metals; these are deliberately added, but their oxidation products are controlled by wetting agents and complexants. A high-purity salt without compensating additives can change the brightener-to-carrier ratio, producing step burn or non-uniform alloy distribution. Therefore, process engineers sometimes conduct a Hull cell test at 1 A for 5 min using the existing bath mixed with the proposed salt lot before full addition. The Hull cell panel is then evaluated for burnt deposits at high current density and for dull deposits at low current density; those boundaries define the production current density range more reliably than the rectifier nameplate.
Compared with industrial-grade potassium gold cyanide, the Electronic/EL grade AU-300 is specified for lower trace base-metal content and for lot-to-lot consistency under high-speed plating conditions. General-purpose gold salts often contain copper and iron at concentrations that are acceptable for decorative hard gold but are unacceptable for wire-bondable soft gold. The raw salt in electronic use is normally free of pre-blended brightener packages; hard gold systems used in decorative and functional plating often include cobalt or nickel brightener mixtures in the replenisher, whereas electronic plating systems add the hardening metal separately if needed. This separation prevents the impurity signature of the salt from being obscured by the additive package and allows the bath to be analysed for trace metals without the interference of organic degradation products.
For gold plating on palladium-coated leadframes or on selectively masked printed circuit boards, thickness uniformity is influenced more by bath conductivity and primary current distribution than by the raw salt lot. Electronic/EL grade salts with low sodium and sulfate contamination reduce the uncontrolled electrolyte conductivity shift during long replenishment cycles; this is why the anionic impurity budget appears in supplier specifications as a separate line item from cationic impurities. In reel-to-reel plating, the thickness at the centre of the contact can exceed the edge thickness by 20% to 50% unless shield plates or conforming anodes are used. The plating salt itself is not a corrective agent for poor cell geometry, but a salt with consistent metal content prevents thickness drift from chemical sources. On a production line running 24 h/day at a nominal gold deposition rate of 2 µm/min under high-speed jet conditions, the replenishment rate is calculated from the rectifier ampere-hours and the actual deposition efficiency; error in the salt’s gold content by 1 wt% produces a corresponding cumulative error in bath concentration if the dosing algorithm assumes a fixed metal value.
Analytical control loops for such baths typically use UV-visible spectroscopy for gold concentration, pH meter with temperature compensation to ±0.05 pH, and density measurement for concentrated make-up solution. The gold concentration in the working bath is often maintained within ±0.5 g/L of the set point to maintain deposit thickness within ±10% at constant current density. This is particularly important when the plated component is subsequently subjected to mixed flowing gas corrosion testing per IEC 60068-2-60 or ASTM B845; porous or thin gold will allow corrosion of the underlying nickel or copper. Electronic/EL grade raw material does not by itself guarantee pore-free deposits; it removes one class of defect sources from the input side of the process.
Handling of cyanide-based gold plating salts requires segregation from mineral acids and oxidising agents. Acidification of a cyanide electrolyte below pH 4 releases hydrogen cyanide; therefore, the salt must be stored in a locked, dry, ventilated chemical cabinet away from nitric acid and peroxides. Waste treatment must include oxidation of free cyanide under alkaline conditions, usually with sodium hypochlorite at pH above 10.5 and ORP above +400 mV, followed by precipitation and recovery of gold by ion exchange or electrochemical winning. Sulfite-based gold salts, when used instead of cyanide, operate at lower pH but are less stable in high-speed cells and can precipitate elemental gold on storage. The choice of AU-300 over non-cyanide alternatives is therefore an engineering decision based on deposition speed, bath stability, waste-treatment cost, and the substrate’s tolerance for alkaline cyanide exposure. The Electronic/EL grade designation addresses raw material purity, but the final deposit performance remains a function of the plating cell design, the replenishment control system, and the analytical frequency. End users must verify each production lot against the lot-specific certificate of analysis because supplier-grade classifications do not transfer without incoming inspection.