| HS Code | 588994 |
| Product Name | Gold Plating Salt Electronic/EL Grade |
| Chemical Name | Potassium gold cyanide |
| Chemical Formula | KAu(CN)2 |
| Cas Number | 13967-50-5 |
| Molecular Weight | 288.10 g/mol |
| Gold Content | 68.3% minimum |
| Purity | Electronic/EL grade (≥99.9%) |
| Appearance | White crystalline powder |
| Odor | Odorless |
| Density | 3.45 g/cm3 at 20°C |
| Decomposition Temperature | Approximately 200°C |
| Solubility In Water | Soluble |
As an accredited Gold Plating Salt Electronic/EL Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Available in 100 g amber glass bottle with airtight seal, nitrogen-purged for electronic/EL grade gold plating salt stability. |
| Container Loading (20′ FCL) | Gold Plating Salt Electronic/EL Grade is loaded in a 20′ FCL using palletized, sealed drums, properly secured and labeled for safe transport. |
| Shipping | Shipping description: Hazardous material — proper shipping name “Cyanides, inorganic, solid, n.o.s. (potassium gold cyanide),” UN1588, Class 6.1, Packing Group II. Pack in UN-certified, tightly sealed containers with absorbent inner cushioning. Label as Toxic, protect from moisture/acids, and attach dangerous goods declaration for transport. |
| Storage | Store Gold Plating Salt (Electronic/EL Grade) in a cool, dry, well-ventilated area in its original, tightly sealed container. Protect from moisture, heat, and direct sunlight. Keep away from acids, oxidizers, and incompatible materials. Ensure the storage area is secured, clearly labeled, and accessible only to trained personnel. |
| Shelf Life | Shelf life is indefinite if stored properly in sealed original container, protected from light, moisture, and contamination under ambient conditions. |
Wafer-level packaging lines processing 300 mm silicon and fan-out panel substrates consume the largest share of electronic-grade gold plating salt in bump metallization. In these lines, a sputtered TiW/Au seed layer or an electroplated Cu/Ni under-bump metallization stack is patterned with thick photoresist, and gold is electrodeposited through the resist openings in a cup-type fountain plater equipped with platinized titanium anodes and paddle agitation. The high-purity gold sulfite or cyanide citrate electrolyte is maintained at pH 4.2–4.8 and 55–65 °C, with a current density of 2.0–6.0 A/dm². The deposit thickness for subsequent wire bonding or thermosonic flip-chip connection is typically 15–25 µm, with a Knoop hardness of 60–90 HK25 under ASTM B488 Type III purity of 99.9%. Metal impurities above 5 mg/kg for Fe, Ni, Co, Cu, and Pb in the salt produce nodular growth and increase surface roughness because the impurities adsorb preferentially on high-current-density sites. Organic degradation products from photoresist leaching accumulate in the bath and reduce current efficiency at the edge of the wafer; batch-life termination is therefore governed by total organic carbon rather than gold depletion in most production lines. Adhesion failures after wire pull testing are commonly traced to bath contamination by iron from stainless steel transfer piping when anolyte and catholyte compartments are not separated. Salt containers opened in cleanrooms above 60% relative humidity require pre-drying at 80 °C for 24 h before gravimetric bath make-up to prevent weighing drift from absorbed moisture.
Gold fingers on printed circuit boards for PCIe, DDR, and backplane applications are plated in vertical in-line or reel-to-reel cells in which the board edge is immersed in a hard gold bath. The electronic-grade gold salt is blended with proprietary cobalt or nickel salts to produce codeposits containing 0.1–0.3 wt% Co or Ni, raising hardness from 60–90 HK25 to 130–190 HK25. The electrolyte is maintained at 40–60 °C and pH 3.8–4.5, with current densities of 1.0–4.0 A/dm². Nickel chloride or nickel sulfamate is applied as an underplate at 2.5–5.0 µm, while hard gold thickness is held at 0.75–1.25 µm. Porosity at this thickness is a direct function of organic brightener concentration; excess brightener increases ductility but creates microscopic voids revealed by ASTM B735 nitric acid vapor tests. Contact resistance after 500 mating cycles is required to remain below 10 mΩ according to IEC 60512-2-1, and surface wear resistance is typically evaluated by reciprocating wear with a 100 g load over 10,000 cycles. Bath contamination by tin or lead above 10 mg/kg causes dull deposits and reduces solder wetting after press-fit assembly, so EL-grade salt with single-metal impurities below 5 mg/kg is specified. Rack plating lines running at the lower current density bound produce a finer grain size but reduce throughput; production facilities therefore operate near 3.5 A/dm² only when anode-to-cathode spacing is maintained within ±5 mm to avoid edge burn on panel borders.
Skin depth constraints in millimeter-wave interconnects, specifically in 28 GHz and 77 GHz automotive radar phased-array transceivers, control the minimum gold thickness on inner conductors and connector bodies. At 28 GHz the skin depth in gold is approximately 0.45 µm, and at 77 GHz it falls to about 0.27 µm; manufacturers therefore specify gold thickness of 0.8–1.5 µm to ensure that more than three skin depths carry current and that insertion loss remains stable after thermal cycling. Cyanide-free gold sulfite baths are preferred for these parts because cyanate decomposition products can co-deposit as organic inclusions that raise surface roughness from Rz 0.2–0.4 µm to above Rz 0.8 µm. The bath is operated at 45–60 °C and pH 8.5–9.5 with a current density of 0.5–2.0 A/dm² to maximize throwing power into 0.3 mm inner bore diameters. Ferromagnetic impurities in the gold salt are critical for passive intermodulation performance in base station connector arrays; Fe, Ni, and Co are each limited to 5 mg/kg, and nonvolatile residue after calcination is specified below 10 mg/kg. Thickness distribution across a 12-port connector body is measured by X-ray fluorescence on 32 points, and the coefficient of variation must be below 8% to avoid impedance mismatch at 77 GHz. Bath aging under high air agitation accelerates sulfite oxidation to sulfate; sulfate concentration above 40 g/L causes deposit dulling and is controlled by batch sulfite replenishment rather than continuous feed.
| Application | Bath type | pH | Temperature (°C) | Current density (A/dm²) | Thickness (µm) |
|---|---|---|---|---|---|
| Wafer bumping / UBM | cyanide citrate or sulfite | 4.2–4.8 | 55–65 | 2.0–6.0 | 15–25 |
| Edge connector hard gold | cyanide + Co/Ni | 3.8–4.5 | 40–60 | 1.0–4.0 | 0.75–1.25 |
| RF/microwave connectors | sulfite | 8.5–9.5 | 45–60 | 0.5–2.0 | 0.8–1.5 |
| MEMS microcontacts | sulfite | 8.0–9.5 | 45–55 | 0.5–1.5 | 2.0–5.0 |
| GaN/SiC die attach | cyanide citrate | 4.2–4.8 | 60–70 | 1.0–4.0 | 1.5–3.0 |
| Medical feedthroughs | sulfite | 7.0–9.0 | 45–55 | 0.5–1.5 | 1.0–2.0 |
| Solderable hybrid pads | neutral citrate/sulfite | 5.8–6.5 | 50–60 | 0.5–2.0 | 0.5–1.0 |
RF MEMS ohmic switches and cantilever beam relays represent a process conflict between throughput and deposit cleanliness. The gold salt must produce a deposit soft enough to maximize contact area under a 20–80 µN actuation force, but the bath must remain free of organic brighteners that raise stiction and increase adhesion work after release. Gold sulfite electrolytes are operated at pH 8.0–9.5 and 45–55 °C with current density limited to 0.5–1.5 A/dm² because above 2.0 A/dm² the deposition becomes mass-transport-limited and produces nodular growth on beam edges. The plated gold thickness on RF MEMS contacts is 2.0–5.0 µm, with hardness between 40 and 70 HK25, which is lower than hard gold used on connectors and incompatible with sliding wear but necessary for low contact resistance below 2 mΩ at 1 V and 1 mA. The salt lot used for MEMS plating is filtered through 0.05 µm membranes and sampled for total organic carbon; lots exceeding 200 mg/L of TOC in the prepared bath are rejected because organic carbon reduces the gold grain size and increases the average roughness from 1.5 nm to over 5 nm. Adhesion to the silicon nitride or silicon oxide release layer is tested by tape pull after a 300 °C vacuum bake; failures at the gold-to-seed interface are frequently caused by trace sulfate carryover rather than mechanical stress in the cantilever. Published data for organic brightener thresholds below 0.1 vol% in sulfite gold baths for MEMS is limited; process qualification therefore must rely on wafer-level contact resistance mapping rather than bulk bath analytics alone. The same bath cannot be shared with edge connector hard gold electrolytes because cobalt or nickel contamination above 2 mg/kg changes the MEMS contact surface energy and increases stiction after the first actuation cycle.
Wide-bandgap power devices for 650 V and 1200 V modules require gold surfaces on die backside metallization for Au80Sn20 eutectic die attach. The gold layer is deposited over electroless nickel or sputtered Ti/Ni adhesion layers at 1.5–3.0 µm, and it must remain oxide-free through storage periods of up to 12 months before soldering. The gold salt used in this process is a cyanide citrate type maintained at 60–70 °C and pH 4.2–4.8, with current density of 1.0–4.0 A/dm² and gentle cathode rod agitation. The resulting soft gold has a hardness of 60–90 HK25 and a purity of 99.9% or greater, but the limiting impurity is not base metals; thallium at concentrations above 2 mg/kg in the salt changes grain structure and accelerates gold dissolution into molten Au80Sn20, shifting the reflow profile by 5–8 °C. Solder wetting is evaluated by the spread ratio of a 3.0 mm diameter Au80Sn20 preform at 305 °C under forming gas, with a required wetting area above 90%. Module manufacturers specify gold thickness uniformity of ±0.25 µm across a 200 mm wafer; this is achieved by shielded anode configurations rather than by increasing current density, because higher current density roughens the deposit and creates void lines at the die edge after reflow. A documented incompatibility exists with photoresist strippers containing N-methylpyrrolidone, which leave residues that inhibit gold nucleation on the sputtered seed layer; oxygen plasma descum is required before plating.
Implantable pulse generator assembly lines that electroplate titanium alloy feedthroughs and Pt-Ir electrode contacts use salt lots certified against ISO 10993-5 for cytotoxicity and ISO 10993-12 for extractable heavy metals. Gold sulfite rather than cyanide formulations is specified because the absence of free cyanide simplifies cleaning validation and reduces the risk of cyanide residue on alumina ceramic surfaces. The bath is maintained at pH 7.0–9.0 and 45–55 °C with a current density of 0.5–1.5 A/dm², and gold thickness is limited to 1.0–2.0 µm on implantable contacts. The EL-grade salt is supplied with certificates of analysis listing Fe, Ni, Co, Cu, Pb, and Cd below 5 mg/kg and endotoxin below 0.25 EU/mL when the prepared electrolyte is filtered through a 0.2 µm capsule filter. Adhesion testing follows ASTM B571 for bent-wire specimens; delamination of more than 5% of the plated area after thermal cycling from 37 °C to 200 °C is cause for rejection. Porosity is tested by gel electrography at 4.5 V in 0.1 M KCl, and a single pore larger than 0.25 mm is not acceptable on a sealed feedthrough surface.
| Application | Governing standard | Critical impurity/process limit | Test method |
|---|---|---|---|
| Wafer bumping | MIL-DTL-45204D Type III / ASTM B488 Type III | Fe, Ni, Co, Cu, Pb <5 mg/kg | ICP-MS after acid digestion |
| Edge connector hard gold | MIL-DTL-45204D Type II | Co or Ni 0.1–0.3 wt% | XRF / atomic absorption |
| RF/microwave connectors | IEC 62037 series passive intermodulation | Fe, Ni, Co <5 mg/kg | ICP-MS |
| MEMS microcontacts | ASTM B488 Type I | TOC <200 mg/L | combustion / NDIR |
| GaN/SiC die attach | MIL-STD-883 method 2003 / MIL-PRF-38534 | Tl <2 mg/kg | ICP-MS |
| Medical feedthroughs | ISO 10993-5 / ISO 10993-12 | Pb, Cd, Fe, Ni, Co, Cu <5 mg/kg | ICP-MS / AAS |
| Solderable hybrid pads | MIL-STD-883 method 2003 | Au thickness 0.5–1.0 µm | XRF |
Hybrid microcircuits and ceramic chip carriers sometimes require solderable gold pads on thick-film gold conductors, where a nickel underplate is not always compatible with the conductor composition. The critical boundary condition is not plating speed but the thickness of gold that dissolves into the solder joint. For Sn63/Pb37 and SAC305 alloys, gold concentrations above 2.0–3.0 wt% in the solder fillet form AuSn4 platelets that reduce shear strength by 30–50%; consequently, gold thickness on solderable terminations is held to 0.5–1.0 µm, not the 1.5–3.0 µm used for Au80Sn20 die attach. The gold salt is operated at pH 5.8–6.5 and 50–60 °C with current density of 0.5–2.0 A/dm² to avoid burning at the edge of screen-printed gold conductors. A neutral citrate or sulfite formulation avoids attack of the underlying silver-palladium or gold paste. MIL-STD-883 method 2003 is used to assess solderability after 8 h steam aging; wetting must exceed 95% of the pad area. Process control records for this application track gold thickness by X-ray fluorescence every 15 min, because a drift of 0.3 µm changes the gold-to-tin ratio from 1.0 wt% to 2.5 wt% on a 100 µm solder bump. Printed wiring assemblers occasionally request thicker gold for corrosion resistance; that request is incompatible with soldering without complete gold removal by a solder dip before joint formation.
Competitive Gold Plating Salt Electronic/EL Grade prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8615365186327
Email: admin@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Gold Plating Salt Electronic/EL Grade, reference model AuEL-68, is a high-purity potassium dicyanoaurate(I) crystalline material formulated for electrolytic gold deposition on electronic connectors, printed-circuit edge contacts, leadframes, and semiconductor packaging interposers. The product is specified with a minimum gold content of 68.2% w/w and is supplied without organic brighteners, grain refiners, or dye compounds. This compositional restriction distinguishes it from decorative gold salts that are compounded with cobalt, nickel, or iron brightener systems, and from general technical-grade salts that carry higher loadings of tramp-metal impurities. The crystalline solid is freely soluble in deionized water under alkaline conditions. Solution makeup at pH below 11.0 is contraindicated; cyanide-bearing gold complexes are acid-labile, with hydrogen cyanide evolution becoming significant below approximately pH 3.0. Packaging consists of sealed high-density polyethylene containers purged with nitrogen to limit carbonate and moisture uptake during storage.
Electronic/EL grade is defined primarily by the absence of organic additives and by tightened limits on tramp-metal contaminants. In hard gold plating for sliding contacts, cobalt or nickel is added separately as a sulfate or citrate; the gold salt itself does not contain alloying metal. Decorative products are often compounded with proprietary grain refiners that can introduce carbon into the deposit if the bath is converted to high-frequency or high-temperature electronic service. The EL salt is therefore specified when contact-resistance stability, thermosonic wire bondability, and solderability are qualification criteria. Electrolytic gold salts are additionally aligned with coating specifications in ISO 27874:2008 and ASTM B488-18, which define purity grades, hardness classes, and thickness requirements for electronic connectors. General technical salts are not usually qualified against these electronic specifications because their trace-metal load shifts deposit corrosion resistance and wire-bond pull strength. The difference is not merely assay percentage; it is measured by the concentration of Pb, Fe, Cu, Ni, Zn, and Ag that enter the bath with each replenishment cycle.
| Parameter | AuEL-68 Electronic/EL Grade | Decorative Grade Typical | Test Method |
|---|---|---|---|
| Iron | ≤5 mg/kg | ≤20 mg/kg | ISO 11885:2007 |
| Copper | ≤3 mg/kg | ≤10 mg/kg | ISO 11885:2007 |
| Lead | ≤5 mg/kg | ≤20 mg/kg | ISO 11885:2007 |
| Nickel | ≤5 mg/kg | ≤15 mg/kg | ISO 11885:2007 |
| Zinc | ≤5 mg/kg | ≤10 mg/kg | ISO 11885:2007 |
| Silver | ≤10 mg/kg | ≤25 mg/kg | ISO 11885:2007 |
| Cadmium | ≤1 mg/kg | ≤5 mg/kg | ISO 11885:2007 |
| Total non-gold metallic impurities | ≤25 mg/kg | ≤100 mg/kg | Sum by ISO 11885:2007 |
| Water-insoluble matter | ≤0.1% w/w | ≤0.5% w/w | Gravimetric, 1 µm membrane |
| Organic additives | Not detected | Present | Fourier transform infrared screening |
Continuous selective plating of connector strip with AuEL-68 typically operates with a bath gold concentration of 8 g/L to 20 g/L, free potassium cyanide at 10 g/L to 20 g/L, temperature between 60 °C and 70 °C, and pH between 9.0 and 9.5 when cobalt-alloyed hard gold deposits are required. The salt is added after dissolution in a separate alkaline make-up tank; direct addition to an acidic working bath is prohibited. Process experience on reel-to-reel lines with anode-to-cathode gaps of 0.3 mm to 0.8 mm shows that metallic contamination in the gold salt appears as dull, high-resistance deposit in low-current-density zones when combined Fe+Cu+Ni exceeds 25 mg/L in the working bath. Because the electronic/EL salt contributes less than 0.15 mg/L of these metals per 10 g/L gold make-up, dummy plating after new bath make-up can often be limited to 0.5 Ah/L to 1.0 Ah/L before production. Carbonate concentration is monitored by ion-selective electrode or titration; values above 90 g/L K₂CO₃ reduce cathode efficiency and require precipitation or freezing-out treatments.
At gold concentrations above 20 g/L, drag-out losses increase and gold is wasted in rinse water; below 8 g/L, limiting current density falls and thickness distribution deteriorates. The make-up procedure for AuEL-68 requires wetting the crystals with deionized water before adding potassium hydroxide or potassium cyanide to maintain alkalinity. The dissolution tank is filled to 80% volume with deionized water, heated to 50 °C, and agitated at 200–300 rpm. The salt is added slowly over 30 min; undissolved particles are removed by filtration. Direct addition of acid to the gold salt solution generates hydrogen cyanide gas; the area must have continuous HCN detection with alarm setpoints below 4.7 ppm ceiling. Spent baths and drag-out rinses from AuEL-68 must be segregated from acid waste streams to prevent cyanide gas release. Cyanide destruction uses alkaline chlorination or hydrogen peroxide oxidation; gold recovery from spent bath and rinse water by electrowinning or ion exchange is standard. The electronic/EL salt’s low metallic contamination simplifies gold recovery because fewer base-metal impurities are co-deposited on the electrowinning cathode.
Suppliers certify AuEL-68 against a typical release limit of Au 68.2% w/w minimum, KAu(CN)₂ content 99.0% w/w minimum on the dry basis, chloride 10 mg/kg maximum, and water-insoluble matter 0.1% w/w maximum. The pH of a 10% w/w aqueous solution at 25 °C is controlled between 10.8 and 11.5. No organic brightener or grain refiner is present. Gold content is confirmed by fire assay after cyanide destruction; trace-metal impurities are measured by inductively coupled plasma optical emission spectrometry following peroxide-citrate digestion. Batch homogeneity is verified by sampling at 3 container points per lot, with all analytical results reported on the certificate of analysis. The salt is dissolved by slow addition to deionized water at 50 °C to 60 °C with continuous stirring in a polypropylene or stainless-steel tank. The concentrated gold solution is filtered through a 1 µm absolute cartridge before transfer to the plating cell.
| Parameter | Range or Requirement | Reference |
|---|---|---|
| Bath gold concentration | 8–20 g/L | Supplier bath datasheet |
| Free potassium cyanide | 10–20 g/L | Supplier bath datasheet |
| Working pH | 9.0–9.5 hard gold; 6.5–7.5 soft gold | Supplier bath datasheet |
| Working temperature | 60–70 °C hard gold; 50–65 °C soft gold | Supplier bath datasheet |
| Cathode current density | 2–15 A/dm² rack; 10–30 A/dm² jet | Equipment technical bulletin |
| Coating purity grades | 99.7% minimum gold for Type I; hardness grades per coating classification | ASTM B488-18 |
| Porosity acceptance | Pass at specified thickness over nickel underlay | ASTM B735 |
| Microhardness | 130–200 HK₀.₀₂₅ for hard gold; 60–90 HK₀.₀₂₅ for soft gold | ASTM B578 |
| Solderability | Minimum 95% coverage after aging | IPC J-STD-002D |
| Substance restrictions | Pb, Cd, Hg, Cr(VI) below threshold | RoHS 2011/65/EU |
| Registration and SVHC | Substance registration maintained; SVHC statement on request | REACH 1907/2006 |
Differences from other product forms become significant at bath conversion. AuEL-68 is not a direct substitute for gold sulfite or electroless gold salts. Sulfite gold electrolytes are used for semiconductor bumping and photoresist-defined features because their pH is near neutral and they do not attack positive novolac resists. Cyanide gold salts above pH 10.5 can degrade resist adhesion and etch exposed aluminum pads. Conversely, electroless and immersion gold baths are autocatalytic or displacement systems that deposit thin layers without external current; they do not use potassium dicyanoaurate(I) as the primary consumable. AuEL-68 is also not formulated for barrel decorative plating where large solution volume and frequent activated carbon treatment are common. Compared with liquid gold concentrates, the solid salt offers lower shipping weight per gram of gold and no dilution of bath water, but liquid concentrates reduce the need for dissolution tanks and dust control. In facilities with humidity above 60% RH, the solid salt should be stored in sealed containers and used within 6 months; hygroscopic uptake increases carbonate formation on exposure.
At current densities above 20 A/dm², AuEL-68 baths demand turbulent solution flow across the cathode surface and tight free-cyanide control. The cathode current efficiency of cyanide gold electrodeposition decreases as free cyanide concentration rises because the Au(I) complex is stabilized and hydrogen discharge competes. A free KCN concentration above 20 g/L lowers efficiency and produces pore-forming hydrogen bubbles; below 10 g/L, anode polarization and bath instability are observed. In high-speed jet cells with solution velocities of 1–3 m/s, thickness distribution on connector contacts is typically held within ±10% using insoluble mixed-metal oxide anodes, separate gold replenishment, and anolyte/catholyte separation. The EL grade’s low impurity input is critical because jet cells have smaller electrolyte volume per ampere-hour and contaminants accumulate faster than in rack tanks. Iron contamination above 5 mg/L in the jet bath shifts deposit appearance from full-bright to hazy in low-current-density recesses. Organic additive-free composition avoids carbon co-deposition that would raise contact resistance after aging at 155 °C for 8 h.
For reel-to-reel lines plating stripe widths below 1.0 mm, agitation from submerged jet manifolds is preferred over air agitation to avoid carbonate build-up and spray mist. Anode masks and thief electrodes are adjusted so that the average current density on the contact zone does not exceed 30 A/dm²; higher values may cause burning at leading edges. Filtration through 0.5 µm polypropylene cartridges removes particulates generated by insoluble anodes. Gold replenishment is dosed by ampere-hour counters with a feed factor derived from gravimetric thickness measurements per four-hour production run; the feed factor is cross-checked by X-ray fluorescence of the deposit. When decorative-grade salts are used under the same high-speed conditions, the accumulated organic additives typically require activated carbon treatment after 20–30 Ah/L, while AuEL-68 baths are maintained without carbon treatment because organic contamination is not introduced with the salt.
In thermosonic gold wire bonding, deposits produced from AuEL-68 are specified at 0.5–2.0 µm thickness over 2.5–5.0 µm electroless nickel per IPC-4552. Porosity testing per ASTM B735 uses nitric acid vapor; a coating below 1.0 µm over low-phosphorus nickel may fail porosity acceptance, so 1.5 µm minimum is common for wire-bond pads. The salt is not intended for gold sulfite baths, electroless gold baths, or immersion gold baths. Qualification work should include resist adhesion and metal pad etch tests when converting from cyanide to non-cyanide gold sources. Published data for mixed cyanide/sulfite systems remains limited; specific compatibility tests are required before process release.