| HS Code | 871290 |
| Product Name | Ethanol Electronic/EL Grade |
| Cas Number | 64-17-5 |
| Molecular Formula | C2H5OH |
| Molecular Weight | 46.07 g/mol |
| Purity | ≥99.9% |
| Assay | ≥99.9% (by GC) |
| Water Content | ≤0.05% |
| Appearance | Clear colorless liquid |
| Density 20 C | 0.789 g/cm³ |
| Boiling Point 1 Atm | 78.4°C |
| Flash Point Closed Cup | 13°C |
| Refractive Index 20 C | 1.3611 |
| Electrical Conductivity | ≤0.1 µS/cm |
| Acidity As Ch3cooh | ≤20 ppm |
| Alkalinity As Nh3 | ≤5 ppm |
| Residue After Evaporation | ≤10 ppm |
As an accredited Ethanol Electronic/EL Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Each 1 L bottle contains EL-grade ethanol, packaged in a sealed, contamination-free container for electronic applications. |
| Container Loading (20′ FCL) | Container Loading (20′ FCL): Ethanol Electronic/EL Grade is loaded in sealed drums/IBCs, secured, with proper ventilation and hazardous materials labeling. |
| Shipping | Ethanol Electronic/EL Grade is a high-purity, highly flammable liquid. Ship in UN-certified containers labeled UN1170, Class 3, ensuring grounding and ventilation. Protect from contamination and moisture. Transport per ADR/IMDG regulations, segregate from oxidizing agents, secure upright, and avoid ignition sources during handling. |
| Storage | Store Ethanol Electronic/EL Grade in tightly sealed, dedicated containers to preserve ultra-high purity and prevent moisture or airborne contamination. Keep in a cool, dry, well-ventilated area away from ignition sources, flames, and strong oxidizers. Use nitrogen blanketing when possible. Ensure bonding/grounding during transfers and clearly label all storage vessels. |
| Shelf Life | Shelf life: 3 years from manufacture date if stored unopened in original container, tightly sealed, away from moisture and ignition sources. |
Ethanol Electronic/EL Grade, 200 proof, is controlled for low particle count, low moisture, and low trace metal content in downstream operations where ion migration, particulate contamination, and nonvolatile residue become yield loss mechanisms. The application scope below is limited to electronics manufacturing segments with published qualification data and production-scale process records.
Copper dual damascene post-CMP cleaning in sub-10 nm integration uses split residue-removal and solvent-rinse sequences to reduce silicate dissolution on porous low-k films. Ethanol EL grade is metered into ultrapure water at 5–25 wt% after a buffered ammonium citrate or tetramethylammonium hydroxide pass; this lowers surface tension without adding metal species that would otherwise deposit at the dielectric barrier interface. Compliance in a production qualification lot is anchored to SEMI C18-0301 for trace metals and nonvolatile residue, with moisture by ASTM E203-23 and particle enumeration by a liquid-borne laser counter at ≥0.2 µm; a common acceptance ceiling for total nonvolatile residue is <1.0 mg/L. The cleaning process runs on a 300 mm single-wafer brush/megasonic platform. A PVA roller rotates at 150–350 rpm while the ethanol-water stream flows at 0.5–1.5 L/min; megasonic excitation is held at 0.8–1.2 MHz and 22–35 °C. Contact time is limited to 30–60 s because excess polar solvent exposure on porous ultra-low-k films increases capillary-induced dielectric swelling. After rinsing, the wafer is spin-dried at 1,200–1,800 rpm under filtered nitrogen. Production-scale field data from single-wafer cleaning tools show that recirculation tank operation requires local exhaust interlocks below 25% LFL and that passivation of stainless steel 316L wetted surfaces with nitric or citric acid reduces chromium, nickel, and iron leaching below acid-solvent stability limits. Finished wafers enter logic, DRAM, and 3D NAND lines with copper/low-k interconnects at geometries from 7 nm to 3 nm.
In fine-pitch surface mount assembly, the understencil wipe solvent is not selected only by flux solubility; the acceptable evaporation rate is bounded by the interval between wet wipe and dry wipe in the printer head. Ethanol EL grade is used either neat at 100 wt% or in azeotropic water-ethanol blends at 95.6 wt% ethanol. Addition levels in closed-loop stencil cleaners are typically 70–100 wt% of the active wipe fluid, with the balance being deionized water or a low-vapor-pressure glycol ether for slower tail evaporation. The process standard for electrical acceptability is IPC J-STD-001, while ionic contamination is measured per IPC TM-650 2.3.25; post-print solder paste inspection follows IPC-A-610 for paste volume and shape. In production, the stencil printer wipes the bottom of a laser-cut stainless steel stencil with a fabric roll saturated at 0.4–0.8 mL per wipe; air-atomizing spray nozzles operate at 2.5–4.0 bar, and vacuum extraction holds −60 to −80 kPa. The wet wipe pass is followed by a dry wipe after 0.5–1.5 s to avoid residual solvent deposited into ≤100 µm apertures. Because ethanol flash point is 13 °C, printer cell ventilation must maintain solvent vapor below 25% LFL; high-moisture ethanol and slow-drying blends increase paste slump, bridging, and solder ball formation in type 4 and type 5 solder pastes. Finished assemblies include boards with 0.4 mm pitch BGAs, 01005/0201 chip components, and automotive engine control modules.
Because green sheet residual solvent profile directly governs lamination density and cut-line integrity, ethanol EL grade is added to the dielectric tape casting solvent package at well-defined mass fractions. The slurry formulation is normalized to 100 wt% across the following component windows: BaTiO3 solids 50–60 wt%, ethanol 8–15 wt%, toluene or methyl ethyl ketone 20–30 wt%, polyvinyl butyral binder 3–5 wt%, plasticizer 1–3 wt%, and dispersant 0.3–1.0 wt%. Ethanol adjusts polyvinyl butyral solubility and wetting of submicrometre BaTiO3; it also modulates slurry viscosity to 1,500–4,500 mPa·s at 25 °C for doctor blade casting. Incoming solvent is specified per SEMI C18-0301 because sodium and potassium above 10–20 ppm in the dried tape degrade insulation resistance after sintering; fired dielectric stability is verified in component qualification against AEC-Q200 and IEC 60384 for X7R/X5R temperature classes. Production-scale tape casting uses a vacuum planetary mixer with high-shear dispersion at 1,500–2,500 rpm, followed by de-aeration under 20–50 mbar. The slurry is cast on silicone-coated PET carrier through a doctor blade gap of 30–120 µm; line speed is 0.5–2.0 m/min. Drying uses a multi-zone air flotation oven from 60 °C to 100 °C; residual solvent is held below 3 wt%. At relative humidity above 60%, the ethanol-water azeotrope at 95.6 wt% ethanol absorbs moisture and produces surface skinning. Terminal green sheets are laminated and singulated into MLCCs from 0402 to 0805 and array capacitors.
Flat-panel display manufacturers use EL grade ethanol in the final cleaning module before polyimide alignment layer coating, where residues on indium tin oxide create wetting heterogeneity and mura after liquid crystal filling. The solvent is applied as a neat wipe at 100 wt% or as a dual-stream spray with ultrapure water at 30–70 wt% ethanol; the blend is chosen by contact angle below 10° on ITO and not by polarity alone. Cleanroom compliance is governed by ISO 14644-1:2015 ISO Class 4 particle limits, and solvent purity is verified against SEMI C18-0301 for alkali and transition metals; extractable ionic residue on the glass surface is measured by ion chromatography after a 10 cm² bag extraction, with sodium and potassium each below 1 ng/cm² for advanced oxide TFT backplanes. Published data for this specific configuration is limited in public literature; therefore contact time and blend ratio should be re-qualified for each Gen 8.5 or Gen 10.5 flat-bed cleaner. The process line runs glass through brush cleaning, air knife, and curtain rinse; ethanol dwell time is 20–45 s; air knife slot airflow is 3–7 m/s at 22–25 °C. After drying, the substrate proceeds to polyimide coating within 90 s to avoid re-contamination. Field data from oxide TFT fabs indicate that low-cost technical ethanol grades raise threshold voltage shift after negative bias temperature stress because trace sulfate and chloride migrate into the semiconductor channel. Terminal products include TFT-LCD panels for mobile displays, high-refresh-rate monitors, and OLED shadow masks.
Flip-chip assembly after reflow leaves rosin and organic acid flux residues around solder bumps that must be removed before capillary underfill dispense; otherwise the fillet loses adhesion and moisture ingress delaminates at the die-to-substrate interface. Ethanol EL grade is sprayed in the wash section at 80–100 wt%, with deionized water at 0–20 wt% added only if ion chromatography of the stripped substrate indicates water-soluble acid residue. Compliance is set by IPC J-STD-001 solder joint acceptance and IPC-A-610; low-moisture solvent for packaging is also evaluated under MIL-STD-883 Method 2011 for ionic contamination levels, with a common pass/fail threshold at 1.56 µg NaCl eq/cm² for hermetic-grade packages. In production, a spray-in-air batch cleaner heats the substrate stage to 50–80 °C; wash pressure is 20–40 psi, rinse pressure 30–50 psi, and total cycle time is 8–15 min. After cleaning, the package is dried under inert gas and baked at 100–120 °C for 30–60 min to remove bound water before underfill. Process records show that water content in ethanol above 2 wt% increases underfill voiding at the die edge after thermal cycling −55 °C to +125 °C per JEDEC JESD22-A104. Components include FCBGA processors, WLCSP for mobile, and automotive radar packages.
Ceramic or metal lid sealing in optoelectronic and RF packages requires solvent cleaning that does not leave siloxane, chloride, or alkali metal residues on gold-plated or Kovar seal rings. Ethanol EL grade is used as an immersion solvent at 100 wt% in ultrasonic tanks operating at 40 kHz and 200–400 W per 10 L; parts are immersed for 2–5 min, rinsed in fresh solvent, and dried under filtered nitrogen at 2–4 bar before seam sealing. The compliance baseline is SEMI C18-0301 for solvent metal content; hermeticity is later verified by MIL-STD-883 Method 1014 fine leak and gross leak tests. A low nonvolatile residue specification of <1.0 mg/L is critical because seal-ring reflow at 280–320 °C volatilizes residual organics and causes local voids. In manufacturing, immersion baths are replenished every 8 h or after 500–1,000 parts, whichever occurs first; bath life is determined by particle count drift above 50 particles/mL at ≥0.2 µm. Field failure analysis from hermetic package lines links chloride residue below 1 µg/cm² to consistent gold e-beam weld width; chloride above that threshold causes oxide inclusions and non-wetting. Terminal products include laser diode modules, MEMS inertial sensors, RF filters, and quartz crystal packages.
Competitive Ethanol Electronic/EL Grade prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8615365186327
Email: admin@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Ethanol Electronic/EL Grade is a low-water, low-residue ethyl alcohol (C2H5OH, CAS 64-17-5) prepared for semiconductor cleaning, precision optics, and flat-panel display manufacturing. The designation EL Grade is not a single ASTM-defined category but a supplier-independent electronic-grade classification built around controlled metal cation, anion, and particle loadings. The product is ordered under the designation Ethanol Electronic/EL Grade; supplier model codes vary, but the EL grade definition is consistent in semiconductor procurement specifications. Representative commercial certificates of analysis specify ethanol purity ≥99.9% w/w by GC-FID, water content ≤0.10% w/w by ASTM E203-24, non-volatile residue ≤10 mg/L by ASTM D1353-13(2021), and particle counts ≤100 particles/mL at ≥0.5 µm by a laser light-scattering counter calibrated per ISO 21501-4:2018. The material is filled under nitrogen or argon blanketing into fluoropolymer-lined steel drums or high-density polyethylene containers to prevent atmospheric moisture uptake.
In front-end semiconductor lines, Ethanol Electronic/EL Grade is charged to immersion or spray cleaning modules with PTFE or perfluoroalkoxy wetted parts and recirculated through 0.1 µm cartridge filters. After aqueous or semi-aqueous cleaning sequences, the solvent displaces residual water from high-aspect-ratio trenches and vias before the wafer enters a Marangoni or slow-pull dryer. In microelectromechanical systems and photomask cleaning, the material is used at ambient temperature because a vapor pressure of 5.8 kPa at 20°C supports rapid evaporative drying without aggressive heating. The product is also metered into ultrasonic rinse tanks operating at 40 kHz to 120 kHz for submicron particle removal, provided the equipment is rated for flammable solvents. In printed circuit assembly, the product is applied as a final rinse after flux removal to reduce ionic residues beneath low-standoff components.
Because the solvent is used at the final rinse step, particle shedding from containers and fluid lines is as critical as chemical purity. Electronic/EL Grade ethanol is supplied in containers that have been cleaned and pressure-tested, with wetted surfaces of fluoropolymer, high-density polyethylene, or electropolished 316L stainless steel. The product is tested for particles ≥0.2 µm and ≥0.5 µm using an optical particle counter after agitation; typical acceptance levels are ≤500 particles/mL at ≥0.2 µm and ≤100 particles/mL at ≥0.5 µm. In sub-10 nm node processing, point-of-use filtration at 0.02 µm or 0.05 µm is common regardless of supplier particle data.
Chloride and sulfate residues in post-etch rinses are yield-limiting for aluminum and copper interconnects. Electronic/EL Grade ethanol is specified with chloride ≤0.5 mg/L and sulfate ≤0.5 mg/L by ion chromatography, measured after concentrating the solvent under nitrogen. In production-scale wet benches, rinse baths are monitored by sampling the solvent return line and injecting into a suppressed-conductivity ion chromatograph with a detection limit below 1 µg/L. Batch-to-batch variation in chloride has been observed when the solvent is transferred through non-dedicated stainless steel lines, which can release surface-adsorbed hydrochloric acid from prior chemical campaigns. For this reason, dedicated fluoropolymer distribution lines and pre-conditioned canisters are specified for front-end facilities.
Anion contamination in the final rinse interacts with residual surface moisture to form localized pH shifts after drying. On aluminum bond pads, chloride concentrations above 0.2 µg/cm² can accelerate galvanic corrosion under wire-bond interfaces during humid reliability testing. Process engineers therefore validate the solvent not only by bulk ion chromatography but also by extracting a dried wafer with 50 mL of ultrapure water and analyzing the extract. The solvent is filtered through 0.05 µm absolute PTFE membrane cartridges immediately before dispense to remove particles that may carry adsorbed chloride. The dispensing point is located inside a cleanroom meeting ISO 14644-1:2015 Class 5.
During continuous Marangoni drying operations, the water content of the sump liquid is the primary control variable. Electronic/EL Grade ethanol is maintained at ≤0.10% w/w to keep surface tension near 22.1 mN/m at 20°C. In a nitrogen-carrier Marangoni dryer, ethanol vapor condenses on the wafer surface, and the concentration gradient between condensed ethanol and residual water generates the surface-tension gradient that pulls liquid from recessed features. If water in the bulk solvent rises above 0.20% w/w, the gradient weakens, and residual droplets remain at the bottom of through-silicon via patterns. Sump liquid is titrated by ASTM E203-24 every 4 h during continuous runs.
The drying physics is sensitive to feature geometry. On a 300 mm wafer with sub-50 nm half-pitch structures, capillary forces during evaporation can exceed 10 MPa, so the surface-tension gradient must be maintained above approximately 0.1 mN/m per mm to prevent pattern collapse. Ethanol has a surface tension of 22.1 mN/m at 20°C, whereas water has 72.8 mN/m at 20°C; even a small water fraction therefore reduces the usable gradient. The dryer tank is blanketed with dry nitrogen at a dew point ≤-40°C because ethanol is hygroscopic. Vapor-phase water ingress through open fill ports is controlled by automatic couplers and by maintaining the dispensing room at ISO 14644-1:2015 Class 5 or better.
The use of ethanol in slow-pull dryers differs from Marangoni dryers. In a slow-pull dryer, the wafer is withdrawn at 1 mm/s to 10 mm/s from water or solvent, and the solvent meniscus recedes without vapor condensation. Ethanol is added to the final rinse because its lower surface tension relative to water reduces the contact angle at the feature opening. If the ethanol water content exceeds 0.15%, the contact angle on oxide surfaces increases, and meniscus penetration becomes incomplete in features with aspect ratio greater than 10:1.
For suppliers of electronic chemicals, the distinction among grades is not only ethanol purity but the completeness of the trace impurity profile. ACS reagent ethanol is controlled for general analytical use and may not be filtered to semiconductor particle limits; technical/industrial ethanol may contain denaturants, higher alcohols, ketones, and dissolved ionics that are incompatible with gate oxide integrity. Another difference from solvent-grade ethanol is the absence of denatonium benzoate or other denaturants. Denaturants are high-boiling and can remain after drying as visible residue; for electronic use, non-denatured ethanol is mandated by procurement specifications. Odor and purity measurements are insufficient to control denaturants; GC-MS or LC-MS is used on retained samples to verify the absence of denaturant markers at detection limits below 1 mg/L. Table 1 compares representative specification windows for three commercial grades.
| Grade | Purity (w/w) | Water Content | Non-Volatile Residue | Particle Control | Primary Use |
|---|---|---|---|---|---|
| Electronic/EL Grade | ≥99.9% | ≤0.10% | ≤10 mg/L | Filtered ≤0.1 µm; count specified | Semiconductor rinsing/drying |
| ACS Reagent Grade (absolute) | ≥99.5% | ≤0.20% | ≤5 mg/L | Not specified | Analytical laboratory use |
| Technical/Industrial Grade | ≥95.0% | ≤1.0% | ≤100 mg/L | Not specified | General cleaning |
Compared with isopropyl alcohol, which is the default drying solvent in many fabs, Ethanol Electronic/EL Grade has a lower boiling point of 78.4°C and a higher dielectric constant of 24.5 at 25°C, which can improve solvation of polar ionic contamination. In contrast with methanol-based cleaning fluids, ethanol carries an eight-hour occupational exposure limit of 1000 ppm under OSHA 29 CFR 1910.1000 Table Z-1, whereas methanol is limited to 200 ppm. The product remains a Class 1B flammable liquid under GHS and must be handled in explosion-proof equipment because the closed-cup flash point is 12°C by ASTM D56-21a. The evaporation rate under identical airflow is higher than that of IPA, so wafer surface temperature can drop by 8°C to 10°C in open dryers, requiring heated nitrogen if condensation is not desired.
Adhesion of solder bumps, copper pillars, and redistribution layers is sensitive to monovalent and transition-metal cations left on the die surface. Electronic/EL Grade ethanol limits sodium, potassium, calcium, iron, and copper to ≤10 µg/L each by ICP-MS after solvent evaporation. A single wafer processed in a contaminated rinse tank can show non-uniform wetting and later voiding in underfill around copper pillars. Facilities employing bumping processes often set internal thresholds near 1 × 1011 atoms/cm² by vapor-phase decomposition ICP-MS or total-reflection X-ray fluorescence. Cross-batch ion data are normally available from supplier certificates of analysis; published data for this specific configuration is limited, so each lot is validated before use in gate oxide or bumping operations.
The solvent is not a universal cleaner; it is used after the active cleaning chemistry as a rinsing and drying agent, not as a replacement for formulated strippers or metal-oxide etchants. In high-volume bumping lines, it is dispensed through a 0.05 µm point-of-use filter and heated to 35°C in a fluoropolymer heat exchanger to increase solubility of low-molecular-weight organic residues without destabilizing the solvent. The transfer system uses nitrogen pressure below 0.7 MPa to avoid aerosol generation and static discharge. If the ethanol is allowed to remain in a stagnant line for more than 24 h, the line is drained and purged before processing because water absorption at fittings can raise local water content above the specified limit.
Because the liquid is hygroscopic, containers are kept sealed with nitrogen blanketing and stored at relative humidity below 60%. Do not store with open venting in humid packaging areas; the water specification rises rapidly in ambient air. The product is not compatible with strong oxidizers, concentrated mineral acids, or heated aluminum transfer systems because of decomposition and flammability hazards. Containers must be grounded during dispensing because the solvent has low conductivity and can accumulate static charge.
Procurement specifications normally require the following normative controls.
| Control Area | Standard or Code |
|---|---|
| Cleanroom dispensing environment | ISO 14644-1:2015, Class 5 or better |
| Water content testing | ASTM E203-24 |
| Non-volatile residue testing | ASTM D1353-13(2021) |
| Particle counter calibration | ISO 21501-4:2018 |
| Flash point determination | ASTM D56-21a |
| US transportation classification | UN 1170, Class 3, PG II; 49 CFR 173.120 |
| European classification | CLP Flam. Liq. 2, Eye Irrit. 2 |
| Occupational exposure limit | OSHA 29 CFR 1910.1000 Table Z-1, PEL 1000 ppm |
Diamond-shaped red flammability labels and UN 1170 flammable liquid markings are required on all transport containers. A new lot is released to production only after a solvent blank is run through the wafer cleaning tool and analyzed for residue, water, and particle count. The release protocol is specific to each fab, but the practical acceptance boundary is that no measurable increase in surface metal contamination by TXRF occurs after a 30 min immersion at room temperature.