| HS Code | 486364 |
| Chemical Name | Diethylene Glycol Dimethyl Ether |
| Cas Number | 111-96-6 |
| Molecular Formula | C6H14O3 |
| Molecular Weight | 134.17 g/mol |
| Purity | ≥99.9% (Electronic/EL Grade) |
| Appearance | Clear colorless liquid |
| Water Content | ≤20 ppm |
| Boiling Point | 162 °C |
| Flash Point | 57 °C (closed cup) |
| Density At 20 C | 0.943 g/cm³ |
| Refractive Index At 20 C | 1.4080 |
| Peroxide Content | ≤10 ppm |
| Acidity | ≤0.01 meq/g |
| Residue After Evaporation | ≤5 ppm |
As an accredited Diethylene Glycol Dimethyl Ether Electronic/EL Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Diethylene Glycol Dimethyl Ether Electronic/EL Grade, 1 L, supplied in a clean glass bottle with PTFE-lined cap for purity. |
| Container Loading (20′ FCL) | 20′ FCL: drummed/IBC-packed, EL-grade DGDE loaded, secured, moisture-protected, contamination-free for electronics use. |
| Shipping | Ship Diethylene Glycol Dimethyl Ether (Electronic/EL Grade) as a flammable liquid. Use grounded, sealed containers compatible with ethers, protect from moisture and static. Label per IATA/IMDG/ADR regulations. Store away from oxidizers and ignition sources. Ensure secondary containment and ventilation during transport to prevent vapor accumulation. |
| Storage | Store Diethylene Glycol Dimethyl Ether (Electronic/EL Grade) in a tightly sealed, original container under a dry, inert atmosphere to prevent moisture absorption and contamination. Keep in a cool, well-ventilated area away from heat, ignition sources, and oxidizers. Avoid prolonged light exposure; inspect periodically for peroxide formation. Use clean, dedicated dispensing equipment to maintain high purity. |
| Shelf Life | Shelf life of Diethylene Glycol Dimethyl Ether Electronic/EL Grade is typically two years if kept sealed, dry, and uncontaminated. |
In lithium metal and lithium–sulfur cell prototyping, diglyme functions as a polar, aprotic co-solvent that modifies Li+ solvation shell population toward contact ion pairs and solvent-shared ion pairs, rather than free Li+. This shift has direct consequences for lithium dendrite inhibition and polysulfide dissolution because the multidentate ethylene oxide chain stabilizes Li+ while its low dielectric constant (7.2 at 25 °C) reduces bulk salt dissociation. Typical electrolyte blends contain 0.5–1.5 mol L⁻¹ LiFSI or LiTFSI in diglyme/1,3-dioxolane or diglyme/1,2-dimethoxyethane mixtures at diglyme volume fractions between 30 vol% and 70 vol%. EL-grade purity is critical because residual water above 20 ppm attacks LiFSI and LiTFSI, generates HF and sulfamic acid intermediates, corrodes the lithium metal anode, and raises cell polarization. Proprietary blend preparation takes place in dry rooms with dew point below −40 °C using 316L stainless steel vacuum vessels, planetary blade agitation at 60 rpm, and 0.05 µm PTFE point-of-use filtration. Karl Fischer coulometric titration per ASTM E1064-24 and ICP-MS per ASTM D5673-21 are the minimum lot-release checks. Batch records typically track Na, K, Ca, Fe, Cu below 10 ppb each, chloride below 0.5 ppm, and peroxide below 10 ppm as H₂O₂.
Process limitations are equally defined. Glyme solvents with free peroxide levels above 10 ppm can oxidize electrolyte additives, induce gas evolution, and raise impedance during formation cycles. The high boiling point (162 °C) of diglyme reduces evaporation during vacuum filling but extends drying time after leak testing. Published cycle-life data for specific pouch cell geometries using diglyme-rich electrolytes is limited; therefore cell developers require electrode-level volatility mapping before locking cathode/anode loading. On pilot lines, mixing skids must avoid elastomer seals other than Kalrez or PTFE-encapsulated Viton because diglyme swells NBR and EPDM, releasing leachable oligomers that increase gas evolution at upper cutoff voltage. Wetted parts in transfer lines are specified as electrophoretic stainless steel or high-density fluoropolymer; nickel is avoided due to its catalytic role in solvent oxidation above 4.2 V vs Li/Li+. Explosion-proof electrical classification for the mix room is applied because the solvent has a moderate flash point and peroxide accumulation can lower stability margins during prolonged heating.
| Parameter | Method | EL-grade lot-release control |
|---|---|---|
| Water | ASTM E1064-24, coulometric Karl Fischer | ≤ 50 ppm |
| Na, K, Ca, Fe, Cu | ICP-MS per ASTM D5673-21 | ≤ 10 ppb each |
| Chloride | Ion chromatography with conductivity detection | ≤ 0.5 ppm |
| Particles ≥ 0.5 µm | Optical particle counter in cleanroom per ISO 14644-1:2015 | ≤ 25 counts mL⁻¹ |
| Peroxide | Iodometric titration | ≤ 10 ppm as H₂O₂ |
On single-wafer processing, diglyme-based edge bead remover is dispensed through a 0.1 µm PTFE filter at 23 °C ±1 °C, low-spin 800 rpm, high-spin 2500 rpm. Because vapor pressure is lower than PGMEA, the solvent remains wetted longer at the edge bead meniscus, reducing cracking and redeposition. Metal residues are monitored by VPD-ICP-MS and surface TXRF; transfer of 1 ppb Na from solvent to exposed gate oxide is sufficient to shift mobile ion threshold voltage. For post-etch polymer residue, diglyme is used as co-solvent with N-methylpyrrolidone or dimethylacetamide; etch crust dissolves due polar aprotic swelling, but the process window is narrower than with amine-based strippers because diglyme lacks strong basic hydrolysis capacity. Use only stainless steel or PTFE wetted surfaces; avoid brass, zinc, and aluminum parts because chloride-mediated pitting and metal leaching occur. Waste drain lines require solvent-resistant PVDF or PTFE; standard PVC and PP degrade under sustained contact at elevated temperature.
Deep-UV and KrF photoresist thinning uses diglyme at 2–8 wt% in PGMEA or PGMEA/PGME blends to adjust resist viscosity and slow top-layer skin formation during track dispense. A typical 300 mm coat target is resist kinematic viscosity 1.5–6.0 mm² s⁻¹ at 25 °C, dispense volume 1.0–2.5 mL per wafer, and spin bowl exhaust laminar flow 0.3–0.5 m s⁻¹. Because diglyme boiling point is 162 °C and viscosity is 0.99 mPa·s at 25 °C, it shifts solvent evaporation rate and moves the film-thinning curve; resist film thickness after soft bake at 90 °C for 60 s, measured by ellipsometry, changes approximately 3–6 nm per wt% addition. Filter compatibility is not trivial: high-shear dispense pumps require PTFE or UPE membranes rated at 0.05 µm, while nylon and PVDF membranes may release oligomers or fail pressure differential at 200 kPa. Defect metrology on coated wafers uses laser scattering at 0.1 µm sensitivity; a batch is failed if front-side particle count increases by more than 50 adders at ≥0.2 µm. Process boundaries include photoresist shelf-life change because water above 50 ppm can react with photoacid generators and shift critical dimension after post-exposure bake. Additionally, diglyme must not be introduced into waste streams with acid-catalyzed novolac systems before confirming exotherm and gelation behavior, since trace metal cations and strong acid residues can accelerate polymerization in pot life tests.
In low-ESR aluminum electrolytic capacitor electrolyte screening, EL-grade diglyme has been evaluated as a high-boiling aprotic solvent for quaternary ammonium borate salts, but published data for specific capacitor-grade electrolyte formulations is limited; moisture below 50 ppm and chloride below 1 ppm are the dominant controls because water and halide residues increase leakage current and anode foil polarization.
For shearing, dip-coating, and inkjet deposition of p-type organic semiconductors such as TIPS-pentacene and C₈-BTBT, diglyme is introduced as a high-boiling co-solvent at 10–30 vol% in anisole or toluene to slow nucleation and improve crystal morphology in channel regions. Ink preparation under inert atmosphere uses 0.2 µm PTFE syringe filtration, and inkjet printheads with 20–50 µm nozzle diameter require particle counts no greater than 25 counts mL⁻¹ at ≥0.5 µm. Because ionic residues from solvent impurities migrate to the gate dielectric under bias, the EL-grade requirement is stricter than general reagent: Na, K, Ca, Fe below 10 ppb each, total chloride below 0.5 ppm, and water below 30 ppm. Devices fabricated with these inks on octadecyltrichlorosilane-treated SiO₂ dielectrics are tested under dark nitrogen at drain voltage −10 V; a threshold voltage shift below 1 V over 1000 s is used as a gate bias stability checkpoint. A process incompatibility occurs with ambient air exposure because diglyme slowly forms peroxides; addition of a BHT stabilizer at 50–150 ppm is common but must be validated because BHT residues can shift interfacial trap density in bottom-gate devices. Edge-beading during spin-coating is also more persistent with high-boiling diglyme, so the spin profile must add a 500 rpm relaxation step before the 2000 rpm final dry step.
Because diglyme forms stable dative complexes with alkali and alkaline-earth cations, it is also used in the preparation of metal-organic precursors for thin-film deposition and in sodium–potassium alloy handling inside gloveboxes with oxygen below 1 ppm. A typical reaction setup uses a jacketed glass reactor at −10 °C to 45 °C, a PTFE agitator, pressure relief set at 0.1 MPa, and continuous nitrogen purge. EL-grade solvent is preferred when the final precursor is used for ALD because trace metal contamination from the solvent directly transfers into deposited films; therefore the same lot-release limits of ≤10 ppb for transition metals and ≤20 ppm water are imposed. In synthetic work with organolithium and Grignard reagents, diglyme must be dried over molecular sieves or distilled with sodium/benzophenone, and residual peroxide must be quenched prior to storing waste fractions because unstabilized glyme waste can form shock-sensitive solids. Published data for specific ALD precursor configurations is limited; reactor-scale validation is required for each ligand system. Similarly, the use of diglyme as a complexation medium for metal alkoxide exchanges has a narrow thermal window because prolonged heating above 100 °C may decompose the ether backbone and release methoxyethanol.
Competitive Diethylene Glycol Dimethyl Ether Electronic/EL Grade prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8615365186327
Email: admin@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Diethylene glycol dimethyl ether Electronic/EL Grade (CAS 111-96-6; CH3OCH2CH2OCH2CH2OCH3; molecular weight 134.17 g/mol) is supplied as a high-purity aprotic diether solvent in which water, trace metal cations, chloride, and non-volatile residue are controlled below technical-grade limits. The Electronic/EL Grade designation is the primary model identifier; supplier-specific low-sodium and low-chloride variants are usually differentiated only by certificate-of-analysis limits rather than by separate product formulas. At 20°C and 101.3 kPa, the liquid exhibits a density of 0.943 g/cm³, a dynamic viscosity of 1.06 mPa·s, a normal boiling point of 162°C, and a closed-cup flash point of 57°C. The terminal methoxy groups and interior ethylene oxide units provide aprotic polar solvency with low proton activity, while the same ether structure imposes strict peroxide-management obligations during storage, distillation, and heated processing.
Representative control targets for Electronic/EL Grade diglyme are compiled below from supplier technical bulletins; actual procurement limits are lot-specific.
| Parameter | Test method | Typical Electronic/EL Grade control |
|---|---|---|
| Assay, diglyme | Gas chromatography, area normalization | ≥ 99.5 % |
| Water | ASTM E1064 (coulometric Karl Fischer) | ≤ 50 mg/kg |
| Color | ASTM D1209 | ≤ 10 APHA |
| Acidity | ASTM D1613 | ≤ 0.005 % as acetic acid |
| Peroxide | Iodometric titration, supplier method | ≤ 5 mg/kg as H2O2 |
| Non-volatile residue | Evaporation at 105°C | ≤ 10 mg/kg |
| Chloride | Ion chromatography | ≤ 1 mg/kg |
| Sodium | ICP-MS after acid dilution | ≤ 0.1 mg/kg |
| Potassium | ICP-MS after acid dilution | ≤ 0.1 mg/kg |
| Iron | ICP-MS after acid dilution | ≤ 0.1 mg/kg |
| Copper | ICP-MS after acid dilution | ≤ 0.05 mg/kg |
| Calcium | ICP-MS after acid dilution | ≤ 0.1 mg/kg |
The values above are representative of supplier technical bulletins; no single ISO or ASTM specification applies uniformly to diglyme EL grade. Procurement specifications should be fixed against the supplier lot certificate and controlled transfer methods because moisture and particle levels can shift after container opening.
Technical-grade diglyme is normally specified for industrial synthesis and may carry water levels of 500 mg/kg to 1000 mg/kg, acidity up to 0.02 %, and unspecified trace-metal content. Electronic/EL Grade material narrows these limits because residual mobile ions create surface charge defects in semiconductor devices and because water drives hydrolysis in battery electrolytes. The EL grade is typically purified by multi-stage fractional distillation under reduced pressure with an oxygen-depleted headspace, followed by submicron filtration and packaging under a dry-nitrogen blanket. Distillation reduces non-volatile residue and water, but sodium and potassium can persist when scrubber or column packing contributes alkali metals; final metal removal may require acid-washed glass equipment or dedicated 316L stainless steel receivers.
At reboiler temperatures above 100°C, peroxide accumulation is accelerated in the presence of dissolved oxygen; production units therefore operate below 100°C under vacuum or add a peroxide inhibitor when subsequent application compatibility allows. The difference from technical grade is therefore not a single threshold but a chain of controls: assay ≥ 99.5 %, water ≤ 50 mg/kg by ASTM E1064, color ≤ 10 APHA by ASTM D1209, acidity ≤ 0.005 % by ASTM D1613, and individual metal cations at 0.1 mg/kg or lower by ICP-MS. For wafer-level processes, sodium and potassium are often tightened further to ≤ 0.05 mg/kg because these ions exhibit high mobility in silicon dioxide layers.
In semiconductor photoresist stripping and wafer-cleaning applications, diglyme has been evaluated as an alternative to N-methyl-2-pyrrolidone where the latter is restricted under REACH regulation (EC) No 1907/2006. Replacement is not drop-in: diglyme has a lower closed-cup flash point of 57°C compared with NMP at approximately 95°C, and its normal boiling point of 162°C is lower than NMP at about 202°C. This narrows the safe operating window in heated bath tools; production fixtures typically maintain stripper temperatures at least 10–15°C below the flash point and purge the headspace with nitrogen. Single-wafer spin processors are configured with 316L stainless steel dispense lines, PTFE point-of-use filters at 0.1 µm retention, and exhaust monitoring for the lower explosive limit. Open reservoirs require an inert desiccant breather and on-line Karl Fischer monitoring.
Formulators combining diglyme with alkanolamines should first test for base-catalyzed ether cleavage and peroxide generation. Diglyme is incompatible with concentrated nitric acid, hydrogen peroxide, alkali metals, and strong Lewis acids. A stabilizer-free EL grade is preferred in semiconductor use because residual phenolic antioxidants such as BHT can leave non-volatile residue on wafer surfaces. The solvency of diglyme is strongest for polar acrylate and epoxy-based photoresist residues; published comparative dissolution-rate data for all photoresist generations is limited, so qualification on production-scale residue vehicles is required before substitution.
In lithium-ion and sodium-ion electrolyte development, diglyme is screened as a co-solvent because its two ether oxygen atoms coordinate Li⁺ and Na⁺, reducing ion-pair contact impedance in half-cell testing. Water in the solvent must be held below 20 mg/kg to limit LiPF₆ hydrolysis to HF; this is stricter than the general EL-grade ceiling and is controlled through molecular sieve drying and sealed transfer. Published cycle-life data for full production cells using diglyme-based electrolytes is limited; coin-cell evaluations at 25°C and 45°C are used to establish oxidation stability at 4.2 V versus Li/Li⁺ before scale-up.
At 20°C, the 1.06 mPa·s viscosity permits pressure-driven filtration through 0.1 µm PTFE membranes without excessive differential pressure, but cold-room storage below 10°C raises viscosity and reduces membrane flux. Transfer systems installed on production lines typically use diaphragm or bellows pumps with low-shear bypass loops rather than centrifugal pumps, because high-shear zones can localize heat and accelerate peroxide formation. Elastomeric seals are selected from FFKM or EPDM only after soak testing; natural rubber, nitrile, and some fluorocarbon grades swell or extract into the solvent.
Particle counts after packaging are controlled to ≤ 100 particles/mL at ≥ 0.2 µm under ISO 14644-1 Class 5 conditions. The material should be dispensed through closed lines purged with nitrogen having a dew point below -40°C. Copper and zinc fittings are not used in transfer lines; 316L stainless steel, PTFE, and borosilicate glass are the preferred wetted materials.
Differences among glycol dimethyl ether homologues relevant to EL-grade selection are shown in the following comparative table.
| Solvent | CAS | Molecular weight (g/mol) | Boiling point (°C) | Closed-cup flash point (°C) | Dynamic viscosity at 20°C (mPa·s) |
|---|---|---|---|---|---|
| Monoglyme (1,2-dimethoxyethane) | 110-71-4 | 90.12 | 85 | -2 | 0.46 |
| Diglyme | 111-96-6 | 134.17 | 162 | 57 | 1.06 |
| Triglyme | 112-49-2 | 178.23 | 216 | 111 | 2.0 |
| Tetraglyme | 143-24-8 | 222.28 | 275 | 141 | 3.3 |
Compared with monoglyme, diglyme provides higher flash point and boiling point, reducing evaporative loss and permitting heated bath operation, but at the cost of higher viscosity. Compared with triglyme and tetraglyme, diglyme has lower viscosity and molecular weight, which can improve wetting and residue penetration in high-aspect-ratio structures, but its lower boiling point and flash point require tighter emission controls. Electronic/EL Grade material from different homologues is not interchangeable without qualification because impurity profiles, peroxide behavior, and thermal decomposition residues differ even when assay values are similar.
Containers of Electronic/EL Grade diglyme should be stored in a cool, dry area under inert gas, with lot testing for peroxide before distillation or heated batch processing. Open-vessel exposure at 25°C and 60 % relative humidity can raise water content by more than 20 mg/kg within a single shift; moisture can be restored only by molecular sieve treatment or re-distillation. Transfer lines should be electrically grounded, and the storage area should be arranged for control of peroxide-forming chemicals. Do not use copper or zinc fittings in contact with the solvent; 316L stainless steel, PTFE, and borosilicate glass are the preferred wetted materials.