Products

Carbon Tetrachloride Electronic/EL Grade

    • Product Name: Carbon Tetrachloride Electronic/EL Grade
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: admin@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    Specifications
    HS Code 853307
    Chemical Name Carbon Tetrachloride
    Chemical Formula CCl4
    Cas Number 56-23-5
    Molecular Weight 153.82 g/mol
    Purity ≥99.99% (Electronic/EL Grade)
    Appearance Clear colorless liquid
    Boiling Point 76.7 °C @ 760 mmHg
    Melting Point -22.9 °C
    Density 1.594 g/cm³ @ 25 °C
    Refractive Index 1.4601 @ 20 °C
    Water Content ≤10 ppm
    Assay Gc 99.99% minimum
    Resistivity High purity electronic grade

    As an accredited Carbon Tetrachloride Electronic/EL Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Carbon Tetrachloride Electronic/EL Grade is packaged in 4-liter ultra-clean glass bottles, nitrogen-blanketed, with four bottles per case.
    Container Loading (20′ FCL) 20′ FCL loading of Carbon Tetrachloride Electronic/EL Grade: secure UN-approved drums upright, segregate from oxidizers, ventilate, label, and restrain cargo.
    Shipping Carbon Tetrachloride Electronic/EL Grade must ship in tightly sealed, corrosion-resistant containers, protected from moisture and light. Classified as hazardous and ozone-depleting, it requires proper hazard labeling, UN packaging, ground/sea transport compliance, and handling by trained personnel to prevent leakage, vapor exposure, and environmental contamination.
    Storage Store Carbon Tetrachloride Electronic/EL Grade in a cool, dry, well-ventilated area, away from sunlight, moisture, and incompatible materials. Keep the original container tightly sealed to preserve high purity and prevent contamination. Avoid contact with aluminum, magnesium, and strong oxidizers. Use appropriate labeling and secondary containment to prevent spills and environmental release.
    Shelf Life Shelf life is typically 2 years when stored tightly sealed in a cool, dry, dark area to prevent moisture and light degradation.
    Application of Carbon Tetrachloride Electronic/EL Grade

    A parallel-plate reactive ion etch chamber operating at 13.56 MHz with a liquid-cooled platen is charged with electronic-grade CCl4 at 5–20 sccm, He at 20–50 sccm, and O2 at 0–8 sccm. Chamber pressure is maintained between 50 mTorr and 200 mTorr. The plasma dissociates CCl4 into Cl atoms and carbon-bearing radicals. Carbon fragments deposit on photoresist sidewalls and produce a polymerizing passivation layer that supports anisotropic transfer of the mask pattern into aluminum-rich interconnects. The O2 addition range is narrow. When O2 exceeds 8% of total flow, resist erosion accelerates and critical dimension control deteriorates. Endpoint detection is typically performed by optical emission intensity of AlCl near 261.4 nm. Reported etch rates for Al–Cu metallization on legacy 150 mm parallel-plate tools range from 200–450 nm/min, with resist selectivity of 3:1–6:1 depending on RF power, O2 fraction, and chamber conditioning.

    Gas mixtureTotal flow (sccm)Pressure (mTorr)DC self-bias (−V)Al etch rate (nm/min)Resist selectivity
    CCl₄/He/O₂30–8050–200150–300200–4503:1–6:1
    BCl₃/Cl₂50–10010–50200–400400–8002:1–4:1
    HBr/Cl₂40–905–30250–500300–6005:1–10:1

    Modern semiconductor fabrication has eliminated CCl4 from emissive plasma etch processes because of ozone-depletion potential 1.1 and corrosive hydrolysis byproducts. Its remaining use is confined to process transfer exercises on legacy tools with closed exhaust abatement and to R&D evaluation of older etch libraries. Equipment conversion, leak checking, and exhaust monitoring are governed by SEMI S2 and applicable hazardous waste schedules. Under 40 CFR Part 82, CCl4 is a Class I ozone-depleting substance, and any laboratory or pilot etch use must be reported and controlled. Published data for CCl4-specific etch rates on sub-100 nm features is limited because production fabs shifted to BCl3/Cl2 and HBr/Cl2 chemistries before advanced node qualification.

    How Is CCl₄ Converted to Electronic-Grade CF₄ Without Halide Contamination?

    Anhydrous electronic-grade CCl4 is metered with anhydrous HF into a fixed-bed catalytic fluorination reactor at a molar ratio of 4:1 to 8:1. The catalyst bed is chromium oxyfluoride supported on fluorinated alumina. Reactor temperature is held at 300°C to 500°C under system pressure of 0.5–1.5 MPa. The net reaction CCl4 + 4 HF → CF4 + 4 HCl is exothermic. A molten-salt jacket removes heat and prevents hot spots above 550°C, which would cause catalyst sintering, perfluorinated alkene formation, and yield loss. The crude CF4 stream passes through a water scrubber for HCl removal, a caustic scrubber for residual HF and CO2, and a molecular-sieve dryer. Final cryogenic distillation yields CF4 with purity at or above 99.999 vol%. Typical electronic-grade specs require moisture below 10 ppmv, HCl below 5 ppmv, and total metals below 100 ppbv.

    Fugitive emissions from flange connections and valve packings are monitored with thermal-conductivity halogen leak detectors. Repair thresholds at flange interfaces are set at 1 ppmv. Feedstock transformation is treated differently from emissive use under 40 CFR Part 82, but the facility must still document annual CCl4 consumption, transformation efficiency, and fugitive losses. The resulting CF4 is used downstream in plasma etching of silicon oxide and silicon nitride, where its greenhouse gas impact requires emissions inventory procedures aligned with ISO 14064-1. Published data for exact CCl4 conversion per pass in commercial fluorination trains is limited, as catalyst formulations and recycle ratios are often plant-specific. However, product meeting 99.999 vol% CF4 specification is routinely offered for semiconductor etch applications.

    A vacuum sublimation train for HfCl4 purification begins with chlorination of electronic-grade HfO2 in a quartz tube furnace at 500–900°C under flowing CCl4 vapor. The reaction HfO2 + CCl4 → HfCl4 + CO2 converts the oxide to a sublimate that deposits in a water-cooled cold trap. Crude HfCl4 is resublimed at 317°C under dynamic vacuum of 10⁻³ mbar to reduce zirconium, titanium, and iron residues below 1 ppmw. Similar chlorination routes produce TiCl4 with boiling point 136.4°C, ZrCl4 with sublimation near 331°C, and TaCl5 with melting point 216°C. These high-purity chlorides are precursors for TiN diffusion barriers, HfO₂ high-k gate dielectrics, ZrO₂ capacitor films, and TaN barrier layers in chemical vapor deposition and atomic layer deposition.

    Transfer lines are electrophished 316L stainless steel, passivated with fluorine, and purged with ultra-high-purity argon. Oxygen and moisture are held below 10 ppbv at the point of use. Hydrolysis from moisture ingress converts TiCl4 to TiOCl2 and HCl, creating particle defects in downstream ALD films. Particle counts above 0.2 µm measured by laser particle counter require re-distillation or replacement of the precursor batch. Process control is verified by inductively coupled plasma mass spectrometry after controlled hydrolysis, with acceptance limits set at <1 ppmw for transition metals and <100 ppbw for noble metals. Published data for production-scale CCl4-based metal oxide chlorination is available for TiCl4 and ZrCl4; data for hafnium-specific electronic-grade batches is less widely reported but follows analogous carbothermic chlorination principles.

    When Legacy Closed-Loop Vapor Degreasing Meets ODS Restrictions

    Quartz reticle substrates and BaF₂ infrared windows have historically been cleaned in closed-loop vapor degreasers charged with electronic-grade CCl4. The vapor zone is maintained at 76.7°C, the boiling point of CCl4; the liquid sump is held at 40–55°C to limit thermal shock. Ultrasonic agitation at 40 kHz dislodges particulate matter from recessed fiducials and pellicle frames. Nonvolatile residue is controlled to <1 ppm by gravimetric analysis in accordance with ASTM D1353-13. CCl4 is fully miscible with nonpolar hydrocarbon and silicone oils, but it does not remove water-soluble salts, metal oxides, or rosin flux residues. Those contaminants require a preceding aqueous saponifier or dilute acid cleaning step followed by deionized water rinsing and drying.

    Open-top vapor degreasing with CCl4 is prohibited as an emissive use under 40 CFR Part 82 and most local air district rules. Legacy closed-loop equipment must operate with a freeboard ratio at or above 1.0, refrigerated chiller coils at −20°C, and activated carbon exhaust controls to reduce fugitive losses. Modern photomask cleaning has shifted to UV-ozone, sulfuric acid–hydrogen peroxide mixtures, and dilute SC-1 chemistry. CCl4 is therefore not specified for new photomask lines, and its remaining use is largely limited to controlled analytical reference cleaning or heritage tool qualification. Airborne concentration in workspaces must not exceed the 10 ppm 8-hour TWA established under 29 CFR 1910.1000 Table Z-1.

    A mid-infrared spectrometer fitted with a demountable liquid cell uses carbon tetrachloride as a nonpolar solvent for extracting and identifying hydrocarbon-based residues from electronic assemblies. The solvent exhibits no aliphatic C–H stretching absorption in the 2800–3000 cm⁻¹ region. Strong C–Cl fundamentals appear near 780 cm⁻¹, limiting the useful fingerprint region from 4000 cm⁻¹ down to approximately 900 cm⁻¹. A path length of 0.05–0.1 mm between polished ZnSe or BaF₂ windows is selected to bring extracted residue bands within absorbance units of 0.2–1.0. Qualitative identification follows ASTM E1252-98(2021). Quantitative silicone oil residues are calibrated with gravimetrically prepared standards; the detection limit is matrix-dependent, and published data for specific flux residues is limited.

    All extraction and cell filling is performed in a ducted fume hood. Because CCl4 is hepatotoxic and classified as a potential occupational carcinogen, engineering controls include continuous photoionization detector monitoring near the cell and a minimum face velocity of 0.5 m/s across the hood opening. Waste CCl4 is collected separately from halogenated solvent waste and labeled under applicable hazardous waste rules. The method is not suitable for strongly acidic residues, which can etch ZnSe windows and generate volatile chlorides. In those cases, the residue is first neutralized or extracted into a more polar solvent, and the CCl4 extraction is used only for nonpolar hydrocarbon verification.

    Phosphine-Mediated Chlorination of Alcohol-Bearing OLED and Photoresist Intermediates

    Carbon tetrachloride is consumed as a stoichiometric chlorinating agent in the Appel reaction, where a substrate alcohol is heated with triphenylphosphine in CCl4 under anhydrous conditions. The alcohol oxygen is converted to the corresponding alkyl chloride, while triphenylphosphine is oxidized to triphenylphosphine oxide. The reaction is applied to hydroxyl-terminated monomers and ligands used in OLED emitter preparations and chemically amplified photoresist additives. Reaction temperature is held at 0–25°C during addition and then raised to 40–70°C for completion. CCl4 functions as both reagent and solvent. Moisture is maintained below <50 ppm by use of molecular-sieve-dried glassware and nitrogen purging. Water promotes premature hydrolysis and reduces isolated chlorination yield.

    Purification by silica gel chromatography removes triphenylphosphine oxide. Final assay uses gas chromatography–mass spectrometry with an internal standard. For monomer and ligand products, vacuum distillation at 0.1–1.0 mbar is used to remove unreacted CCl4, residual triphenylphosphine, and halogenated byproducts. Published data for production-scale use of this specific route is limited; batch-to-batch variability in ligand chlorination can shift OLED dopant purity if the alkyl chloride is not distilled. The use of CCl4 for specialty chemical synthesis is permitted as a process agent under the Montreal Protocol only where complete chemical transformation is demonstrated. Residual CCl4 in the isolated product is typically controlled to <100 ppm to satisfy safety specifications and export control requirements.

    Free Quote

    Competitive Carbon Tetrachloride Electronic/EL Grade prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615365186327

    Email: admin@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Supplied under CAS registry number 56-23-5 with molecular formula CCl4, carbon tetrachloride Electronic/EL Grade is a high-purity halogenated liquid with a melting point of −22.9 °C, a density of 1.594 g/cm³ at 20 °C, a normal boiling point of 76.7 °C at 101.325 kPa, a vapour pressure of 12.2 kPa at 20 °C, a dynamic viscosity of 0.969 mPa·s at 20 °C, and a refractive index of 1.4603 at 20 °C. The Electronic/EL Grade designation is not a single universal model; supplier-specific identifiers such as CTC-EL-4N and CTC-EL-5N are applied to products with minimum assays of 99.99% and 99.999% respectively. The product is filled into borosilicate glass ampoules, fluoropolymer-lined drums, or electropolished stainless steel containers with dip tubes and inert-gas pressure transfer. Because the substance is listed under the Montreal Protocol Annex B Group II, procurement, storage, and consumption are limited to permitted closed-system uses. The grade is directed toward controlled electronics and thin-film processes, not general laboratory cleaning or vapour degreasing.

    Specification Matrix for a Representative 4N Electronic/EL Grade

    The table below is a representative supplier envelope for a 4N electronic/EL grade; individual certificates of analysis take precedence because no single international standard defines the grade completely.

    ParameterRepresentative limitTest procedure
    CCl4 assay99.99%ASTM D6806 gas chromatography with flame ionization detection
    Water10 mg/kgASTM E1064 coulometric Karl Fischer titration
    Non-volatile residue5 mg/kgevaporation at 105 °C under nitrogen, gravimetric
    Total metals1 mg/kgICP-MS after sub-boiling evaporation
    Sodium and potassium0.1 mg/kg eachICP-MS
    Chlorinated homologues (CHCl3, C2Cl4)50 mg/kg eachASTM D6806
    Particles ≥0.5 µm25 particles/mLoptical particle counter
    Free chlorine1 mg/kgiodometric titration

    Trace metal analysis is typically performed by inductively coupled plasma mass spectrometry after sub-boiling evaporation of a 100 g sample inside an ISO 14644-1 Class 5 cleanroom to limit environmental cation contamination. The particle count is measured with a light-scattering particle counter after the sealed container has rested for 24 h to allow microbubbles to clear. Results are reported per millilitre for particles at or above 0.5 µm. Published data for a single universal electronic/EL grade specification is limited; each lot must therefore be qualified against the intended etch or deposition process.

    Metallic impurity control is the primary separation from analytical reagent grades because residual iron, copper, chromium, nickel, and sodium can form mobile ions under plasma or thermal exposure. Total metals below 1 mg/kg may still be insufficient for dielectric reliability if sodium and potassium are not separately limited; representative electronic/EL certificates therefore report Na and K at 0.1 mg/kg maximum each. Particle count is an independent variable: low metal content but high particle loading can produce localized chamber deposits. Point-of-use filtration through 0.05 µm fluoropolymer membranes is therefore specified in vapour delivery lines. The chlorinated homologues chloroform and tetrachloroethylene are controlled separately because their vapour pressures differ from CCl4 and shift gas-phase stoichiometry in plasma processes. A representative limit of 50 mg/kg per homologue is common, but the value must be verified against the user's etch selectivity and polymer deposition limits.

    For chlorinated homologues, simple boiling point specifications are rarely adequate because chloroform and tetrachloroethylene form distillation fractions that overlap with CCl4 under some conditions. Gas chromatography with a 60 m × 0.32 mm capillary column and electron capture detection can separate the target homologues at low mg/kg levels. Because CCl4 is itself electron-capturing, the detector linear range must be verified with matrix-matched standards. A representative supplier method uses split injection at 150 °C and a temperature ramp from 40 °C to 240 °C; published validation for electronic/EL grade CCl4 is limited. Supplier certificates often report homologues using ASTM D6806 with flame ionization detection rather than relying on response factors without matrix-matched calibration.

    Technical grade, reagent grade, and electronic/EL grade are separated by impurity mobility rather than main assay alone

    Analytical reagent grade carbon tetrachloride may carry a main assay of 99.5% or greater but is not controlled for particle count, mobile-ion concentration under bias, or clean packaging. Technical grade material may contain sulfur compounds and acidity that leave residues in plasma chambers. Electronic/EL grade packaging is cleaned to low residue levels and sealed under dry nitrogen with a dew point below −70 °C. The comparison below is representative and varies by supplier.

    ParameterElectronic/EL GradeAnalytical Reagent GradeTechnical Grade
    Main assay99.99%99.5%99.0%
    Water10 mg/kg200 mg/kg300 mg/kg
    Total metals1 mg/kg10 mg/kgnot specified
    Particle count ≥0.5 µm25 particles/mLnot specifiednot specified
    Packagingfluoropolymer-lined or electropolished steelglass or steelcarbon steel or plastic
    Application focusplasma etch, CVD feedextraction, trace organic analysischlorinated feedstock, chemical processing

    In plasma etching of aluminium, gallium arsenide, indium phosphide, and certain dielectric hardmask stacks, CCl4 dissociates under 13.56 MHz or 2.45 GHz plasma excitation to generate reactive chlorine atoms and carbon-containing fragments. The carbon-containing species can reduce native metal oxides and moisture-derived oxygen, improving etch initiation on aluminium-copper alloys. The same fragments form chlorocarbon polymer deposits on chamber walls and electrode surfaces; this is an operational boundary rather than a solvent effect. Etch uniformity is more sensitive to moisture and chlorocarbon homologues than to the difference between 99.99% and 99.999% main assay. Published data for high-volume semiconductor use is limited because BCl3/Cl2 mixtures have replaced CCl4 in many aluminium interconnect lines. Where CCl4 remains specified, the electronic/EL grade is usually integrated into closed-source vapour delivery systems with mass flow controllers calibrated for the liquid's vapour pressure curve.

    Closed-source vapour delivery uses the liquid vapour pressure of 12.2 kPa at 20 °C as the primary delivery variable. A mass flow controller calibrated for nitrogen equivalent flow must be corrected for CCl4 gas density and heat capacity; otherwise the delivered mole fraction deviates from the setpoint. The vaporizer is typically held between 40 °C and 60 °C to prevent condensation in downstream gas lines. Published data for this specific configuration is limited and is usually derived from the equipment manufacturer's vapour pressure curve and orifice correction tables.

    What operational boundaries apply to moisture uptake during dispensing?

    Electronic/EL grade carbon tetrachloride is not strongly hygroscopic in the bulk, but moisture ingress during transfer is limited by the low water solubility of 0.8 g/L at 20 °C. Once the container seal is broken, transfer must be performed under nitrogen or helium with a dew point below −70 °C. Exposure to ambient air can raise water content from 10 mg/kg to over 50 mg/kg within minutes at 50% relative humidity due to headspace exchange and condensation on cool surfaces. Transfer lines should be electropolished stainless steel with a surface roughness Ra of 0.25 µm or better. Elastomer seals must be limited to PTFE or perfluoroelastomer; EPDM, nitrile, and silicone absorb chlorocarbons and release particles. The product should not be stored over molecular sieves or alumina because these materials can promote decomposition or generate fines. Pre-filtration through a 0.05 µm fluoropolymer filter is recommended immediately before the vaporizer or mass flow controller inlet.

    Containers are sealed under dry inert gas and each lot is accompanied by a certificate of analysis that reports main assay, water, total metals, mobile ions, chlorinated homologues, and particle count. Retain samples are held for 24 months under nitrogen. Standard pack sizes include 1 L, 4 L, 20 L, and 200 L depending on point-of-use integration. Stainless steel vessels are passivated with nitric acid and dried with hot nitrogen before filling; glass ampoules are sealed under inert gas. The certificate of analysis is not a substitute for in-line verification because contamination can occur during customer-side transfer and dispensing, particularly at fittings and valve seats.

    Under the Montreal Protocol Annex B Group II, carbon tetrachloride remains an ozone-depleting substance; electronic/EL grade does not alter this status. In the European Union, the substance is controlled under Regulation (EC) No 1005/2009 on substances that deplete the ozone layer. Occupational exposure is regulated under OSHA 29 CFR 1910.1000 Table Z-1 as an 8-hour time-weighted average permissible exposure limit of 10 ppm (65 mg/m³) and under ACGIH with a threshold limit value time-weighted average of 5 ppm and a short-term exposure limit of 10 ppm. IARC classifies the substance as Group 2B, possibly carcinogenic to humans. It is incompatible with strong bases, alkali metals, and reactive metal powders, and thermal decomposition can generate hydrogen chloride, chlorine, and phosgene. Closed systems with local exhaust and continuous gas monitoring are mandatory. Electronic/EL grade should not be used as a general cleaning solvent, vapour degreaser, or laboratory extraction solvent except where the controlled impurity envelope and closed-system use are explicitly justified by the process.

    Top