| HS Code | 951353 |
| Density | 1.10 g/cm³ |
| Melt Flow Rate 190 C 2 16 Kg | 2.0 g/10 min |
| Tensile Strength | ≥12.0 MPa |
| Elongation At Break | ≥200% |
| Volume Resistivity At 20 C | ≤100 Ω·cm |
| Volume Resistivity At 90 C | ≤1000 Ω·cm |
| Hot Set Elongation 200 C 15 Min 20 N Cm² | ≤175% |
| Permanent Deformation 200 C 15 Min 20 N Cm² | ≤15% |
| Thermal Aging 135 C 168 H Tensile Strength Change | ≤±25% |
| Thermal Aging 135 C 168 H Elongation Change | ≤±25% |
| Gel Content | ≥80% |
| Moisture Content | ≤0.05% |
| Carbon Black Content | 35±3% |
| Dielectric Constant 50 Hz | ≤3.0 |
| Dissipation Factor 50 Hz | ≤0.01 |
As an accredited Wanma Macromolecule XLPE WMY-4201 SC factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Wanma Macromolecule XLPE WMY-4201 SC is supplied in 25 kg net PP woven bags with PE inner liners, palletized for shipment. |
| Container Loading (20′ FCL) | Container Loading (20′ FCL): One 20′ FCL container loaded with Wanma Macromolecule XLPE WMY-4201 SC, securely packed for ocean shipment. |
| Shipping | Wanma Macromolecule XLPE WMY-4201 SC is typically shipped as a non-hazardous, moisture-sensitive polymer compound in sealed moisture-barrier bags/pallets. Use clean, dry, ventilated transport; protect from rain, heat, sunlight, and contamination. No UN number or dangerous-goods classification normally applies—confirm against the current SDS. |
| Storage | Store Wanma Macromolecule XLPE WMY-4201 SC in a cool, dry, well-ventilated area, away from direct sunlight, heat, sparks, and open flames. Keep original packaging tightly closed and protected from moisture, dust, and contamination. Prevent physical damage, stack securely, follow the SDS and local regulations, and use first-in, first-out. |
| Shelf Life | Wanma Macromolecule XLPE WMY-4201 SC typically has a 12-month shelf life when stored dry, cool, ventilated, and protected from sunlight and moisture. |
In crystalline silicon utility-block PV arrays wired at a system voltage of 1500 V DC, the single-core cable from the string combiner to the central inverter is exposed to long-duration reflected ultraviolet load, conductor temperatures between 70 °C and 90 °C during peak irradiance, and condensing humidity inside cable trays that channel morning dew. WMY-4201 SC is processed as a ready-to-crosslink silane-grafted polyethylene insulation for this service; no additional silane or catalyst masterbatch is added at the converting line. The converter charges the compound at 100 parts by weight as supplied. Clean start-up and edge-trim scrap, stored in sealed foil-lined containers, may be reintroduced at a maximum of 10 wt%; beyond this, the equilibrium moisture content of the reclaim becomes difficult to control and the hot-set test result after sauna curing drifts above the pass threshold required for 1500 V DC operation. Chlorine-free color masterbatch is let down at 2.0–4.0 phr when a black or red outer identification layer is specified, but the masterbatch carrier resin must be a silane-compatible ethylene copolymer because amine-based processing aids interfere with the silanol condensation catalyst. The downstream extrusion line is typically a 90 mm single-screw extruder with L/D 25:1, a barrier screw, compression ratio 2.5:1, and a 120/150/200 mesh screen pack ahead of the crosshead. The melt temperature profile from feed to die is held at 150 °C, 165 °C, 175 °C, and 178 °C; a die-head pressure above 220 bar indicates excessive crosslink initiation in the barrel, and the screw speed or zone-3 setpoint must be reduced before the torque limiter stops the line. The extruded insulation wall of 0.8 mm on tinned copper conductors from 1.5 mm² to 35 mm² is cured in a hot-water bath at 85 °C for 6–8 h or in a 90 °C/90% RH sauna for 4–6 h until hot-set elongation at 200 °C under 0.2 MPa does not exceed 175% elongation under load and permanent set after cooling is ≤ 15% in accordance with IEC 60811-507. Finished constructions are submitted for type-approval testing to EN 50618:2014, IEC 62930:2017, and UL 4703, with the PV1-F and H1Z2Z2-K designations covering the harmonized single-core cable. A processing boundary appears when opened bags are left at ambient RH above 60% for more than 30 min; surface porosity and intermittent spark-test faults occur unless the pellets are re-dried at 75 °C for 2 h in a desiccant dryer with a dew point of −40 °C. The terminal product type is the 1.5 kV DC photovoltaic string cable with crosslinked insulation and halogen-free sheath for solar farm and rooftop array interconnections.
The limitation is not the melt strength of the silane-grafted matrix; it is the interaction among extrudate draw, die swell, and the onset of moisture-induced gelation at the outer surface when a thin wall is drawn onto a solid 1.5 mm² copper conductor. The compound is metered at 100 parts by weight as supplied. A low-dust pigment masterbatch is added at 1.0–3.0 phr, and rework of clean thermoplastic scrap is held below 5 wt% because each pass through the screw adds shear history that shortens the induction time before silanol condensation begins. The processing line uses a 65 mm single-screw extruder with L/D 20:1 to 25:1, a linear low-compression screw, and a pressure-relieved crosshead. The temperature profile is set at 145 °C, 155 °C, 160 °C, and 165 °C; at melt temperatures above 170 °C, premature gel particles accumulate at the die land and produce surface roughness that is often misinterpreted as melt fracture. A vacuum sizing trough with a first-stage pressure of 0.8 bar gauge and a water bath at 85 °C for 6 h are required to achieve a uniform cure gradient through the insulation wall. The applicable construction standard for the fixed-installation product is BS EN 50525-2-51:2011, where the thermosetting insulated single-core non-sheathed cable is tested for a 90 °C continuous conductor temperature, and single-cable flame retardance is verified by IEC 60332-1-2. The terminal finished products are rigid and flexible single-core building wires in cross-sections from 1.5 mm² to 16 mm², installed in conduit or on cable trays in masonry, plaster, and drywall cavities. A field-relevant boundary is that insulation walls below 0.6 mm exhibit lower crosslink density at the conductor interface because the copper acts as a heat sink and slows the moisture diffusion front; the cure schedule must be extended by 2 h when the wall thickness drops below 0.6 mm and the conductor exceeds 6 mm².
For 0.6/1 kV distribution feeders routed from pad-mounted transformers to multi-unit service entrances, the insulation must survive short-circuit conductor temperatures up to 250 °C while maintaining dielectric strength after water ingress. In this application, WMY-4201 SC is processed straight from sealed packaging at 100 parts by weight as supplied. No filler is added because the unfilled silane-crosslinked polyethylene matrix preserves the required insulation resistance and low permittivity; the only permissible addition is a PE-based color masterbatch at 2.0–3.0 phr for red, blue, yellow, green-yellow, or black identification colors in multi-core constructions. The production line for multi-core low-voltage power cable uses a 75 mm single-screw extruder with L/D 25:1 and a compression ratio of 2.0:1 to 2.5:1; the melt pump is set to maintain a constant throughput of 220–300 kg/h depending on conductor size. The temperature profile is 150 °C, 160 °C, 170 °C, and 175 °C, and the hot-water bath is held at 85 °C for 8 h after extrusion. In multi-layer constructions, the inner semi-conductive conductor screen and the outer semi-conductive insulation screen are co-extruded; the interface between the semi-conductive layer and the WMY-4201 SC insulation must be free of moisture because a water film at the interface becomes a site for water-tree propagation under voltage stress. The assembled cable is type-tested to IEC 60502-1 and HD 603 S1 for 0.6/1 kV XLPE-insulated cables, with non-electrical tests including hot-set elongation and shrinkage in accordance with IEC 60811-507. Terminal finished products include N2XY, YJV, XLPE/PVC, and XLPE/PE multi-core power cables in rated cross-sections from 1.5 mm² to 630 mm², installed in cable trenches, cable trays, and direct-burial ducts. The main processing boundary is that the line must not be restarted with residual material that has remained in the hot barrel for more than 10 min; the resulting pre-crosslinked fraction appears as gels after the screen pack and causes spark-test failure at the next insulation thickness checkpoint.
The static-tank moisture-cure environment of an industrial control cable differs from a continuous catenary line because the cable coils are densely packed on reels, and water diffusion into the innermost layers is restricted by the outer cable sheath. WMY-4201 SC is charged at 100 parts by weight as supplied, with a processing aid added only when surface melt fracture appears at thin-wall sections; the processing aid level is capped at 1.0 phr because polar additives can form an interlayer that slows water diffusion and reduces crosslink density near the conductor. The preferred extruder is a 60 mm single-screw machine with L/D 24:1, a Maddock mixing section, and a 100/150/200 mesh screen pack; barrel temperatures are 145 °C, 155 °C, 165 °C, and 170 °C. The insulated core is cooled to below 40 °C before reeling to avoid blocking of adjacent layers. The reel is then placed in a water bath or sauna at 85 °C for 6–8 h; because the reel flange restricts water ingress, the innermost layers require longer cure while the outer layers reach full crosslink density earlier. Dimensional control is verified by sampling the outermost and innermost insulation layers on the same reel and comparing hot-set elongation at 200 °C/0.2 MPa in accordance with IEC 60811-507. The construction must meet UL 1277 for tray cable; when the same compound is used in CE-marked installations, the cable is additionally evaluated against IEC 60092-376 for shipboard control circuits or BS EN 50525-2-51, depending on the voltage class. Terminal products are multi-core shielded and unshielded control cables rated 300/500 V or 0.6/1 kV, with cross-sections from 0.5 mm² to 10 mm², connecting PLC racks, motor starters, instrumentation loops, and HVAC actuators. A production limitation occurs when the outer sheath is applied before the moisture cure is complete; trapped residual moisture migrates to the insulation-sheath interface during service heating and creates interlayer voids that compromise the cable’s combinational electrical and mechanical test performance.
The wet-end environment of a paper mill drive train exposes motor lead insulation to aerosolized process water, oil mist, and periodic gland washdown, which makes surface leakage current a more immediate failure mode than bulk dielectric breakdown. The compound is introduced at 100 parts by weight as supplied. Where a black or blue outer insulation color is required, 2.0–3.0 phr of a carbon-black masterbatch is added; the masterbatch must be dried at 75 °C for 2 h before addition because residual moisture from pigment concentrates generates steam bubbles at the die lip. The extrusion line is typically a 75 mm single-screw extruder with L/D 25:1 and a screen pack of 100/150/200 mesh; the conductor preheater is set to 110 °C to reduce the thermal gradient at the copper-polymer interface. Melt temperatures are held between 155 °C and 170 °C; above 175 °C the silane-grafted chains initiate crosslinking in the barrel and the torque curve becomes unstable. The insulated motor leads are coiled loose and cured in a 90 °C/90% RH sauna for 5–7 h, after which hot-set elongation is measured under 0.2 MPa at 200 °C to confirm that the specimen does not exceed the maximum permitted elongation for the applicable cable standard. Applicable standards include UL 1277 for tray cable and the National Electrical Code requirements for motor supply conductors. The terminal finished products are machine-tool wire and motor lead cables rated 600 V, with crosslinked polyethylene insulation and a tough thermoplastic or crosslinked outer sheath, connecting AC induction motors, servo drives, and branch-circuit disconnects in pulp and paper, metals, and chemical process buildings. The main incompatibility is with mineral-oil-based processing lubricants: if the pellets are contaminated with gear oil from a poorly maintained hopper loader, the oil migrates through the insulation wall during moisture cure and lowers the volume resistivity at 90 °C.
Flexible EV charging cables operate under repeated mechanical cycling, low-temperature bending, and intermittent full-rated current, so the insulation layer must maintain uniform crosslink density without the brittle surface skin that appears when the cure rate is forced too quickly. WMY-4201 SC is dosed at 100 parts by weight as supplied; the only additive is a UV-stabilized color masterbatch at 2.0–3.0 phr, and any reprocessed material is restricted to 5 wt% to avoid gel-seed formation. The extrusion line uses a 70 mm single-screw extruder with L/D 25:1 and a grooved feed section; barrel temperatures are 145 °C, 155 °C, 165 °C, and 168 °C. The crosshead is selected for a draw ratio between 1.8:1 and 2.2:1 to avoid molecular orientation that later relaxes during moisture cure and produces radial cracking. The insulated core is cured in a hot-water bath at 85 °C for at least 8 h for insulation walls up to 1.0 mm; thicker walls require an additional 2 h of cure because water diffusion through the semicrystalline regions of the silane-grafted polyethylene matrix is nonlinear. The cable is type-tested to EN 50620:2017 and IEC 62893-1:2017, with mechanical cycling tests covering bending, torsion, and vehicle-drive-over conditions, followed by insulation resistance and high-voltage spark tests on the finished cable. Terminal product types are single-phase and three-phase EV charging cables rated 300/500 V or 450/750 V with cross-sections from 10 mm² to 35 mm², used in Mode 3 charging stations and portable charging equipment. A critical processing boundary is that the moisture-cure step must be completed before the polyurethane or TPE outer sheath is applied; if the sheath is extruded over partially cured insulation, residual silanol condensation by-products create interlayer bubbles at the sheath-insulation interface during the first high-temperature service cycle.
Competitive Wanma Macromolecule XLPE WMY-4201 SC prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!