| HS Code | 193045 |
| Density | 0.92 g/cm³ |
| Melt Flow Rate | 2.0 g/10 min |
| Tensile Strength | ≥18 MPa |
| Elongation At Break | ≥500% |
| Volume Resistivity | ≥1×10^15 Ω·cm |
| Dielectric Constant | 2.3 |
| Dissipation Factor | ≤0.0005 |
| Dielectric Breakdown Strength | ≥25 kV/mm |
| Gel Content | ≥80% |
| Hot Deformation | ≤50% at 121°C |
| Thermal Aging | 135°C for 168 h |
| Water Absorption | ≤0.05% |
As an accredited Wanma Macromolecule XLPE WMY-4201 SC_A factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Packaged in 25 kg moisture-proof bags, Wanma Macromolecule XLPE WMY-4201 SC_A is supplied on pallets for industrial use. |
| Container Loading (20′ FCL) | 20′ FCL container loaded with Wanma Macromolecule XLPE WMY-4201 SC_A, securely stowed and sealed for standard dry-container transport. |
| Shipping | Wanma Macromolecule XLPE WMY-4201 SC_A is shipped as moisture-proof-packed polymer granules/pellets in sealed bags or drums. Use dry, covered, ventilated transport, avoiding heat, sunlight, moisture, and contamination. Keep containers closed and labeled. Follow the SDS and local regulations; typically classified as non-dangerous goods unless otherwise specified. |
| Storage | Store Wanma Macromolecule XLPE WMY-4201 SC_A in a cool, dry, well-ventilated warehouse, away from direct sunlight, rain, heat, sparks, and open flames. Keep containers tightly closed and undamaged, stacked securely to prevent rupture. Maintain good housekeeping, avoid moisture, and separate from incompatible chemicals. Follow the supplier’s SDS and local regulations for handling, ventilation, and emergency precautions. |
| Shelf Life | Shelf life is typically 12 months from manufacture when stored unopened, dry, cool, and protected from sunlight. |
Downstream processing routes for Wanma Macromolecule XLPE WMY-4201 SC_A are confined to established crosslinkable polyethylene insulation and sheathing applications where silane-induced moisture cure is the dominant crosslinking mechanism. Where the grade is supplied as a two-component Sioplas system, the addition ratios below refer to a separate catalyst masterbatch metered into a silane-grafted base. If the SC_A suffix denotes a pre-compounded single-component variant, the 5.0 wt% catalyst letdown is already internalised and the dosing step is removed; downstream extrusion and curing parameters remain directionally unchanged, but published data for this specific configuration is limited.
For low-voltage distribution cable insulation, the compound is introduced as the unfilled middle layer in a three-layer coextrusion structure between a semi-conductive screen and a strippable outer screen. The relevant installation and construction standards are IEC 60502-1:2021, with Chinese domestic projects typically referencing GB/T 12706.1-2020; where European utilities specify harmonised cables, HD 603 S1:2017 applies. The metered letdown ratio for the catalyst masterbatch is 5.0 wt% into the silane-grafted base, controlled by a gravimetric feeder with a tolerance of ±0.3 wt%. At the extruder, a 90 mm single-screw machine with L/D 25:1 and compression ratio 1.6:1 is set to a barrel profile of 140 °C / 155 °C / 165 °C / 170 °C / 170 °C with head temperature 175 °C. Pressure at the crosshead is maintained below 350 bar; process logs from production-scale lines show that excursions above 380 bar can pre-scorch the silane-grafted phase, producing gel particles that are detected as surface protrusions during inline diameter scanning. After extrusion, the covered conductor enters a cure chamber at 80 °C and 95% RH for 8–12 h depending on wall thickness; a 2.0 mm insulation wall typically reaches a gel content of not less than 70% when tested by xylene extraction according to ASTM D2765-16. The terminal finished product is a 0.6/1 kV low-voltage distribution cable with conductor cross-sections from 1.5 mm² to 630 mm²; before packaging, the cable is subjected to the vertical flame propagation test of IEC 60332-1-2:2015 and a routine spark test at 3.5 kV AC. The compound should not be combined with amine-based stabilizer packages because amine-catalysed condensation can initiate premature crosslinking in the hopper and barrel, producing non-thermoplastic gels that reduce output and require purging with low-melt-index polyethylene.
In photovoltaic cable insulation and sheathing, damp-heat degradation is the controlling failure mode. The relevant product and installation standards are EN 50618:2014 and IEC 62930:2017 for low-smoke zero-halogen PV cables, with UL 4703:2017 invoked for North American installations and TÜV 2 PfG 1169/08.2007 applied under independent certification schemes. Formulation control for this grade uses a 95:5 grafted-base-to-catalyst masterbatch split; when the grade is run as a black outer sheath, a UV-stabilised carbon black masterbatch is added at 2.5–3.0 wt% to meet weathering requirements, while the insulation is left unfilled and unpigmented to avoid dielectric loss at high DC voltage. The extrusion line for a 1.5 kV DC single-core cable typically uses a 65 mm single-screw extruder with L/D 24:1, melt temperatures of 160–185 °C, and line speeds of 40–120 m/min for insulation and 30–80 m/min for sheathing. After extrusion, the cable is cured in a wet chamber at 80 °C and 95% RH for 6–8 h; thin-wall insulation reaches a gel content above 70% by ASTM D2765-16 without excessive post-cure shrinkage. The critical acceptance test is damp heat at 85 °C / 85% RH for 1000 h per EN 50618, with tensile strength and elongation retention not less than 70% of unaged values. A production-scale bottleneck appears when the catalyst masterbatch is overdosed by more than 0.5 wt%; colour shift in the insulation and a measurable increase in dissipation factor at 90 °C occur before the cable reaches the damp-heat chamber. Published data for this specific SC_A designation under EN 50618 damp-heat exposure is limited; the 70% retention threshold is the generic cable acceptance criterion, not a product-specific guarantee. The terminal product class is H1Z2Z2-K or 62930 IEC 131 solar cable rated 1.5 kV DC, with a maximum conductor temperature of 120 °C for XLPE insulation under the relevant TÜV scheme.
| Downstream route | Primary construction standards | Material test methods | Typical cure condition |
|---|---|---|---|
| Low-voltage distribution cable insulation | IEC 60502-1:2021, GB/T 12706.1-2020 | ASTM D2765-16, IEC 60811-501 | 80 °C / 95% RH / 8–12 h |
| Photovoltaic cable insulation and sheath | EN 50618:2014, IEC 62930:2017, UL 4703:2017 | ASTM D2765-16, EN 50618 damp heat | 80 °C / 95% RH / 6–8 h |
| Automotive thin-wall primary wire | ISO 6722-1:2011, SAE J1128, LV 112-1 | ISO 6722-1, ASTM D2765-16 | 70 °C water / 4 h or ambient 14 days |
| Appliance wiring material | UL 758, CSA C22.2 No. 210 | UL 2556, ASTM D2765-16 | 70 °C / 95% RH / 6 h |
| Submersible pump cable | IEC 60502-1:2021, UL 44, CSA C22.2 No. 38 | IEC 60811-501, ASTM D2765-16 | 80 °C water / 12–16 h |
| Building wire | UL 44, UL 62, CSA C22.2 No. 38 | UL 2556, ASTM D2765-16 | 80 °C water / 6–8 h |
At the high-speed thin-wall automotive extrusion line, tooling configuration and melt-pressure stability govern whether 0.25–0.50 mm insulation can be applied without eccentricity drift. The acceptance framework is ISO 6722-1:2011, with SAE J1128 and LV 112-1 applied to North American and German vehicle programs. The catalyst masterbatch is proportioned at 4.8–5.2 wt% via loss-in-weight dosing, and a silicone-based processing aid is added at 0.5–1.0 phr to reduce die drool; pigmented versions use a color concentrate at 2.0 wt%, but only if the concentrate carrier does not contain hygroscopic fillers. A 45 mm single-screw extruder with L/D 24:1 and a low-shear metering section is normally operated at melt temperatures between 150 °C and 165 °C; exceeding 175 °C on long runs leads to visible die-lip accumulation and intermittent diameter spikes that are rejected by the inline laser gauge. The line speed for thin-wall primary wire is typically 200–600 m/min, with an inline spark tester set to 2.5 kV AC. Curing is performed in a water bath at 70 °C for 4 h, or the reel is conditioned at ambient temperature for 14 days when downstream time allows. The terminal product is automotive primary wire in conductor sizes 0.35 mm² to 2.5 mm², rated for Class D temperature class according to ISO 6722-1, and used in engine compartments, door harnesses, and chassis wiring. The main processing incompatibility is the same amine additive class encountered in low-voltage cable: amine stabilizer residues in recycled regrind can trigger premature silanol condensation and raise head pressure within 30 minutes of introducing contaminated material.
Appliance internal wiring requires a narrow window between under-cure and over-cure because a partially condensed insulation can pass initial cold-bend tests but later harden in the presence of retained moisture from the appliance environment. The relevant North American and Canadian construction standards are UL 758 and CSA C22.2 No. 210, with end-product safety assessed under IEC 60335-1:2020; European material restrictions are governed by RoHS 2011/65/EU and REACH Regulation (EC) No 1907/2006. The catalyst masterbatch is held at 5.0 wt%, and antioxidant is added at 0.25 phr to suppress oxidative chain scission during high-temperature appliance service; a processing aid may be let down at 0.3–0.8 wt% if surface finish defects appear on thin walls below 0.38 mm. Extrusion is carried out on a 50 mm single-screw line with L/D 25:1 and a melt temperature of 145–170 °C. After extrusion, the wire is cured at 70 °C and 95% RH for 6 h, then allowed to complete residual condensation at ambient conditions for 7–14 days before final spark testing. The terminal product class includes AWM styles 1015, 1028, and 3173, rated 600 V and 105 °C under UL 758. A line-scale failure mode observed when ambient relative humidity exceeds 60% is surface blistering of uncured pellets at the feed throat; the compound therefore requires pre-drying or closed hopper storage when warehouse RH is above 60%. Published data for this specific SC_A grade in appliance AWM constructions is limited; the processing parameters above reflect established silane-grafted XLPE appliance-wire practice, not a substitute for the supplier’s lot-specific cure curves.
Submersible pump cable insulation operates under continuous water potential, so the specification shifts toward water-tree resistance, wet dielectric stability, and long-term insulation resistance. The applicable power cable construction standard is IEC 60502-1:2021, supplemented by UL 44 and CSA C22.2 No. 38 for North American wet-location cables; flame propagation is tested to IEC 60332-1-2:2015. The letdown ratio is fixed at 95.0 parts silane-grafted base to 5.0 parts catalyst masterbatch by weight, and a hydrolysis-resistant stabiliser is added at 0.4 phr; hygroscopic fillers are excluded from this route because they increase equilibrium water uptake and reduce the volume resistivity measured at 90 °C under IEC 60811-501. The extrusion line uses a 90 mm single-screw machine with L/D 25:1, melt temperature 155–170 °C, and a pressure die suited to heavy-wall insulation of 1.5–2.0 mm. After extrusion, the core is cured in water at 80 °C for 12–16 h, producing a gel content not less than 70% by ASTM D2765-16 throughout the wall; low gel content at the conductor interface is a known cause of insulation pull-back during termination and is checked by slicing the cured wall at 10 mm intervals. The terminal product is a 0.6/1 kV flat or round submersible pump cable in conductor sizes 2.5 mm² to 35 mm², intended for continuous immersion depths and wet-well installations. In long-duration field trials, insulation resistance after 30 days of wet ageing at 60 °C must remain above the cable standard’s minimum; any drop below 109 Ω·m in volume resistivity at 20 °C after immersion indicates the presence of excess silanol or residual moisture and triggers re-cure rather than release.
When the same silane-grafted base is considered for building wire rated 90 °C dry and 75 °C wet, the limiting variable shifts from gel content to long-term thermal oxidative stability and flame test consistency. The governing standards are UL 44 for thermoset-insulated wires and cables, UL 62 for flexible cords and fixture wire, and CSA C22.2 No. 38 for Canadian installations; material ageing is evaluated according to UL 2556, with tensile retention measured after 7 days at 121 °C. The catalyst masterbatch is dosed at 5.0 wt%; the formulation remains unfilled for dielectric integrity, but a flame-retardant outer layer may be applied separately when the construction must pass a vertical wire flame test. Extrusion uses a 60 mm single-screw machine with L/D 25:1 and a crosshead melt temperature of 150–175 °C; after water curing at 80 °C for 6–8 h, the reel is conditioned for 7 days at ambient temperature to complete condensation. The terminal product class is XHHW-2, RHH, and RHW-2 single-conductor building wire, commonly in sizes 14 AWG to 1000 kcmil, rated 600 V. A production-scale limitation appears when the same extruder is cleaned with polar co-polymer purge compounds; residual purge can act as a water-absorption site and produce localised voids during the wet cure. Published data for this specific SC_A designation in XHHW-2 constructions is limited, so the standard’s acceptance criteria are the operative boundary.
Competitive Wanma Macromolecule XLPE WMY-4201 SC_A prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!