Versalis Pharmalene Ms 40 Ph Linear Low Density Polyethylene

Versalis Pharmalene® MS 40 PH Linear Low Density Polyethylene

    • Product Name: Versalis Pharmalene® MS 40 PH Linear Low Density Polyethylene
    • Factroy Site: Yinchuan, Ningxia, China
    • Price Inquiry: sales8@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 784201
    Productname Versalis Pharmalene® MS 40 PH Linear Low Density Polyethylene
    Polymertype Linear Low Density Polyethylene (LLDPE)
    Density 0.940 g/cm³
    Meltflowrate 190c 2 16kg 4.0 g/10 min
    Meltingpoint 126 °C
    Vicatsofteningpoint 110 °C
    Tensilestrengthatyield 18 MPa
    Tensilestrengthatbreak 22 MPa
    Elongationatbreak 700 %
    Flexuralmodulus 700 MPa
    Hardnessshored 55
    Waterabsorption 0.010 %
    Volumeresistivity >1.00E+15 ohm·cm
    Dielectricconstant 2.3
    Dissipationfactor 0.0002
    Oxygenpermeability 2000 cm³·mm/m²·day·atm
    Watervaporpermeability 1.5 g·mm/m²·day
    Thermalconductivity 0.330 W/m·K
    Specificheat 2.30 J/g·°C
    Coefficientoflinearthermalexpansion 0.00015 /°C
    Brittlenesstemperature < -70 °C

    As an accredited Versalis Pharmalene® MS 40 PH Linear Low Density Polyethylene factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Versalis Pharmalene® MS 40 PH Linear Low Density Polyethylene is supplied in 25 kg polyethylene bags, palletized and shrink-wrapped.
    Container Loading (20′ FCL) Container Loading (20′ FCL): Versalis Pharmalene® MS 40 PH Linear Low Density Polyethylene in 25 kg bags, palletized for secure transport.
    Shipping Versalis Pharmalene® MS 40 PH is a non-hazardous, pharmaceutical-grade linear low-density polyethylene. It ships in sealed 25 kg bags, octabins, or bulk trucks under ambient conditions. No ADR/IMDG/IATA dangerous goods classification applies. Protect from moisture, contamination, odors, and direct sunlight; keep packaging intact and dry.
    Storage Store in tightly closed original packaging in a cool, dry, well-ventilated area, away from direct sunlight, heat, ignition sources, and incompatible materials. Protect from moisture, dust, and contamination. Keep bags sealed and pallets off the floor. Maintain temperatures below 40°C and avoid prolonged UV exposure. Observe shelf-life dates and use first-in, first-out stock rotation. Do not stack excessively.
    Shelf Life Shelf life: 2 years from date of manufacture when stored in original unopened packaging, dry, below 40°C, protected from sunlight.
    Application of Versalis Pharmalene® MS 40 PH Linear Low Density Polyethylene

    Why Does Blow-Fill-Seal Tooling Accept a Narrow Molecular Weight LLDPE Where Blown Film Lines Do Not?

    In blow-fill-seal (BFS) manufacture of sterile unit-dose containers, Pharmalene® MS 40 PH linear low density polyethylene is metered through a single-screw extruder with a 18:1 to 24:1 L/D barrier screw at zone temperatures between 170 °C and 220 °C, then formed as a parison, cut, inflated against water-cooled mould plates at 10–15 °C, filled under Grade A air, and sealed within the same mould. The grade’s nominal density of 0.940 g/cm³ per ISO 1183-1 and melt flow rate of 4.0 g/10 min per ISO 1133-1:2022 correlate with reduced hydraulic pressure in the parison head at shear rates typical of 10–20 mm die gaps; this reduces melt fracture and aids reproducible wall distribution. Regulatory alignment for primary contact with aqueous ophthalmic and inhalation preparations is based on Ph. Eur. 3.1.3, USP <661.1>, EU Regulation 10/2011 with an overall migration limit of 10 mg/dm², and elemental impurity risk assessment under ICH Q3D. Extractables screening for BFS ampoules is conducted using USP <1663> and toxicological evaluation per ISO 10993-5:2009 when the fill solution has pH below 2.5 or contains cosolvents above 20% v/v. In monolayer ampoules the resin is processed neat at 100 wt%; in multilayer parison structures it is combined with 20–35 wt% low-density polyethylene to increase melt strength during parison elongation, while amber colorant masterbatch is limited to 1.0–2.0 wt% when light protection is mandated. Downstream terminal products include unit-dose ophthalmic saline, preservative-free bronchodilator inhalation solutions, topical antiseptic ampoules, and low-pH ophthalmic lubricants packaged in 0.25–0.45 mm sidewall containers. On rotary BFS machines, batch-to-batch variation in seal thickness is monitored by ultrasonic wall gauges because sidewall thinning below 0.25 mm at the shoulder is a recurrent process failure that opens a path for microbial ingress. Supplier technical dossiers cover this grade in aseptic BFS, but peer-reviewed data for the exact filling solution class remains limited; melt temperature excursions above 230 °C are controlled because oxidation-related aldehyde formation becomes measurable above that threshold.

    When hydrolysable oral powder fill lines operate above 55% relative humidity, the sealant web must create a dust-tight heat seal through residual active powder without delaminating from the aluminium barrier foil. A three-layer or four-layer coextruded/cast web for primary sachets uses Pharmalene® MS 40 PH as the sealant layer at 70–80 wt% blended with 20–30 wt% LDPE to lower seal initiation temperature; anti-block masterbatch is held below 1.5 wt% because excess silica particles increase seal initiation by 3–5 °C and generate visible haze. The downstream process begins with cast film extrusion at 190–220 °C, followed by adhesive lamination to PET or oriented polyamide and aluminium foil, then vertical form-fill-seal conversion with heated sealing jaws at 135–155 °C, dwell 0.4–0.8 s, and jaw pressure 2–4 bar. Seal strength is validated according to ASTM F88/F88M-21 at a minimum of 1.8 N/15 mm after burst testing; barrier integrity is verified by dye penetrant testing per ASTM F1929-15. Compliance for oral powder primary packaging cites EU Regulation 10/2011 overall migration limit 10 mg/dm², FDA 21 CFR 177.1520, Ph. Eur. 3.1.3, and USP <661.1>. Terminal finished products include unit-dose oral rehydration salts, dry syrup amoxicillin powder sachets, enzyme granule packs, and electrolyte effervescent sticks. The main process conflict is cold seal cracking at the fold; film made from this grade is conditioned at 18–25 °C for a minimum of 24 h before slitting to prevent edge tear propagation.

    Gate Freeze-Off, Screw Recovery and Dimensional Stability in Injection-Moulded Pharmaceutical Closures

    Injection-moulded child-resistant closures, dropper fitments and tamper-evident caps exploit the grade’s 4.0 g/10 min melt flow to fill 16–32 cavity tools with edge gates of 0.6–1.0 mm at barrel profiles from 190 °C to 245 °C, screw back pressure 5–15 bar, and mould surface temperatures 15–30 °C. Formulation addition ratios for pharmaceutical closure compounds typically load Pharmalene® MS 40 PH at 96–99 wt%, with colour masterbatch at 1–2 wt% and polyolefin-compatible processing aid at 0.5–1.5 wt%; slip additive is restricted to 0.2 wt% maximum because higher erucamide migration causes a measurable drop in thread torque retention after 7 days at 40 °C. The downstream manufacturing process is single-screw reciprocating injection moulding with a shut-off nozzle and screw decompression of 2–4 mm to prevent drool at the hot sprue. Gate freeze-off time is controlled by mould temperature and gate thickness; premature gate freeze before packing produces sink marks over the knurled sidewalls, while excessive packing raises residual stress and cracking during repeated child-resistant closure torque tests. Regulatory status is anchored to USP <661.1>, FDA 21 CFR 177.1520, EU Regulation 10/2011, and elemental impurity assessment under ICH Q3D. Terminal finished products include tamper-evident liquid medicine caps, child-resistant closures for solid dose bottles, and dropper fitments for ophthalmic or otic bottles. Dimensional stability is checked by conditioning at 23 ± 2 °C and 50 ± 5% RH for 48 h before measuring cap ovality; out-of-roundness above 0.3 mm is a known lot acceptance limit.

    For ethylene oxide- or gamma-sterilised barrier pouches that enclose pre-filled syringes, surgical kits and wound care dressings, the sealant film is subjected to seal creep after sterilisation and wide warehouse temperature cycling from 5 °C to 35 °C. The sealant web is produced from Pharmalene® MS 40 PH at 85–90 wt% blended with 10–15 wt% LDPE to reduce seal initiation to 120–130 °C; the film is cast at 30–50 μm thickness and laminated to an oriented PET or nylon outer web. Downstream conversion on horizontal form-fill-seal lines uses heated seal bars at 125–145 °C, pressure 3–5 bar, and dwell 0.5–1.0 s to create peelable or welded seals for medical device packaging. Packaging compliance falls under ISO 11607-1:2019 for sterile barrier system design, ISO 11607-2:2019 for process validation, ISO 10993-5:2009 for cytotoxicity of indirect contact materials, and FDA 21 CFR 177.1520 for olefin polymer use. Seal strength after aging is evaluated by ASTM F88/F88M-21 with minimum peel force typically 1.5 N/15 mm, and whole-package integrity is assessed by porous barrier leak testing per ASTM F2096-11. Terminal finished products include header bags, double-pouch systems for orthopaedic implant kits, pre-slit pouch formats for syringe filling lines, and gusseted steam-sterilised wraps for surgical instruments. Process conflict arises when gamma irradiation above 25 kGy shifts seal strength by more than 15%; published data for this specific resin grade under irradiation is limited, and dose mapping is required before release.

    When a Dropper Bottle Crown Needs Environmental Stress Crack Resistance in Lipid-Based Paediatric Formulations

    Extrusion blow moulding lines running squeezable dropper bottles for lipid-containing paediatric oral liquids require parison programming at 180–210 °C, die gaps of 0.9–1.8 mm, and blow pressure 6–8 bar into aluminium moulds held at 12–25 °C. The neck and crown region is a process fault zone because the moving knife induces a vertical weld line; bottle drop testing at 1.2 m onto steel plate is used to expose incomplete parison fusion. Formulation addition ratio for the bottle body is 100 wt% Pharmalene® MS 40 PH when a rigid dropper tip is inserted; if the bottle includes an integral LDPE cap liner or softer squeeze bulb, those sub-components are separate elements and are not blended into the bottle wall. Colour masterbatch is limited to 1.0–1.5 wt%, and calcium stearate or zinc stearate acid scavengers are not combined above 0.1 wt% because residual metallic carboxylates may affect the appearance of transparent walls after steam sterilisation. Compliance for oral and topical pharmaceutical contact is assessed under Ph. Eur. 3.1.3, USP <661.1>, EU Regulation 10/2011, and stress crack resistance is monitored according to ASTM D1693-21, condition B in 10% Igepal CO-630; no peer-reviewed dataset has been published for this exact formulation, so pre-screening against actual fill solutions is recommended. Terminal products include nasal saline dropper bottles, paediatric vitamin D oil dropper bottles, topical antiseptic squeeze packs, and ophthalmic wash bottles with separate dropper inserts. Recurrent processing bottleneck on shuttle blow moulders is blown wall thickness variation between the shoulder and base; operator adjustment of parison programming to maintain 0.45–0.70 mm sidewall distribution is required for lot acceptance.

    For ophthalmic ointments and topical corticosteroid creams packaged in laminated aluminium tubes, the internal sealant layer must resist cracking after repeated flexing while preventing contact between the aluminium barrier and anhydrous or water-in-oil bases. The tube sleeve is produced by coextrusion lamination of Pharmalene® MS 40 PH at 70–85 wt% with 15–30 wt% LDPE as the internal contact layer, a tie coat for aluminium adhesion, and an external printable polyolefin layer; extrusion lamination temperatures range from 240 °C to 280 °C. Tube bodies are welded by high-frequency or hot-air side seam at 140–160 °C, shoulder components are compression moulded separately, and the finished tube is leak-tested after filling at 0.5–0.8 bar internal pressure. Compliance for the internal layer includes Ph. Eur. 3.1.3, USP <661.1>, FDA 21 CFR 177.1520, and EU Regulation 10/2011; extractables analysis for semi-solid dosage forms is conducted per USP <1663> with selected solvents matching the finished formulation. Terminal products include 3.5–10 g ophthalmic antibiotic ointment tubes, topical corticosteroid ointment tubes, wound care petrolatum-based ointment tubes, and rectal cream tubes. Flex cracking of the internal layer around the crimp area is a known defect; lot acceptance includes repeated crimp flexing at 200 cycles with no visual breach of the aluminium barrier. Public utility of supplier data for this exact laminate geometry is incomplete, so crimp design and shoulder geometry are validated per product family rather than extrapolated from bottle or film applications.

    Free Quote

    Competitive Versalis Pharmalene® MS 40 PH Linear Low Density Polyethylene prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Versalis Pharmalene® MS 40 PH is a linear low density polyethylene resin supplied as pellet stock for pharmaceutical and healthcare packaging operations. The designation encodes three separate product attributes: the MS prefix identifies a medium-slip additive package, the numeric field 40 refers to a nominal melt mass-flow rate of 4.0 g/10 min determined at 190 °C under 2.16 kg load according to ISO 1133-1:2022, and the PH suffix indicates a pharmaceutical-oriented stabiliser and additive system selected for controlled extractables and organoleptic neutrality. Nominal density is 0.940 g/cm³ when measured by ISO 1183-1:2019. The material is positioned for thin-wall injection moulding, blow-fill-seal containers, and closure systems where regulatory documentation under USP <661.1>, Ph. Eur. 3.1.3, FDA 21 CFR 177.1520, and EU No 10/2011 is required. Unlike commodity LLDPE of similar density, the pharmaceutical grade restricts carrier resins, slip agents, and antioxidants to substances supported by pharmacopoeial evaluation, lowering the risk of leachable accumulation in aqueous and polar formulations. Published data for the complete quantitative extractables profile in this specific configuration is limited; qualification on the finished drug-contact article remains necessary.

    Processing on conventional polyolefin conversion lines does not require unusual screw geometry. Single-screw extruders with barrier screws of L/D 24:1 to 30:1 and compression ratios from 2.5:1 to 3.5:1 are standard for 4.0 g/10 min LLDPE grades. In thin-wall injection moulding, melt temperatures from 190 °C to 240 °C and mould temperatures from 10 °C to 40 °C provide adequate flow without unnecessarily long cooling time. Clamp force requirements scale with projected area and cavitation; multi-cavity closure tools running this melt-flow range commonly operate between 800 kN and 1800 kN. Shot-weight consistency above 98.5% is feasible when the screw cushion is held at 3 mm to 6 mm and decompression is restricted to 3 mm to 5 mm; larger decompression strokes can produce nozzle drool and gate stringing in high-flow LLDPE. Drying is not normally required from sealed original packaging, but pellet storage at relative humidity above 60% may introduce surface moisture. Pre-drying at 70 °C for 2 h in a hot-air or desiccant dryer restores consistent melt delivery. Melt residence time should remain below 12 min at melt temperatures above 220 °C to limit thermal oxidation and uncontrolled slip-agent migration.

    Rheologically, a 4.0 g/10 min LLDPE at 190 °C typically exhibits shear-thinning behaviour suitable for thin gates. Melt-flow ratio, computed as MFR at 21.6 kg divided by MFR at 2.16 kg, for similar LLDPE grades falls between 25 and 32, indicating moderate shear sensitivity under injection pressures. Published capillary rheometry data for this exact MS 40 PH configuration is limited, and mould-filling simulation should therefore be based on laboratory-generated viscosity curves at 190 °C and 210 °C rather than single-point melt index alone.

    What Processing Boundaries and Sterilisation Limits Apply to Pharmalene MS 40 PH?

    The practical processing window is constrained by two competing risks: low melt temperature reduces knit-line strength in thin closure sections, while high melt temperature accelerates slip-agent degradation and may shift extractables. Melt temperatures below 190 °C increase viscosity and can raise injection pressure above 1200 bar in thin sections; melt temperatures above 250 °C for more than 5 min can damage the medium-slip additive system and alter coefficient of friction after ageing. The softening region of the polymer occurs near its Vicat softening temperature, and steam sterilisation at 121 °C can therefore distort loaded thin-wall containers unless tooling supports the part through the complete cycle. Ethylene oxide sterilisation is more dimensionally suitable because typical exposure temperatures of 38 °C to 60 °C remain below the Vicat range. Gamma irradiation at 25 kGy to 50 kGy under ISO 11137 is generally compatible with LLDPE, although post-irradiation yellowing and changes in surface slip must be evaluated on the finished package. Dose mapping on the formed component is required before release because published data for the exact dose-response of this additive package is limited.

    Blow-fill-seal extrusion imposes a different set of low-shear boundary conditions. Extruder barrel zones for high-flow LLDPE are normally set from 180 °C to 220 °C, with die temperature between 190 °C and 210 °C. Parison formation is favoured by a melt that retains enough melt strength for wall uniformity; excessive medium-slip additive migration to the die lip can generate lip deposits that disrupt parison thickness control. Die-head pressure should be monitored as a production variable. A pressure rise above 240 bar during a continuous run is more commonly associated with screen-pack or lip-deposit accumulation than with resin viscosity drift, and corrective action should isolate these mechanical causes before attributing variation to the polymer.

    Nominal product properties and methods
    PropertyMethodNominal value
    Melt mass-flow rate, 190 °C, 2.16 kgISO 1133-1:20224.0 g/10 min
    Density, 23 °CISO 1183-1:20190.940 g/cm³
    Slip additive levelinternal specificationmedium, controlled
    Stabiliser/additive packagepharmacopoeial evaluationpharmaceutical-oriented

    Thermal data for this density class are useful in establishing cooling and sterilisation limits. DSC peak melting typically falls between 120 °C and 126 °C under ISO 11357-3:2018, while Vicat softening temperature A50 is usually in the 105 °C to 115 °C range under ISO 306:2022. These are class observations rather than product specifications; they explain why steam sterilisation at 121 °C presents dimensional risk. Crystallisation during cooling at 10 °C/min typically peaks near 105 °C, which means mould cooling circuits should maintain surface temperatures below 80 °C at ejection to limit post-mould shrinkage above 1.5% in sections thicker than 2 mm.

    Comparative mechanical and sealing behaviour places MS 40 PH between high-pressure LDPE and metallocene-catalysed LLDPE in several uses. High-pressure LDPE of equivalent melt flow has lower melt tension and less orientation in blow-fill-seal walls, while LLDPE offers higher dart impact and environmental stress crack resistance as measured by ASTM D1709 and ASTM D1693 class methods. The medium-slip additive system reduces closure removal torque relative to unmodified LLDPE but can also reduce heat-seal strength if it blooms excessively before sealing; seal initiation temperature should therefore be revalidated when the closure or film has been stored longer than 30 days at ambient temperature. Compared with metallocene-catalysed LLDPE of similar density, conventional LLDPE grades typically exhibit a broader molecular weight distribution and higher shear sensitivity, which can reduce injection pressure at high shear rates; mLLDPE may offer lower haze and better organoleptics. No direct comparative extractables dataset for MS 40 PH is publicly available. Final qualification should compare leachables against the specific drug product because pH, polarity, and storage temperature change the migration kinetics of the medium-slip additive.

    Compliance Matrix and Drug-Contact Qualification Boundaries

    The resin is supplied with regulatory documentation aligned to the following references, but each reference imposes conditions that are final-article and application-specific. A compliance statement for the base resin does not replace leachables testing on the formed container, closure, or film.

    Compliance and qualification matrix
    ReferenceScopeUse condition
    USP <661.1>Plastic materials of construction for pharmaceutical useQualification on final package configuration
    Ph. Eur. 3.1.3Polyolefins for pharmaceutical containers and closuresMonograph compliance on final article
    FDA 21 CFR 177.1520Olefin polymers for food contactBase resin status subject to use temperature and food type
    EU No 10/2011Plastic materials and articles intended for food contactOverall migration and SML verification on final article
    ISO 10993-1:2018Biological evaluation of medical devicesEnd-device risk assessment, not resin-specific

    Operational boundaries are therefore defined by the combination of resin properties and conversion history. The grade should not be exposed to sustained contact with strong oxidising agents or to non-polar solvents that swell LLDPE; such exposure can increase migration of slip and antioxidant additives. Avoid blending with rework generated from non-pharmaceutical polyolefin grades because minor concentrations of unapproved additives can invalidate the pharmacopoeial position. For multi-layer packaging, tie resins and barrier polymers must themselves meet the same drug-contact requirements; the presence of Pharmalene MS 40 PH in a structure does not confer compliance to the entire laminate. If the resin is processed above 250 °C, or if regrind content exceeds 20% by mass, post-moulding coefficient of friction and extractables should be re-evaluated before the component is released.

    Top