| HS Code | 323564 |
| Density | 0.954 g/cm3 |
| Melt Flow Rate 190 C 2 16 Kg | 0.35 g/10 min |
| Tensile Modulus | 1300 MPa |
| Tensile Stress At Yield | 27 MPa |
| Tensile Strain At Break | >600% |
| Flexural Modulus | 1300 MPa |
| Shore D Hardness | 65 |
| Vicat Softening Temperature | 125 °C |
| Heat Deflection Temperature 0 45 Mpa | 75 °C |
| Charpy Notched Impact Strength At 23 C | 15 kJ/m2 |
| Charpy Notched Impact Strength At 30 C | 8 kJ/m2 |
| Environmental Stress Cracking Resistance | >1000 h |
| Melting Temperature | 133 °C |
| Water Absorption | <0.01% |
As an accredited Versalis HDPE MQ74 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Versalis HDPE MQ74 comes in 25 kg polyethylene bags, with 55 bags per pallet, totaling 1,375 kg per pallet. |
| Container Loading (20′ FCL) | 20′ FCL loading of Versalis HDPE MQ74 high-density polyethylene resin: 25 kg bags, palletized, stretch-wrapped, securely stowed for ocean shipment. |
| Shipping | Versalis HDPE MQ74 is a non-hazardous high-density polyethylene resin. It is typically shipped in 25 kg moisture-resistant bags, palletized and stretch-wrapped, or in bulk trucks/containers with liners. Transport in clean, dry conditions; avoid moisture, direct sunlight, and excessive heat. No special dangerous-goods classification required. |
| Storage | Store Versalis HDPE MQ74 in a cool, dry, well-ventilated area, away from direct sunlight, heat, ignition sources, and strong oxidizing agents. Keep containers closed to prevent moisture and contamination. Avoid prolonged UV exposure. Maintain ambient temperatures, use FIFO rotation, and keep pallets off floors/walls to allow air circulation. Do not stack excessively; protect from physical damage. Follow local regulations. |
| Shelf Life | Recommended shelf life is 12 months when stored in original unopened packaging, cool, dry, away from direct sunlight and heat. |
| Regulatory or test domain | Standard or code | Test method | Controlled variable in MQ74 containers |
|---|---|---|---|
| UN dangerous goods packaging | UN Model Regulations Chapter 6.1; ADR 6.1.5 | Drop, leakproofness, hydraulic, stack | Sidewall thickness ≥ 1.2 mm; pinch-off weld integrity |
| Environmental stress cracking | ASTM D1693-B | 10% Igepal CO-630 at 50 °C | ESCR retention after 25 wt% regrind |
| Melt flow rate | ISO 1133-1:2022 | 190 °C, 21.6 kg | High-load MFR range for parison control |
| Density | ISO 1183-1:2019 | Immersion method | Density specification for rigid container stack strength |
Competitive Versalis HDPE MQ74 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Versalis HDPE MQ74 is an injection moulding grade of high-density polyethylene supplied in pellet form. Public material databases describe the grade as having a melt flow rate in the 7–8 g/10 min range at 190 °C with 2.16 kg load and a density in the 0.956–0.960 g/cm³ range at 23 °C. These values place MQ74 in the medium-flow high-density injection moulding band used for rigid articles such as caps, closures, thin-wall containers, crates, pallets, housewares, and small industrial components. The melt flow rate is determined in accordance with ISO 1133-1; density is measured according to ISO 1183-1. The resin is not formulated for large-part blow moulding, blown film, or rotational moulding, where high melt strength, bubble stability, or long oven stabilisation are controlling.
Design data for MQ74 are generated on injection-moulded specimens rather than compression-moulded sheets because flow orientation and frozen-in stress influence mechanical response. Tensile yield stress and elongation at break are evaluated according to ISO 527-2 or ASTM D638-14. Flexural modulus is determined under ISO 178 or ASTM D790. Notched Izod impact strength is measured by ISO 180/A or ASTM D256; comparisons must be made at identical specimen thickness and notch radius because energy absorption scales with ligament area. Vicat softening temperature is determined according to ISO 306/A120 or ASTM D1525; it is a short-term thermal resistance index and not a continuous-use temperature. Heat deflection temperature at 0.45 MPa is measured according to ISO 75-2/B or ASTM D648. Environmental stress crack resistance is assessed by ASTM D1693, but field performance is strongly influenced by moulded-in stress, processing orientation, and chemical concentration. Published data for this specific configuration is limited when laboratory ESCR values from plaques are applied to thin-wall closures with sharp corners.
| Property | Standard method | Application relevance |
|---|---|---|
| Density | ISO 1183-1 | Controls part mass, shrinkage, and stiffness per unit wall thickness |
| Melt flow rate | ISO 1133-1 | Indicates mould filling behaviour and cycle time class |
| Tensile yield stress | ISO 527-2 / ASTM D638-14 | Sets short-term load-bearing limits for crates and pails |
| Flexural modulus | ISO 178 / ASTM D790 | Predicts resistance to bending deformation in thin-wall panels |
| Notched Izod impact | ISO 180/A / ASTM D256 | Screens toughness at gates, weld lines, and rib roots |
| Vicat softening point | ISO 306/A120 | Short-term thermal resistance for hot-fill packaging checks |
| ESCR | ASTM D1693 | Relevant for detergent, lubricant, and chemical container performance |
Rheological characterisation beyond melt flow rate is performed by capillary rheometry according to ISO 11443. Apparent viscosity is measured at shear rates from 100 s⁻¹ to 10,000 s⁻¹ to build a viscosity curve for mould filling simulation. MQ74 exhibits shear-thinning behaviour: viscosity decreases as shear rate increases, which supports thin-wall filling, while higher viscosity at low shear supports packing and dimensional stability. The crystallisation kinetics of high-density polyethylene are controlled by mould temperature and cooling rate. Rapid cooling at mould temperatures below 20 °C creates smaller spherulites and can improve toughness but increases differential shrinkage. Slow cooling at mould temperatures above 40 °C raises stiffness and reduces warpage but lengthens cycle time.
Blow moulding HDPE grades are typically formulated with melt flow rates below 1 g/10 min at 190 °C/2.16 kg. Their higher molecular weight generates the melt strength needed for parison hang time and bottle pinch-off integrity. MQ74 is positioned in a higher-flow injection moulding band; it has lower zero-shear viscosity, faster stress relaxation, and shorter hold time than those blow moulding grades. These features are advantageous in thin-wall injection moulding but make MQ74 unsuitable for large-part blow moulding because the parison would draw down excessively. Blown film grades, especially high-molecular-weight HDPE, are designed for bubble stability and dart impact resistance under rapid drawing; MQ74 lacks the molecular weight and melt strength for blown film processes. Rotomoulding grades are ground to fine powders, stabilised for long oven cycles at 250–320 °C, and selected for low melt index to avoid pinholes and bubble entrapment during densification. MQ74 is pelletised and not formulated for the oxidative conditions of rotational moulding ovens. Compared with polypropylene injection grades, MQ74 has lower melting temperature and lower stiffness but better low-temperature impact and stress crack resistance in many nonoxidising chemical environments. Compared with linear low-density polyethylene, MQ74 has higher density, higher crystallinity, lower elongation at break, and greater hard-shell rigidity.
Control of temperature, screw speed, and hold pressure determines whether MQ74 produces void-free parts with acceptable weld lines. Barrel set points should follow a rising profile from 180 °C near the feed throat to 240 °C at the nozzle; these set points are adjusted for shot weight and flow length. Mould temperatures between 10 °C and 40 °C are common; the lower end shortens cycle time but increases residual stress, while the upper end improves gloss and knit-line strength at the expense of cooling time. Back pressure in the range 0.5–1.0 MPa improves melt homogenisation and eliminates colour streaks. Hold pressure is set at 50–70% of injection peak pressure and maintained until gate freeze. Screw speed above 150 rpm can induce frictional heating, lower melt viscosity, and promote flash in multi-cavity tools. Hot runner manifolds should not exceed 260 °C; melt residence time above 230 °C should remain below 10 min to limit thermal degradation and mould deposit formation. Pre-drying is not normally required, but condensation on pellets stored at relative humidity above 60% can cause splay and voids. In that condition, pre-drying at 70 °C for 1–2 h in a desiccant dryer is recommended.
Injection moulding machines with clamp force from 80 t to 400 t are used for MQ74 caps, closures, and small containers; crates and pallets may require clamp force from 500 t to 1,000 t depending on projected area. The screw should be a general-purpose polyolefin design with L/D ratio from 18:1 to 24:1 and compression ratio in the range 2.2:1–2.8:1. For parts with wall thickness below 0.8 mm, injection speed should be high enough to fill before the flow front freezes, but excessive speed creates shear heating and may degrade additives. Gate position should place weld lines away from sealing surfaces in caps and closures; for crates and pallets, thick rib intersections require extended hold pressure rather than excessive injection speed to reduce sink marks and warpage. Masterbatch addition at 1–3 wt% should be metered with a low-shear mixing screw to avoid pigment agglomerates and uneven colour distribution.
In multi-cavity closure moulds, cavity-to-cavity flow balance is controlled by runner design rather than by raising melt temperature. Unbalanced runners create differential packing, leading to nonuniform shrinkage and cap fit deviation. Flow length tests using an injection spiral mould are useful for comparing MQ74 lot-to-lot variation, but published data for this specific configuration is limited across different machine sizes and nozzle designs. Mould release from MQ74 parts is generally achieved with standard draft angles of 0.5–1.0° on ribs and 1–2° on sidewalls; lower draft angles require additional release agents, which can interfere with printing or adhesion. For stack moulds, the longer melt path increases pressure loss; hydraulic pressure settings should be verified by pressure transducers inside the cavity rather than by injection unit gauge alone.
Surface splay in MQ74 parts is often caused by moisture on pellet surfaces or by gas entrapment in the melt. Moisture-derived splay appears as silver streaks from the gate and is corrected by predrying at the conditions stated above. Gas-entrapped splay appears as dark streaks near the end of the fill pattern and is corrected by reducing injection speed or adding vents at the last-fill region. Warpage in thin-wall lids is controlled by uniform cooling and by selecting a low mould temperature differential between fixed and moving halves. Sink marks at rib roots are minimised by maintaining hold pressure until gate freeze and by reducing rib thickness to not more than 60% of the adjoining wall thickness. Dimensional variation in closures is reduced by holding melt temperature within a narrow band of ±5 °C around the optimised set point and by controlling mould temperature within ±3 °C. Lot-to-lot melt flow rate variation should be monitored because changes in viscosity alter fill pressure and packing; incoming raw material control should include melt flow rate by ISO 1133-1 and density by ISO 1183-1.
Weld-line strength in coloured MQ74 compounds can be lower than in natural resin because pigments orient parallel to the weld line. For coloured versions, masterbatch carrier resins should be selected from the same polyethylene family to avoid knit-line weakness. The use of nucleating agents is not required in MQ74 but may be added at low levels to increase crystallisation temperature and shorten cycle time; such additions should be validated by differential scanning calorimetry according to ISO 11357-3 to quantify crystallisation temperature shifts. Post-industrial regrind from MQ74 sprues and runners can be blended with virgin pellets at levels up to 20 wt% for many non-critical applications. Repeated extrusion reduces molecular weight and raises melt flow rate; regrind ratio should be controlled by measuring melt flow rate and notched Izod impact after each pass. Colour shift and gel formation should be monitored by screen pack pressure rise and by visual inspection of moulded plaques.
Chemical resistance of MQ74 follows the general behaviour of high-density polyethylene: resistance is good in aqueous, polar, and many nonpolar environments at room temperature, but the resin is not recommended for continuous exposure to strong oxidising agents, aromatic hydrocarbons at elevated temperature, or chlorinated solvents under stress. Stress crack resistance in detergent and lubricant packaging is a function of moulded-in stress, not polymer density alone; local frozen-in stress at gate regions and weld lines can initiate crazing even when the resin passes laboratory ESCR. The grade should not be exposed to sustained load above 60 °C unless supported by application-specific creep data. For food-contact end uses, compliance with EU Regulation 10/2011 and FDA 21 CFR 177.1520 must be confirmed by the converter for the specific additive package and processing conditions. Current supplier certification is authoritative for REACH and RoHS obligations. The use of post-consumer recyclate in MQ74-based parts requires migration and odour testing according to the relevant food-contact regulation if the part is intended for food packaging.