| HS Code | 795115 |
| Density | 0.954 g/cm³ |
| Melt Flow Rate 190 C 2 16 Kg | 0.20 g/10 min |
| Tensile Modulus | 1300 MPa |
| Tensile Stress At Yield | 29 MPa |
| Tensile Strain At Yield | 9 % |
| Tensile Strain At Break | >600 % |
| Flexural Modulus | 1300 MPa |
| Izod Notched Impact Strength At 23 C | 25 kJ/m² |
| Izod Notched Impact Strength At 30 C | 6 kJ/m² |
| Shore D Hardness | 65 |
| Vicat Softening Temperature | 128 °C |
| Brittleness Temperature | < -70 °C |
| Environmental Stress Cracking Resistance 10 Igepal 50 C | >1000 h |
| Water Absorption | <0.01 % |
| Thermal Conductivity | 0.45 W/m·K |
| Coefficient Of Linear Thermal Expansion | 1.2E-4 /°C |
| Dielectric Constant 1 Mhz | 2.3 |
| Volume Resistivity | >1E15 ohm·cm |
As an accredited Versalis HDPE FC 82 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Versalis HDPE FC 82 packaging: 25 kg polyethylene bags, normally stacked on pallets for bulk industrial shipment. |
| Container Loading (20′ FCL) | Versalis HDPE FC 82 loaded in 20′ FCL: 25 kg bags, palletized, shrink-wrapped, labeled, and secured for ocean freight. |
| Shipping | Versalis HDPE FC 82 is shipped as non-hazardous polyethylene pellets in 25 kg bags, octabins, or bulk tankers/containers. Keep dry, cool, ventilated, away from ignition, UV, and contaminants. No special transport classification; follow local regulations and maintain packaging integrity. Store under ambient conditions and protect from moisture and direct sunlight. |
| Storage | Store Versalis HDPE FC 82 in a cool, dry, well-ventilated area away from direct sunlight, heat, ignition sources, and strong oxidizers. Keep original bags or containers closed, clean, and undamaged, on pallets off the floor to prevent moisture and contamination. Avoid prolonged UV exposure. Use first-in, first-out stock rotation; maintain good housekeeping. Do not store near foodstuffs or incompatible materials. |
| Shelf Life | Versalis HDPE FC 82 has a recommended shelf life of 24 months when stored sealed, dry, away from heat and direct sunlight. |
| Standard or Regulation | Designation / Clause | Application to FC 82 Film |
|---|---|---|
| FDA 21 CFR 177.1520(c) 2.1 | Olefin polymers, food contact | Direct food contact for dry and aqueous foods |
| EU Regulation (EU) No 10/2011 | Overall migration limit 10 mg/dm² | EU food contact compliance |
| REACH SVHC | Candidate List threshold 0.1% w/w | Article notification |
| RoHS 2011/65/EU Annex II | Pb 1000 ppm, Hg 1000 ppm, Cd 100 ppm, Cr(VI) 1000 ppm, PBB 1000 ppm, PBDE 1000 ppm | EEE component restrictions |
| ASTM D4976-12a | PE plastics molding and extrusion materials | Material specification |
| ISO 1133-1:2022 | MFR at 190°C/2.16 kg | Melt flow control |
| ISO 1183-1:2019 | Density | Density control |
Competitive Versalis HDPE FC 82 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Versalis HDPE FC 82 is introduced as a high-density polyethylene resin positioned for blown-film extrusion in applications requiring a measurable balance of tensile stiffness, melt strength, and downgauging tolerance. The product model belongs to the film-grade subset of the Versalis HDPE range; its FC prefix indicates a film-oriented molecular architecture and additive package, while the numeric suffix separates it from adjacent film grades having different melt viscosity and mechanical response. Specifications for the grade are conventionally expressed through density, melt mass-flow rate, and ash content. The corresponding test methods are ISO 1183-1:2019 for density, ISO 1133-1:2022 for MFR at 190 °C under 2.16 kg and 5.0 kg loads, and ISO 3451-1 for ash. Because published data for this exact configuration are limited, the current technical data sheet and batch certificate should be treated as the controlling reference for numerical values.
At incoming inspection, the ratio between high-load MFR and low-load MFR is used as an indirect index of molecular weight distribution. For film-grade HDPE, this ratio is usually higher than that of injection-molding grades but may overlap with blow-molding HDPE. The extrudate swell measured on a capillary rheometer at 190 °C and 50 s⁻¹ provides additional differentiation: film-grade HDPE typically shows lower extrudate swell than blow-molding HDPE because parison sag resistance is not required. These rheological checks are not a substitute for the full datasheet; they detect lot-to-lot drift when a converter certifies multiple suppliers against Versalis HDPE FC 82.
Typical end-use categories for this resin class include T-shirt bags, wave-top bags, liners, and light industrial packaging produced on high-stalk or low-stalk blown-film lines. The selection of film structure and thickness is governed by the mechanical performance required in downstream bag-making operations, including tensile yield, tear resistance, and water-vapour transfer rate.
The separation is primarily rheological. Film-grade HDPE is formulated to maintain a stable bubble at high blow-up ratios, which requires high extensional viscosity at draw temperatures but a controlled die swell. Blow-molding HDPE shares the low MFR characteristic but is optimized for sag resistance and parison swell. Injection-molding HDPE is formulated with a higher MFR and a narrower molecular weight distribution to reduce filling pressure and cycle time. Substitution of one HDPE category for another without revalidation alters die pressure, back pressure, melt temperature, and final mechanical properties.
| HDPE category | Typical MFR at 190 °C/2.16 kg (g/10 min) | Typical density (g/cm³) | Critical process requirement |
|---|---|---|---|
| Film-grade HMW-HDPE | 0.15–0.40 | 0.948–0.955 | Bubble stability, low die-lip deposit |
| Blow-molding HMW-HDPE | 0.20–0.50 | 0.949–0.957 | Parison sag resistance, extrudate swell |
| Injection-molding HDPE | 20–60 | 0.950–0.965 | Short cycle time, low injection pressure |
The FC 82 suffix should not be interpreted as a nominal melt index. Product nomenclature can overlap with other suppliers; therefore, any incoming substitution must compare density, MFR, high-load MFR, and the relevant mechanical test values on the same film line.
On blown-film lines equipped with grooved-feed extruders of L/D 25:1 to 30:1 and barrier screws, the feed zone is normally held at 180–190 °C. The compression and metering zones are operated at 210–230 °C. Melt temperature measured after the breaker plate should remain between 200 °C and 220 °C. Extended residence time above 240 °C can generate gel particles and shift the molecular weight distribution, causing off-specification die pressure and film appearance defects.
Spiral mandrel dies with a die gap of 0.8–1.2 mm are preferred. Blow-up ratio is generally maintained between 2.5:1 and 4.0:1, and frost line height is stabilized at 6–10 die diameters. Vertical oscillation beyond ±2 die diameters can increase thickness variation and produce visible gauge bands. Internal bubble cooling, when available, stabilizes the bubble and shifts the frost line downward; without internal bubble cooling, the maximum stable take-off speed is lower and the frost line is more sensitive to room air currents.
The critical shear rate at the die lip limits output. When high-molecular-weight film grades are extruded through narrow die gaps, sharkskin melt fracture can appear at output rates above approximately 1.5 kg/h per centimetre of die circumference, depending on die temperature and resin lot. The corrective sequence begins with raising the die temperature by 5–10 °C, widening the die gap within the specified window, and reducing screw speed. If melt fracture persists, a different resin lot or a processing aid approved for HDPE film extrusion should be evaluated.
Dynamic melt rheology at 190 °C is often measured on a parallel-plate oscillatory rheometer according to ISO 6721-10 with strain amplitude 5% and angular frequency from 0.1 rad/s to 100 rad/s. In film-grade HMW-HDPE, the storage modulus G′ exceeds loss modulus G″ as frequency increases; the crossover point provides a comparative measure of molecular weight distribution breadth. A grade with a broader MWD shows a lower crossover frequency and a more gradual terminal slope, which correlates with enhanced shear thinning during die extrusion and better bubble stability at high output.
Extensional viscosity at draw temperatures is not directly captured by MFR. Melt strength measured on an extensional rheometer or a haul-off strand test at 190 °C provides better differentiation among film-grade lots. High melt strength is desirable to resist bubble rupture during draw-down; however, excessive die swell impairs gauge control. Barrier screws with distributive mixing reduce melt temperature fluctuation, but high-shear dispersive mixing sections can generate local temperature spikes of 5–15 °C, which contribute to gel formation and die-lip deposit.
HDPE is non-hygroscopic, therefore predrying is not normally required. If pellets are stored below dew point or exposed to surface condensation, a dry-air hopper at 60–70 °C for 1–2 h removes surface moisture and prevents bubble defects. Drying must remain below the pellet softening temperature to avoid bridging in the hopper.
For high-speed bag converting, the coefficient of friction and blocking resistance of the finished film are governed by slip and antiblock additives. Slip additives reduce coefficient of friction by migrating to the film surface; the coefficient of friction is measured according to ASTM D1894, and blocking by ASTM D3354. If the base grade does not contain the required surface additives, a masterbatch is introduced at the extruder hopper. Dispersive quality of the additive masterbatch must be monitored by film optical inspection and coefficient of friction mapping across the layflat width.
During film property evaluation, tensile yield and elongation are measured according to ISO 527-3 or ASTM D882, dart drop impact by ISO 7765-1 Method A or ASTM D1709 Method A, and Elmendorf tear resistance by ISO 6383-2 or ASTM D1922. HDPE film grades typically display higher tensile modulus and lower water-vapour transmission than linear low-density polyethylene of equivalent thickness, but lower dart impact and lower tear resistance. In downgauged structures, machine-direction tear under ISO 6383-2 can become the limiting property because of orientation effects in the blown bubble. Water-vapour transmission rate is assessed by ISO 15106-3 or ASTM F1249, and oxygen transmission rate by ASTM D3985. The exact values for Versalis HDPE FC 82 must be drawn from the current datasheet; published data for this specific configuration is limited, and lot-to-lot variability should be accounted for in specification agreements.
Relative to low-density polyethylene, HDPE FC 82 is expected to show higher density, greater tensile yield stress, and lower water-vapour transmission rate, but lower dart drop impact and a more translucent film appearance. Relative to linear low-density polyethylene, the HDPE film shows higher modulus and lower elongation at break. These differences are measurable under ISO 527-3, ISO 7765-1, and ISO 15106-3. Product selections therefore begin with the required material handling performance, not with a simple resin substitution.
At thickness below 12 µm, the operating window narrows. Bubble instability becomes more sensitive to melt temperature fluctuation; a variation of ±3 °C at the die can shift the frost line and produce gauge bands. Internal bubble cooling stabilizes the bubble and improves heat removal. Without internal bubble cooling, maximum stable take-off speed is reduced and gauge variation may exceed ±5%.
Die-lip deposit formation on production lines can require cleaning every 6–12 h when the resin contains low-molecular-weight species. A polyolefin purge compound or manual die-face cleaning is used. Repeated mechanical die-lip scraping may damage chrome plating and should be minimized; ceramic-coated lips are preferred when long campaigns are planned.
Because blown HDPE film displays anisotropic orientation, tear resistance in the machine direction is frequently the first property to fall below specification during downgauging. Converters compensate by blending with 10–20 wt% linear low-density polyethylene or by adjusting blow-up ratio. Such changes also modify tensile yield and water-vapour transmission and therefore require revalidation under the relevant mechanical and food-contact standards.
For food-contact applications, HDPE resins intended for packaging must be supported by a supplier statement referencing EU Regulation No 10/2011 and FDA 21 CFR 177.1520. The food-contact status is formulation-dependent; converters must verify overall migration limits and specific migration limits for additives by the methods in EN 1186-1 and EN 13130-1. RoHS Directive 2011/65/EU applies to electrical and electronic equipment packaging only in limited contexts, but heavy-metal restrictions are commonly assessed by EN IEC 62321. REACH compliance is documented through the safety data sheet and extended SDS, including SVHC content below 0.1 wt% per article.
| Regulation or standard | Scope | Typical test method / clause |
|---|---|---|
| EU Regulation No 10/2011 | Plastic materials and articles intended for food contact | Overall migration by EN 1186-1; specific migration by EN 13130-1 |
| FDA 21 CFR 177.1520 | Olefin polymers in food contact | End-use compliance statement; migration testing under relevant food simulants |
| REACH Regulation (EC) No 1907/2006 | Registration, evaluation, authorisation, and restriction of chemicals | SDS and extended SDS; SVHC concentration below 0.1 wt% |
| RoHS Directive 2011/65/EU | Restriction of hazardous substances in electrical and electronic equipment | Heavy-metal screening by EN IEC 62321 where applicable |
On high-output multi-layer blown-film lines, Versalis HDPE FC 82 is typically used as the stiffening substrate layer in structures that combine HDPE with linear low-density polyethylene or low-density polyethylene seal layers. The melt temperature of the HDPE layer is held within the range 200–220 °C, and the die gap is set according to the most shear-sensitive layer. Differences from LLDPE-rich structures appear in tensile modulus and water-vapour barrier: HDPE increases modulus and reduces moisture vapour transmission rate but lowers dart drop impact. Converters using automatic gauge control report that the HDPE layer requires more frequent thickness profile correction than LLDPE because of its higher melt elasticity at low shear. Incompatibility with amine-based additives should be avoided if prolonged high-temperature residence is anticipated; certain amine-based stabilisers can contribute to discolouration and deposition on die lips. Processing aid compatibility should be confirmed with the supplier before trial. Published data for this specific configuration is limited, and processing trials on the target line are required to establish the final operating window.