Versalis HDPE COM75HF1 is a high-density polyethylene copolymer supplied in pellet form. The grade is reported with a melt mass-flow rate of 7.5 g/10 min when tested at 190 °C under a 2.16 kg load according to ISO 1133-1:2022 and a density of 0.953 g/cm³ according to ISO 1183-1:2019. These two values define the primary processing envelope: the MFR places the material in the medium-flow injection moulding band, while the density places it in the high-density polyethylene class rather than medium-density or linear-low-density ranges. The product is intended for rigid injection-moulded articles such as thin-walled food containers, caps, closures, and reusable crates where a combination of flow length, impact resistance at low temperature, and adequate stiffness is required. In comparison with fractional-melt blow moulding grades, the higher MFR reduces injection pressures and improves thin-wall filling but lowers melt strength and environmental stress crack resistance.
How Is the Melt Flow Rate Specified and What Does It Control?
The designation places the grade within a medium-flow injection moulding band. The reported 7.5 g/10 min melt mass-flow rate is the key processing parameter because it correlates with apparent viscosity under injection shear rates. At a shear rate of 1,000 s⁻¹ and 220 °C, the apparent viscosity is estimated to fall in the 100–200 Pa·s range, though capillary rheometry is required for precise simulation input because MFR is a single-point low-shear measurement. The density of 0.953 g/cm³ lies within the band associated with high-density polyethylene copolymers used for thin-wall packaging rather than the 0.958–0.965 g/cm³ homopolymer band used for bottle caps requiring higher top-load stiffness. The combination is achieved through controlled ethylene–α-olefin copolymerisation, which introduces short-chain branches in a concentration sufficient to lower crystallinity but not enough to enter the medium-density category.
Which Test Methods Define the Property Set for COM75HF1?
The technical data sheet is organised around destructive and thermal tests that characterise short-term mechanical behaviour. Tensile yield stress is determined at 50 mm/min using ISO 527-2:2012 on type 1A specimens. Flexural modulus is measured by ISO 178:2019 at 2 mm/min on 80 mm × 10 mm × 4 mm bars. Notched Charpy impact is tested at 23 °C using ISO 179-1:2010 on type 1 edgewise specimens. Vicat softening temperature is recorded at 50 °C/h under a 10 N load following ISO 306:2022. Shore D hardness is measured with ISO 868:2003 after conditioning at 23 °C and 50 % relative humidity for 48 h.
| Property | Test method | Typical value |
|---|---|---|
| Melt mass-flow rate | ISO 1133-1:2022 | 7.5 g/10 min |
| Density | ISO 1183-1:2019 | 0.953 g/cm³ |
| Tensile stress at yield | ISO 527-2:2012 | 26 MPa |
| Elongation at break | ISO 527-2:2012 | >500 % |
| Flexural modulus | ISO 178:2019 | 1,100 MPa |
| Charpy notched impact at 23 °C | ISO 179-1:2010 | 6 kJ/m² |
| Vicat softening temperature | ISO 306:2022 | 124 °C |
| Shore D hardness | ISO 868:2003 | 63 |
The tensile yield stress of 26 MPa and flexural modulus of 1,100 MPa are characteristic of a high-density ethylene–α-olefin copolymer at this density and MFR. The relatively low modulus compared with a 0.960 g/cm³ homopolymer reflects the thinner lamellae and lower crystalline fraction produced by the comonomer. In a thin-wall container with a nominal wall thickness of 0.6 mm, the combination of 7.5 g/10 min MFR and 0.953 g/cm³ density permits filling of multicavity tools at moderate hydraulic pressures; however, the same crystalline structure reduces resistance to creep under constant top-load relative to higher-density injection moulding grades.
Processing Conditions That Govern Shrinkage and Weld-Line Integrity
Processing on a reciprocating-screw injection moulding machine with an L/D ratio of 20:1 to 25:1 and a compression ratio of 2.5:1 to 3.0:1 is recommended for this melt-flow band. A flat-to-slightly-rising barrel programme from 200 °C to 240 °C is suitable for most mould geometries. The mould temperature should be maintained at 10 °C to 40 °C to shorten cooling time and reduce cycle time in thin-wall tools; higher mould temperatures up to 60 °C may be required for closures with thick hinge bosses to reduce internal stress. Drying is usually unnecessary when surface moisture is below 0.1 %; above this threshold, a desiccant dryer at 80 °C for 2–4 h prevents surface splay. At melt temperatures above 280 °C, residence time should be limited to 10 min because oxidative chain scission reduces molecular weight and shifts the MFR upward. Nozzle decompression should be kept below 5 mm because the low melt strength of this grade promotes stringing and drool at the nozzle tip.
Linear mould shrinkage for HDPE with this density and MFR typically falls in the 1.5–2.5 % range parallel to flow and 1.0–2.0 % perpendicular to flow when measured by ISO 294-4:2018. Shrinkage is not isotropic; gate location, packing pressure, and cooling time alter both the magnitude and the direction of post-mould distortion. Weld-line strength is sensitive to melt temperature and injection velocity. At melt temperatures below 220 °C, weld-line elongation can fall below 50 % of the base-resin value, especially in grades with narrow molecular weight distribution. To maintain weld-line strength in multi-gate tools, the nozzle temperature should remain above 230 °C, and injection velocity should be adjusted to produce a melt-front temperature at the converging region above 200 °C. Gas-counterpressure or sequential valve-gate control can be used where weld lines cross load-bearing regions.
When COM75HF1 Replaces a Fractional-Melt Blow Moulding Grade
Substitution of COM75HF1 for a fractional-melt blow moulding HDPE is generally limited to injection-moulded articles and is not recommended for extrusion blow moulding because the 7.5 g/10 min melt flow rate provides insufficient parison stability. In extrusion blow moulding, high-molecular-weight HDPE with MFR between 0.3 g/10 min and 1.2 g/10 min is used to resist sag during parison formation and to maintain die swell. The COM75HF1 resin would produce a short parison, lower die swell, and higher variability in wall thickness on tools designed for high-molecular-weight grades. In injection moulding, however, the higher MFR of COM75HF1 reduces filling pressure and allows thinner wall sections than a 0.3 g/10 min grade; the trade-off is lower environmental stress cracking resistance and lower top-load strength at equal density.
| Polymer family | Melt mass-flow rate | Density | Characteristic processing consequence |
|---|---|---|---|
| COM75HF1 medium-flow injection HDPE | 7.5 g/10 min | 0.953 g/cm³ | Balanced injection filling and impact; not intended for extrusion blow moulding |
| Fractional-melt blow moulding HDPE | 0.3–1.2 g/10 min | 0.948–0.955 g/cm³ | High parison stability and die swell; unsuitable for thin-wall injection filling |
| High-flow injection HDPE | 20–45 g/10 min | 0.953–0.960 g/cm³ | Very thin-wall filling; lower impact and ESCR |
| Rotomoulding HDPE | 3–6 g/10 min | 0.940–0.945 g/cm³ | Requires powder grinding and long sintering window |
Compared with high-flow injection moulding HDPE grades with MFR above 20 g/10 min, COM75HF1 retains higher melt strength and better impact performance but requires higher injection pressure and longer packing time. It is therefore used where ESCR and drop impact are more important than filling of extremely thin sections below 0.4 mm. Compared with a 0.953 g/cm³ homopolymer with similar MFR, the copolymer structure improves stress crack resistance but lowers stiffness and Vicat softening temperature by approximately 2–4 °C.
Regulatory Status and Food-Contact Constraints
Versalis HDPE COM75HF1 is suitable for food-contact applications when the finished article meets FDA 21 CFR 177.1520 for olefin polymers. In the European Union, compliance is assessed under Regulation (EU) No 10/2011 as amended, including overall migration testing according to the EN 1186 series and specific migration testing according to EN 13130 methods where applicable. The grade is intended for use at room temperature or hot-fill conditions depending on the additive package and wall thickness, but not for retort or sterilisation above 100 °C unless the final article has been validated. Users should confirm the latest safety data sheet and food-contact declaration from the supplier because zinc stearate, antioxidants, and neutralisers may vary among production campaigns. The polymer itself is not classified under REACH as a substance of very high concern, and the product may be assessed for RoHS Directive 2011/65/EU compliance at the finished-article level. The material is not intended for medical device implantation or for long-term contact with strong oxidising acids.
In closure applications, the grade is screened for environmental stress cracking resistance by ASTM D1693-15 using 100 % Igepal CO-630 at 50 °C; the lower molecular weight relative to blow moulding grades reduces the time to failure under constant strain, so the selection of COM75HF1 should be validated with the specific closure design and torque retention test. For thin-wall food containers, instrumented puncture impact at 0 °C and 5 °C by ISO 6603-2:2023 is used to compare the product against higher-density injection moulding grades. Published data for this specific configuration is limited; therefore, production-scale trials on a 150 t to 250 t injection machine with a hot-runner multicavity tool remain necessary to establish the processing window for a given article.