| HS Code | 892403 |
| Product Name | Unience XLPE HFC8015 |
| Manufacturer | Unience |
| Material Type | Cross-linked polyethylene (XLPE) |
| Halogen Content | Halogen-free |
| Flame Retardancy | IEC 60332-1-2 |
| Density | 1.15 g/cm³ |
| Tensile Strength | ≥12.5 MPa |
| Elongation At Break | ≥200% |
| Volume Resistivity | ≥1.0×10^15 Ω·cm |
| Dielectric Strength | ≥25 kV/mm |
| Dielectric Constant | ≤2.5 |
| Operating Temperature | -40°C to +125°C |
| Thermal Aging | 135°C × 168 h |
| Oxygen Index | ≥28% |
| Crosslinking Method | Electron beam or peroxide |
| Color | Black or natural |
As an accredited Unience XLPE HFC8015 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Unience XLPE HFC8015 is supplied in 25 kg moisture-resistant PE-lined bags, palletized and labeled for industrial storage and transport. |
| Container Loading (20′ FCL) | A 20′ FCL typically holds approximately 20 metric tons of Unience XLPE HFC8015 in 25 kg bags, palletized and securely loaded. |
| Shipping | Unience XLPE HFC8015 is typically shipped as a non-hazardous solid in sealed, moisture-barrier bags or cartons, palletized and secured. Store and transport in a cool, dry, well-ventilated area away from direct sunlight and ignition sources. Avoid bag damage; verify the SDS and local transport rules before shipment. |
| Storage | Store Unience XLPE HFC8015 in a cool, dry, well-ventilated area, away from heat, ignition sources, and direct sunlight. Keep original containers closed, labelled, and palletized to prevent moisture ingress and mechanical damage. Avoid contact with incompatible materials. Maintain stable temperature and follow the manufacturer’s safety data sheet and local regulations. Use suitable PPE when handling and inspect containers regularly for leaks or deterioration. |
| Shelf Life | Shelf life is typically 12 months from date of manufacture when stored unopened, dry, and below 30°C, protected from sunlight. |
Unience XLPE HFC8015 is supplied as a silane-grafted, halogen-free flame-retardant crosslinkable polyolefin compound for low-voltage extruded insulation. The curing mechanism is moisture-initiated hydrolysis of grafted alkoxysilane groups followed by condensation, producing a thermoset network without peroxide decomposition byproducts. The material enters the melt stream as a thermoplastic, which permits thin-wall extrusion and high line speeds, then cures after cooling into a matrix with elevated-temperature deformation resistance. The following application entries cover building wire, photovoltaic cable, rolling-stock wiring, industrial control cable, and marine low-voltage insulation. Typical process windows cited below are drawn from public extruder and cable-standard practice; product-specific values should be confirmed against the current supplier specification.
Compliance framework for fixed-installation building wire insulation rests on construction products verification under EN 50575:2014/A1:2016 when placed on the European market, insulation construction under IEC 60502-1:2021 for 0.6/1 kV extruded-core designs, and US market recognition under ANSI/UL 44 with reference tests in UL 1581. For black line wire and XHHW-2 constructions, HFC8015 is metered neat at 100 phr; carbon-black masterbatch is added at 2.5 ± 0.3 wt%, and non-black colours are produced with compatible masterbatch at 1.5–3.0 wt%. Masterbatch loadings above 3.5 wt% begin to dilute the crosslinkable phase, shifting hot set elongation toward 175% and reducing tensile strength below typical wet-aged values, so the cure schedule must be revalidated through IEC 60811-501. Industrial practice uses a 90 mm 25:1 L/D single-screw extruder with a compression screw and an 80/120/80 mesh screen pack; barrel zones from feed to head are set at 130°C, 145°C, 155°C, 165°C, and 170°C, with head pressure controlled at 150–220 bar. Annealed copper or aluminium conductors are preheated to 70–90°C before entering the crosshead; the hot extrudate is cooled in a 20–35°C water trough to freeze strand geometry. Moisture curing in hot water at 75–85°C for 4–8 h follows, with the endpoint taken as hot set elongation ≤175% and permanent set ≤15% under 0.2 MPa at 200°C for 15 min. Terminal products include XHHW-2, XHHW, USE-2, and fixed-installation 0.6/1 kV single-core building cable. Handling limits are operational rather than rhetorical: sealed pellet containers must remain closed below 60% RH, open hopper residence must not exceed 4 h at 30°C and 70% RH, and hot-air pre-drying above 50°C must be avoided because surface hydrolysis initiates pellet-scale gel particles that later create discontinuities in the insulation wall.
Photovoltaic cable insulation processed from HFC8015 occupies a tighter thermal-endurance and weathering window than building wire. The governing specifications are EN 50618:2014 for harmonized H1Z2Z2-K single-core solar cable and IEC 62930:2017 for international DC cable; optional North American constructions follow UL 4703. The formulation addition ratio is 100 phr HFC8015; black sheathing receives UV-stabilized carbon-black masterbatch at 2.0–3.5 wt%, while tinted insulation layers use organic pigment masterbatch at 1.5–2.5 wt%. The insulation layer thickness for 1.5–35 mm² tinned copper Class 5 conductors typically falls between 0.5 mm and 0.8 mm. The HFC8015 insulation core must not be diluted with non-FR polyolefin because damp-heat stability, low-smoke performance, and halogen acid gas release are evaluated at the complete cable level. Production equipment for these constructions is usually a 65 mm 24:1 L/D single-screw extruder with a pressure tube or annulus crosshead, conductor preheating at 60–90°C, melt profile 135–175°C, and haul-off speeds between 150 m/min and 400 m/min depending on outer diameter. After extrusion the cable passes a 20–35°C cooling trough and is coiled onto perforated reels for moisture cure. Hot-water curing at 85 ± 3°C for 8–12 h is standard for wall thicknesses below 0.8 mm; saturated-steam curing at 60°C for 24–48 h is used for thicker walls to avoid blistering at the conductor interface. Verification of cure uses IEC 60811-501 hot set at 200°C under 0.2 MPa; acceptable elongation is ≤175%, and shrinkback at 100°C for 24 h must remain ≤4%. Terminal product types are H1Z2Z2-K rated 1.5 kV DC, PV1-F rated 0.6/1 kV AC, UL 4703 PV wire, and IEC 62930 single-core solar cable.
Railway rolling-stock fixed wiring requires a halogen-free insulation layer that can survive the fire hazard assessment of EN 45545-2:2013 + A1:2018 and construction uniformity under EN 50264-1 and EN 50264-3. HFC8015 is processed at 100 phr; identification masterbatch for phase coding is added at 1.5–2.5 wt%, and no separate halogenated FR masterbatch is used because the compound’s halogen-free flame-retardant package is designed to support R15/R16 low-smoke and low-toxicity verification. Wall thickness for standard-wall rolling-stock cable commonly ranges from 0.8 mm to 1.2 mm; thin-wall versions down to 0.4 mm require tighter dimensional control. Extrusion equipment is typically a 90 mm 25:1 L/D single-screw extruder with a vacuum vent at -0.6 to -0.8 bar; the barrel temperature profile is held between 130°C and 165°C, and the melt temperature at the die must not exceed 165°C. The halogen-free mineral filler system releases surface moisture if the melt is overheated, producing porosity and reducing tensile properties; the vacuum vent must be maintained because wet filler systems create steam pressure and die-face deposition. Conductors are preheated to 70–100°C; a laser or X-ray micrometer records wall-thickness variation, and the acceptable eccentricity is ±10% around the true-diameter centroid. Finished rolling-stock cables are partially cured, twisted into multi-core assemblies, then immersed in water at 75–85°C for 8–14 h. Cure endpoint is hot set per IEC 60811-501 with ≤175% elongation. Published data for HFC8015 specifically in HL3 railway bundles is limited; final fire classification under EN 45545-2 R15/R16 must be certified on the complete cable construction rather than inferred from the insulation compound alone. Terminal product types are standard-wall and thin-wall screened rolling-stock power and control cables to the EN 50264 series.
Industrial control and instrumentation cable insulation produced from HFC8015 is constrained less by the melt phase than by the conflict between cabling geometry and final cure. The construction standard for 0.6/1 kV multi-core control cable is IEC 60502-1:2021; bundled flame spread is assessed by IEC 60332-3-22, smoke density by IEC 61034-2, and halogen acid gas release by IEC 60754-1 and IEC 60754-2. HFC8015 is added at 100 phr with colour masterbatch at 1.5–2.5 wt%. Insulation wall thickness is 0.6–1.0 mm depending on conductor cross-section; the extruder is a 90 mm 25:1 L/D single-screw machine with melt temperature 140–160°C, head pressure 120–200 bar, and line speed 100–250 m/min. After extrusion, cores are water-cooled to 20–35°C and wound with low tension to prevent telescope formation. The process conflict occurs because fully cured insulated cores develop high bending stiffness, which prevents uniform lay-up into twisted pairs, triads, and concentric layers; completely uncured cores deform during cabling and lose wall-thickness concentricity. Plant practice is to interrupt the moisture cure when hot set elongation has reached 60–70% of the target value, then finish curing on the complete cable in hot water at 70–80°C for 12–24 h. Reel-centre radial cure gradient is the recurring production failure: inner layers of a densely wound reel can retain permanent set 2–4% higher than outer layers when forced circulation is absent. Terminal products are shielded and unshielded 0.6/1 kV control cable, screened instrumentation cable, and industrial fieldbus cable.
Marine and offshore low-voltage power cable insulation is specified through IEC 60092-350 and IEC 60092-353, with fire testing for bunched cables under IEC 60332-3-22, smoke release under IEC 61034-2, and halogen acid gas under IEC 60754-1/2. HFC8015 is dosed at 100 phr; black masterbatch additions are held to 2.5–3.0 wt% and colour masterbatch to 1.5–2.5 wt%. The insulation layer thickness for 0.6/1 kV marine power cores is commonly 0.8–1.4 mm, and the cured insulation must provide deformation resistance under short-circuit heating while retaining low-smoke and low-acid-gas evolution. Extrusion is performed on a 90 mm 30:1 L/D single-screw extruder with vacuum drying at -0.7 to -0.9 bar, melt profile 130–165°C, conductor preheat at 70–90°C, and line speed 50–150 m/min due to the heavier wall sections. The molten tube is cooled in a 20–35°C water trough before winding. Curing proceeds on perforated reels in a controlled chamber at 80°C and 90% RH for 24–48 h; this slower route prevents the outer surface from developing a cured skin that would block water penetration into the inner annulus. The dominant limitation is reel-core water circulation: if saturated air or hot water cannot reach the inner reel layers, hot set values may remain above 175% after the scheduled cycle. A secondary limitation is the interaction between colour concentrates and the condensation catalyst; amine-containing carrier systems must be excluded unless qualified, because catalyst deactivation can extend cure time by more than 30% and leave inner-wall hot set above 175%. Terminal product types are IEC 60092-350 low-voltage shipboard power cable, offshore supply cable, and fixed marine wiring.
| Application | Construction standard | Fire/smoke/halogen method | Cure verification | Terminal cable type |
|---|---|---|---|---|
| Building wire | IEC 60502-1:2021, UL 44 | IEC 60332-3-24, IEC 61034-2, IEC 60754-1 | Hot set 200°C / 0.2 MPa per IEC 60811-501 | XHHW-2, USE-2 |
| Photovoltaic cable | EN 50618:2014, IEC 62930:2017, UL 4703 | IEC 61034-2, IEC 60754-1/2, ISO 4892-2 | Hot set 200°C / 0.2 MPa; shrinkback 100°C/24 h ≤ 4% | H1Z2Z2-K, PV1-F, UL 4703 PV wire |
| Rolling-stock wiring | EN 50264-1, EN 50264-3 | EN 45545-2, IEC 61034-2, IEC 60754-1/2 | Hot set 200°C / 0.2 MPa per IEC 60811-501 | EN 50264 screened power/control cable |
| Industrial control cable | IEC 60502-1:2021 | IEC 60332-3-22, IEC 61034-2, IEC 60754-1/2 | Partial cure to 60–70% hot set, final 70–80°C/12–24 h | 0.6/1 kV control and instrumentation cable |
| Marine low-voltage cable | IEC 60092-350, IEC 60092-353 | IEC 60332-3-22, IEC 61034-2, IEC 60754-1/2 | Chamber cure 80°C/90% RH for 24–48 h | IEC 60092 shipboard and offshore cable |
Competitive Unience XLPE HFC8015 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!