| HS Code | 158110 |
| Productname | Unience XLPE HFC8013 |
| Materialtype | Crosslinkable semiconductive ethylene-vinyl acetate copolymer compound |
| Application | Conductor and insulation shielding for medium- and high-voltage power cables |
| Color | Black |
| Form | Pellets |
| Density | 1.15 g/cm³ |
| Meltflowrate | 2.5 g/10 min at 190°C/2.16 kg |
| Volumeresistivity | < 100 ohm-cm at 90°C |
| Tensilestrength | 2000 psi (13.8 MPa) |
| Elongationatbreak | 200% |
| Hotelongation | 100% at 200°C |
| Curesystem | Peroxide-cured |
| Processingmethod | Extrusion |
| Dielectricconstant | 2.5 |
| Dissipationfactor | 0.01 |
| Hardness | 90 Shore A |
| Brittlenesstemperature | -40°C |
| Continuousoperatingtemperature | 90°C |
As an accredited Unience XLPE HFC8013 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Unience XLPE HFC8013 is supplied in 25 kg moisture-proof bags with PE liner, palletized and stretch-wrapped for safe handling. |
| Container Loading (20′ FCL) | Unience XLPE HFC8013 is loaded into a 20′ FCL container in sealed, palletized packaging, properly secured for safe ocean transport. |
| Shipping | Unience XLPE HFC8013 is typically shipped as a solid crosslinkable polyethylene compound in sealed, moisture-resistant bags or containers via standard freight. Keep dry, cool, and away from ignition sources; prevent package damage and contamination. Confirm transport classification, UN number if any, and labeling against the current SDS before shipment. |
| Storage | Store Unience XLPE HFC8013 in a cool, dry, well-ventilated warehouse away from direct sunlight, heat, ignition sources, moisture, and contaminants. Keep it in original, sealed packaging, off the floor, and follow manufacturer stacking and shelf-life guidance. Avoid prolonged high-temperature storage. Use appropriate PPE and consult the SDS for detailed handling and emergency measures. |
| Shelf Life | Typically 12 months from date of manufacture when stored unopened in a cool, dry place, protected from moisture and sunlight. |
For fixed-building installations operating at 0.6/1 kV, conductor insulation layers are commonly manufactured from silane-grafted, moisture-curing XLPE compounds of the HFC8013 class. In this segment, the downstream formulation is set at 100 phr HFC8013, with 1.0–3.0 wt% colour masterbatch for circuit identification and 2.0–5.0 wt% carbon black masterbatch where UV exposure during storage or installation is anticipated. Processing on single-screw extruders with L/D 25:1–30:1 and a compression ratio of 1.5–2.0 requires barrel zone settings of 135 °C to 160 °C, conductor preheat at 80–120 °C, and head pressure maintained between 80–160 bar to prevent surface melt fracture. The extrudate is cured in a water bath or sauna at 70–90 °C for 2–6 h, depending on wall thickness of 0.8–1.8 mm and line speed of 200–800 m/min. Pre-drying of the compound at 70 °C for 2 h is required when sealed packaging has been exposed to relative humidity above 60% because absorbed moisture above 300 ppm produces pitting and premature cure during extrusion. Alkylamine-based processing additives should be avoided due to the risk of early crosslinking in the screw. Compliance is assessed under IEC 60502-1:2021 for power cable construction, IEC 60754-1 and IEC 60754-2 for acid gas emission, and IEC 61034-2 for smoke density. Terminal products include solid and stranded copper building wire, conduit wire, and low-voltage distribution cable for residential and commercial panels.
Photovoltaic string cabling presents a different thermal-oxidative aging profile because the insulation is exposed to 90 °C continuous wet conductor temperature, high DC bus voltages, and UV irradiance across a 25-year design service life. In this application, HFC8013 is loaded at 100 phr with 2.0–4.0 wt% UV-stabilised carbon black masterbatch and 0.2–0.6 phr antioxidant masterbatch; silicone processing aid is kept at 0.3–0.8 wt% to prevent melt fracture at thin-wall extrusion. The compound is extruded over tinned copper conductors of 1.5–35 mm² through a single-screw extruder with L/D 25:1 at melt temperatures of 135–155 °C, followed by moisture cure at 70–90 °C for 4–8 h. Online spark testing at 6–10 kV AC and bending tests at -40 °C are performed after thermal conditioning. The relevant standards are EN 50618:2014, IEC 62930:2017, and TÜV 2PfG 1169/08; low-smoke halogen-free requirements are verified with IEC 60754-2 and IEC 61034-2. Terminal product types include single-core photovoltaic cable for module-to-inverter string wiring, array harnesses, and solar farm DC collection loops.
Multi-pair industrial instrumentation cables installed in petrochemical facilities require the outer sheath to pass vertical tray flame spread testing while retaining low-temperature flexibility after exposure to hydrocarbon condensation. For this segment, HFC8013 is mixed at 100 phr with 1.0–3.0 wt% colour masterbatch and 0.5–1.5 phr silicone processing aid; where oil resistance is specified, a co-extruded polyamide or fluoropolymer barrier may replace direct compound modification. The sheath is extruded over screened twisted pairs with a pressure die at melt temperatures of 130–160 °C, wall thickness of 0.4–1.2 mm, and line speeds of 100–300 m/min. Moisture-induced crosslinking at 75–85 °C for 3–5 h is followed by cold bend testing at -25 °C or -40 °C depending on arctic specification. Compliance is evaluated under IEC 60092-359:2011 for shipboard low-frequency cables, EN 50288-7 for multi-element metallic cables, and IEC 60332-3-24 for vertical flame propagation; acid gas and smoke are tested to IEC 60754-1, IEC 60754-2, and IEC 61034-2. Terminal products include fieldbus cables, analog transmitter loops, and control panel interconnections.
| Sector | Primary standard | Critical test method | Limiting criterion |
|---|---|---|---|
| Low-voltage building wire | IEC 60502-1:2021 | IEC 60754-2 | pH ≥ 4.3; conductivity ≤ 10 µS/mm |
| Photovoltaic string cable | EN 50618:2014 | IEC 61034-2 | Light transmittance ≥ 60% |
| Industrial instrumentation | IEC 60092-359:2011 | IEC 60332-3-24 | Char height ≤ 2.5 m above burner |
| Electric vehicle harness | ISO 19642-5:2019 | IEC 60332-1-2 | No flame propagation beyond sample |
| Data-center feeder | UL 44:2018 | UL 1685 | Damage height ≤ 1.5 m |
| Rail transit cable | EN 45545-2:2020 | EN 50305:2020 | Abrasion resistance after 150 cycles |
High-voltage automotive battery harness insulation must withstand continuous conductor temperatures of 150 °C for a defined thermal endurance class, while the small bend radius in vehicle routing creates tensile strain at the conductor-insulation interface. The downstream formulation uses HFC8013 at 100 phr, carbon black masterbatch at 1.0–2.5 wt%, and a processing stabilizer package at 0.5–1.5 phr to resist thermal-oxidative embrittlement during extrusion. Cable production is conducted on high-precision single-screw extruders with L/D 25:1–30:1, melt temperatures of 140–160 °C, and conductor preheat at 100–130 °C. The processing window is critical: sustained melt temperatures above 165 °C initiate premature gel formation and die-lip residue, while melt temperatures below 140 °C produce high head pressure, poor surface finish, and micro-voids after curing. Wall thickness is controlled at 0.6–1.8 mm for conductor sizes from 16 mm² to 95 mm². The moisture cure cycle of 80 °C for 4–8 h is preferred because it avoids the high-temperature peroxide decomposition products that could attack tinned copper plating. If product-specific thermal endurance curves are required, published data for this specific configuration is limited; qualification tests on the final cable assembly to ISO 19642-5:2019 remain mandatory. Electrical testing is performed under LV 112-1, with flame retardance assessed by IEC 60332-1-2 and moisture resistance after thermal ageing per ISO 6722-1. Terminal product types include high-voltage power leads, DC fast-charging cable assemblies, and battery pack jumper harnesses.
In data-center feeder installations, RHW-2 and XHHW-2 conductors require insulation with a 90 °C continuous wet and dry rating and an emergency overload rating of 130 °C, creating a severe oxidative environment that must be met without compromising halogen-free emission limits. Here, the compounding recipe for HFC8013 is set at 100 parts by weight, with 2.0–5.0 wt% TiO₂-based white masterbatch or 0.5–1.5 wt% copper phthalocyanine colour masterbatch for circuit identification, plus 0.3–0.8 wt% processing aid. Insulation is extruded over soft-drawn bare copper or tinned copper conductors from 14 AWG to 1000 kcmil on single-screw extruders with L/D 25:1–30:1, melt temperatures of 135–155 °C, and conductor preheat of 95–120 °C; line speed ranges from 50 m/min on 1000 kcmil to 400 m/min on 14 AWG due to pay-off and take-up tension limits. Crosslinking proceeds in a water bath at 70–90 °C for 3–6 h, with longer soak times required for wall thicknesses above 2.0 mm to avoid residual uncrosslinked core sections. Compliance with UL 44:2018 and UL 1581 is required for XHHW-2 construction, while flame propagation is measured under UL 1685 or IEEE 1202:2019 for tray cable configurations. Terminal products include service entrance feeders, branch circuit conductors, and power distribution risers in hyperscale data centers.
| Sector | HFC8013 loading | Additive loading | Melt temperature | Wall thickness | Crosslinking condition |
|---|---|---|---|---|---|
| Low-voltage building wire | 100 phr | Carbon black 2.0–5.0 wt%; processing aid 0.2–0.8 wt% | 135–160 °C | 0.8–1.8 mm | 70–90 °C, 2–6 h |
| Photovoltaic string cable | 100 phr | UV carbon black 2.0–4.0 wt%; antioxidant 0.2–0.6 phr | 135–155 °C | 0.8–1.2 mm | 70–90 °C, 4–8 h |
| Industrial instrumentation | 100 phr | Colour masterbatch 1.0–3.0 wt%; silicone processing aid 0.5–1.5 phr | 130–160 °C | 0.4–1.2 mm | 75–85 °C, 3–5 h |
| Electric vehicle harness | 100 phr | Carbon black 1.0–2.5 wt%; stabilizer 0.5–1.5 phr | 140–160 °C | 0.6–1.8 mm | 80 °C, 4–8 h |
| Data-center feeder | 100 phr | TiO₂ white 2.0–5.0 wt% or colour 0.5–1.5 wt%; processing aid 0.3–0.8 wt% | 135–155 °C | 0.8–2.4 mm | 70–90 °C, 3–6 h |
| Rail transit cable | 100 phr | Weathering masterbatch 2.0–4.0 wt%; antioxidant 0.2–0.6 phr | 145–165 °C | 0.2–0.5 mm | 75–85 °C, 3–6 h |
The rail transit cable envelope imposes simultaneous demands for low smoke opacity, limited heat release, and resistance to aggressive cleaning agents used on train washdown lines. HFC8013 is specified at 100 phr with 2.0–4.0 wt% colour and weathering masterbatch and 0.2–0.6 phr antioxidant masterbatch; the compound is not plasticized because ester-based plasticizers would raise peak heat release rate above EN 45545-2:2020 hazard level limits. Thin-wall insulation or sheathing is extruded over tinned copper conductors using a 25:1 L/D single-screw extruder at melt temperatures of 145–165 °C, wall thickness of 0.2–0.5 mm, and line speeds of 100–300 m/min. Moisture curing at 75–85 °C for 3–6 h is followed by abrasion resistance testing under EN 50305:2020, low-temperature bending per EN 60811-504 at -40 °C, and acid gas emission testing per IEC 60754-1. Smoke opacity is measured under IEC 61034-2, with minimum transmittance thresholds established by the vehicle fire safety plan. Terminal products include control and power cables for metro vehicles, high-speed train fixed wiring, and locomotive interconnect looms.
Competitive Unience XLPE HFC8013 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!