Unience XLPE HFC6110

    VTB
    Specifications
    HS Code 167170
    Density 0.92 g/cm³
    Meltflowrate 2.0 g/10 min (190°C, 2.16 kg)
    Tensilestrength ≥17.0 MPa
    Elongationatbreak ≥500%
    Hotsetelongation ≤175% (200°C, 15 min, 0.2 MPa)
    Permanentdeformation ≤15% (200°C, 15 min, 0.2 MPa)
    Volumeresistivity ≥1.0×10^14 Ω·m
    Dielectricconstant ≤2.35 (50 Hz)
    Dissipationfactor ≤5.0×10^-4 (50 Hz)
    Dielectricstrength ≥25 kV/mm
    Gelcontent ≥80%
    Thermalaging 135°C × 168 h
    Moisturecontent ≤0.05%
    Color Natural
    Form Pellets

    As an accredited Unience XLPE HFC6110 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Unience XLPE HFC6110 is supplied in sealed 25 kg moisture-barrier bags with polyethylene liners, suitable for safe storage and transport.
    Container Loading (20′ FCL) 20′ FCL loaded with Unience XLPE HFC6110 in sealed, labeled packaging; evenly distributed, secured, and moisture-protected for safe ocean shipment.
    Shipping Unience XLPE HFC6110 is supplied in moisture-proof bags or drums, labeled per transport regulations. Keep dry, cool, ventilated, and away from direct sunlight, heat, and ignition sources. Handle per SDS; classify as non-dangerous goods unless local rules state otherwise. Secure loads for transport.
    Storage Store Unience XLPE HFC6110 in a cool, dry, well-ventilated area away from direct sunlight, heat, sparks, and ignition sources. Keep containers or bags tightly closed to prevent moisture and contamination. Do not store near incompatible chemicals such as strong oxidizers. Protect from physical damage, maintain clear labeling, use first-in-first-out, and follow the manufacturer’s shelf-life and SDS recommendations.
    Shelf Life Shelf life is typically 6 months from manufacture when stored unopened in original packaging in a cool, dry place.
    Application of Unience XLPE HFC6110

    Application-Specific Processing Data for Unience XLPE HFC6110

    Unience XLPE HFC6110 is evaluated as a silane-crosslinkable halogen-free polyolefin compound for insulation layers in cable constructions where wet or steam curing is available on the production line. The following scenarios are limited to cable families for which moisture-cured silane crosslinking has been demonstrated in industrial production practice, not to laboratory-scale mixing or compression molding. All processing ranges reflect equipment-dependent variation across 45 mm to 90 mm single-screw extruders with barrier mixing sections and L/D ratios of 24:1 to 30:1. Values stated as acceptance thresholds are derived from standardised cable testing methods; material-specific supplier data for unusual end-use configurations is identified where published data is limited.

    Low-Voltage Building Wire Insulation Sits Between Pre-scorch and Under-cure in Silane-XLPE Extrusion

    Extrusion of HFC6110 directly onto copper conductors in the range 1.5 mm² to 35 mm² is governed by IEC 60502-1:2021 for rated voltages up to 1 kV and by UL 44:2018 for thermoset-insulated wires in North American conduit installations. Halogen-free flame-retardant variants are additionally subjected to single-cable vertical flame propagation under IEC 60332-1-2:2004, acid gas generation under IEC 60754-2:2011, and smoke density under IEC 61034-2:2005. The building-wire formulation consumes HFC6110 as supplied, with edge-trim regrind limited to 10 wt% of total compound feed. Regrind loads above 10 wt% create a measurable reduction in tensile elongation after thermal aging because the silane-grafted sites undergo partial consumption during the first heat history. Melt flow rate for incoming batches is verified according to ISO 1133-1:2022 at 190°C and 21.6 kg where the specification includes a high-load gate to control lot-to-lot extrusion pressure.

    Downstream processing uses a single-screw extruder with a barrier mixing section and an L/D ratio of 24:1 to 30:1. The screw temperature profile is set from 145°C at the feed zone to 170°C in the metering zone, with head and die temperatures held at 150–165°C. Conductor preheating to 70–90°C is necessary to prevent adhesion loss at the copper interface. A pressure die with draw ratio between 1.2:1 and 1.6:1 maintains concentricity above 85%. Crosslinking proceeds in a wet sauna at 85–95°C and 85–95% relative humidity for 6–24 h, depending on wall thickness. Thin sections cure faster, but thick walls require staged ramping to avoid residual condensation-inhibitor entrapment at the conductor boundary. Hot-set testing per IEC 60811-507:2012 at 200°C and 0.20 MPa must show elongation under load ≤175% and permanent set after cooling ≤15%. Failure modes observed on production lines include die drool caused by condensation catalyst migration and surface roughness when the feed hopper ingests >150 ppm moisture during high-humidity shifts.

    Terminal finished products include single-core non-sheathed conductors for fixed protected wiring in conduits, consumer units, and switchgear. Rated operating temperature is 90°C continuous, with short-circuit temperature 250°C. The product family corresponds to H07V2-K and H07V2-R constructions under harmonised low-voltage cable designations, as well as XHHW-2 insulated conductors under UL 44.

    Photovoltaic DC cable insulation imposes simultaneous damp-heat aging and low-temperature impact requirements that remove most non-crosslinked polyolefin compounds from the supplier list. EN 50618:2014 and IEC 62930:2017 specify 1,000 h damp-heat exposure at 85°C and 85% relative humidity followed by insulation resistance and mechanical property retention; UL 4703:2021 adds the North American 1500 V DC photovoltaic wire framework. The formulation ratio for this application is 100 parts HFC6110, with no post hoc addition of ATH/MDH because the fire-retardant system is already dispersed in the pellet. Regrind addition is not permitted for EN 50618 constructions; published data for the specific reprocessing tolerance of HFC6110 under this standard is limited, and any use of reprocessed trim must be validated against damp-heat stability. A colour masterbatch based on a silane-compatible olefin carrier may be added up to 2 wt%, but higher levels reduce crosslink density to the point where hot-set elongation exceeds the 175% limit.

    Photovoltaic DC cable insulation compliance matrix for HFC6110
    PropertyTest methodAcceptance value
    Damp heat agingIEC 60068-2-78:201285°C/85% RH, 1,000 h
    Hot-set elongationIEC 60811-507:2012≤175% at 200°C/0.20 MPa
    Permanent setIEC 60811-507:2012≤15%
    Low-temperature impactIEC 60811-506:2012No cracks at -40°C
    Smoke densityIEC 61034-2:2005Light transmittance ≥60%
    Acid gas generationIEC 60754-2:2011pH ≥4.3, conductivity ≤10 μS/mm

    Downstream extrusion for PV wire uses a pressure tube die and a screw with 25:1 to 30:1 L/D. The conductor is preheated to 80–120°C; the melt enters the die at 150–175°C. Typical insulation wall thickness for 4 mm² and 6 mm² PV wire is 0.5–0.8 mm, with line speeds from 80 m/min to 160 m/min. Crosslinking occurs in a water bath or sauna at 80–95°C; post-cure conditioning at ambient warehouse temperature is minimum 48 h before final spark testing. An inline hot-set sample is taken every 2 h to detect batch-to-batch variation in the catalyst masterbatch; a sudden increase in permanent set above 15% indicates insufficient silane condensation or steam ingress into the feed hopper.

    The terminal product is a single-core PV1-F style photovoltaic cable rated 1.5 kV DC, with a 120°C continuous conductor temperature under EN 50618 and a 25-year service design target. These cables are used in module stringing, inverter DC input, and rooftop array interconnections.

    Why Does Thin-Wall Automotive Primary Wire Require Moisture-Cured XLPE Instead of EB-Crosslinked Grades?

    For thin-wall primary insulated conductors specified under ISO 6722-1:2016 and SAE J1128:2021, the continuous conductor temperature requirement of 125°C for Class C or 150°C for Class D cannot be met by thermoplastic polyolefin blends. HFC6110 is applied in automotive thin-wall lines where electron-beam crosslinking is unavailable or where the conductor geometry includes sharp strand edges that cause EB dose shadowing. The blend ratio for flexibility adjustment is 100 parts HFC6110 with 10–15 parts of linear low-density polyethylene; addition beyond 15 phr induces a cliff-edge failure in hot-set elongation because the non-grafted LLDPE phases act as defects in the silane network. Conversely, addition below 10 phr may not produce the required flexural modulus for high-speed harness routing. Material lot acceptance includes melt viscosity stabilisation to prevent molecular weight tails that increase conductor adhesion variation in thin walls.

    Extrusion is performed on a 30:1 L/D barrier screw with a Maddock mixing section. The zone profile runs 140°C to 160°C, with the head held at 155°C; melt temperatures above 180°C initiate premature scorch. Before extrusion, HFC6110 is pre-dried at 60°C for 4 h when ambient relative humidity exceeds 60%. Conductor preheat is set at 80–120°C, and thin-wall insulation of 0.20–0.40 mm is extruded at line speeds from 250 m/min to 450 m/min. The die land is shortened relative to building-wire tooling to reduce residence time; die drool associated with condensation catalyst migration is controlled by wiping intervals of 8 h rather than by formulation dilution. A production-scale failure mode encountered on high-speed automotive lines is intermittent spark-test rejection after only 2–3 h of stable output, caused by condensation of low-molecular-weight silane fractions at the die exit and subsequent transfer to the insulation surface.

    Terminal constructions include automotive primary wire for engine compartments, chassis harnesses, and battery management sensor leads. Typical wire types correspond to thin-wall classes designated by the vehicle manufacturer specification under ISO 6722-1. A commercial limitation is that the moisture-cure cycle requires batch conditioning for 24–48 h, which must be planned when automotive harness manufacturing moves to just-in-time sequencing.

    When HFC6110 is used as insulation for multi-core instrumentation and control cables in process plants, the controlling production variable is not the extrusion temperature but the preservation of concentricity after multiple twisting and shielding operations. IEC 60092-376:2017 for shipboard control cables and EN 50288-7:2005 for industrial communication cables require dimensional stability under bending, while bunched flame propagation under IEC 60332-3-24:2018 is mandatory for Category C installations. The compound is run at 95 parts HFC6110 to 5 parts tin catalyst masterbatch when the extrusion line operates in Sioplas mode; a static mixer at 50–70°C prior to the feed throat lowers variation in catalyst dispersion to ±0.3 wt%. Larger ratio deviations beyond ±1.0 wt% produce inconsistent crosslink density in cable lengths below 500 m, detectable as oscillation in hot-set values.

    The insulation is applied over pre-twisted conductors with a pressure die. A wall thickness of 0.4–0.7 mm is extruded at 60–120 m/min, with a concentricity threshold of ≥80%. Inline spark testing at 3 kV AC after crosslinking identifies pinholes caused by moisture release from paper-filled conductor interstices. The cable passes through a warm-water trough at 85°C for 8–16 h; for multi-layer constructions, curing is staged to prevent differential shrinkage between the inner and outer insulation layers. The test set includes insulation resistance constant per IEC 60811-501:2012 and hot-set per IEC 60811-507:2012.

    Finished products include screened twisted-pair cables for process automation, 300/500 V control cables for HVAC actuators, and shipboard control cables with halogen-free outer sheaths. The insulation layer is rated for 90°C continuous operation in most industrial control applications, with short-term excursions to 150°C permitted for fault current duration.

    Rail Transit Wall-Insulation Performance Under EN 45545-2 Hazard Level 3

    DIN EN 50264-1:2008 rolling stock cables with crosslinked insulation are specified where EN 45545-2:2020 Hazard Level 3 applies to interior and exterior wiring. HFC6110 is evaluated for the insulation layer, not the outer jacket, because the compound's halogen-free package is intended to limit acid gas release and smoke obscuration rather than to replace elastomeric jacketing compounds. Colour masterbatch addition is limited to ≤3 wt%; no supplemental ATH/MDH is added on the production floor because post hoc filler addition disrupts the factory-dispersed flame-retardant morphology and creates agglomerates that fail the 0.1 mm particle-size inspection under cable surface microscopy. Blend with LLDPE is avoided in this segment because it lowers hot-set pass margin below the rail specification reserve.

    Extrusion runs on a 30:1 L/D low-shear screw design, because high-shear mixing raises melt temperature without improving flame-retardant dispersion. The melt temperature is held at 135–155°C, and line speed ranges from 40 m/min to 90 m/min for wall thicknesses between 0.35 mm and 0.60 mm. Water cure is performed at 70–95°C, followed by 24 h ambient conditioning. Hot-set testing per EN 60811-507:2012 is supplemented by smoke density measurement under EN 61034-2:2005, which must remain above 60% light transmittance, and acid gas analysis under EN 60754-2:2011 with pH ≥4.3 and conductivity ≤10 μS/mm. The operational boundary for this scenario is the narrow cure window: under-cure is detected as a rise in hot-set elongation above 175%, while over-exposure to steam above 95°C creates surface micro-cracking that reduces smoke-density pass margin.

    Terminal products are thin-wall insulated conductors inside EN 50264-1 control and power cables for rail vehicles, metro rolling stock, and trams. Rated voltage is 300/500 V or 0.6/1 kV depending on construction. The insulation is not directly exposed; it is protected by a halogen-free outer sheath.

    Under high-humidity warehouse storage in equatorial production sites, surface moisture absorption by HFC6110 granules can generate pinholes during insulation expansion after the die. Pre-drying to 70°C for 3–4 h is required when the granules have been exposed to >60% relative humidity for more than 24 h. For electric vehicle charging cable insulation, EN 50620:2017 and IEC 62893-1:2017 specify the combined low-smoke and low-temperature kink resistance that makes silane-crosslinked halogen-free compounds the primary material choice over PVC and thermoplastic elastomers. The addition ratio is 100 parts HFC6110 with 5 parts catalyst masterbatch; colour concentrates for surface coding are limited to 2 wt% and must use a silane-compatible LDPE carrier. The use of transparent UV stabilizer masterbatch beyond 1 wt% is not recommended because it reduces gel content below the 70% acceptance threshold determined by ASTM D2765-16.

    Production equipment includes a 60 mm single-screw extruder with 30:1 L/D, compression ratio 2.2:1, and a double-head vacuum loader. The die temperature is held at 150–160°C; conductor preheat is 70–100°C. Core insulation wall thickness for a 10 mm² power core is 0.8–1.2 mm, and signal cores are insulated to 0.3–0.5 mm. Line speed is 40–120 m/min due to the need for accurate wall-thickness control around multiple conductors. Crosslinking is completed in a steam chamber at 90°C for 3–6 h for thin signal cores and 12–18 h for power cores. The final core must pass 3.5 kV AC spark testing, followed by capacitance stability measurements before stranding into the charger cable.

    Terminal products include AC and DC electric vehicle charging cables with a rated voltage of 450/750 V for signal cores and 0.6/1 kV for power cores. The insulation layer supports continuous conductor temperature of 90°C under EN 50620, with short-duration conductor temperature 150°C for emergency overload. Low-temperature kink testing to -40°C is performed on the completed cable, not on the insulated core alone.

    Free Quote

    Competitive Unience XLPE HFC6110 prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@sinochem-nanjing.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    Top