| HS Code | 858275 |
| Productname | Unience XLPE HFC6095 |
| Manufacturer | SABIC |
| Materialtype | Cross-linked polyethylene (XLPE) |
| Density | 1.45 g/cm³ |
| Meltflowrate | 2.0 g/10 min (190°C/2.16 kg) |
| Tensilestrength | 12 MPa |
| Elongationatbreak | 200% |
| Flexuralmodulus | 600 MPa |
| Shorehardnessd | 50 |
| Volumeresistivity | 1.0E15 Ω·cm |
| Dielectricconstant | 3.0 at 50 Hz |
| Dissipationfactor | 0.005 at 50 Hz |
| Dielectricstrength | 20 kV/mm |
| Limitingoxygenindex | 32% |
| Ratedtemperature | 125 °C |
| Thermalaging | 135 °C for 168 h |
| Hotset | 200 °C, 15 min, 0.2 MPa |
| Waterabsorption | 0.1% |
| Coldbendtemperature | -40 °C |
| Uvresistance | Yes |
As an accredited Unience XLPE HFC6095 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Unience XLPE HFC6095 is packaged in 25 kg moisture-resistant, foil-lined bags on pallets for safe industrial storage and transport. |
| Container Loading (20′ FCL) | 20′ FCL container loaded with Unience XLPE HFC6095 chemical, securely palletized, sealed, labeled, and documented for safe ocean freight. |
| Shipping | Unience XLPE HFC6095 is typically supplied in moisture-barrier bags or octabins on pallets. Ship dry and ventilated, protected from sunlight, heat, and moisture; avoid package damage. Confirm hazardous-goods classification and local transport rules against the current SDS before shipment. |
| Storage | Store Unience XLPE HFC6095 in a cool, dry, well-ventilated area, away from direct sunlight, heat, sparks, flames, and strong oxidizers. Keep containers tightly closed and protect contents from moisture, dust, and contamination. Use original packaging, follow stacking limits, and apply first-in/first-out rotation. Avoid prolonged exposure to elevated temperatures, and observe the manufacturer’s shelf-life and storage recommendations. Do not store near food or feed. |
| Shelf Life | Typical shelf life is 6 months when stored unopened in a cool, dry place, protected from moisture and direct sunlight. |
In 0.6/1 kV building wire manufacturing, where halogen-free flame-retardant performance must coexist with silane-crosslink density and long-term wet insulation resistance, Unience XLPE HFC6095 is processed as the silane-grafted A-component with a condensation catalyst masterbatch metered gravimetrically at a ratio of 95:5 by mass. Pre-drying is required at 60 °C to 70 °C for 2 h to 4 h when ambient relative humidity exceeds 60%, because premature hydrolysis of silane groups ahead of the die can produce pinholes, surface roughness, and nonuniform crosslink density in the finished insulation. Extrusion is performed on a single-screw extruder with 30:1 L/D, a grooved feed section, a low-compression barrier screw, and a screen pack positioned ahead of the breaker plate. Barrel temperatures are normally set from 140 °C at the feed throat to 170 °C in the metering zone, while the die head is held below 180 °C to avoid scorch. Melt pressure at the breaker plate is maintained below 25 MPa; excessive shear heating in stagnant zones initiates premature crosslinking and generates gel particles that are visible as pimples on the insulation surface. After extrusion, the moisture-cure XLPE insulation is crosslinked in a hot-water bath or steam room at 85 °C to 95 °C for 4 h to 8 h, depending on wall thickness up to 1.0 mm. Finished single-core and multi-core building wires are evaluated according to IEC 60502-1:2021 for insulation resistance, IEC 60811-501:2012 for tensile strength and elongation before and after ageing, IEC 60332-1-2:2015 for single-wire flame propagation, and IEC 60754-1:2011 for halogen acid gas content. A common industrial acceptance benchmark for halogen-free silane XLPE insulation is tensile strength not less than 9 MPa and elongation at break not less than 150% before ageing, with at least 70% retention after 168 h at 135 °C; product-specific release data for HFC6095 should be confirmed against the producer certificate of analysis because published values for this exact grade are limited. In building wiring, the compound is typically used as insulation for branch-circuit conductors, appliance internal wiring, and lighting fixture leads, where the terminal product must also pass a 2.5 kV dielectric withstand test conducted in accordance with IEC 60502-1:2021. Direct contact with unplasticized PVC conduit is generally acceptable, but contact with flexible PVC or phthalate-containing bedding compounds should be avoided because plasticizer migration can reduce surface resistivity and degrade wet insulation resistance over time.
Photovoltaic DC cable production imposes simultaneous requirements for wet electrical stability, low-smoke flame performance, hydrolysis resistance, ozone resistance, and resistance to ultraviolet radiation. In 1.5 mm² to 10 mm² single-core solar cables insulated and sheathed with halogen-free XLPE systems, HFC6095 is evaluated under EN 50618:2014 and IEC 62930:2017. A two-layer co-extrusion line with a 90 mm main extruder for the insulation and a 65 mm co-extruder for the jacket is commonly operated at a final line speed between 80 m/min and 200 m/min. The insulation is applied through a pressure die at 150 °C to 165 °C, and the jacket is applied through a tubing die at 155 °C to 175 °C to control die drool caused by metal hydroxide fillers. For thin-wall jackets in the 0.8 mm to 1.2 mm range, the catalyst masterbatch addition is held at 5 ± 0.3 wt%, and in-line ultrasonic scanning is used to verify the absence of voids at the insulation-jacket interface. After extrusion, the reels are stored in a warm-water or steam room at 85 °C for 6 h to 12 h; premature tensioning before complete silanol condensation can create reel memory and shrinkage after cable installation. The halogen-free filler package in HFC6095 is directly relevant to the acid-gas and smoke-density constraints in IEC 60754-2:2011 and IEC 61034-2:2005, where the complete cable construction must demonstrate pH not less than 4.3, conductivity not greater than 10 μS/mm, and light transmittance not less than 60%. In photovoltaic installations, the finished cable is also exposed to 1000 h of accelerated weathering under ISO 4892-2:2013; if the outer jacket contains insufficient UV stabilizer or carbon black, surface crazing can expose the insulation to moisture ingress and reduce wet insulation resistance below the long-term wet test threshold required by EN 50618:2014. The terminal product is a single-core DC cable used between string combiner boxes and inverters, where the halogen-free XLPE system also must resist ammonia and agricultural chemicals when installed on livestock or greenhouse rooftops.
| Evaluation parameter | Standard method | Industrial benchmark | Process implication |
|---|---|---|---|
| Halogen acid gas evolution | IEC 60754-1:2011 | < 0.5% HCl equivalent | Requires chloride-free handling and segregated drying hoppers |
| Smoke density | IEC 61034-2:2005 | ≥ 60% light transmittance | Limits conductor preheat to 120 °C to avoid scorch from filler contact |
| Long-term wet insulation resistance | EN 50618:2014 | Minimum 1000 MΩ·km after extended water immersion at 85 °C | Requires complete moisture crosslink and void-free insulation-jacket interface |
| Single cable flame propagation | IEC 60332-1-2:2015 | Char height ≤ 540 mm | Jacket wall thickness must be uniform; thin spots from tubing-die misalignment are rejectable |
Where ISO 6722 Class C 125 °C primary wire is produced on multi-head extrusion lines with wall thickness from 0.20 mm to 0.45 mm, the critical processing variable for HFC6095 is melt-viscosity stability under high shear. Thin-wall automotive wires are drawn through a crosshead die at linear speeds up to 300 m/min, so the compound must resist die build-up and maintain concentricity across conductor sizes from 0.35 mm² to 2.5 mm². A typical single-screw extruder of 50 mm diameter with 24:1 L/D and a 0.2 mm screen pack is operated with a barrel profile of 130 °C to 160 °C and a die temperature of 165 °C. Conductor preheat is set at 90 °C to 110 °C to improve adhesion between the XLPE insulation and the copper conductor. After extrusion, the moisture-cure XLPE insulation requires reeling and storage at 80 °C to 90 °C in a hot room for 4 h to 6 h before stripping and termination. This post-cure delay is an operational boundary for automotive harness manufacturers accustomed to immediate processing of PVC or electron-beam crosslinked insulation. The terminal products include engine-compartment sensor leads, ABS wheel-speed sensor wiring, and battery management system signal conductors where 125 °C thermal class, low-smoke emission under ISO 6722-12, and resistance to hot engine oil are specified. The final wire is additionally tested for short-term ageing at 150 °C for 240 h, cold bending at -40 °C, and scrape abrasion according to ISO 6722-2:2006. Because the halogen-free filler loading reduces melt draw-down capability compared with unfilled PE, the draw ratio between die exit and copper conductor should not exceed 3:1 to avoid necking and eccentricity defects. If a water trough is used for cooling, the first water section must be maintained above 70 °C to prevent differential quenching stress that later manifests as insulation cracking at the harness bending radius.
Heat-shrinkable tubing made from halogen-free silane XLPE requires the crosslink network to be fully formed before expansion; otherwise the expanded tubing will not recover predictably during end-use installation. HFC6095 is extruded as a tube over a pin and die set at 150 °C to 170 °C, cooled in a vacuum sizing tank to lock outer diameter, and then crosslinked in a hot-water bath at 85 °C to 95 °C for 4 h to 8 h depending on wall thickness. The tube is then heated to 140 °C to 180 °C and expanded by internal air pressure or vacuum over a sizing mandrel, followed by rapid air cooling to freeze the expanded geometry. Shrink ratios of 2:1 and 3:1 are achievable when the gel content determined by xylene extraction under ASTM D2765-16 is at least 65%. A gel content below 55% indicates incomplete silane condensation or catalyst deactivation, producing tubing that wrinkles and splits during recovery. The halogen-free filler package reduces longitudinal recovery force compared with non-flame-retardant XLPE, so the expansion mandrel must be maintained within ±5 °C of the tube set point to prevent localized thinning. In automotive harness breakouts and low-voltage electrical insulation sleeves, the final tube is assessed under UL 224 for flame retardancy and dielectric withstand. The terminal product is used in battery pack insulation and terminal insulation where halogen-free construction is required under IEC 60754-1:2011. A process limitation is that the moisture-cure cycle cannot be shortened by increasing extrusion temperature; above 190 °C, scorch at the die lip produces surface roughness and gel particles that become split defects after expansion.
Multi-pair control cables for industrial automation, transit signalling, and process instrumentation require a halogen-free outer sheath that resists abrasion during conduit pulling and retains flexibility at low temperatures. HFC6095 is processed on a 90 mm single-screw extruder fitted with a 30:1 L/D barrier screw and a double-head crosshead for sheathing over shielded pairs. The compound is dried at 65 °C for 2 h and metered at the hopper with a catalyst masterbatch ratio of 5:95. Barrel temperatures are set from 130 °C at the feed zone to 155 °C in the metering zone, and the head is held at 160 °C to 170 °C. Sheath wall thickness is typically 1.2 mm to 2.0 mm, and line speed is limited by the need to maintain a smooth surface under the halogen-free flame-retardant filler loading; speeds above 60 m/min can induce melt fracture unless a fluoropolymer processing aid is incorporated at 0.2 wt% to 0.5 wt%. Crosslinking is completed at 85 °C for 8 h to 12 h before cable testing. The final sheath is subjected to IEC 60332-3-24 for vertical cable-tray flame spread, IEC 60754-1:2011 and IEC 60754-2:2011 for acid gas and smoke corrosivity, IEC 60811-401 for abrasion resistance, and IEC 60811-504 for low-temperature bending at -25 °C. In railway and tunnel control cables, the same sheath is also evaluated under EN 50267-2-1 and EN 61034-2. The primary failure mode observed on production lines is die build-up at the land zone caused by filler agglomeration and premature silane condensation at the die lip; the die land length is therefore kept below 10 mm and the die set is cleaned after every 8 h of continuous operation. The compound should not be combined with amine-based antioxidant or stabilizer masterbatches because amine species can poison the silanol condensation catalyst and reduce final gel content. The terminal product is used as the outer jacket of unarmoured multi-pair cables, communication backbone cables in automated plants, and signalling cables in underground transit systems.
Offshore platform and rail rolling-stock specifications impose simultaneous low-smoke density, low-acid-gas emission, and resistance to mineral oil or diesel that cannot be met by conventional PVC jackets. HFC6095 is used as the halogen-free XLPE sheath over stranded tinned-copper conductors insulated with mica-glass tape and crosslinked polyolefin in cables conforming to IEC 60092-360:2021 and EN 50264-1:2008. The extrusion line typically uses a 120 mm extruder with 25:1 L/D, a vacuum vent at -0.06 MPa, and a crosshead die maintained at 150 °C to 165 °C. Because offshore cables are built with large diameters from 20 mm to 50 mm, the moisture-cure step must be extended to 12 h to 24 h in a 90 °C steam chamber to achieve uniform crosslink density through the thick sheath wall. The sheath compound is formulated with metal hydroxide flame retardants at high loadings; this raises melt viscosity and reduces elongation after ageing, so the cable manufacturer must verify retention of tensile strength and elongation after 240 h at 110 °C in mineral oil according to IEC 60811-404. In rail applications under EN 45545-2:2020, the completed cable is also tested for flame spread, smoke density, and heat release in a cone calorimeter. The halogen-free filler package contributes to lower peak heat release but may increase water absorption, so the cable is required to pass a 14-day water immersion test at 85 °C with minimum insulation resistance according to IEC 60092-350. The terminal products are main power and control cables on passenger trains, offshore platform lighting and instrument cables, and emergency power cables where evacuation safety requires halogen-free combustion products.
Competitive Unience XLPE HFC6095 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!