| HS Code | 606171 |
| Materialtype | PBT with 30% glass fiber, flame retardant |
| Glassfibercontent | 30% |
| Density | 1.58 g/cm3 |
| Tensilestrength | 120 MPa |
| Tensileelongation | 2.0% |
| Flexuralmodulus | 8500 MPa |
| Notchedizodimpactstrength | 60 J/m |
| Heatdeflectiontemperatureat1 8mpa | 200 °C |
| Waterabsorption | 0.07% |
| Moldingshrinkageflow | 0.2% |
| Moldingshrinkagecrossflow | 0.6% |
| Meltingpoint | 225 °C |
| Flameretardancy | UL94 V-0 |
As an accredited Toray Toraycon® PBT+GF30%-FR 1164G-30 T2 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Toray Toraycon® PBT+GF30%-FR 1164G-30 T2 is supplied in 25 kg moisture-proof bags, palletized for industrial handling and storage. |
| Container Loading (20′ FCL) | 20′ FCL dry container loaded with palletized 25 kg bags of Toray Toraycon® PBT+GF30%-FR 1164G-30 T2, shrink-wrapped and secured. |
| Shipping | Toray Toraycon® PBT+GF30%-FR 1164G-30 T2 is typically shipped as non-hazardous polymer pellets in sealed moisture-barrier bags or cartons. Protect from moisture, contamination, heat, and direct sunlight; store below 40°C. No special dangerous-goods classification is expected, but verify the SDS and local transport regulations before shipment. |
| Storage | Store Toray Toraycon® PBT+GF30%-FR 1164G-30 T2 in a cool, dry, well-ventilated area, away from direct sunlight, heat sources, and open flames. Keep it in the original sealed packaging to prevent moisture absorption and contamination. Avoid prolonged exposure to high humidity or elevated temperatures, and follow the manufacturer’s SDS and local regulations for safe handling and storage. |
| Shelf Life | Shelf life is typically 12 months in original unopened packaging, stored dry below 30°C, avoiding moisture and direct sunlight. |
Competitive Toray Toraycon® PBT+GF30%-FR 1164G-30 T2 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Toraycon® PBT+GF30%-FR 1164G-30 T2 is an injection-molding grade based on polybutylene terephthalate, reinforced with 30 % short glass fiber and formulated with a flame-retardant package. The model designation 1164G-30 identifies the polymer family, glass-fiber loading, and flame-retardant modification, while the T2 suffix is a manufacturing-version or package identifier. Published data for this specific configuration is limited, and therefore the numerical envelopes cited below are representative of the 30 wt% glass-reinforced flame-retardant PBT class rather than certified batch-specific values for the exact T2 suffix. The material is typically supplied as cylindrical or lenticular pellets and is processed on conventional reciprocating-screw injection molding machines with gravimetric or volumetric feeding.
Target application fields include electrical connectors, circuit-breaker internal frames, relay bases, power-distribution housings, motor brush holders, cooling-fan frames, and power-tool enclosures. The 30 % glass phase raises room-temperature tensile modulus into the 9,000–11,500 MPa range under ISO 527-2 and heat-deflection temperature under 1.80 MPa into the 195–215 °C range under ISO 75-2. This compares with unreinforced flame-retardant PBT, which typically shows a flexural modulus near 2,500–3,000 MPa. The trade-off is a reduction in elongation at break to the class-typical range of 2–4 % and an increase in anisotropic shrinkage driven by fiber orientation.
Compared with unfilled flame-retardant PBT, the glass-reinforced grade provides higher tensile strength, flexural modulus, and creep resistance but lower notched impact and higher melt viscosity. Compared with impact-modified FR PBT, the compound trades room-temperature toughness for stiffness and long-term dimensional stability. Compared with halogen-free FR PBT, the flame-retardant mechanism may differ in tracking resistance and corrosion behavior. A halogenated FR package can permit thin-wall UL 94 V-0 performance at lower loadings, but the comparative tracking index under IEC 60112 may fall to the 200–400 V range, whereas many halogen-free FR PBT grades reach 500–600 V. This is a decisive boundary in connectors exposed to condensation, dust, or surface contamination. Compared with mineral-filled PBT grades used for low-warpage covers, the 30 % short-glass product offers higher stiffness and strength but more pronounced differential shrinkage and warpage.
| Property | Test method | Representative range | Unit |
|---|---|---|---|
| Density | ISO 1183-1 | 1.60–1.70 | g/cm³ |
| Tensile strength at break | ISO 527-2 | 100–140 | MPa |
| Tensile modulus | ISO 527-2 | 9,000–11,500 | MPa |
| Flexural strength | ISO 178 | 160–210 | MPa |
| Flexural modulus | ISO 178 | 8,500–11,000 | MPa |
| Charpy notched impact, +23 °C | ISO 179-1/1eA | 6–10 | kJ/m² |
| Heat-distortion temperature, 1.80 MPa | ISO 75-2 | 195–215 | °C |
| Molding shrinkage, parallel/normal | ISO 294-4 | 0.2–0.5 / 0.7–1.0 | % |
Moisture control is the dominant processing constraint for this polyester compound. A dehumidifying hopper dryer with a dew point of −30 °C or lower should reduce pellet moisture to 0.02 % or less before melting. Pre-drying at 120–140 °C for 3–5 h is a typical industrial window. A barrel profile from 240 °C near the feed throat to 260–270 °C at the nozzle is used on abrasion-resistant screw and barrel sets, with mold temperatures held at 60–100 °C to balance crystallization rate and surface finish. In production-scale trials, mold temperatures below 60 °C can produce glass-rich surfaces and high internal orientation, while melt temperatures above 280 °C or residence times beyond 5 min can degrade the PBT matrix and cause black specks, silver streaks, and flame-retardant decomposition. Screw geometry should be a low-compression, abrasion-resistant configuration with a non-return valve rated for glass-filled materials and a barrel L/D ratio between 20:1 and 25:1.
On manufacturing lines with hot-runner systems, the compound should not be held at melt temperature for longer than the permitted residence time because the flame-retardant package can generate corrosive decomposition products. Tool steel selection should therefore consider possible corrosion when halogenated FR chemistry is present. Gas vents should be located at the fill end and along knit lines to reduce burn marks from volatile flame-retardant degradation. Shot weight should use 50–70 % of barrel capacity for stable residence-time control. Batch-to-batch variance can arise from glass-fiber length distribution and feed-moisture content; if pellets are not dried uniformly, hydrolysis reduces melt viscosity and part weight can drift during a molding campaign.
Under UL 94, the 30 % glass-reinforced flame-retardant PBT class is typically rated V-0 at thicknesses of 0.8 mm or greater, but the actual rating depends on colorant, regrind fraction, and section thickness. For molded connectors, comparative tracking index under IEC 60112 is a decisive selection parameter. A value below 250 V restricts use in high-voltage creepage paths, whereas a value above 400 V is generally preferred for connectors spaced according to IEC 60664-1. Published data for the T2 version is limited; end users should request batch-specific CTI data when the part operates above 150 V with possible condensation. Relative thermal index values for GF30 PBT FR are commonly reported in the 130–140 °C range for electrical properties, with mechanical-with-impact values often 10–20 °C lower; these values require UL Yellow Card confirmation for the specific grade.
| Parameter | Range | Unit |
|---|---|---|
| Pre-drying temperature | 120–140 | °C |
| Pre-drying time | 3–5 | h |
| Maximum pellet moisture | 0.02 | % |
| Melt temperature | 240–270 | °C |
| Mold temperature | 60–100 | °C |
| Nozzle temperature | 250–270 | °C |
| Back pressure | 5–10 | MPa |
| Maximum residence time | 5 | min |
Connector and circuit-breaker applications place simultaneous demands on tracking resistance, dimensional stability, and stiffness. The 30 % glass loading provides the rigidity needed to maintain contact alignment under mechanical load, but anisotropy from fiber orientation can cause differential shrinkage of 0.2–0.5 % in the flow direction and 0.7–1.0 % transverse to flow under ISO 294-4. Tooling should therefore position gates to orient the glass field in the direction of primary mechanical stress and to avoid knit lines in thin latch arms. In production-scale mold trials, parts gated at a single edge may exhibit bowing due to asymmetric shrinkage; a film gate or multiple gates may be required for flat housings. The material class is also used in motor end caps and power-tool housings where UL 94 V-0 compliance at 0.8 mm and resistance to oils and greases are required. Short-glass PBT after injection molding commonly shows a number-average fiber length near 200–400 µm, and final mechanical properties therefore depend on screw design, back pressure, and gate geometry.
If an electrical enclosure is exposed to relative-humidity swings from 20 % to 80 %, a 30 % glass-reinforced PBT FR absorbs roughly 0.2–0.3 % moisture at 23 °C, whereas a comparable PA66 GF30 FR absorbs 1.5–2.5 %. The lower moisture uptake reduces dimensional change and stabilizes dielectric strength in connector strips and terminal blocks. However, dry-as-molded heat-deflection temperature under 1.80 MPa is lower for PBT-GF30 FR than for PA66-GF30 FR; PA66-GF30 FR can exceed 240 °C dry, but after moisture conditioning the HDT falls substantially. For structural loads above 180 °C, PBT is not appropriate because the PBT melting point is near 225 °C. The 1164G-30 T2 designation therefore fits applications in which the thermal ceiling is below 150 °C and moisture-driven dimensional variation must be minimized. In addition, PBT-GF30 FR generally offers faster crystallization and shorter cycle time than PC/PBT FR blends, but it shows lower low-temperature impact toughness and higher notch sensitivity.
Operational boundaries include avoidance of prolonged contact with hot water, steam, strong acids, and alkaline media above 60 °C, because PBT undergoes hydrolytic chain scission at a rate that increases with temperature and pH. The compound is not recommended for applications requiring sustained load in the presence of amines or strong alkalis. Flame-retardant additives may interact with metal contacts under high-humidity DC bias, so electrochemical migration testing should be performed under an accepted industry method, such as IPC-TM-650 method 2.6.14, where applicable. Regrind use above 25 % is not typical for thin-wall UL 94 V-0 parts because flame-retardant distribution and mechanical properties drift with repeated heat history.