| HS Code | 453917 |
| Polymer Type | Polybutylene terephthalate (PBT) |
| Glass Fiber Content | 15% |
| Flame Retardant System | Non-halogen flame retardant |
| Density | 1.53 g/cm³ |
| Tensile Strength | 95 MPa |
| Elongation At Break | 2.0% |
| Flexural Modulus | 6200 MPa |
| Charpy Notched Impact Strength | 4 kJ/m² |
| Heat Deflection Temperature At 1 82 Mpa | 195 °C |
| Melting Point | 225 °C |
| Ul 94 Flammability Rating | V-0 |
| Molding Shrinkage | 0.4-0.8% |
| Water Absorption At 23 C 24 H | 0.06% |
| Volume Resistivity | 1×10^16 Ω·cm |
As an accredited Toray Toraycon® PBT+GF15%-FR-NF EC44G-15 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Toray Toraycon® PBT+GF15%-FR-NF EC44G-15 is supplied in 25 kg moisture-barrier bags, 40 bags per pallet (1,000 kg). |
| Container Loading (20′ FCL) | 20′ FCL container loaded with Toray Toraycon® PBT+GF15%-FR-NF EC44G-15 in moisture-proof bags on pallets, securely braced for export shipment. |
| Shipping | Toray Toraycon® PBT+GF15%-FR-NF EC44G-15 is shipped as solid resin pellets in moisture-barrier bags or octabins, palletized and dry. Normally not regulated as dangerous goods; follow local transport rules and SDS. Store away from heat, sunlight, and moisture. |
| Storage | Store Toray Toraycon® PBT+GF15%-FR-NF EC44G-15 in a cool, dry, well-ventilated area, away from direct sunlight, heat, ignition sources, and moisture. Keep original containers tightly closed and palletized. Avoid dust generation, static buildup, and contamination; use clean, dry handling equipment. Do not store near strong oxidizers. Follow first-in, first-out stock rotation and applicable local regulations. |
| Shelf Life | Typically 12 months when stored cool, dry, and in original unopened packaging, away from moisture and sunlight. |
Competitive Toray Toraycon® PBT+GF15%-FR-NF EC44G-15 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Toray Toraycon® PBT+GF15%-FR-NF EC44G-15 is a polybutylene terephthalate injection-molding compound containing a nominal 15% by weight glass fiber reinforcement and a non-fluorine flame-retardant system. The grade is positioned within the Toraycon FR-NF series for electrical, electronic, and industrial control components that require UL 94 V-0 flammability performance, reduced halogen content, and dimensional stability under mechanical load. Published data for this specific EC44G-15 configuration is limited; the numerical ranges given in this technical introduction are therefore representative of the PBT-GF15 FR-NF class and must be confirmed against the lot-specific certificate of analysis from Toray. The product is supplied as pellets for screw plasticizing injection molding. It differs from unfilled PBT FR-NF by higher flexural modulus and lower flow length, and it differs from brominated PBT-GF15 FR by its non-fluorine combustion gas profile and different melt viscosity response at low shear.
The primary substitution constraint is the rheological difference associated with the non-fluorine flame-retardant package. In phosphorus-based and nitrogen-synergist FR systems, melt viscosity at low shear is often higher than in brominated systems at equivalent glass loading. This increases pressure loss through runner systems and can cause short shots in tools designed for brominated PBT-GF15 grades when identical machine settings are used. The melt temperature should be maintained in the 240–270 °C band, with the nozzle temperature measured by an inserted thermocouple and controlled within ±5 °C. Above 270 °C, phosphorus-based degradation products can generate plate-out on mold vents. Below 240 °C, glass fiber dispersion and thin-wall filling below 1.0 mm may become insufficient in multi-cavity tools.
Drying prior to molding EC44G-15 is mandatory because PBT undergoes hydrolysis at processing temperatures when moisture is present. Desiccant-dryer settings of 120–130 °C for 4–6 h reduce moisture to below 0.02% as determined by Karl Fischer titration or a calibrated moisture analyzer. Hopper residence time should not exceed 4 h when the dryer dew point rises above −30 °C. In production-scale equipment with screw L/D ratios from 20:1 to 24:1, a medium-compression screw with a non-return valve is typical. Barrel temperature profiles are set with a flat-to-reverse profile to prevent excessive shear heating: rear zone 230–245 °C, middle zone 245–255 °C, nozzle 250–260 °C. Back pressure below 10 MPa preserves glass fiber length and limits volatilization of the FR package. Cushion control of 2–5 mm avoids prolonged residence time in the barrel.
Glass fiber at 15% loading creates measurable shrinkage anisotropy. Typical in-flow shrinkage is 0.35–0.55% and cross-flow shrinkage is 0.80–1.10% on plaques molded according to ISO 294-4; weld line strength and warpage depend on gate location and fiber orientation. Mold temperature is set between 60 °C and 90 °C. The lower band shortens cycle time but lowers crystallinity and increases post-mold dimensional movement. The upper band stabilizes crystallinity and reduces warpage in connectors with terminal pitch below 2.54 mm. Because PBT crystallizes rapidly, the minimum mold temperature can be lower than that for PET blends, but the non-fluorine FR filler may slow crystallization slightly. Holding pressure decay should be profiled over 2–5 s to compensate for shrinkage. Wall sections from 0.8 mm to 3.0 mm should be made as uniform as possible to avoid sink marks and differential fiber orientation.
Electrical performance of EC44G-15 is routinely characterized by comparative tracking index under IEC 60112, dielectric strength under IEC 60243-1, and glow-wire flammability under IEC 60695-2-11. Published data for the exact EC44G-15 grade is limited; the FR-NF PBT-GF15 class typically achieves a CTI value in the 250–400 V range, a dielectric strength of 20–25 kV/mm on 2.0 mm plaques, and UL 94 V-0 certification at 0.75 mm or 1.5 mm depending on colorant loading. Black and dark-gray formulations may show lower CTI than natural resin because carbon black introduces surface leakage paths. In connector applications, insulation resistance after humidity aging at 85 °C and 85% RH for 500 h should be verified by the end user according to IEC 60068-2-78. Because the grade is designated non-fluorine, dripping resistance under UL 94 is achieved through the char-promoting mechanism of the FR package rather than through PTFE fibril melt-flow suppression. Published data for this specific configuration is limited; end-user verification is recommended for parts with wall thickness below 0.75 mm.
Replacement of GF30 by EC44G-15 is not a direct modulus-for-modulus exchange. Flexural modulus decreases from roughly 8000–10000 MPa to 5500–7000 MPa, and the lower glass content improves flow length and surface finish but reduces collapse resistance in snap-fit latches. Tensile strength at break falls to approximately 90–120 MPa as measured under ISO 527-1/-2. In connector bodies with living hinges or snap arms, the lower fiber loading lowers notch sensitivity but requires redesign of load-bearing screw bosses. In metal-insert molding, differential thermal contraction around brass or phosphor-bronze pins must be recalculated because the coefficient of linear thermal expansion parallel to flow increases relative to GF30. Published data for this specific substitution is limited; weld-line tensile testing under ISO 527-1/-2 should be performed on components with knit lines located in load-bearing regions.
Thermal performance under sustained load is a selection boundary for EC44G-15 in electrical enclosures. The heat deflection temperature for the FR-NF PBT-GF15 class is typically 195–210 °C at 1.80 MPa by ISO 75-1/-2 method A. Continuous use temperature is often limited to 120–140 °C for thin-wall PBT compounds when contact with hot terminals or current-carrying busbars creates localized temperatures above the glass transition. Above 150 °C, long-term thermal oxidative aging of PBT can cause surface chalking and embrittlement. Creep in glass-reinforced PBT at elevated temperature may loosen terminal fasteners; molded bosses should use metallic threaded inserts rather than self-tapping screws under high normal loads.
Values in the table below are class-representative ranges from public PBT compound data. EC44G-15 lot-specific values may differ.
| Property / test method | EC44G-15 class | Brominated PBT-GF15 FR | Unfilled PBT FR-NF | PBT-GF30 FR halogenated |
|---|---|---|---|---|
| Density, ISO 1183-1 | 1.45–1.55 g/cm³ | 1.45–1.55 g/cm³ | 1.30–1.35 g/cm³ | 1.55–1.65 g/cm³ |
| Flexural modulus, ISO 178 | 5500–7000 MPa | 6000–7500 MPa | 2400–2800 MPa | 8000–10000 MPa |
| Tensile strength, ISO 527-1/-2 | 90–120 MPa | 95–125 MPa | 55–70 MPa | 110–140 MPa |
| Charpy notched, ISO 179-1/1eA | 4–6 kJ/m² | 4–6 kJ/m² | 3–5 kJ/m² | 6–9 kJ/m² |
| HDT/A, ISO 75-1/-2 | 195–210 °C | 195–210 °C | 110–130 °C | 200–215 °C |
| UL 94 at 0.75 mm | V-0 | V-0 | V-0 | V-0 |
| FR chemistry | Non-fluorine phosphorus/nitrogen | Brominated system | Non-fluorine phosphorus/nitrogen | Brominated system |
Regulatory and end-use compliance for EC44G-15 requires the lot-specific documentation shown in the table below. Because colorants and regrind content can shift flammability and electrical values, qualification should be repeated after any masterbatch change above 0.5% by weight.
| Requirement | Reference method / regulation | Typical value / status | Verification boundary |
|---|---|---|---|
| Flame class | UL 94 | V-0 at 0.75 mm or 1.5 mm | Color and thickness dependent |
| Glow wire flammability index | IEC 60695-2-12 | 850–960 °C | Part geometry dependent |
| Comparative tracking index | IEC 60112 | 250–400 V | Colorant sensitive |
| Dielectric strength | IEC 60243-1 | 20–25 kV/mm at 2.0 mm | Thickness dependent |
| Residual moisture prior to molding | ISO 15512 | <0.02% | Desiccant drying required |
| RoHS restricted substances | RoHS Directive 2011/65/EU | Certificate of compliance required per lot | Raw material control |
Regulatory status is a core differentiator for EC44G-15. The grade is expected to be assessed under EU RoHS Directive 2011/65/EU and Commission Delegated Directive (EU) 2015/863 for restricted phthalates, but the manufacturer’s certificate of compliance must be consulted for each lot. Non-fluorine flame-retardant formulations do not rely on decabromodiphenyl ethane or tetrabromobisphenol A; therefore documentation for bromine content under IEC 61249-2-21 is often simplified. The absence of fluorine-containing anti-drip does not automatically guarantee absence of perfluorooctanoic acid or perfluorooctanesulfonic acid; nevertheless, the FR-NF designation is intended to avoid intentionally added PFAS. For REACH Regulation (EC) No 1907/2006, the grade should be screened against the Candidate List of substances of very high concern. Electrical applications may require glow wire ignition temperature GWIT and glow wire flammability index GWFI at 850 °C or 960 °C according to IEC 60695-2-12 and IEC 60695-2-13; design verification testing is recommended due to wall thickness and colorant effects.
The melt volume flow rate for the FR-NF GF15 class typically falls between 10 and 20 cm³/10 min at 250 °C with a 2.16 kg load under ISO 1133-1:2022. The addition of 15% glass fiber produces shear-thinning behavior; at injection molding shear rates from 500 s−1 to 5000 s−1, apparent viscosity may be lower than the MVR value alone suggests. Specific MVR values for EC44G-15 vary with recycled content and colorant package. Process technicians should not compare EC44G-15 to a brominated grade solely on MVR because the non-fluorine FR chemistry can yield similar MVR but different spiral-flow length in thin-wall tools with flow length-to-thickness ratios above 200:1. Tool qualification should use instrumented mold trials on a 60–120 t injection molding machine rather than laboratory MVR as the sole acceptance criterion.
On a 100 t hydraulic injection molding machine with a screw diameter of 32 mm and L/D 21:1, lot-to-lot variation in peak injection pressure of 3–7 MPa is not uncommon for FR-NF PBT-GF15 grades due to variation in glass fiber length distribution after compounding. Process alarms on injection pressure should be set within ±10% of a qualified reference lot. The nozzle should be a shut-off type and the barrel should remain filled between cycles to minimize oxidation of the flame-retardant package. Purging should use a medium-viscosity PET or PBT purging compound; prolonged use of polyolefin purge material can create incompatible layers and black specks.
Assembly of EC44G-15 parts by ultrasonic welding requires controlled amplitude and trigger force because the glass fiber content reduces energy director collapse and can create glass-rich weld flash. Typical parameters for this grade class are 20–30 kHz frequency, 30–60 µm amplitude, and 0.2–0.5 s weld time; wall thickness at the joint should be 1.0–2.0 mm. Laser transmission welding at 980 nm is possible only when the near-infrared absorber content in the upper part is sufficient and the base part contains carbon black. Published data for this specific configuration is limited; weld destructive testing under ISO 527-1/-2 should be performed on welded specimens.
Regrind use in EC44G-15 must be limited to 20% by weight for UL-listed components unless the certification file includes a higher percentage. Repeated regrind cycles reduce fiber length and increase melt flow variation; MVR can increase by 2–5 cm³/10 min after two extrusion cycles. The flame-retardant package remains active through limited reprocessing, but the non-fluorine system may show different color retention than brominated systems. In-house regrind should be dried to below 0.02% moisture and blended with virgin pellets at rate-controlled dosing.
Surface finish of EC44G-15 is glass-fiber dependent; exposed fiber ends create a matte surface and reduce paint adhesion unless the surface is flame-modulated or plasma treated. For black grades, visual defects are less visible, but white or gray grades require high mold polish and appropriate gate vestige control. Texturing depths of 0.02–0.05 mm are typical for electrical housings; mold release agents should be avoided because they can interfere with subsequent ultrasonic welding or pad printing.
Chemical resistance of EC44G-15 follows PBT behavior: it has good resistance to aliphatic hydrocarbons, gasoline, and many industrial oils at room temperature, but hot alkaline solutions, strong acids, and long-term contact with automotive brake fluid can cause surface etching and stress cracking. In service, parts exposed to engine coolant above 80 °C or to hot water at 95 °C should be validated for hydrolysis resistance. The non-fluorine FR package may have different extractable ion content than halogenated systems, so the user should test for electrochemical migration under IPC-TM-650 or IEC 60068-2-20.
The material is used in power distribution and industrial control components where dimensional stability under heat and flammability certification are required. Typical parts include relay bases, terminal blocks, circuit-breaker internal frames, motor brush holders, sensor housings, and insulating brackets. In motor brush holders, the combination of 15% glass fiber provides creep resistance at commutator temperatures from 120 °C to 140 °C, while the non-fluorine FR package reduces the risk of contact corrosion in humid environments compared with halogenated systems if acidic combustion products are avoided. In terminal blocks, EC44G-15 permits stringers to be molded with flatness tolerances below 0.05 mm over 50 mm when mold temperature is held at 80 °C. For optocoupler housings and light-guiding parts, the glass fiber content produces a white or light-gray surface; when an opaque black colorant is compounded, near-infrared transmission after laser welding may drop below the threshold for process repeatability. Users should verify weld line strength and laser welding compatibility by trial on target part geometry.