| HS Code | 564710 |
| Materialtype | PBT with 15% glass fiber and flame retardant |
| Glassfibercontent | 15% |
| Flameretardant | Yes |
| Density | 1.58 g/cm³ |
| Tensilestrength | 95 MPa |
| Elongationatbreak | 2.0% |
| Flexuralmodulus | 5700 MPa |
| Hdt 1 82mpa | 200 °C |
| Ul94flammability | V-0 at 0.75 mm |
| Waterabsorption | 0.07% |
| Moldingshrinkage | 0.4-0.8% |
| Volumeresistivity | 1e16 Ω·cm |
| Dielectricstrength | 20 kV/mm |
| Meltingpoint | 224 °C |
As an accredited Toray Toraycon® PBT+GF15%-FR 1164G-15 T2 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Packaged in 25 kg net moisture-proof paper sacks, 40 bags per pallet, for Toray Toraycon® PBT+GF15%-FR 1164G-15 T2. |
| Container Loading (20′ FCL) | Container Loading (20′ FCL): Toray Toraycon® PBT+GF15%-FR 1164G-15 T2 in palletized bags, loaded into one 20-foot FCL container. |
| Shipping | Toray Toraycon® PBT+GF15%-FR 1164G-15 T2 is shipped as dry, sealed thermoplastic pellets in moisture-barrier bags or containers at ambient temperature. Protect from moisture, contamination, and physical damage. Transport according to the current SDS and applicable local, national, and international regulations. |
| Storage | Store in a cool, dry, well-ventilated area away from direct sunlight, heat, ignition sources, and strong oxidizers. Keep containers tightly closed to prevent moisture absorption and contamination. Avoid humid conditions; dry material before processing per supplier recommendations. Follow the SDS and local regulations for safe handling and storage. |
| Shelf Life | Shelf life is 12 months from manufacture when stored in original unopened packaging at room temperature, dry conditions, away from direct sunlight. |
Competitive Toray Toraycon® PBT+GF15%-FR 1164G-15 T2 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Polybutylene terephthalate homopolymer is compounded with 15 wt% short glass fibre and a halogenated flame-retardant/antimony trioxide synergist system in Toray Toraycon® PBT+GF15%-FR 1164G-15 T2. The grade is supplied as cylindrical pellets for injection moulding and is typically specified in electrical housings, relay sockets, connector bodies, motor brush holders, appliance power-entry modules, and miniature circuit-breaker cases. Melt compounding is performed on a twin-screw extruder with side feeding of glass fibre; the fibre length distribution after compounding is controlled to balance stiffness retention against surface appearance and mould abrasion. Test specimens for the manufacturer’s data sheet are injection-moulded under ISO 294-1 and conditioned according to ISO 291 23/50. The T2 suffix identifies a Toray internal viscosity and additive modulation within the 1164G-15 family; melt volume-flow rate under ISO 1133-1 is typically reported in the 15–25 cm³/10 min range at 250 °C/2.16 kg, but the current datasheet value should be used for nozzle and gate sizing.
Manufacturer-published typical values include density in the range 1.54–1.56 g/cm³ under ISO 1183, tensile strength of 95–110 MPa under ISO 527-1/2, flexural modulus of 6,000–7,000 MPa under ISO 178, and notched Charpy impact energy of 5–6 kJ/m² under ISO 179/1eA. Heat deflection temperature at 1.82 MPa under ISO 75-1/2 is typically reported near 200–210 °C. These are typical values from a production melt, not specification minima. Lot-to-lot verification against the current Toray technical data sheet is required for safety-critical dimensions, especially when a colour concentrate or regrind fraction is introduced because both can alter flammability, impact, and tracking behaviour.
Compared with unfilled flame-retarded PBT grades, the 15 wt% glass fibre loading reduces mould shrinkage and increases flexural modulus at the cost of lower notched impact toughness and reduced flow length. The material is therefore selected when components require higher stiffness and reduced warpage in thin walls, but when a 30 wt% glass-reinforced FR-PBT would produce excessive fibre abrasion in multi-cavity tools and difficult filling through long gates. Specific processing boundaries are detailed in the following sections.
Comparative tensile and shrinkage data show that the 15 wt% loading occupies an intermediate position between unreinforced flame-retarded PBT and 30 wt% glass-reinforced FR-PBT. The glass fibres restrict crystallisation-induced contraction perpendicular to flow, but the lower fibre fraction preserves more melt mobility and surface uniformity than a 30 wt% system. The table below summarises typical comparative ranges from manufacturer data and general PBT compound literature.
| Property and test method | Toraycon® 1164G-15 T2 | Unreinforced PBT-FR | PBT-GF30-FR |
|---|---|---|---|
| Density (ISO 1183) | 1.54–1.56 g/cm³ | 1.44–1.48 g/cm³ | 1.64–1.68 g/cm³ |
| Flexural modulus (ISO 178) | 6,000–7,000 MPa | 2,600–3,000 MPa | 8,500–9,500 MPa |
| Notched Charpy impact (ISO 179/1eA) | 5–6 kJ/m² | 3–5 kJ/m² | 7–9 kJ/m² |
| HDT at 1.82 MPa (ISO 75-1/2) | 200–210 °C | 60–80 °C | 200–210 °C |
| Mould shrinkage, parallel/normal (ISO 294-4) | 0.8–1.2 % | 1.5–2.0 % | 0.3–0.6 % |
The shrinkage differential between flow direction and transverse direction remains lower than unfilled PBT because the oriented glass fibres restrict expansive contraction. Weld-line strength is not improved by fibre addition; knitted weld lines in a 15 wt% glass-filled FR-PBT can retain less than 60 % of bulk tensile strength when a standard ASTM D638-type tensile bar is gated from two ends. Fibre orientation at the weld line is predominantly parallel to the melt front and reduces stress transfer across the plane. Sequential valve-gate sequencing, relocation of the gate away from snap-fit features, or the use of overflow tabs is required when weld lines are unavoidable.
Polyamide 66 reinforced with 15 wt% glass fibre and a flame-retardant package is an alternative in electrical connectors, but its moisture absorption under 23 °C/50 % RH is typically 1.8–2.5 wt%, whereas PBT absorbs less than 0.1 wt% under the same equilibrium conditions when measured by ISO 62. In a humid tropical environment at 30 °C/85 % RH, a PA66 connector housing can expand by 0.4–0.6 %, while a PBT-GF15 component remains below 0.1 % dimensional change. Terminal insertion forces in PBT housings are therefore more stable across seasonal humidity cycles, and the risk of corrosion of embedded brass terminals is reduced because the polyester matrix does not contribute caprolactam or glycol plasticiser migration.
The trade-off is thermal ageing resistance. Published data for this specific configuration in hot-air ageing above 130 °C is limited, but general PBT chemistry indicates that ester linkages are more susceptible to thermo-oxidative chain scission than polyamide 66. Continuous-use claims above 125 °C in air must be verified by end-product testing under the relevant IEC 60216 thermal endurance programme rather than inferred from short-term heat deflection temperature.
Residual moisture beyond 0.02 wt% hydrolyzes the ester linkage during melt processing. The result on a production floor includes reduced melt viscosity, increased flash at the parting line, and intermittent brittleness in thin snap-fit sections. Desiccant drying at 120–130 °C for 4–6 h with air dew point below -30 °C is the standard industrial practice from sealed bags. If open bags have been exposed to 60 % RH for more than 8 h, drying should be extended to 6–8 h. Moisture measurement by ISO 15512 method B using Karl Fischer coulometric detection is recommended for lots entering electrical safety parts or ultrasonic-welded assemblies.
Thermal degradation in the barrel begins to dominate above 270 °C or when cumulative residence time exceeds 10 min. The flame-retardant system releases acidic decomposition products; carbon deposits and black specks in white or translucent mouldings are the visual indicator. These deposits can then detach into the melt stream and block submarine gates below 1.0 mm. Shut-down procedure should include purging with a melt-stable polyester or polyolefin. PVC and acetal should not be purged through the same barrel because cross-contamination can generate gaseous decomposition products and corrode hot-runner components.
In a reciprocating-screw injection machine with a general-purpose thermoplastic screw of L/D 18:1 to 22:1 and a compression ratio near 2.0:1 to 2.5:1, the barrel profile is typically set from 230 °C at the rear zone to 250–260 °C at the nozzle. Mould temperature is held at 60–80 °C. Back pressure is maintained below 0.5–1.0 MPa to preserve glass fibre length, and screw rotational speed is limited to 50–80 m/min peripheral speed. In multi-cavity hot-runner tools, flow balancing is critical; shear-induced melt temperature differences across the manifold can exceed 10 °C and produce differential crystallinity, gloss variation, and inconsistent post-mould shrinkage. Gate freeze time in a tunnel or submarine gate of 1.0 mm diameter is short; hold pressure should be set by gate seal studies on the actual tool rather than by generic process sheets.
The grade is typically classified UL 94 V-0 at 0.8 mm using the 125 mm × 13 mm bar geometry of IEC 60695-11-10. That classification is a material property under defined bar thickness and conditioning; it does not automatically cover thinner walls, complex flow-front interactions, or coloured production parts. At wall thickness below 0.8 mm, published data for this specific configuration is limited, and flame classification must be verified on the moulded end-part because thinner cross-sections can reduce char formation and alter dripping behaviour. The same limitation applies when mould temperature is below 60 °C; reduced crystallinity can shift UL 94 performance even if the datasheet classification remains valid under optimised conditions.
Comparative tracking index under IEC 60112 is commonly reported in the 200–250 V class for halogenated FR-PBT grades. This is adequate for many indoor appliance connectors but not for severe outdoor pollution degree 4 under IEC 60664-1, where dust plus condensation produces continuous conductive films. A higher-CTI grade or a different material family should be selected when creepage distances cannot be enlarged. Glow-wire tests under IEC 60695-2-12 and IEC 60695-2-13 must be run on the actual wall thickness and colour, because colour concentrates can reduce glow-wire ignition performance disproportionately.
| Characteristic | Test standard | Typical classification or range | Verification note |
|---|---|---|---|
| Flammability | UL 94 / IEC 60695-11-10 | V-0 at 0.8 mm | End-part thickness is decisive |
| Glow-wire flammability index | IEC 60695-2-12 | GWFI 960 °C at 1.0 mm | Current test certificate required |
| Comparative tracking index | IEC 60112 | 200–250 V | Pollution degree dependent |
| Dielectric strength | IEC 60243-1 | 18–22 kV/mm at 1.0 mm | 50 Hz, short-time test |
| Moisture absorption | ISO 62 | < 0.1 wt% after 24 h water | Not valid for hot-water immersion |
Where components are supplied into household appliances tested under IEC 60335-1, the material classification alone is not sufficient. The moulding grade must be combined with part-specific thickness, colour, and regrind validation. A V-0 datasheet classification is a material property under standard bar geometry; it does not replace end-product glow-wire, tracking, and flame testing on the finished insulator assembly.