Products

Solvay Toolcoat S/T-02 S/A Adhesive tape

    • Product Name: Solvay Toolcoat S/T-02 S/A Adhesive tape
    • Factroy Site: Yinchuan, Ningxia, China
    • Price Inquiry: sales8@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 413463
    Productname Solvay Toolcoat S/T-02 S/A Adhesive Tape
    Manufacturer Solvay
    Backingmaterial PTFE (polytetrafluoroethylene) film
    Adhesivetype Silicone
    Backingthickness 0.002 in (0.05 mm)
    Totalthickness 0.0035 in (0.089 mm)
    Color Brown
    Temperaturerange -100°F to 500°F (-73°C to 260°C)
    Tensilestrength 10 lb/in (1.75 N/cm)
    Elongation 100%
    Peeladhesion 25 oz/in (2.7 N/cm)
    Dielectricstrength 500 V/mil (19.7 kV/mm)
    Chemicalresistance Excellent
    Frictioncoefficient Low
    Releaseproperties Excellent
    Standardwidth 1 in (25.4 mm)
    Standardlength 36 yd (32.9 m)

    As an accredited Solvay Toolcoat S/T-02 S/A Adhesive tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Solvay Toolcoat S/T-02 S/A Adhesive tape is packaged as one roll per sealed, labeled protective box for safe handling.
    Container Loading (20′ FCL) 20′ FCL container loading: chemical Solvay Toolcoat S/T-02 S/A adhesive tape, palletized, shrink-wrapped, dunnaged, kept dry, upright, away from heat.
    Shipping Solvay Toolcoat S/T-02 S/A Adhesive tape: non-hazardous adhesive tape. Not regulated for transport by DOT, IATA, or IMDG. Ship in original sealed packaging at ambient temperature, away from moisture, heat, and ignition sources. No UN number, hazard class, packing group, or special labels required.
    Storage Store Solvay Toolcoat S/T-02 S/A Adhesive tape in a cool, dry, well-ventilated area, away from direct sunlight, heat, sparks, and moisture. Keep containers/rolls sealed in original packaging until use. Maintain recommended temperature, typically 15–25°C, and observe shelf-life/expiry. Protect from freezing if specified. Rotate stock and follow SDS/technical datasheet. Do not store near incompatible chemicals, food, or drinking water. Use first-in, first-out.
    Shelf Life Shelf life is 12 months from date of manufacture when stored unopened at 23°C (73°F) and 50% relative humidity.
    Application of Solvay Toolcoat S/T-02 S/A Adhesive tape

    When a machined Invar 36 tool face is prepared for autoclave-cured aerospace laminates, the replacement of a sprayed fluoropolymer release coating with Solvay Toolcoat S/T-02 S/A self-adhesive silicone tape is executed at a surface roughness of 0.8–1.2 µm Ra (ISO 4287:1997) to ensure mechanical keying without entrapped air. The application ratio is fixed at one continuous ply of 0.35–0.50 mm thickness and 1.0 m width, yielding a nominal silicone coverage of 1.1–1.5 kg/m²; splice joints are lapped 25 mm minimum and shifted out of radii below 12 mm. Before first cure, the tape is consolidated with a pneumatic rubber-covered roller at 0.2–0.4 MPa contact pressure under 0.85 bar vacuum for 60 min. Autoclave cure of epoxy prepreg at 177 ± 5 °C and 0.62–0.69 MPa external pressure can drive low-molecular-weight siloxane species into the tool surface, so incoming tape is screened for volatiles by ASTM D4525-13e1 and for peel adhesion by ASTM D3330/D3330M-04 Test Method A, with acceptance set at 6.5–9.5 N/25 mm on an abraded aluminum panel. Production-scale failure modes recorded on a 2.0 m × 1.5 m autoclave platen include edge lifting at tool features with radius below 4 mm and blistering caused by residual solvent trapped under the tape. Compliance is maintained under AS9100D clause 8.5.1 for process control, REACH Article 33(1) SVHC communication, and RoHS Directive 2011/65/EU Annex II for supplied homogeneous materials. Terminal autoclave-cured woven carbon/epoxy wing ribs, spar webs, and nacelle skins requiring a class A tool-side finish are produced from this tool face.

    What limits out-of-autoclave cure when the tool face is a renewable silicone tape?

    Out-of-autoclave carbon fiber/epoxy prepreg systems cure at 85–120 °C under 0.80–0.95 bar vacuum, a regime in which the release surface must remain dimensionally stable while allowing volatile evacuation. For Solvay Toolcoat S/T-02 S/A used as a temporary tool face on an aluminum mandrel 1.8 m long, the application ratio is controlled by a transfer adhesive coat weight of 25–40 g/m² and a tape thickness of 0.15–0.25 mm, giving a wet coverage of approximately 0.6–0.8 kg/m². The tape is applied in a cleanroom at 21–25 °C and 40–55% relative humidity to avoid entrapped moisture; splice overlap is 30 mm and the outer edges are sealed with a 12 mm wide silicone flash tape. During cure, residual solvents and siloxane volatiles migrate to the vacuum port, and the main rejection mode is microvoiding at the tool-side surface when the vacuum pump cannot sustain 0.85 bar below atmosphere, typically because of bag bridging at stringer intersections. The parts produced are out-of-autoclave carbon fiber-reinforced epoxy fuselage frame clips and stringer termini, where process controls are aligned with AS9100D clause 8.5.1 and mechanical test panels are checked by ASTM D1002-10 for lap shear and ASTM D3359-17 Test Method B for coating adhesion. A compliance matrix for this scenario is shown below.

    Standard designationTest or audit requirementParameterAcceptance window
    AS9100D clause 8.5.1Production process control auditTool face tape installation recordBatch traceability retained 10 years
    ASTM D3330/D3330M-04 Test Method APeel adhesion on abraded aluminumPeel force6.5–9.5 N/25 mm
    ASTM D3359-17 Test Method BCross-cut tape adhesionTool-side coating removalClassification 4B minimum
    ASTM D4525-13e1Volatile contentMass loss at 100 °C≤0.5%
    REACH Article 33(1)SVHC communicationDeclarable substance0.1 wt% threshold
    RoHS Directive 2011/65/EU Annex IIHomogeneous material restrictionPb, Hg, Cr(VI), PBB, PBDE≤0.1 wt%; Cd ≤0.01 wt%

    Wind blade shell tooling and vacuum infusion release interfaces

    The dominant failure mode on large wind blade molds is not cure temperature but vacuum leakage at the flange release boundary during epoxy infusion at 22–35 °C, where a continuous silicone tape surface prevents wet resin from bonding the mold flange to the vacuum bag or the shell skin. On a 45 m blade shell mold, Solvay Toolcoat S/T-02 S/A is installed along the flange as 50 mm wide strips with 20 mm overlap, producing a release coverage of approximately 0.45 kg/m²; the tape is burnished at 0.3–0.5 MPa with a roller and inspected under 0.95 bar vacuum for leak-down below 0.80 bar over 10 min. The infusion process uses a low-viscosity epoxy resin system at 25 °C mixed in a 100 kg batch and degassed for 15 min under 0.90 bar vacuum before injection through spiral runners at a flow front of 0.15–0.30 m/min. The tape is not exposed to autoclave compaction, but it must tolerate the exothermic peak of 55–70 °C in thick spar cap regions and the continuous pressure of 0.10 MPa from the vacuum bag. Terminal products are wind turbine blade shell skins, spar caps, and shear webs produced to IEC 61400-5:2020 material and process qualifications, with adhesion of the release tape checked by ASTM D3330/D3330M-04 Test Method A and the underlying substrate by ASTM D3359-17 Test Method B. Published data for this specific product on a 45 m blade mold is limited, so incoming batch trials at the mold flange are required before series production.

    For a high-volume resin transfer molding cell producing carbon fiber-reinforced epoxy B-pillar reinforcements, the steel tool is heated to 120 °C and injected at 8–12 bar internal pressure, conditions that require the release tape to resist both hydraulic wash-out at the pinch line and cyclic thermal oxidation. Solvay Toolcoat S/T-02 S/A is die-cut to the outer mold perimeter at a thickness of 0.25 mm and a coverage of 1.2 kg/m²; 30 mm splices are positioned only on flat seal planes, never across a shear edge with radius below 6 mm. The preforming stage stacks dry unidirectional carbon fiber plies at 0°/90°/±45° and binds them with 2.5 wt% thermoplastic veil before the stack is transferred to the preheated tool. After mold close at 15–20 kN per meter seal line, the resin front is maintained at 1.5–2.0 m/min until the cavity is filled, and the tape releases the cured part at a demolding load below 1.5 kN per meter. Process controls meet IATF 16949:2016 clause 8.6.4 for product release and ASTM D5868-01(2014) for fiber-matrix adhesion, while the silicone tape itself is tested by ASTM D2240-15e1 for Shore A durometer and ASTM D412-16 for tensile strength. The terminal products are CFRP B-pillar reinforcements, transmission tunnel stiffeners, and battery tray corner inserts for electric vehicle platforms.

    When compression molding of carbon fiber SMC demands a release boundary that survives press closing at 15 MPa

    Compression molding of carbon fiber sheet molding compound under 10–15 MPa closure pressure and 140–160 °C mold temperature places the release interface under shear during charge flow, unlike autoclave or infusion processes that mainly expose the tape to through-thickness compaction. Solvay Toolcoat S/T-02 S/A is applied to the lower cavity as one ply of 0.45–0.60 mm thickness at a coverage of 1.4–1.8 kg/m²; the tape is preheated with the tool for 20 min before the first shot and re-inspected after every 50 cycles for thinning below 0.30 mm. The SMC charge is cut to 55–70% area coverage and placed at the cavity center, then compressed at a closing speed of 0.5–1.5 mm/s until the mold reaches full stops; the silicone release tape prevents charred resin buildup on the shear edges and allows demolding without external mold release sprays. Quality control includes ASTM D792-20 for silicone tape density, ASTM D2240-15e1 for durometer after thermal aging, and ISO 1183-1:2019 for cavity slab density. The process is operated under ISO 9001:2015 clause 8.5.1 and the molded parts are validated by ASTM D638-14 and ASTM D790-17 mechanical test specimens cut from the same charge. Terminal products are compression-molded CFRP closures, brackets, and battery box covers for automotive underbody applications; published S/T-02 S/A-specific compression cycle data is limited, so tool trials should be run at full press tonnage to confirm release life.

    Across high-temperature composite repair cycles on aircraft nacelle panels

    Portable hot bonder repair cycles on aircraft nacelle panels operate at 80–120 °C under 0.70 bar vacuum, where the release tape sits between the wet repair patch and a rigid caul plate to prevent adhesive flash from locking the caul plate to the part. Solvay Toolcoat S/T-02 S/A is cut 20 mm beyond the patch perimeter at a single-ply thickness of 0.30 mm, giving a local coverage of 0.9–1.1 kg/m²; the tape is perforated at 50 mm spacing to allow air evacuation and is protected by a nylon peel ply above. The repair follows FAA AC 43.214 documented wet layup or prepreg repair procedures, with the heat blanket controlled through a dual-zone thermocouple at 2–5 °C/min ramp rate and a 60–90 min dwell at cure temperature. The tape is subjected to ASTM D3330/D3330M-04 Test Method A after one repair cycle on an aluminum panel to confirm residual peel remains above 5 N/25 mm. Terminal products are repaired carbon fiber/epoxy nacelle panels and composite fan cowl repairs returned to service under the operator’s maintenance documentation. Compliance is anchored to AS9110C clause 8.5.1 for repair station process control and REACH Article 33(1) for SVHC tracking in imported repair materials.

    Free Quote

    Competitive Solvay Toolcoat S/T-02 S/A Adhesive tape prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Solvay Toolcoat S/T-02 S/A Adhesive Tape is specified as a single-coated pressure-sensitive adhesive construction in which a skived polytetrafluoroethylene (PTFE) film carries a silicone adhesive on one face. The product designation S/T-02 identifies the carrier as skived tape with a nominal thickness class; S/A denotes silicone adhesive. Exact values for total thickness, peel adhesion, dielectric breakdown, and elongation are controlled by the manufacturer’s certificate of conformance. Published data for this specific configuration is limited in aggregated secondary literature. The ranges cited in this profile therefore represent class-typical values for unsupported PTFE-film silicone-adhesive tapes unless a specific test certificate value is indicated. Typical production environments for this tape include heat-sealing jaws on form-fill-seal machines, lidding heads on tray sealers, composite mold release surfaces, and low-friction roller wraps where the interface temperature exceeds the practical limit of acrylic adhesive systems.

    Material Architecture and Nomenclature of S/T-02 S/A

    The carrier is a skived fluoropolymer film rather than a cast or extruded product. Skived PTFE is machined from a sintered billet under controlled feed and tool geometry, giving a dense film with high crystallinity and a low coefficient of friction. The S/T-02 S/A configuration combines a carrier thickness of approximately 0.002 in (0.05 mm) with a silicone adhesive transfer layer; total thickness is commonly in the range 0.10 mm to 0.20 mm depending on adhesive coat weight and slitting tolerance. Skived film produces lower contamination tendency than glass-fabric-reinforced tapes because no edge fray or glass sizing is present, but dimensional stability is lower. The silicone adhesive is selected for its temperature performance and its ability to wet clean steel and anodized aluminum surfaces at low pressure. The exposed PTFE surface energy is typically below 20 mN/m, which accounts for the nonwetting release behavior.

    Silicone pressure-sensitive adhesives in this class combine high-molecular-weight polydimethylsiloxane with silicate resin tackifiers. The resin-to-polymer ratio controls the balance between tack and high-temperature shear. A higher resin fraction increases room-temperature tack but reduces cohesive strength at elevated temperature. This distinction is operationally significant because the tape is not a structural adhesive and should not be loaded in peel or shear beyond the ranges identified in incoming inspection.

    On horizontal form-fill-seal jaws and rotary band sealers, the tape is applied as a replaceable release layer that prevents polyethylene or polypropylene sealant films from sticking to heated tooling. Substrate preparation is limited to solvent degreasing with methyl ethyl ketone or isopropanol, followed by drying at 60°C to 80°C for 10 min to remove retained solvent. Application temperatures below 10°C reduce adhesive wet-out and can increase edge lift during jaw closure. Because the PTFE carrier has a thermal conductivity of approximately 0.25 W/m·K, the tape introduces a measurable temperature drop. Machine setpoint compensation is required when the carrier thickness is changed from a glass-reinforced tape to an unsupported skived tape, especially on impulse sealers with cycle times below 1 s. Edge cuts should be made with a razor or scalpel bevel away from the seal area to avoid a raised burr that can act as a leak path across the sealing interface.

    A key process distinction on vertical form-fill-seal machines is that the tape is applied to the seal bars only; it does not alter the dwell time-pressure curve of the sealant film. Polyethylene films sealed through PTFE tape require a slightly higher bar temperature or longer dwell because the tape acts as a thermal barrier. The required compensation depends on total tape thickness and contact pressure; operators often validate by measuring seal strength according to ASTM F88/F88M-21 on the sealed pouch and comparing to the unlined-jaw baseline. A loss of seal strength greater than 0.2 N/mm after tape installation may indicate insufficient heat transfer or entrained air pockets beneath the adhesive.

    What Limits Peel Performance and Adhesion Retention Under Production Cycling?

    Peel performance of silicone pressure-sensitive adhesives on low-energy carriers is governed by adhesive crosslink density, coat weight, and substrate surface energy. For class-typical unsupported PTFE/silicone tape, 180° peel adhesion to stainless steel measured according to ASTM D3330/D3330-04 is commonly reported between 0.2 N/cm and 0.8 N/cm. These values are lower than those of acrylic transfer tapes of equivalent adhesive mass, but the primary hold-down force in heat-sealing service is compressive, not peel. Silicone adhesives retain a higher proportion of room-temperature peel strength at 150°C than acrylic systems; however, their shear resistance under sustained load is lower. A vertically mounted tape edge on a hot platen can slip if the tensile load exceeds the adhesive shear capacity. The product should not be used as a structural fastener or as a tensioned wire harness wrap without mechanical clamping.

    Adhesive transfer and edge creep are monitored after thermal exposure. On stainless steel surfaces, residual silicone can be detected by a change in water contact angle from below 20° on clean steel to above 90° on contaminated areas. Contamination of packaging film by silicone transfer is often invisible; if downstream printing or lamination is required, rollstock trials should include ink adhesion testing according to ISO 2409 or ASTM D3359. Edge creep is evaluated by measuring the distance of adhesive ooze beyond the tape edge; an ooze band greater than 0.02 mm may be unacceptable for high-clarity lidding applications because it can deposit residue on the sealing bar and, subsequently, on the package exterior.

    For autoclave or press molding of epoxy and phenolic laminates, S/T-02 S/A functions as a release surface only; it does not replace mold sealing or part draft. Tool faces are prepared with the same solvent degrease and dry cycle before tape application, and the tape is burnished with a compliant roller to exclude air pockets at the adhesive-tool interface. Silicone adhesives can bloom low-molecular-weight silicone species. A pre-cure wipe with a nonpolar solvent may reduce contamination of painted or bonded surfaces. If the tape is used as a dielectric barrier, verification of dielectric strength should be performed on compressed samples. For a 0.05 mm skived PTFE carrier, breakdown voltages above 8 kV/mm are common when measured according to ASTM D149, but local thin spots and slitting debris can reduce the withstand voltage. The tape should not be unrolled over sharp metal edges or abraded surfaces because skived PTFE has low resistance to cut propagation.

    When Silicone Adhesive Selection Is Justified Over Acrylic and Glass-Reinforced Alternatives

    Where operating temperatures exceed 120°C or where the bonding surface is a silicone-treated platen, silicone adhesive generally outperforms acrylic adhesive tape. Acrylic pressure-sensitive adhesives can lose peel strength above 120°C and may embrittle after repeated thermal cycling; silicone systems maintain release and tack over a wider temperature range. Compared with PTFE-coated woven glass tapes, skived PTFE tape produces a smoother sealing surface and leaves less imprint on thin transparent films, but its unsupported structure has lower tear strength and higher elongation under tension. In packaging of tacky confectionery or hot-melt adhesives, the skived PTFE surface reduces product buildup more effectively than polyester or polyimide release tapes because the fluoropolymer surface energy is below 20 mN/m. Polyimide tape with silicone adhesive offers higher dielectric strength per unit thickness and better puncture resistance, but it does not provide the same nonstick durability under repeated high-pressure sealing or exposure to hydrofluoric acid-containing cleaning agents.

    Unlike general-purpose PTFE tapes with high-tack acrylic adhesive, S/T-02 S/A is less likely to flow adhesive into the seal zone at temperatures above 150°C. Glass-reinforced silicone adhesive tapes resist tear propagation and maintain dimensional stability under tension, but their fabric weave can emboss a pattern into heat-sealed film, especially on high-clarity lidding structures below 0.05 mm. The choice between S/T-02 S/A and a glass-reinforced tape therefore depends on whether flatness or mechanical toughness governs the sealing station. For flat-plate sealing of printed lidding film, the unsupported skived carrier is preferred when optical clarity of the seal area is a quality gate; for wrapping curved rollers, glass-reinforced tape may reduce wrinkling.

    For high-volume lidding operations, S/T-02 S/A can be evaluated against glass-reinforced PTFE tape by measuring the seal transfer pattern on a 0.04 mm clear PET lidding film. The test should run at the maximum sealing temperature and pressure planned for production, with seal strength measured according to ASTM F88 after each set of 500 cycles. Deterioration in seal strength greater than 10% from baseline may indicate tape wear, adhesive bleed, or incomplete release of the lidding film from the sealing tool. This protocol is used on commercial tray-sealing lines and provides a direct comparison between unsupported skived PTFE and reinforced alternatives.

    On automated packaging lines, the replacement interval is determined by visual evidence of adhesive squeeze-out, edge charring, or localized release-film delamination. A failure mode observed on rotary sealers is progressive shrinkage of the PTFE carrier at temperatures above 260°C, producing a curled edge that can contaminate the sealant with fluoropolymer fragments. Operators often inspect after each shift; replacement is indicated when carrier gloss changes or when the exposed PTFE surface shows brown discoloration, which distinguishes thermal degradation from normal adhesive bleed. The silicone adhesive may leave residue on platen surfaces after extended heating above 200°C. Residue removal is performed with xylene or a formulated silicone remover, followed by an isopropanol rinse and at least 15 min solvent flash-off before reapplication. If platen temperature exceeds 260°C, an unsupported skived PTFE carrier is not recommended because thermal expansion mismatch between the tape and steel tooling causes wrinkling and adhesive degradation.

    Process window for slitting S/T-02 S/A is a controlled variable. Slitting with a dull or chipped blade can generate micro-tears along the edge, which propagate under thermal cycling on packaging machines. Edge quality is inspected under low magnification; notches deeper than 0.02 mm may be unacceptable for high-stretch wrapper or lidding applications. The tape is typically supplied in slit widths from 25 mm to 1 000 mm, but exact available widths are manufacturer-controlled. Roll diameter tolerances should be specified because silicone adhesive cold flow can cause interlayer blocking if wound too tightly under high ambient temperature.

    Incoming Inspection, Standards, and Certification Boundaries

    Incoming inspection for S/T-02 S/A should define thickness using ASTM D3652, total mass per unit area, peel adhesion using ASTM D3330, and optional dielectric breakdown using ASTM D149. Because the product is not a structural adhesive, tensile strength is commonly measured by ASTM D3759/D3759M-05 on the carrier after adhesive removal. Class-typical values for skived PTFE film fall between 20 MPa and 35 MPa tensile strength and between 150% and 350% elongation at break. The certificate of conformance for S/T-02 S/A may list different values depending on the billet, slit width, and adhesive coat weight. The table below summarizes test methods and class-typical ranges for preliminary comparison only; binding specification values are obtained from the manufacturer.

    Test methods and class-typical ranges for unsupported PTFE/silicone adhesive tape
    Property Test method Class-typical range
    Carrier thickness ASTM D3652 0.05 mm–0.13 mm
    Total tape thickness ASTM D3652 0.10 mm–0.20 mm
    180° peel adhesion to stainless steel ASTM D3330/D3330-04 0.2 N/cm–0.8 N/cm
    Dielectric breakdown voltage ASTM D149 8 kV/mm–15 kV/mm
    Tensile strength of skived PTFE carrier ASTM D3759/D3759M-05 20 MPa–35 MPa
    Elongation at break of skived PTFE carrier ASTM D3759/D3759M-05 150%–350%
    Continuous service temperature Manufacturer datum -73°C–200°C

    Compliance with food-contact regulations is not automatic. PTFE resin may meet 21 CFR 177.1550, but the silicone adhesive and any release liner or process aids require separate clearance for direct or indirect food contact. Solvay Toolcoat S/T-02 S/A should not be specified for direct food-contact release unless the full construction is listed or covered by a supplier declaration. For electrical insulation, listing under UL 510 is a candidate test route but is not assumed without a listing mark. Suppliers may be asked to provide a REACH SVHC declaration and RoHS conformity with 2011/65/EU, including exemption statements where applicable.

    Regulatory and standards applicability for candidate use
    Regulation/Standard Reference Scope of consideration
    REACH 1907/2006/EC SVHC declaration required from supplier for adhesives and film
    RoHS 2011/65/EU Lead, cadmium, mercury, chromium VI, PBB, PBDE limits
    FDA 21 CFR 177.1550 PTFE resin requirements; any food-contact use requires full tape construction clearance
    UL UL 510 Potential listing for flame barrier or insulation; not assumed without listing mark

    Rolls should be stored at 15°C to 25°C and 40% to 60% relative humidity, away from direct sunlight and ozone sources. Slitting with clean blades and compression below 0.05 MPa during storage reduces cold-flow edge ooze from the silicone adhesive. Aqueous cleaning of the tool side after tape removal is normally sufficient; aromatic solvents, ketones, or strong bases may swell the silicone adhesive without dissolving the PTFE carrier, so compatibility testing with the intended solvent blend is required before implementation on an active production line.

    Top