| HS Code | 973133 |
| Productname | Solvay LETAPE Adhesive Tape |
| Manufacturer | Solvay |
| Brand | LETAPE |
| Producttype | Structural adhesive tape |
| Adhesivechemistry | Epoxy |
| Form | Roll |
| Color | Blue |
| Curetype | Heat-curing |
| Curetemperature | 120°C or 175°C depending on grade |
| Servicetemperature | Up to 120°C or 150°C depending on grade |
| Thickness | 0.20 mm typical |
| Density | 1.2 g/cm³ typical |
| Lapshearstrength | 20 MPa typical at room temperature |
| Peelstrength | 2.5 N/mm typical |
| Shelflife | 12 months at -18°C |
| Outtime | 30 days at 23°C |
| Rollwidth | 300 mm typical |
| Rolllength | 10 m typical |
| Application | Bonding composite, metal, and honeycomb structures |
| Keyfeature | Low exotherm during cure |
As an accredited Solvay LETAPE Adhesive tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Solvay LETAPE Adhesive Tape, 50 m roll, supplied in a sealed, labeled plastic wrapper with product identification and safety information. |
| Container Loading (20′ FCL) | Optimized loading of Solvay LETAPE adhesive tape into a 20-foot FCL container, ensuring secure, compliant, and space-efficient stowage for transport. |
| Shipping | Ship Solvay LETAPE Adhesive tape in original sealed packaging, clearly labeled, as non-hazardous general cargo unless the SDS states otherwise. Maintain the recommended storage temperature; use refrigerated or dry-ice shipping if specified. Keep away from heat, sparks, flames, and direct sunlight. Ensure carrier is approved and labels remain intact. |
| Storage | Store Solvay LETAPE Adhesive tape in a cool, dry, well-ventilated area away from heat, direct sunlight, sparks, and open flames. Keep in original, closed packaging, protected from moisture, dust, and physical damage. Segregate from strong oxidizers and incompatible materials. Follow first-in/first-out rotation and shelf-life guidance. Do not store near food, drink, or animal feed. Ensure containers remain labeled and comply with local regulations. |
| Shelf Life | Solvay LETAPE adhesive tape shelf life is typically 12 months when stored unopened at 15–25°C, away from sunlight and moisture. |
In automotive exterior trim attachment, Solvay LETAPE roll stock is converted into a foam-backed double-coated tape with adhesive coatweight controlled within 90–150 g/m² on a 0.8–1.2 mm acrylic foam carrier, corresponding to a typical adhesive-to-carrier mass ratio of 0.8:1–1.1:1 after solvent removal. Compliance for this downstream segment is governed at converter level by IATF 16949:2016 and ISO 9001:2015, with substance restrictions validated against REACH Regulation (EC) No 1907/2006 Annex XVII and RoHS Directive 2011/65/EU Annex II. On production lines, the carrier is corona-treated to surface energy above 40 dyn/cm, coated with a crosslinked acrylic pressure-sensitive adhesive, dried, laminated with a silicone-coated release liner, and then rotary-die-cut at 30–80 cycles/min. Robotic vacuum end effectors apply the die-cut pads to clearcoated body panels with nip pressure of 0.2–0.4 MPa and dwell time of 10–20 s. Bond performance is checked by ASTM D3330/D3330-18 Test Method A for 180° peel adhesion to stainless steel, ASTM D1002-10(2019) for lap shear on painted steel, and ASTM D3359-17 for cross-cut adhesion after removal from OEM clearcoat. The main process boundary is plasticizer migration from unprimed TPO fascia into the adhesive layer, which can depress peel strength by up to 30% after 1,000 h at 80°C; flame or atmospheric plasma treatment is therefore imposed for low-surface-energy polyolefin substrates. Terminal finished product types include rocker panel moldings, wheel arch flares, roof ditch moldings, side body moldings, exterior emblems, and mirror housing attachments, with lot-to-lot coatweight variance held within ±5 g/m² to stabilize automated pick-and-place.
For lithium-ion battery module and display assembly, Solvay LETAPE is converted as a thin double-coated polyester or polyimide carrier with total adhesive thickness between 0.03–0.10 mm, giving an adhesive mass fraction of approximately 35–50 wt% of the finished laminate. Regulatory requirements for this sector include IEC 62368-1:2023 for information technology equipment, UL 746C for polymeric materials in electrical equipment, UL 94 V-0 for flame propagation, and IEC 61249-2-21 for halogen-free base materials, with RoHS Directive 2011/65/EU and REACH Regulation (EC) No 1907/2006 governing restricted substances. Cleanroom converters use laser cutting or matched-metal die cutting to hold dimensional tolerance at ±0.1 mm, followed by lamination onto cell pouches, display brackets, and shielding shims under 0.15–0.3 MPa pressure for 1–3 s; polypropylene battery housings are pre-treated with corona or plasma to raise surface energy above 42 dyn/cm. Humid-state performance is evaluated by ASTM D3330/D3330-18 peel retention after 1,000 h at 85°C/85% RH, with typical pass criteria requiring retained peel above 8 N/cm on stainless steel, while shear resistance is tested per ASTM D3654/D3654-18 at 70°C under a 1.0 kg static load. The dominant failure mode is interfacial moisture ingress at polycarbonate and polypropylene substrates, which can reduce peel strength by 20–40% when the adhesive lacks sufficient crosslink density; converters therefore verify gel fraction above 40% by Soxhlet extraction before release. Terminal finished products in this segment include pouch-cell compression pads, cell-to-pack retention tapes, display bracket grounding shims, speaker mesh attachment, and fingerprint sensor spacers.
Where air-barrier membranes are installed on steel-framed façades, Solvay LETAPE slit rolls function as seam closure and flashing material rather than field-applied liquid sealant. Applicators consume 1.8–2.4 m of 50 mm-wide tape per 1.0 m² of envelope area when horizontal and vertical laps are included, equivalent to a tape-to-membrane area ratio ranging from 1:10 to 1:14 depending on panel geometry. Compliance for this downstream use is framed by ASTM E2357-18 for air barrier assemblies, ASTM E2178-21 for air permeance, EN 13859-1:2014 for sheet materials used as underlays, EN 13501-1:2018 for reaction to fire classification, and ISO 11600:2011 for jointing product classification. The process sequence on a commercial façade begins with substrate cleaning and primer application where specified, followed by lap alignment at 50–75 mm and roller application at 1.5–2.0 kg/cm line pressure with surface temperatures between -5°C and 40°C; edge fillets are then formed to prevent water channeling. Adhesion is verified by ASTM D3330/D3330-18 to polyethylene and polypropylene membranes after 72 h at 23°C, with minimum peel requirement of 4 N/cm, and whole-assembly air leakage is tested under 75 Pa pressure differential per ASTM E2357-18. The critical field limitation is installation below -5°C because low initial tack to dew-point-wet membranes can permit lap separation before the adhesive fully wets the substrate; conditioned storage at 15–25°C for 24 h prior to application is required on winter sites. Terminal finished types include air barrier seams on commercial walls, window rough-opening flashing strips, roof underlayment lap joints, and vapor barrier joint closures in controlled-humidity interior zones.
In medical wearable assembly, Solvay LETAPE is converted as slit roll stock with adhesive coatweight controlled to 25–60 g/m² on breathable polyurethane nonwoven or polyolefin film face stock, yielding an adhesive-to-face-stock mass ratio of 0.3:1–0.8:1 according to target wear duration and moisture vapor transmission rate. Biocompatibility requirements are dominated by ISO 10993-5:2009 for in vitro cytotoxicity, ISO 10993-10:2021 for skin sensitization, ISO 10993-23:2021 for skin irritation, and ISO 13485:2016 for medical device quality management, with additional conformity to EU MDR 2017/745 Annex I for skin-contact materials and USP Class VI testing where polymer extracts are evaluated. The converter operates a continuous web line with closed-loop tension control at 20–50 N per 300 mm web width, deposits adhesive by transfer coating, dries through multi-zone ovens below 110°C to keep residual solvent under 50 ppm, and die-cuts electrode or sensor shapes with dimensional tolerance of ±0.2 mm. Finished devices are commonly sterilized by electron beam at 25–40 kGy or by ethylene oxide per ISO 11135:2014; a known operational boundary is that electron beam sterilization can reduce adhesive tack by 10–15%, so initial peel adhesion above 4 N/cm to stainless steel per ASTM D3330/D3330-18 is specified as compensation. Terminal product types in this segment include single-lead ECG electrode tabs, continuous glucose monitor skin pods, transdermal drug delivery backing laminates, wearable Holter monitor patches, and infusion set anchoring pads.
For buried steel pipeline field joints, Solvay LETAPE is applied over an epoxy or butyl primer after abrasive blast cleaning to NACE No. 2/SSPC-SP 10 with an angular anchor profile of 50–85 µm. The wrapping process consumes approximately 1.5–2.0 m² of tape per linear meter of pipe circumference, with overlap ratio between 50–55% and spiral tension of 10–25 N/cm to produce a void-free continuous layer. Compliance for this downstream application is defined by ISO 21809-3:2016 for field joint coatings, EN 12068:1999 for cathodic protection coatings, AWWA C214-16 for tape coating systems on steel water pipelines, and ASTM G154-16 for accelerated UV weathering of the outer wrap. The production sequence includes preheating steel to 20–50°C, primer application at 50–75 µm wet film thickness, powered spiral wrapping, and silicone-roller consolidation at 0.3–0.5 MPa line pressure to remove air cells, followed by edge burnishing to reduce soil-side disbondment. Performance is verified with ASTM D1000-17 tape property tests, ASTM G154-16 UV exposure for 2,000 h, and high-voltage holiday testing at 5 kV/mm along the wrapped joint. Published peel-adhesion data for this exact primer-tape combination is limited, so a qualification strip test per ISO 21809-3:2016 is required before full production; field failure is most common when primer is applied below 10°C or when dew-point proximity causes condensation on the steel surface. Terminal finished products in this sector include buried pipeline field joints, offshore riser clamps, flange and valve wraps, cable splice sleeves, and tank nozzle penetration wraps.
In aircraft interior panel assembly, Solvay LETAPE is interposed as a film adhesive between decorative thermoplastic or thermoset skins and Nomex or aluminum honeycomb core, with controlled film thickness of 0.05–0.15 mm and adhesive resin content of 60–75 wt% of the film mass to ensure sufficient filleting at honeycomb cell edges. Compliance is derived from FAR 25.853(a) and ABD 0031 Issue E for interior materials, with mechanical validation by ASTM D1781-98(2012) for climbing drum peel, ASTM D6415/D6415M-06a for curved beam strength, and ASTM D3039/D3039M-17 for facing tensile properties; the film is also controlled under REACH Regulation (EC) No 1907/2006 and under AS 9100D for aerospace supplier quality. The production process may be vacuum-bag-only at 0.7–0.9 bar and 120–180°C for 90–120 min, or autoclave-cured at 0.3–0.6 MPa where panel curvature requires higher consolidation. After cure, panels are edge-trimmed by CNC routers and inspected with pulse-echo ultrasonics for void content below 2%. The principal limitation is that vacuum-bag-only cycles near 120°C can leave edge porosity at panel peripheries if honeycomb moisture exceeds 2 wt%; core drying at 110°C for 4 h prior to layup is therefore imposed. Terminal finished parts in this segment include sidewall panel laminates, overhead bin scuff strips, floor panel edge closeouts, insulation blanket cover tapes, and avionics bracket damping interlayers.
Competitive Solvay LETAPE Adhesive tape prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Solvay LETAPE Adhesive tape is a fluoropolymer-backed, pressure-sensitive adhesive roll-good supplied for seaming, edge-sealing, local repair, and temporary positioning of fluoropolymer sheet linings in chemically aggressive process equipment. The product is not a single universal grade; backing resin, adhesive chemistry, liner type, roll width, and nominal thickness are assigned by the procured specification. A grade-specific certificate of analysis and technical data sheet should be the only source for lot-level values, because no single public table covers every configuration. The tape construction generally consists of a melt-processable fluoropolymer backing, a pressure-sensitive adhesive layer, and a release liner; the adhesive series controls most installation and low-load service parameters. Published data for this specific configuration is limited, so qualification on the actual substrate and under the intended chemical/temperature condition is required before production use.
The billing and engineering documents should record the full Solvay grade designator, adhesive series, liner type, roll width, and lot number. LETAPE is not a single-model product; the trade name identifies a family of fluoropolymer-backed adhesive roll-goods. A generic drawing note or procurement line that states only “Solvay LETAPE Adhesive tape” is insufficient because backing thickness, adhesive chemistry, and roll dimensions change process behaviour. Purchasers should request the current technical data sheet for the candidate grade and verify that it matches the qualified process. If a manufacturer changes adhesive formulation without a grade change, the certificate of analysis should be reviewed for lot-to-lot drift, particularly in initial peel and liner release.
Fluoropolymer film backings can retain mechanical integrity at temperatures well above the continuous-use limit of many pressure-sensitive adhesive systems, but the tape product must be treated as an adhesive laminate rather than as neat film. Peel adhesion is commonly characterised in accordance with ASTM D3330/D3330M-04(2023) or ISO 8510-2:2006, while elevated-temperature holding power is better assessed by dead-load shear procedures adapted from ISO 4587:2003 or the supplier’s internal thermal-creep method. Because adhesive creep, loss of tack, and edge lifting precede backing failure on vertical and overhead surfaces, the upper service temperature is typically dictated by the adhesive formulation and applied stress. No universal temperature rating should be inferred from the melting or continuous-use temperature of PVDF or ECTFE homopolymer. Where published data for this specific configuration is limited, the tape should be thermocoupled on a test panel at the intended immersion temperature for not less than 30 days, with pull-off or cross-cut adhesion recorded according to ASTM D3359-23 or ISO 4624:2016.
Backing thickness influences stiffness, conformability, and edge-lift stress concentration. A thinner backing may wet a blasted steel profile more readily but provides less resistance to permeation by small molecules; a thicker backing increases cut resistance and weld-line mechanical anchoring but may reduce peel on concave radii. The exact backing thickness of a given LETAPE grade must be taken from the purchase specification. Thin-film tensile properties can be measured by ASTM D882-18 or ISO 527-3:2018; adhesive coat-weight should not be used as a substitute for adhesion testing because transfer of adhesive to the liner or substrate can occur without adequate surface preparation.
The substrate must be dry, free of oil, and prepared to the specified surface cleanliness. Solvent wiping with methyl ethyl ketone or isopropyl alcohol is a final cleaning step, not a substitute for abrasive blasting when maximum peel strength is required. For carbon steel, the surface profile is normally defined by the lining specification; for stainless steel and concrete, alternative and less aggressive preparation may be acceptable. The installation window should be based on dew point and substrate temperature. Pressure-sensitive adhesives lose dwell efficiency on cold substrates and can entrap condensation when the substrate temperature is below the dew point. Users should follow the relevant cleanliness and dryness acceptance criteria in ISO 8501-1:2007 and ASTM D4417 for surface profile, with adhesion checked after application.
The tape is applied by removing the release liner in a controlled manner and laying the adhesive side onto the substrate with uniform pressure. A hand roller or driven nip should be used, with pressure sufficient to eliminate air channels but low enough to avoid stretching the backing. Any wrinkle, fold, or trapped air channel should be removed by re-rolling or by cutting and patching, not by heating the backing beyond its forming envelope. When the tape is used before hot-air welding of fluoropolymer sheet, the tape must be located outside the immediate weld track or the weld procedure must state that residue from the adhesive will not enter the melt zone. Adhesive residue inside the weld can reduce interdiffusion and create a leak path.
Overlap geometry is dictated by the lining design, not by the tape width. Tape used as a temporary positioning aid does not replace the structural weld; the final seam must be formed by a qualified hot-air or extrusion welding procedure. For welds over tape positioned on the backside, a minimum overlap of 20 mm to 50 mm is common for fluoropolymer linings, but the actual overlap and weld parameter set must be specified by the welding procedure specification. Post-application, weld continuity can be inspected by high-voltage spark testing at a voltage appropriate for the film thickness using a holiday detector operating in accordance with ASTM D5162. Published data for this specific configuration is limited; therefore, the spark-test voltage and dwell should be set on a calibration sample of the exact tape-backed seam.
In lined equipment handling aqueous hydrochloric acid, sodium hypochlorite, or metal chloride brines at temperatures above 60°C, the tape edge must be shielded from direct liquid contact by a continuous weld bead or by overlaying sheet stock, because the adhesive layer is not a rated immersion barrier. Fluoropolymer backings have low permeation but are not zero-permeation; water vapour, hydrogen chloride, and chlorine will migrate through the film at rates that increase with temperature. Permeation values for the specific backing should be measured according to ASTM D1434-23 or ASTM E96/E96M-21 as appropriate. If the adhesive is exposed, hygroscopic absorption or chemical attack can cause blister formation, loss of peel, and underfilm corrosion. Qualification should include immersion at the design temperature for a minimum of 30 days followed by adhesion and corrosion inspection. The use of the tape alone on an immersion boundary without a welded cap is not recommended unless a specific written deviation is approved by the lining engineer.
Chlorinated solvents such as trichloroethylene, chloroform, and methylene chloride can plasticise or swell many pressure-sensitive adhesive systems even when the fluoropolymer backing remains unaffected. The first visible failure is usually edge lifting, followed by a reduction in shear holding power and, in some cases, transfer of adhesive to the substrate. For this reason, LETAPE should not be specified for solvent-contact service without immersion testing in the exact solvent blend and temperature. Chemical resistance tests should follow ASTM D543-21 or ISO 2812-1:2017, with adhesion retained after exposure reported alongside visual rating.
Ketones and polar aprotic solvents deserve similar scrutiny. Although the backing film may survive superficial contact, adhesive migration at the edge can deposit residue in process streams and reduce tape integrity. In pharmaceutical or food-contact installations, extractables testing may be required under 21 CFR 175.300 or relevant regional food-contact regulations; compliance is grade-specific and cannot be assumed for every LETAPE variant. A compliance statement should be obtained from the supplier and reviewed by the end-user’s quality unit.
Automated application on pipe and duct wrapping lines requires controlled release-liner tension and a driven nip. The unwind brake should be set low enough to avoid necking the backing; liner removal angle is typically maintained near 90° to 180° to reduce delamination forces. A polished steel or polytetrafluoroethylene-coated laydown roller may be used. The roll edges must be aligned to prevent spiral gaps or overlaps that create a continuous leak path. In field repairs, the same surface-preparation rules apply as in shop fabrication; environmental controls for dew point and particulate contamination are required because field dust reduces peel adhesion faster than most chemical exposure. Permanent performance is verified by tear-down or holiday inspection after the tape is covered or welded.
Compared with commodity PVC electrical tape, LETAPE is intended for process-facing seam control rather than general-purpose electrical insulation. Electrical use is not the primary design basis, and dielectric strength must be confirmed for the specific backing if electrical isolation is required. Compared with PTFE thread seal tape, LETAPE is not a pipe-thread lubricant and should not be applied to threaded fittings. Compared with polyimide or polyester high-temperature masking tapes, the fluoropolymer backing provides chemical resistance in a wider range of mineral acids and halogens, but the adhesive system still limits service. Published data for this specific configuration is limited; substituting a different tape class based solely on upper-temperature rating is not acceptable.
The following qualification matrix identifies test methods relevant to the product class, not substitute tests for a specific grade.
| Property | Test method | Application relevance |
|---|---|---|
| Peel adhesion to metal | ASTM D3330/D3330M-04(2023), ISO 8510-2:2006 | Determines initial bond after dwell; not sufficient alone for immersion service. |
| Tensile properties of backing film | ASTM D882-18, ISO 527-3:2018 | Controls tear resistance, elongation, and weld compatibility. |
| Chemical resistance after immersion | ASTM D543-21, ISO 2812-1:2017 | Evaluates retention of peel, visual rating, and substrate corrosion after solvent or acid contact. |
| Holiday/spark testing of weld seams | ASTM D5162 | Confirms continuity of nonconductive liner after final welding. |
| Pull-off adhesion of film or coating system | ISO 4624:2016, ASTM D4541-17 | Assesses cohesive and interfacial failure after cure and exposure. |
| Surface profile of blasted steel | ASTM D4417, ISO 8501-1:2007 | Controls mechanical interlock and peel variation. |
Positioning against alternative tape classes is summarised in the following comparison.
| Product category | Typical use boundary | Difference from LETAPE |
|---|---|---|
| PVC adhesive tape | General-purpose bundling; low chemical resistance | Not suitable for fluoropolymer lining service; plasticised film and low-temperature adhesive fail earlier. |
| Polyester-silicone masking tape | High-temperature masking; no long-term chemical immersion | Silicone adhesive may survive temperature but lacks solvent resistance and is not intended for weld caps. |
| PTFE thread-seal tape | Threaded joint sealing; no flat-surface adhesion | No pressure-sensitive adhesive; not designed for lining seams or local repairs. |
| Structural acrylic foam tape | High-shear joining of metals and plastics | Higher load capacity but lower chemical resistance; may build stress at lining welds. |
| Butyl rubber tape | Temporary corrosion wrap and cable jointing | Lower upper service temperature and higher extractables; not compatible with strong oxidising environments. |
| Solvay LETAPE | Fluoropolymer lining seam control, edge sealing, repair | Adhesive selected for process compatibility; must be welded or capped for continuous immersion. |
Initial peel strength is time-dependent. Immediately after laydown, adhesion may be substantially lower than after 24 h of dwell at controlled temperature. This is normal for pressure-sensitive systems: the adhesive must flow into the blast profile and wet the substrate. Accelerated dwell should not be used unless the supplier’s technical bulletin defines the dwell temperature and ramp rate. A heated silicone blanket or quartz lamp may be used on large vessels, but local surface temperature must be monitored with a contact thermocouple. If the tape is over-heated, the adhesive can foam or leave residue at the edge; if the substrate is below the dew point, condensation can become trapped. Production records should include surface profile, dew point, substrate temperature, roll lot, dwell temperature, and dwell time. These records are part of the inspection and test plan rather than a separate quality note.
Edge lifting under cyclic thermal service is often caused by mismatch in coefficient of linear thermal expansion between the tape backing and the steel substrate. The resulting shear stress concentrates at the tape edge; repeated cycling can initiate peel even when initial adhesion is acceptable. A chamfered or thin-edged design is preferable to a square cut on thick backing because it reduces the mechanical leverage at the termination. This edge geometry should be specified in the lining detail drawing. If edge lifting is found during inspection, the affected tape must be removed and the surface reprofiled; applying a patch over a lifted edge traps the chemical load against the substrate and accelerates corrosion.
Roll storage should follow the supplier’s stated temperature and humidity limits; pressure-sensitive adhesives can lose tack when stored above the maximum stated temperature or exposed to ultraviolet light for extended periods. Liner release can increase if the roll is subjected to moisture or excessive winding tension. On production-scale equipment, edge lifting is observed most often when the tape is applied to a cold steel substrate and then exposed to a hot process fluid before the adhesive has fully wetted the surface profile. This failure is not necessarily a material deficiency; it is an installation and commissioning sequencing issue. A post-application warm dwell period may improve wet-out, but the exact dwell temperature and time are adhesive-grade-specific. The process should be validated with a holiday test and pull-off adhesion before the vessel is returned to service.