| HS Code | 467935 |
| Melt Flow Rate 190 C 2 16 Kg | 6.0 g/10 min |
| Density | 0.944 g/cm³ |
| Tensile Yield Strength | ≥23 MPa |
| Elongation At Break | ≥500 % |
| Flexural Modulus | ≥900 MPa |
| Izod Notched Impact Strength | ≥10 kJ/m² |
| Vicat Softening Temperature | ≥120 °C |
| Brittleness Temperature | ≤-70 °C |
| Shore D Hardness | 65 |
| Molding Shrinkage | 1.5-2.5 % |
| Water Absorption | ≤0.01 % |
| Volume Resistivity | ≥1×10^16 Ω·cm |
| Dielectric Constant | 2.3 |
| Dielectric Loss Tangent | ≤5×10^-4 |
| Melting Point | 130-135 °C |
| Thermal Conductivity | 0.45 W/(m·K) |
| Coefficient Of Linear Thermal Expansion | 1.2×10^-4 /°C |
| Specific Heat Capacity | 1.9 kJ/(kg·K) |
As an accredited Sinopec Qilu HDPE J4406-6(QHJ02) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Sinopec Qilu HDPE J4406-6(QHJ02) comes in 25 kg woven bags, 40 bags per pallet, totaling 1,000 kg. |
| Container Loading (20′ FCL) | Sinopec Qilu HDPE J4406-6(QHJ02) is securely loaded into a 20′ FCL container, palletized, shrink-wrapped, and stowed for export shipment. |
| Shipping | Sinopec Qilu HDPE J4406-6 (QHJ02) is shipped as non-hazardous high-density polyethylene resin pellets in 25 kg bags, palletized and stretch-wrapped, or in bulk containers. Transport by truck, rail, or sea freight. Store dry; protect from moisture, UV, heat, and contamination. Standard shipping documents; no dangerous goods classification. Keep sealed until use. |
| Storage | Store Sinopec Qilu HDPE J4406-6(QHJ02) in a cool, dry, well-ventilated warehouse, preferably below 40°C, in sealed original bags on pallets. Protect from direct sunlight, rain, moisture, and contamination. Keep away from heat, ignition sources, and strong oxidizers. Use FIFO stock rotation; avoid prolonged outdoor exposure and excessive stacking. Do not store near incompatible materials. |
| Shelf Life | Shelf life is typically 24 months from production when stored cool, dry, ventilated, in original sealed packaging, away from sunlight. |
Qilu J4406-6 (QHJ02) is a high-molecular-weight, natural-color high-density polyethylene pipe resin with a typical melt flow rate of 0.6 g/10 min under ISO 1133-1 condition T and density of 0.944 g/cm³ under ISO 1183-1. Tensile yield strength is 22 MPa and elongation at break exceeds 600% under ASTM D638-14. These values place the grade within the solid-wall pressure-pipe extrusion window where molecular weight retention, melt temperature control, and long-term hydrostatic strength are the controlling variables. The downstream applications described below are limited to industrial sectors that specify HDPE solid-wall pressure pipe: potable water distribution, natural gas distribution, large-diameter water transmission, ground-source heat exchange, agricultural drip irrigation, and abrasive slurry or ash handling. Independent technical literature for certain niche configurations using this specific Qilu grade is sparse. Where such data are absent, the stated processing ranges are drawn from PE100 pipe-resin extrusion practice and shall be verified against the supplied mill certificate before production release.
Qilu J4406-6 (QHJ02) is typically processed into solid-wall pressure pipes for municipal drinking water on single-screw extruders with grooved feed bushings and barrier screws, with L/D ratio between 30:1 and 36:1. The barrel profile is set from 180°C to 220°C from feed to metering. Melt temperature measured at the adapter is held at 210°C to 230°C, while die head zones are controlled at 200°C to 215°C to limit die-lip drool and oxidative degradation. A screen pack of 60/80/100 mesh behind the breaker plate generates head pressure above 18 MPa and removes incidental gel particles. Melt pump differential pressure is limited to 15 MPa because higher differential pressure creates shear heating above 240°C and measurable melt flow rate increase. For potable water service, the extrudate is compounded with 2.0 wt% to 2.5 wt% carbon black masterbatch containing 40% carbon black, yielding 2.0% to 2.5% carbon black by mass as required by ISO 4427-1 and EN 12201-1. Primary carbon black particle size below 25 nm is maintained to meet UV stabilization requirements. Vacuum calibration is set at -0.03 MPa to -0.06 MPa; first cooling tank water is staged at 25°C to 40°C to control residual stress. Hydrostatic testing under ISO 1167-1 uses 12.4 MPa hoop stress at 20°C/100 h and 5.4 MPa at 80°C/165 h. No ductile or brittle failure is accepted. Drinking water contact extraction follows NSF/ANSI/CAN 61 and AS/NZS 4020:2018. Pre-drying at 80°C for 4 h is applied if silo moisture exceeds 0.01%; residual moisture at relative humidity above 60% causes micro-voids at spider-leg weld lines. The terminal product is a black or blue PE100 pressure pipe with outside diameter from 20 mm to 1,600 mm, rated for continuous cold-water service at 1.25 MPa to 2.0 MPa.
Natural gas distribution pipe produced from Qilu J4406-6 (QHJ02) uses a single-screw extruder with 33:1 L/D, melt pump, spiral mandrel die, and vacuum sizing. Barrel set points run from 185°C to 225°C, while adapter melt temperature is capped at 230°C to preserve molecular weight and rapid crack propagation resistance. The formulation commonly contains 2.0 wt% to 2.5 wt% carbon black masterbatch and 1.0 wt% to 2.0 wt% yellow pigment masterbatch for identification. When coextruded yellow stripe construction is used, stripe-layer melt temperature is kept within ±5°C of the core layer to avoid interfacial weakness. Pipe compliance follows ISO 4437-1, EN 1555-1, GB 15558.1-2015, and ASTM D2513-20. Short-term hydrostatic requalification includes 20°C/100 h at 12.4 MPa hoop stress and 80°C/165 h at 5.4 MPa hoop stress. Rapid crack propagation is measured by the ISO 13477 S4 test; PE100 gas pipe typically has critical pressure above 16 bar at 0°C, but published data for this specific Qilu configuration are limited. Butt fusion parameters under ISO 21307 use heater plate temperature 210°C to 230°C, soaking interfacial pressure 0.15 MPa, and cooling pressure 0.15 MPa until uniform bead formation. The terminal product is SDR 11 or SDR 17.6 yellow or black-with-yellow-stripe gas distribution pipe rated up to 0.7 MPa maximum operating pressure, installed at depths of 0.6 m to 1.2 m.
Sag and wall-thickness eccentricity limit large-diameter pipe extrusion from Qilu J4406-6, especially outside diameter above 500 mm. Melt temperature at the die exit is held between 195°C and 215°C to maintain parison shape. Die gap is set at 1.5 to 2.0 times final wall thickness. Multi-point ultrasonic wall-thickness gauging after the first vacuum tank validates minimum wall thickness no less than 0.90 times nominal wall, per ISO 4427-2. For outside diameter up to 630 mm, first cooling tank water is maintained at 25°C to 35°C. Larger diameters above 630 mm use two-stage cooling at 40°C to 50°C to reduce frozen-in stress. The formulation incorporates 2.0% to 2.5% carbon black and a hindered phenol/phosphite antioxidant system at 0.10 wt% to 0.15 wt% combined, which is regarded as a typical stabilization package for pipe-grade HDPE. Terminal product in this segment is solid-wall PE100 pipe with outside diameter up to 1,600 mm and dimension ratios SDR 13.6 to SDR 26, installed for municipal water transmission under AWWA C906-15 and ISO 4427-2. Hydrostatic design basis of 10 MPa and design safety factor 1.25 per ISO 12162 govern pressure rating.
Ground-source heat pump loops are assembled from Qilu J4406-6 pipe that must withstand intermittent thermal cycles from 0°C to 40°C while buried in saturated soil. The resin is extruded into SDR 11 and SDR 9 pipe, typically 25 mm to 63 mm outside diameter, with wall thickness selected for 1.6 MPa pressure rating under ASHRAE/IGSHPA installation guidelines. Haul-off speed is matched to melt output within 0.5% to minimize axial orientation; residual stress from excessive drawdown accelerates environmental stress cracking under cyclic service. Pipe is tested for environmental stress crack resistance under ASTM D1693-15 Condition B at 50°C. PE100 pipe-grade HDPE commonly exceeds 1,000 h in 10% Igepal CO-630, though published values for this exact Qilu grade remain limited. Heat exchange performance is constrained by HDPE thermal conductivity of 0.4 W/(m·K) per ISO 22007-2, so grout thermal conductivity and loop spacing dominate system design. Butt and socket fusion follow ASTM F2620-23 with heater plate temperature 210°C to 230°C. Pressure integrity is verified on site by hydrostatic test at 2.5 MPa for 30 min. The terminal product is a U-bend assembly or straight loop pipe with outside diameter up to 63 mm, sized to maintain Reynolds number above 4,000 under design flow and to avoid laminar fouling.
In agricultural drip irrigation networks, Qilu J4406-6 (QHJ02) is converted into mainline and submain pipe that operate at 0.4 MPa to 1.0 MPa and are exposed to chlorinated water, fertilizer salts, and UV radiation. The resin is formulated with 2.0 wt% to 2.5 wt% carbon black masterbatch and 0.05 wt% to 0.15 wt% calcium stearate as acid scavenger to neutralize residual chlorine species. Free chlorine at concentrations above 2 ppm combined with pH below 5 shortens oxidative induction time and is considered an operational boundary. Extrusion uses a single-screw extruder with 30:1 L/D, grooved feed section, and basket-type die for outside diameter from 12 mm to 110 mm. Melt temperature is set at 200°C to 220°C to achieve internal surface roughness Ra below 10 µm, preserving the Hazen-Williams C factor of 150 used in drip system hydraulic design. Dimensional stability and pressure performance are assessed under ISO 8779 and ISO 9261. Coextruded blue stripe layers identify water service. Terminal product is black PE100 pipe with SDR 11 to SDR 17 and outside diameter up to 110 mm, joined by barbed or compression fittings and laid in laterals where pressure rating is derated for elevated temperature using ISO 13761.
Abrasive slurry transport in mining, dredging, and coal-fired power ash handling uses Qilu J4406-6 pipe for its 600% elongation at break and resistance to slow crack growth, not for metallic-equivalent abrasion resistance. Thick-wall pipe is extruded with SDR 11 to SDR 21 and wall thickness up to 60 mm. Slow cooling is mandatory because residual stress in thick sections can reduce environmental stress crack resistance under cyclic slurry pressure. Die temperature is held at 195°C to 210°C, vacuum calibration at -0.05 MPa, and cooling water from 40°C to 60°C to avoid voids and sink marks. Formulation ratios include 2.0% to 2.5% carbon black for UV stabilization. Regrind addition above 10 wt% is avoided because hydrostatic design stress decreases with repeated heat history. Pipe compliance for abrasive service is verified by hydrostatic pressure testing under ISO 1167-1 at 12.4 MPa hoop stress for 100 h and by joint testing after butt fusion per ASTM F2620-23. Abrasion resistance is not a pressure-rating property but can be compared through mass loss under DIN 53516. The terminal product is ash-handling or tailings pipe with outside diameter from 90 mm to 1,200 mm, rated up to 1.25 MPa maximum operating pressure and joined exclusively by electrofusion or butt fusion to maintain a leak-tight line.
| Application | Terminal product | Governing standards | Critical test condition |
|---|---|---|---|
| Potable water | PE100 solid-wall pipe, 20–1,600 mm | ISO 4427-1, EN 12201-1, NSF/ANSI/CAN 61, AS/NZS 4020:2018 | ISO 1167-1: 20°C/100 h at 12.4 MPa; 80°C/165 h at 5.4 MPa |
| Natural gas distribution | SDR 11/17.6 gas pipe, 0.7 MPa MOP | ISO 4437-1, EN 1555-1, GB 15558.1-2015, ASTM D2513-20 | ISO 13477 S4 critical pressure >16 bar at 0°C |
| Large-diameter water transmission | PE100 pipe up to 1,600 mm, SDR 13.6–26 | AWWA C906-15, ISO 4427-2, ISO 12162 | Wall thickness ≥0.90 nominal; HDB 10 MPa |
| Ground-source heat exchange | SDR 9/11 U-bend loop, 25–63 mm | ASHRAE/IGSHPA, ASTM F2620-23, ISO 22007-2 | ASTM D1693-15 Condition B at 50°C, >1,000 h |
| Agricultural drip irrigation | Black PE100 mainline/submain, 12–110 mm | ISO 8779, ISO 9261, ISO 13761 | Ra <10 µm; Hazen-Williams C factor 150 |
| Abrasive slurry/ash handling | Thick-wall PE100 pipe, 90–1,200 mm | ISO 1167-1, ASTM F2620-23, DIN 53516 | 12.4 MPa hoop stress for 100 h; fusion joint tensile test |
Competitive Sinopec Qilu HDPE J4406-6(QHJ02) prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Sinopec Qilu HDPE J4406-6(QHJ02) is a high-density polyethylene injection-molding grade manufactured by Sinopec Qilu Petrochemical Co., Ltd. at Zibo, Shandong. The designation carries a nominal melt mass-flow rate of 6.0 g/10 min when measured at 190 °C under 2.16 kg piston load (ISO 1133-1:2022 / GB/T 3682.1-2018) and a nominal density of 0.944 g/cm³ (ISO 1183-1:2019 / GB/T 1033-1986). Supplier technical literature for the QHJ02 sub-designation identifies the material as a medium-flow injection grade for crates, caps, closures, housewares, and thin-wall packaging. Because published datasheets for this specific QHJ02 configuration are limited, the following profile combines supplier-reported grade data with the general processing envelope for high-density polyethylene injection grades of this melt-flow class. Applications requiring regulatory certification should be confirmed with the seller’s certificate of analysis and compliance statement.
Compared with high-load melt-index blow-molding high-density polyethylene grades, which typically fall in the 0.2–1.2 g/10 min melt-flow range at 2.16 kg, the 6.0 g/10 min flow rate shifts the material toward lower melt pressure in multi-cavity tools and shorter fill times. The penalty is reduced melt strength and lower environmental stress crack resistance than higher-molecular-weight high-density polyethylene grades. Similarly, the 0.944 g/cm³ density is below the 0.953–0.957 g/cm³ range used for high-stiffness container and pipe resins, which indicates a deliberate balance between flow and part rigidity.
| Property | Standard | Unit | Nominal reported value |
|---|---|---|---|
| Melt mass-flow rate (190 °C, 2.16 kg) | ISO 1133-1:2022 / GB/T 3682.1-2018 | g/10 min | 6.0 |
| Density | ISO 1183-1:2019 / GB/T 1033-1986 | g/cm³ | 0.944 |
| Tensile stress at yield | ISO 527-2:2012 / GB/T 1040.1-2018 | MPa | 22 (lot-dependent) |
| Notched Charpy impact at 23 °C | ISO 179-1/1eA:2023 / GB/T 1043.1-2008 | kJ/m² | 4–6 (lot-dependent) |
The values in Table 1 are representative and not batch-release specifications. Converters must obtain a certificate of analysis for each lot and validate the grade on production-scale equipment before transfer to commercial volumes.
Within the Qilu high-density polyethylene portfolio, J4406-6(QHJ02) occupies the medium-flow injection segment between high-flow injection grades with melt-flow values above 20 g/10 min and low-flow blow-molding or film grades. The molecular weight distribution is sufficiently broad to maintain notched impact strength under GB/T 1043.1-2008 and to permit melt processing without fluoropolymer process aids that are sometimes required for high-molecular-weight polyethylene. In automotive or appliance applications where a part must withstand repeated low-temperature impact, the grade’s medium molecular weight requires careful gate placement and avoidance of weld lines in highly loaded regions.
Additive compatibility is an operational boundary. The grade is supplied with antioxidant stabilization; it should not be dry-blended with amine-based heat stabilizers unless validated because amine chemistries can interact with the catalyst neutralizer package and shift color or process stability. No specific published incompatibility data for QHJ02 is available; converter testing under ISO 18314-1:2015 color measurement is recommended for any additive change. The grade is also not intended for blown film, pipe extrusion, or large-part blow molding, where melt strength and long-term hydrostatic performance dominate.
| Resin family | Nominal melt-flow indicator | Nominal density | Primary processing route | Relative limitation |
|---|---|---|---|---|
| Sinopec Qilu HDPE J4406-6(QHJ02) | 6.0 g/10 min (2.16 kg) | 0.944 g/cm³ | Injection molding | Lower ESCR than blow-molding HDPE |
| HDPE blow-molding grades | 0.2–1.2 g/10 min | 0.953–0.957 g/cm³ | Extrusion blow molding | Higher screw torque and slower fill |
| HDPE pipe grades | <0.1 g/10 min (5 kg) | 0.945–0.952 g/cm³ | Pipe extrusion | Not suitable for high-flow injection |
| HDPE film grades | 8–15 g/10 min HLMFR (21.6 kg) | 0.945–0.952 g/cm³ | Blown film | Poor thick-section dimensional stability |
Melt temperature is usually set between 190 °C and 240 °C. Below 190 °C, injection pressure rises sharply in thin-wall sections below 1.0 mm, and short-shot incidence increases. Above 240 °C, long residence times above 10 min can produce yellowing and a drop in impact properties due to thermo-oxidative degradation. Barrel profile settings from rear to nozzle are commonly 180 °C, 200 °C, 220 °C, 230 °C, nozzle 230–240 °C. Screw speed for a 45 mm diameter screw should be limited to 80–120 rpm; for larger 80 mm screws, lower peripheral speeds of 0.3–0.5 m/s are preferred. Back pressure of 0.5–1.0 MPa hydraulic helps melt homogenization, but excessive back pressure raises residence time and shear heating.
On production lines with 2000 kN clamp force and 32-cavity hot-runner cap molds, process adjustments should be based on pressure-drop measurements from injection molding machine load cells, not visual fill alone. A short-shot study at 5% weight increments from 60% to 95% of full fill allows establishment of the lower fill boundary; holding pressure is then increased until gate freeze is confirmed by part weight stabilization to within ±0.15%. For valve-gate systems, delayed gate opening of 0.5–1.0 s after fill onset can reduce gate-stringing, although no published data specific to this QHJ02 designation is available.
For returnable crates and logistics containers, the material is processed with wall thicknesses from 2.0–4.0 mm. The flow length should be kept within 120:1 to 150:1 unless verified by spiral flow testing. Ejector pins should be located on ribs and bosses to avoid local deformation because high-density polyethylene has lower modulus than filled or reinforced thermoplastics. Gate sizes for edge-gated crates are often 50–80% of wall thickness, and land length is kept below 1.5 mm to reduce pressure loss.
Mold shrinkage for high-density polyethylene in this density and melt-flow class is typically 1.5–2.5% in flow direction and 1.0–2.0% transverse, depending on wall thickness, gate type, mold temperature, and holding pressure. Thicker sections above 3.0 mm show higher shrinkage and greater sink-mark risk because crystallization continues after gate freeze. Measurements made under ISO 294-4:2018 or ASTM D955-08(2018) should be generated on the actual cavity geometry; using generic laboratory plaque shrinkage can lead to dimensional error greater than 0.5% in cavities with flow length above 150 mm.
Mold temperature is typically maintained at 20–50 °C. At the lower end, cycle time is reduced but surface gloss and impact strength may decline. At the upper end, shrinkage increases, cooling time lengthens, and flatness deviations become more common. The grade’s medium flow rate reduces injection pressure requirements, but worn mold interlocks with clearances above 0.05 mm may flash under packing pressures above 60 MPa hydraulic. Dimensional control therefore requires a stable mold temperature control unit with a supply manifold variation not exceeding ±2 °C.
Closure applications use this type of high-density polyethylene for short-cycle production of tamper-evident caps, dispensing closures, and jar lids. The material’s specific stiffness is lower than polypropylene, but its low-temperature impact and resistance to stress whitening are advantageous. When replacing polypropylene in a closure, designers account for a flexural modulus of approximately 700–900 MPa for high-density polyethylene versus 1100–1300 MPa for polypropylene copolymer under ISO 178:2019, requiring rib or wall-thickness adjustments. In food-contact packaging, converter compliance is required under GB 4806.6-2016, EU Regulation (EU) No 10/2011, or 21 CFR 177.1520, and the supplier’s compliance statement should be reviewed for specific migration limits.
Regrind integration has greater influence on melt viscosity consistency than on short-term tensile properties. Clean sprues, runners, and rejected parts can be reintroduced at up to 20 wt% without measurable shift in melt-flow rate when regrind is ground to a uniform particle size of 4–8 mm through a granulator with screen opening of 6 mm. Above 20 wt%, particle-size variability and repeated heat history can increase melt-pressure fluctuation and part-weight variation. The use of closed-loop shot-size control is recommended when regrind ratios exceed 20 wt%; otherwise shot-to-shot variation may exceed ±0.3% on machines without automatic viscosity compensation.
Storage conditions influence surface moisture rather than bulk water absorption. High-density polyethylene is not hygroscopic, but condensation on cold pellets moved into a humid processing hall with relative humidity above 60% can cause splay. Pellets should be kept in sealed hoppers or pre-dried at 80 °C for 2 h with a desiccant dryer if surface moisture is suspected. Prolonged hopper holding above 4 h at processing temperature is not recommended because long residence time can increase oxidation, particularly in hot-runner systems with dead spots.
Incoming quality control for this product should include melt mass-flow rate by ISO 1133-1:2022, density by ISO 1183-1:2019, and visual contamination assessment. Some converters add notched impact testing under ISO 179-1/1eA:2023 at 23 °C and -20 °C for seasonal transportation applications. Lot-to-lot variation in melt-flow rate within ±0.5 g/10 min can alter fill behavior in multi-cavity tools; therefore, process parameter changes should not be made before verifying the material certificate of analysis against the previous lot.
In applications where a higher-density, lower-flow high-density polyethylene is currently used, replacing with J4406-6(QHJ02) can shorten fill time and reduce clamp force requirement, but the change also lowers environmental stress crack resistance and long-term creep modulus. A substitution evaluation should include top-load testing under ISO 12048:2000 for containers, environmental stress crack resistance testing under ASTM D1693 for chemical exposure, and stack-life simulation at 40 °C and 90% RH for transport packaging. Published data for this specific QHJ02 configuration is limited; final conversion should be based on production-scale validation on the intended tool.