| HS Code | 709420 |
| Manufacturer | Saint-Gobain |
| Product Name | Saint-Gobain CHR SG06-14(R) Premium Glass-PTFE Backing Silicone Adhesive Pressure Sensitive Tape |
| Product Code | SG06-14(R) |
| Tape Type | Pressure-sensitive tape |
| Backing Material | Glass-PTFE (PTFE-coated glass cloth) |
| Adhesive Type | Silicone |
| Total Thickness | 14 mil (0.36 mm) |
| Backing Thickness | 6 mil (0.15 mm) |
| Adhesive Thickness | 8 mil (0.20 mm) |
| Color | Brown |
| Temperature Range | -100°F to 500°F (-73°C to 260°C) |
| Tensile Strength | 200 lb/in (35 N/mm) |
| Elongation | 5% |
| Adhesion To Steel | 25 oz/in (2.7 N/cm) |
| Dielectric Strength | 500 V/mil |
| Standard Length | 36 yd (33 m) |
| Standard Core Diameter | 3 in (76 mm) |
| Release Liner | Yes (R suffix indicates release liner) |
| Shelf Life | 12 months from date of manufacture |
As an accredited Saint-Gobain CHR SG06-14(R) Premium Glass-PTFE Backing Silicone Adhesive Pressure Sensitive Tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Packaging: one roll per sealed plastic bag inside a labeled cardboard carton; quantity: 1 roll per package. |
| Container Loading (20′ FCL) | 20′ FCL container loading: palletized rolls of Saint-Gobain CHR SG06-14(R) tape, shrink-wrapped, strapped, and secured for safe ocean transport. |
| Shipping | Shipping: Saint-Gobain CHR SG06-14(R) tape is non-hazardous and not regulated for transport. Ship rolls in original packaging, clean, dry, and protected from heat, sunlight, moisture, and contamination. Maintain ambient temperature. No DOT/IATA/IMDG special provisions. Use sturdy cartons. Handle carefully to prevent backing damage or adhesive transfer. |
| Storage | Store in a cool, dry, well-ventilated area away from direct sunlight, heat, sparks, flames, moisture, and incompatible chemicals. Keep in original sealed packaging, clearly labeled, upright, and clean. Maintain moderate temperature and humidity; avoid extreme conditions. Protect from dust, physical damage, and contamination. Do not store near oxidizers or acids. Observe shelf life and rotate stock using first-in, first-out. |
| Shelf Life | Shelf Life: Typically 24 months from date of manufacture when stored unopened at 70°F (21°C) and 50% relative humidity. |
Saint-Gobain CHR SG06-14(R) is a woven glass-fibre laminate coated with sintered polytetrafluoroethylene on the release face and laminated to a cured silicone pressure-sensitive adhesive on the adhesive face. Characterisation references include ASTM D3330/D3330M-04(2018) for peel adhesion, ASTM D3652-16(2021) for total thickness, ASTM D1000-17 for electrical insulation tape properties, and IEC 60454-2 where flexible insulating tape requirements apply. The backing construction creates a low-surface-energy release face, and the silicone adhesive is selected for high-temperature adhesion to metals, selected thermoplastics, and high-durometer silicone surfaces. Replacement intervals on production equipment are determined by peel adhesion decay, backing surface crazing, and edge lift rather than by visual colour change alone. The downstream scenarios below are confined to sectors in which PTFE-glass/silicone adhesive tapes are used on existing production equipment. Each scenario states the relevant compliance baseline, the installed tape ratio, the production process, and the terminal article.
Form-fill-seal packaging lines that weld polyolefin or coextruded films at the longitudinal and transverse seal jaws depend on rapid molten-film release to avoid film drag, seal curl, and sealant transfer. SG06-14(R) is installed on degreased chromed aluminium or stainless-steel jaw faces as a single-layer release cover. The installed tape ratio is 1.0 m of tape per 1.0 linear m of sealing jaw; the splice is cut with a 50% overlap relative to the tape width, and no additional layer is added in the transverse sealing zone. The jaw setpoint is held between 110 °C and 190 °C, with seal dwell of 0.3–1.5 s and jaw pressure of 0.2–0.6 MPa, depending on the film sealant layer. The sintered PTFE face provides the release surface against metallocene linear low-density polyethylene, ethylene vinyl acetate, and cast polypropylene sealants, while the silicone adhesive remains below its oxidative degradation threshold. Compliance in food-contact packaging is governed by FDA 21 CFR 177.1550 for the PTFE component and FDA 21 CFR 175.300 for the silicone adhesive only when the end-use food type and temperature satisfy the regulation; the glass-fibre reinforcement is not treated as a direct food-contact layer. EU applications are additionally subject to EC 1935/2004 and EU 10/2011 migration requirements, so the tape must be covered by a food-contact declaration. Terminal products include snack pillow packs, frozen vegetable pouches, medical device pouches using peelable Tyvek, and retort pouch formats where the sealing dwell is extended to 2–5 s and verified by multipoint thermocouple measurement.
In autoclave debulking of carbon-epoxy prepreg layups, free epoxy bleed at the vacuum bag seal line can bond the bagging film to the tool flange, causing de-moulding damage and tool cleaning delays. SG06-14(R) is applied to degreased tool flanges and caul plate edge brackets with the silicone adhesive side against the metal and the sintered PTFE side facing the vacuum bag sealant. The installed coverage ratio is one full flange strip; splices are lapped 12.7 mm, which corresponds to an overlap ratio of approximately 50% for 25 mm tape, and no gap is permitted at the flange boundary. The tape is processed at autoclave profiles up to 180 °C and 0.6 MPa for commonly used 180-cure epoxy prepreg systems, and the layered construction prevents mastic sealant transfer during the debulk and cure sequence. Compliance is demonstrated through REACH EC 1907/2006 SVHC declarations, RoHS 2011/65/EU where the composite tooling is part of an electrical or electronic component, and ASTM D3330/D3330M-04(2018) peel adhesion measured before and after each heat cycle. The silicone adhesive cannot be applied to tools carrying fluorinated release paste or unremoved wax because adhesion loss occurs at the interface; tools must be solvent-cleaned and oven-dried before installation. Terminal products include carbon-fibre wing spar caps, nacelle cowl panels, light aircraft airframe stiffeners, and automotive Class-A body panels.
Random-wound stators and armatures require slot liners, phase insulation, and wedge fixation to remain dimensionally stable during vacuum-pressure impregnation with epoxy or polyesterimide varnish. SG06-14(R) is used to secure the slot liner at the core tooth joint before preheating at 120–150 °C and subsequent vacuum-pressure impregnation. The tape is applied as a single spiral wrap with 50% overlap, producing an effective 2:1 layer ratio in the overlap zone and no air gap under the lamination stack. The silicone adhesive faces the insulation paper or varnished substrate, and the PTFE face prevents the uncured resin from bonding to the tape surface, permitting visual inspection of the varnish colour and thickness per IPC/WHMA-A-620 workmanship criteria. Compliance is referenced to UL 510 for pressure-sensitive adhesive tape used as electrical insulation, ASTM D1000-17 for dielectric strength and insulation resistance, IEC 60454-2 for flexible insulating tapes, and REACH EC 1907/2006 for the European market. The total thickness of 0.006 in contributes 0.15 mm of wall build; a single layer is permitted below the slot wedge, and a double layer is limited to the end-turn area so that slot-fill factor remains within the designed limit. Terminal products are fractional-horsepower motors, inverter-driven servo motors, generator sets, and dry-type transformers where insulation class H thermal endurance is specified.
Continuous fusing presses used to bond woven and nonwoven interlinings to garment shell fabrics expose the transport belt and pressure rollers to molten polyamide or polyester web adhesive at 120–180 °C, with belt speed of 3–8 m/min and nip pressure of 0.2–0.4 MPa. SG06-14(R) is installed on the belt splice region and on edge tracking zones as a replaceable release layer. The tape application ratio is one full-width strip across the belt width with a 50 mm overlap at the splice and no lateral gap exceeding 1 mm, because lateral gaps allow adhesive aerosol to deposit on the rubber belt and transfer to the shell fabric. The silicone adhesive adheres to the fiberglass/PTFE belt substrate, and the sintered PTFE face prevents molten adhesive from creating a peel point at the fusing nip. Compliance is assessed under REACH EC 1907/2006 and RoHS 2011/65/EU for fusing presses supplied as electrical appliances; no direct skin-contact or apparel-contact safety claim is made. Replacement intervals are based on roller peel force per ASTM D3330/D3330M-04(2018) and on surface crazing observed during shift inspections. Terminal products include tailored jacket fronts, trouser waistbands, shirt collars and cuffs, automotive seat covers, and thermally bonded textile panels.
Web converting lines that laminate pressure-sensitive adhesive films, optical display layers, and photovoltaic backsheet materials rely on precision-gap nip rollers to apply a uniform consolidation force to the moving web. Rubber nip rollers accumulate transferred adhesive, alter the gap, and create coating defects; the roller is therefore covered with SG06-14(R) with the silicone adhesive side on the cleaned rubber surface and the PTFE side facing the moving web. The roll-covering ratio is 100% of the contact width; a butt splice or 2 mm expansion gap is used according to the roller supplier’s thermal expansion calculation, and overlap is not permitted because an overlap ridge embosses the coating and produces a hard band in the finished roll. The low-friction face is evaluated for coefficient of friction per ASTM D1894, and peel adhesion is measured per ASTM D3330/D3330M-04(2018) before installation. Compliance for electronic material converters is supported by IEC 62421 for halogen-free operation, REACH EC 1907/2006, and RoHS 2011/65/EU; where the roller contacts food packaging substrates, the user must verify food-contact status under FDA 21 CFR 177.1550 for PTFE and FDA 21 CFR 175.300 for silicone adhesive. At line speeds above 150 m/min, inadequate roller taper can cause lateral tape creep; published data for SG06-14(R) under precision-gap nip service is limited, so roller suppliers should validate the adhesive against the intended speed and gap force. Terminal products include pressure-sensitive label stock, flexible printed circuit coverlays, optical display film, and photovoltaic backsheet laminates.
On heated rotary transfer presses used for dye sublimation of polyester textile webs, the glass-PTFE tape serves as a replaceable release liner between the transfer paper and the heated cylinder, preventing dye redeposition and paper-fibre accumulation. The cylinder surface is maintained at 200–220 °C; SG06-14(R) is spirally wrapped at 50% overlap, creating a fully closed surface with a double-thickness overlap region. The spiral wrapping ratio is specified as 1.0 m of tape per 1.0 m of cylinder circumference plus the overlap allowance, and a 25 mm end overlap caps the exposed adhesive edge. The adhesive side is applied to a clean, dry cylinder free of residual dye oils; the crosslinked silicone network resists softening at press temperature, and the sintered PTFE face allows the printed paper to release without tearing. Compliance is evaluated under REACH EC 1907/2006, RoHS 2011/65/EU for the machine electrical system, and ASTM D3330/D3330M-04(2018) adhesion testing to establish replacement intervals. The dominant process failure mode is tape edge lift at the cylinder ends, which is controlled by the end overlap and by capping the exposed adhesive edge with a PTFE-glass pressure-sensitive strip. Terminal products include printed sportswear, flags, promotional banners, and sublimated polyester panels for soft signage.
Competitive Saint-Gobain CHR SG06-14(R) Premium Glass-PTFE Backing Silicone Adhesive Pressure Sensitive Tape prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
The Saint-Gobain CHR SG06-14(R) Premium Glass-PTFE Backing Silicone Adhesive Pressure Sensitive Tape is a roll-form composite that combines a woven fibreglass scrim saturated with polytetrafluoroethylene with a silicone pressure-sensitive adhesive on one face. The construction provides a fluoropolymer release surface without the elongation and tear propagation of unsupported skived PTFE. The (R) designation is part of the product identifier and should be verified against the manufacturer’s certificate of analysis because suffix variants can differ in liner configuration or surface grade. Procurement specifications normally reference the full product code and roll dimensions rather than descriptive trade names.
The composite is supplied in total thickness values typically within 0.14 mm ± 0.02 mm when measured under ASTM D3652/D3652M-20. Backing tensile strength and elongation are evaluated using ASTM D3759/D3759M-05; published product-family data indicate a backing tensile strength of not less than 175 N/cm and an elongation at break below 5%, although independent published certificate data for this specific suffix is limited. Peel adhesion to stainless steel at 180° and 300 mm/min crosshead speed is reported under ASTM D3330/D3330M-10 in the 5.0 N/25 mm to 7.5 N/25 mm band. These mechanical values distinguish the glass-PTFE composite from unsupported skived PTFE, which commonly exhibits substantially higher elongation and lower tensile strength than reinforced glass fabrics.
Dielectric breakdown voltage is assessed on a short-time basis using ASTM D149-20; published values for glass-PTFE silicone adhesive tapes in this thickness class typically exceed 5 kV total construction. The continuous service temperature range is specified from -73 °C to 260 °C; the upper limit is governed by the onset of PTFE decomposition and silicone adhesive hardening, not by the glass fabric alone. Intermittent exposure above 260 °C is not recommended because PTFE evolves toxic degradation products and the silicone adhesive crosslinks to a friable residue, reducing reworkability on heated seals.
| Property | Test method | Published typical value |
|---|---|---|
| Total tape thickness | ASTM D3652/D3652M-20 | 0.14 mm ± 0.02 mm |
| Backing tensile strength | ASTM D3759/D3759M-05 | ≥ 175 N/cm |
| Backing elongation at break | ASTM D3759/D3759M-05 | ≤ 5% |
| 180° peel adhesion to stainless steel | ASTM D3330/D3330M-10 | 5.0–7.5 N/25 mm |
| Short-time dielectric breakdown | ASTM D149-20 | > 5 kV total |
| Continuous service temperature | Manufacturer thermal rating | -73 °C to 260 °C |
For applications requiring electrical insulation certification, the composite is evaluated under ASTM D1000-17 where the glass-PTFE backing and silicone adhesive are considered as a pressure-sensitive electrical tape system. Volume resistivity and surface resistivity are obtained in accordance with ASTM D257-14, but these are not fixed design properties because the PTFE surface can accept atmospheric moisture layers in high-humidity conditions, reducing surface resistivity. Preconditioning at 23 °C ± 2 °C and 50% ± 5% relative humidity for 24 h is required before dielectric measurements.
In heated-jaw film sealing and impulse sealing machines, the SG06-14(R) tape is applied to the sealing jaw face as a release interlayer. The woven fibreglass scrim resists tearing at the jaw edge under cyclic closing pressures of 0.4 MPa to 0.7 MPa; unsupported PTFE films under the same conditions frequently elongate and recede from the jaw edge after fewer than 500 cycles. The silicone adhesive maintains peel adhesion on chrome-plated steel jaws at 180 °C to 200 °C; above 220 °C adhesive ooze and edge lift become the dominant field failure modes. Production lines using corona-treated polyethylene or polypropylene webs at line speeds above 40 m/min require tape edge alignment within 0.5 mm to prevent adhesive transfer to the film edge.
Compared with polyimide tapes, the glass-PTFE composite has a lower temperature class and a thicker overall cross-section. Polyimide tapes can operate through soldering and wave-solder profiles at 288 °C to 316 °C for short dwells, while SG06-14(R) is limited to 260 °C continuous. The offset advantage is the fluoropolymer release surface: molten polyethylene, silicone rubber compounds, and plastisol residues release cleanly from the PTFE face, whereas polyimide surfaces may require additional release coating. Compared with conventional glass cloth silicone adhesive tapes without PTFE, the SG06-14(R) backing has a lower wetting tension, typically below 20 mN/m as determined by ASTM D2578-17, which reduces sticking of carbon-filled elastomers and low-molecular-weight resin deposits.
In vacuum-bag curing of thermoset composites, the tape serves as a release edge or flash tape on tool flanges. Autoclave processing at 180 °C and 0.7 MPa is within the adhesive’s service window; the PTFE surface allows cured epoxy bleeder material to separate from tooling without contamination transfer. The woven glass reinforcement prevents the tape from stretching under vacuum-induced shear at the bag edge, which is a known displacement mechanism for unsupported PTFE release films.
Production-scale rotary heat-sealing lines with induction-heated chrome-plated jaws have shown that the tape’s adhesive can retain tack after repeated exposure to temperature ramps from 30 °C to 200 °C at 8 °C/s, provided the jaw surface is degreased with isopropyl alcohol before installation. Silicone pressure-sensitive adhesives are known to release low concentrations of cyclosiloxane species at temperatures above 150 °C; in cleanroom packaging for medical devices this release may require post-seal ion-mobility spectrometry verification under ISO 14644-1 class limits. Edge lift on profiled sealing jaws is managed by applying the tape with a carrier tension of 8 N/cm to 12 N/cm and by using a crush-cut slitting operation that reduces glass fibre protrusion at the tape edge. Batch-to-batch glass weave density variation is controlled through incoming glass fabric compliance to ASTM D4029-19, but printed data for this specific tape configuration is limited.
Silicone adhesive migration is the principal limitation when SG06-14(R) is specified near painted or subsequently adhesive-bonded surfaces. Silicone oils deposited on adjacent metal or polymer surfaces produce a low-energy film that can prevent paint adhesion and is not removed by conventional solvent wipe alone. Where post-use adhesion or coating is required, the work area should be segregated and contamination verification conducted using ASTM D6281-15 for surface contamination or equivalent timed wicking methods. The PTFE backing itself is non-porous, but microcracks in the fluoropolymer coating over the glass weave can allow adhesive plasticiser and silicone fluid migration to the release face after long-term thermal ageing.
The exposed PTFE face has very low wettability, so adhesive lamination, printing, or painting directly onto the backing is not possible without surface activation. Corona discharge at 50 W·min/m² to 100 W·min/m² or sodium-naphthalenide etching can raise the surface energy temporarily, but the effect decays within hours to days depending on storage temperature and humidity. For this reason, the product is maintained as a roll good with a release liner when factory-applied pressure-sensitive features are required in secondary processing. Storage at 21 °C ± 3 °C and 50% relative humidity for up to 12 months from the date of manufacture is typical; high humidity above 60% RH requires desiccant storage because the glass scrim can absorb moisture through slit edges and reduce dielectric performance.
The tape should not be exposed to molten alkali metals, fluorine gas at elevated pressure, or strong oxidising acids at high temperature. Contact with acetaldehyde or vinyl chloride monomer streams in sealing applications may plasticise the silicone adhesive; in such cases chemical compatibility testing under ASTM D543-20 is required before line deployment. For food-contact use, the PTFE component may fall under FDA 21 CFR 177.1550 for perfluorocarbon resins, while silicone adhesive compliance must be verified against FDA 21 CFR 175.300 or 175.320, depending on the substrate and end-use conditions; published migration data for this specific tape is limited. End users are responsible for requesting regulatory letters from the manufacturer for each roll batch.
| Regulatory/standard area | Designation | Relevant condition |
|---|---|---|
| Electrical tape | UL 510 | Polymeric adhesive tape recognition; component-specific file data required |
| Peel adhesion | ASTM D3330/D3330M-10 | Stainless steel, 180°, 300 mm/min |
| Tensile and elongation | ASTM D3759/D3759M-05 | Backing direction |
| Dielectric breakdown | ASTM D149-20 | Short-time, applied 500 V/s |
| Glass fabric | ASTM D4029-19 | Weave stability |
| RoHS | Directive 2011/65/EU amended 2015/863 | Heavy metal thresholds by XRF screening |
| REACH | Regulation (EC) No 1907/2006 | SVHC content declaration from manufacturer |
| Food contact | FDA 21 CFR 177.1550 | PTFE component only; silicone adhesive must be verified separately |
In applications where the tape is used as slot insulation in rotating electrical machines, the backing’s tensile strength of not less than 175 N/cm enables mechanised insertion into stator slots without the tearing observed with thin aramid paper or skived PTFE interlayers. Insertion tension is controlled between 15 N and 25 N on wire-coil taping heads; at higher tensions, the glass weave can bunch at the slot entrance and cause dielectric voids. Mechanical edge stress from varnishing and coil pressing is therefore distributed across the scrim rather than concentrated in a homogeneous polymer film.
Dielectric performance in motor and transformer use depends on the absence of air entrapment between the adhesive and the conductor stack. Vacuum-pressure impregnation with epoxy or unsaturated polyester at 0.05 MPa to 0.10 MPa assists filling of the glass weave interstices; without impregnation, impulse breakdown can occur below the short-time ASTM D149-20 value because of partial discharge across trapped air. End-of-line surge testing under IEC 60034-15 or IEEE 522 may therefore show a reduction in withstand voltage when the tape is used dry in high-voltage coils. The manufacturer’s data for impregnated coil configurations is limited; prototype-level testing at the intended voltage class is required.
Slitting logs to narrow widths below 12 mm can introduce exposed fibre ends at the slit edge. Ultrasonic slitting with a 20 kHz to 40 kHz horn and crush-cut rotary knife systems produce cleaner edges than shear slitting because the glass monofilament ends are captured by the fluoropolymer layer. Failure to control slit edge fuzz is a known root cause of adhesive contamination on adjacent circuit traces in electrical assembly operations.