| HS Code | 560623 |
| Material Type | Polybutylene terephthalate (PBT), flame-retardant |
| Reinforcement | Unreinforced |
| Density | 1.31 g/cm³ |
| Melt Volume Flow Rate | 9 cm³/10 min (250 °C/5 kg) |
| Tensile Modulus | 2400 MPa |
| Tensile Stress At Break | 50 MPa |
| Tensile Strain At Break | 20% |
| Flexural Modulus | 2300 MPa |
| Flexural Strength | 80 MPa |
| Notched Izod Impact Strength | 5 kJ/m² |
| Heat Deflection Temperature At 0 45 Mpa | 150 °C |
| Heat Deflection Temperature At 1 82 Mpa | 65 °C |
| Ul 94 Flammability Rating | V-0 at 0.75 mm |
| Glow Wire Flammability Index | 960 °C |
| Dielectric Strength | 17 kV/mm |
| Volume Resistivity | >1E15 Ω·cm |
| Water Absorption | 0.07% |
| Mold Shrinkage | 1.7–2.0% |
| Uv Stabilization | Yes |
As an accredited SABIC VALOX™ PBT-FR 357U-1001 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | SABIC VALOX™ PBT-FR 357U-1001 is packaged in 25 kg sealed moisture-barrier bags, palletized for secure storage and transport. |
| Container Loading (20′ FCL) | Loaded in a 20′ FCL container, SABIC VALOX™ PBT-FR 357U-1001 is palletized and secured for safe ocean transport. |
| Shipping | SABIC VALOX™ PBT-FR 357U-1001 is not regulated as dangerous goods for transport (no UN number, hazard class, or packing group). Ship in dry, sealed bags/containers at ambient temperature; protect from moisture, contamination, and excessive heat. Follow the SDS and applicable local transport regulations. |
| Storage | Store SABIC VALOX™ PBT-FR 357U-1001 in a cool, dry, well-ventilated area away from direct sunlight, heat sources, and moisture. Keep containers tightly closed when not in use to prevent contamination and moisture pickup. Avoid contact with incompatible chemicals and dust generation. Follow local regulations and the product SDS for specific storage requirements and shelf life. |
| Shelf Life | SABIC VALOX PBT-FR 357U-1001 has a 2-year shelf life from manufacture when stored dry in original packaging. |
In production-scale molding of thin-wall connector housings using VALOX™ PBT-FR 357U-1001, the processing window is defined less by melt flow than by the competing requirements of complete cavity filling at wall sections of 0.80 mm and flame-retardant retention during barrel idle periods. On a 120-ton hydraulic injection molding machine fitted with a 22:1 L/D general-purpose screw, an eight-cavity connector body tool with pin retention ribs requires a fast injection velocity of 50–70 mm/s screw advancement to fill thin sections before solidification. Barrel temperatures are profiled from 245°C in the hopper zone to 260°C at the nozzle. Melt residence time is limited to 6 min at full temperature because the flame-retardant package undergoes measurable decomposition above 260°C, shifting UL 94 performance from V-0 at 0.71 mm to lower values in lot-specific testing. Pellets are pre-dried at 120°C for 3–4 h in a desiccant dryer with dew point not above -30°C; residual moisture above 0.02% by Karl Fischer titration reduces molecular weight during plastication, producing surface streaking and lowering tensile strength under ISO 527-2. Regrind of this grade may be added at a ratio not exceeding 10% by mass for connector bodies that must retain V-0 at 0.71 mm, provided the regrind is derived from sprues and short shots with no thermal degradation. Terminal retention force in the finished terminal block is governed by the copper alloy cage geometry, but the polymer boss must maintain insertion and pull-out forces after heat aging at 85°C for 500 h under IEC 60947-7-1. Knit lines at the boss base are moved away from retention features by adjusting gate location to a central edge gate and using a mold temperature of 40–60°C to prevent premature freeze-off. Compliance for user-facing connectors additionally includes glow-wire ignition testing according to IEC 60695-2-12 at 750°C; color concentrates must be limited to 2% let-down by mass and validated for glow-wire performance because organic pigments can reduce ignition resistance.
Coil bobbins produced from VALOX™ PBT-FR 357U-1001 are specified for transformer and solenoid applications up to insulation class F 155°C only when the complete insulation system is qualified under UL 1446 with the grade listed in the system file; published data for this specific grade in class H 180°C systems is limited. The limiting factor in impulse winding is not short-term tensile strength but creep under repeated hoop stress. Unfilled flame-retardant PBT is typically characterized by a tensile creep modulus that declines rapidly above 70°C; therefore winding tension is set so that the resulting hoop stress does not exceed 20 MPa at the winding temperature, and this value must be confirmed for the specific wall section because no uniform ISO data exists for thin-walled bobbin flanges. The grade is injection molded with a melt temperature of 245–260°C and mold temperature of 40–60°C; after ejection, bobbins are annealed at 90–100°C for 2–4 h to increase crystalline order and reduce subsequent post-mold shrinkage by up to 0.1 percentage points when measured according to ISO 294-4. Regrind is not recommended for fine-wire bobbins because contamination at a level as low as 0.5% by mass can cause conductor insulation damage during high-speed winding. Finished coil forms are checked for flange parallelism, inner diameter, and flash thickness; flash at the split line above 0.05 mm can cut 0.02 mm copper wire under NEMA MW 1000 winding tensions. The part is not recommended for direct soldering at the base unless a molded-in metal terminal is used, because local solder pot temperatures above 260°C produce surface melting and flame-retardant adduct migration.
Conversion from glass-filled unsaturated polyester to VALOX™ PBT-FR 357U-1001 for relay bases in high-voltage auxiliary circuits changes the dimensional tolerance stack after heat aging. The material is unfilled, so mold shrinkage is typically in the range of 1.5–2.0% along flow and 1.2–1.8% transverse, compared with 0.2–0.5% for a 30% glass-filled thermoset. This difference must be compensated in gate placement and packing pressure, which is maintained at 60–80 MPa hydraulic pressure during holding. Clearance and creepage distances required under IEC 60664-1 are verified on molded samples after 48 h annealing at 70°C, because post-mold crystallization shifts pin-to-pin distances by up to 0.1 mm in multi-gate tools. The flame-retardant system of this PBT grade may reduce comparative tracking index relative to non-FR polyester, so CTI is tested according to IEC 60112 on the actual plaque; if the CTI falls below 250 V, pollution degree 2 creepage distances are increased by the appropriate multiplier in IEC 60664-1 and the design is re-qualified. Regrind is limited to 15% by mass for relay bases not used in reinforced insulation, and only after re-testing flame retardancy and CTI on each lot. The recommended melt temperature is 250–260°C at the nozzle; hot-runner systems are operated with needle-valve shutoff because the low melt viscosity can cause drool at the gate. Finished relay bases are assembled with either press-fit or snap-fit terminal pins; press-fit interference should not exceed 0.20 mm radial for bosses without glass reinforcement, since higher interference induces stress cracking after thermal cycling between -40°C and 85°C under IEC 60068-2-14. The material is not recommended for continuous contact surface temperatures above 140°C; this limits its use in relay types where the coil wire temperature rise exceeds class F 155°C limits.
| Requirement | Standard / method | Typical design target / condition | Lot verification note |
|---|---|---|---|
| Flammability rating | UL 94 | V-0 at 0.71 mm | Confirm per color and thickness |
| Glow-wire ignition | IEC 60695-2-12 | 750°C pass for low-current connectors | Colorants can shift result |
| Comparative tracking index | IEC 60112 | 250 V minimum for reinforced insulation designs | Test at minimum wall thickness |
| Dielectric strength | IEC 60243-1 | ≥ 20 kV/mm at 1.5 mm typical for unfilled PBT | Test on molded plaque |
| Ball-pressure resistance | IEC 60695-10-2 | 125°C indentation for socket bodies | Measure outside contact zone |
| RoHS recast | EU 2015/863 | Pb, Hg, Cd, Cr(VI), PBB, PBDE, DIBP, DEHP, BBP ≤ 0.1% by mass | Supplier declaration required |
For GU10 lamp sockets and twist-lock bases, the primary design constraint is not bulk flammability but the localized contact temperature on the brass pin receiver. VALOX™ PBT-FR 357U-1001 is used in GU10 lamp sockets where the contact pin receiver operates below a sustained skin temperature of 150°C; above that value, the unfilled PBT matrix undergoes progressive oxidative embrittlement and the flame-retardant package can migrate. The socket body is molded at 245–260°C with a mold surface temperature of 40–70°C; higher mold temperatures reduce residual stress but increase cycle time, and lower mold temperatures below 30°C produce a skin layer with reduced crystallinity that lowers dimensional stability under bulb insertion torque. For white or colored GU10 bases, titanium dioxide or color masterbatch is limited to 2% by mass because higher loadings can reduce the UL 94 V-0 rating at 0.71 mm and may influence glow-wire ignition behavior under IEC 60695-2-12 at 750°C. Terminal staking of brass pin receivers into the socket is performed after insert preheating to 80–100°C to avoid cold cracking around the insert; the insert-to-hole interference is limited to 0.10 mm radial for unfilled PBT. Finished sockets intended for luminaire use are evaluated for ball-pressure temperature according to IEC 60695-10-2; the indentation diameter is recorded after the ball-pressure test at 125°C for the base material, not at the brass contact. Regrind is kept below 10% by mass for sockets that are visible in the luminaire, because recycled material from degraded hotspots can produce surface gloss variation and lower tracking resistance.
Brush holder bodies and commutator ring supports in universal motors are molded with wall sections between 1.2 mm and 2.5 mm to balance arc resistance, stiffness, and fill pressure. VALOX™ PBT-FR 357U-1001 is processed at a melt temperature of 245–260°C; screw speed on a 20:1 to 24:1 L/D screw is held at 80–150 rpm and back pressure at 0.3–0.7 MPa to avoid localized shear heating above 260°C, which decomposes the flame-retardant package and reduces UL 94 V-0 performance at 0.71 mm. Carbon black masterbatch is added at 0.8–1.2% by mass for UV marking contrast and laser-marking legibility; higher carbon black levels can alter dielectric strength under IEC 60243-1 and should be validated. Regrind is excluded for arc-adjacent features within 5 mm of the brush spring or commutator surface because degraded polymer from previous heat-aging can promote carbonization under arc exposure; virgin resin is required in these zones, while regrind up to 15% by mass may be used in non-arc structural bosses if UL 94 is re-verified per lot. Arc resistance of unfilled flame-retardant PBT is finite, with published values for unfilled PBT base resin often falling in the range of 50–130 s under ASTM D495; for brush holders in universal motors with stall currents above 15 A, additional ceramic arc barriers or reinforced thermoset inserts are required. The finished brush holder is heat-aged at 120°C for 1000 h according to IEC 60335-1 for motor-operated appliance applications, and screw torque retention is required to remain above 70% of initial value at the mounting boss.
Internal frames and arc shields in miniature circuit breakers are not continuous insulators under load; they absorb heat from the bimetal strip and the coil, and dimensional change in the frame can shift contact alignment. VALOX™ PBT-FR 357U-1001 may be used for frames in devices rated below 32 A where the molded-in metal insert temperature does not exceed 100°C during steady-state operation; above 100°C, the creep modulus of unfilled PBT falls rapidly, and screw-torque bosses lose clamp load. The frame is molded at 250–260°C melt temperature with a mold temperature of 50–70°C; packing pressure of 70–90 MPa is applied for 3–5 s to minimize sink around inserts. Post-mold annealing at 90°C for 4 h stabilizes the crystalline structure and reduces subsequent bowing when exposed to temperature cycling from -40°C to 85°C under IEC 60068-2-14. Regrind is not permitted in arc-chamber frames because any contaminant can create a carbonization path; virgin resin is specified for all components within 3 mm of the arc contact zone. The material carries UL 94 V-0 at 0.71 mm, but breaker standards often require glow-wire flammability at 850°C or 960°C for unattended appliance inlets; unfilled PBT alone may not pass the 960°C glow-wire ignition test, so metallic arc chutes or barrier partitions are required between live parts and the polymer frame. The complete breaker is evaluated under IEC 60898-1 or UL 489; the polymer frame is treated as part of the support insulation system, and CTI per IEC 60112 must be verified at the minimum wall thickness and maximum regrind level.
Battery interface housings for cordless power tools present a low-temperature impact load with a high-frequency vibration profile that is not well captured by standard tensile data. VALOX™ PBT-FR 357U-1001 is applied in power tool battery interface housings where flame retardancy and dimensional control are required, but the unfilled grade has a notched Izod impact strength in the low-temperature range that is documented as limited; published data for notched Izod at -30°C for this exact formulation is limited. The application is therefore designed with generous corner radii, rib spacing not less than 2.5 mm wall thickness, and mechanical support from the tool housing rather than relying on the polymer alone for drop survival. Molding is conducted at 245–260°C melt temperature with a mold temperature of 40–60°C; fast injection is used to fill thin latch features, but shear rates at the gate are kept below 50,000 s⁻¹ to prevent flame-retardant degradation. Regrind is limited to 10% by mass for visible exterior components and 15% for internal frames, with moisture content controlled below 0.02% before molding. The finished housing is subjected to IEC 60068-2-75 fall-ball impact at the energy level specified by the product standard, commonly 0.50 J for small consumer electronics, and at -20°C for components that must survive end-user handling. Cracks at gate vestige or weld lines have been observed in production when the mold temperature is below 40°C or when the hot runner has a cold slug at the valve gate. The part is not recommended for use in direct contact with lithium-ion electrolyte leakage because carbonate-based electrolytes can swell the amorphous phase of PBT; a sealed battery pack with the interface outside the electrolyte compartment is the design boundary.
In low-voltage appliance connectors exposed to occasional condensation, VALOX™ PBT-FR 357U-1001 is selected only when the connector body is rated for pollution degree 2 environments under IEC 60664-1. The unfilled flame-retardant PBT absorbs moisture slowly; after 24 h immersion at 23°C, the weight increase is typically less than 0.1%, but this must be confirmed on the actual thin-wall connector because moisture uptake increases the dielectric loss factor and can reduce comparative tracking index under IEC 60112. Molding conditions are set to 250–260°C melt temperature and 40–70°C mold temperature; the connector is annealed at 80°C for 2 h before electrical testing to remove residual stresses that can cause stress cracking in the snap-fit under high-humidity exposure. Color matching for appliance connectors often requires custom masterbatch at 1–2% by mass; only heat-stable masterbatch carriers based on the same PBT chemistry are allowed, because low-molecular-weight carriers reduce UL 94 V-0 performance at 0.71 mm. Regrind from damp or aged parts is rejected; only dry regrind from virgin sprues and runners is used at a maximum of 10% by mass and only after lot-specific UL 94 and IEC 60112 re-qualification. Terminal retention is verified after a modified humidity exposure at 40°C and 93% relative humidity for 21 days under IEC 60068-2-78; connectors that show surface exudation after this test are not shipped, because exudation indicates flame-retardant package incompatibility with the colorant or processing conditions. The grade is not recommended for connectors immersed in hot water above 60°C, as PBT hydrolysis accelerates under alkaline conditions, splitting at the snap-fit after repeated assembly cycles.
Competitive SABIC VALOX™ PBT-FR 357U-1001 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
SABIC VALOX™ PBT-FR 357U-1001 is an unreinforced, flame-retardant polybutylene terephthalate injection molding material compounded with a UV stabilization package. The product model designation separates this grade from general-purpose PBT homopolymers and from glass-fiber-reinforced PBT-FR systems. The “357U” family position refers to the flame-retardant and UV-resistant formulation; the “1001” suffix identifies a specific color/additive version within the VALOX 357U line. Because the compound contains a halogenated flame-retardant system typical of V-0 PBT grades, its melt rheology, moisture sensitivity, and thermal degradation envelope are narrower than those of an unfilled, non-flame-retardant PBT. Published datasheet values for melt flow index, mechanical properties, and thermal ratings must be treated as the controlling source for this exact suffix.
Primary usage fields include injection molded electrical and electronic components in which flammability classification, outdoor exposure, and moderate mechanical loading are simultaneous design constraints. These include relay bases, connector housings, switch components, lighting sockets, outdoor electrical enclosures, and circuit-protection devices. The product is not considered a low-halogen material; therefore, designs requiring halogen-free construction under IEC 61249-2-21 should not specify this grade. When material substitution from a non-UV PBT-FR is evaluated, the UV package of the 357U series may influence color retention, long-term surface integrity, and additive-related shifts in melt viscosity.
Drying is the first boundary condition on the molding floor. PBT hydrolyzes in the melt when moisture content exceeds 0.02 wt%, producing chain scission that reduces molecular weight, Charpy notched impact values, and surface quality. Desiccant drying at 120 °C for 3 h to 4 h, with supply air dew point at or below -30 °C, is the commonly cited window for PBT-FR compounds. Karl Fischer titration according to ISO 15512 should be used to verify that final moisture content is below the threshold before start-up. At plant relative humidity above 60 %, open hopper transfer time should be minimized, and airtight conveying with dry-air purge is recommended.
The melt processing range is bounded by the thermal stability of the flame-retardant package and the crystallization kinetics of the PBT matrix. Melt temperatures between 240 °C and 270 °C are typical for unreinforced PBT-FR. The lower boundary is set by incomplete homogenization, high screw torque, and poor mold filling; the upper boundary is set by progressive degradation of the flame-retardant additives, generation of volatile by-products, and discoloration. Mold temperature is normally held between 40 °C and 80 °C. Temperatures in the upper half of that range increase crystallinity, improve surface finish, and reduce post-mold shrinkage, but extend cycle time. Below 40 °C, rapid solidification can produce low knit-line strength, matte surface defects, and dimensional variability.
Screw speed and back pressure should be selected to limit shear heating. Standard low-to-medium compression screws with L/D ratios of 20:1 to 24:1 are generally suitable for unfilled PBT; back pressures from 0.3 MPa to 0.7 MPa are representative for shot-size stability. The use of hot runner systems requires internal runner temperatures that do not exceed 270 °C and avoidance of stagnation pockets where residence time can exceed 5 min to 10 min. Frequent purge cycles, low residual barrel materials, and shutdown procedures that reduce heat soak are necessary to prevent black specks and carbonized deposits in actual production lines.
Moisture absorption in unfilled PBT is low relative to polyamides, but surface condensation in outdoor enclosures can alter tracking behavior and leakage current paths. For insulation coordination under IEC 60664-1, the comparative tracking index assigned under IEC 60112 determines required creepage distances. Flame-retardant and UV additives can lower CTI relative to unmodified PBT; therefore, the CTI class for SABIC VALOX™ PBT-FR 357U-1001 should be taken from the current datasheet and mapped to the relevant pollution degree. Dielectric strength is thickness-dependent and is generally evaluated under IEC 60243-1 using either oil immersion or short-time testing. Volume resistivity should be evaluated according to IEC 62631-3-1 after standardized conditioning at 23 °C and 50 % relative humidity.
For outdoor use, UV stabilization addresses color fading and surface degradation, but electrical critical parameters may still require verification after xenon-arc exposure under ISO 4892-2. Glow wire tests under IEC 60695-2-12 are commonly requested for unattended appliance applications; these results depend on specimen thickness and the specific pigmentation in the 1001 suffix. Published values for this exact color/additive configuration are not always available in secondary literature, so the UL Yellow Card and SABIC datasheet are the controlling sources.
| Property or requirement | Standard designation | Operational note |
|---|---|---|
| Flammability classification | UL 94 | Thickness-dependent rating; check UL Yellow Card for V-0 at the targeted wall thickness |
| Glow wire flammability index | IEC 60695-2-12 | Treat values as thickness- and color-specific; results can vary between natural and black formulations |
| Tensile stress at yield | ISO 527-1/-2 | Reported in the current SABIC datasheet; test speed and specimen type affect values |
| Flexural modulus | ISO 178 | Use dry-as-molded specimens; moisture conditioning can shift results |
| Charpy notched impact | ISO 179-1/1eA | Notched impact is sensitive to mold temperature and crystallinity |
| Heat deflection temperature | ISO 75-2/B | Unfilled PBT grades show lower HDT than glass-filled grades; short-term thermal data should be used cautiously |
| Comparative tracking index | IEC 60112 | CTI class affects insulation coordination; consult datasheet for tested solution A or B |
| Dielectric strength | IEC 60243-1 | Thickness-dependent; thin-wall parts may require oil immersion testing |
| Volume resistivity | IEC 62631-3-1 | Relevant for connector housings and relay bases |
| UV weathering | ISO 4892-2 | UV package is intended for color retention; thermal and humidity cycles may be tested separately |
The principal structural difference is the UV stabilization system. A standard unfilled PBT-FR grade can meet the same UL 94 V-0 flammability classification but may not contain the UV absorber and hindered-amine stabilizer combination required for extended outdoor exposure. The 1001 suffix adds a formulation-specific pigment or additive identity, which can influence melt flow, elongation at break, and color stability under ISO 4892-2 weathering cycles. In molded parts, this means the 357U series may show reduced surface chalking and less color shift when exposed to ultraviolet radiation, although the degree of protection remains dependent on part geometry and total UV dose.
Compared with non-flame-retardant unfilled PBT, the 357U series exhibits higher specific gravity because of the halogenated flame retardant and synergist package. Published values for similar unfilled PBT-FR grades fall roughly between 1.40 g/cm³ and 1.50 g/cm³, whereas unfilled unmodified PBT is commonly reported near 1.31 g/cm³. This density increase is a specification input and a cost-per-volume consideration, not a direct mechanical performance gain.
Compared with glass-fiber-reinforced PBT-FR compounds, the unreinforced 357U grade trades stiffness and dimensional stability for higher flow length, lower melt viscosity, reduced fiber-induced anisotropy, and generally better surface appearance in smooth cosmetic areas. Glass-filled PBT-FR offers lower coefficient of linear thermal expansion and higher tensile modulus, but the fiber orientation can create differential shrinkage and warpage in complex thin-wall geometries. For small connectors and relay bases where long flow paths and tight dimensional tolerances coexist, the unreinforced grade can be preferred when UL 94 compliance and UV resistance are required but high structural load is not the dominant design variable.
The material is subject to Restriction of Hazardous Substances evaluations under 2011/65/EU and, where applicable, to reporting under Regulation (EC) No 1907/2006 for substances of very high concern. It contains a halogenated flame retardant; therefore, it is not suitable for halogen-free requirements under IEC 61249-2-21 or equivalent low-halogen clauses. The halogenated system also requires segregated recycling streams and controlled pyrolytic or incineration conditions. In service, the product should not be exposed to strong alkalis, hot concentrated acids, or high-pressure steam above 80 °C, because these conditions accelerate ester hydrolysis and can produce surface erosion and loss of dielectric integrity. Avoid compounding with aromatic amines or organotitanate additives that may interact with the flame-retardant system; any custom color or additive masterbatch must be validated for UL 94 re-certification and thermal aging performance under UL 746B.
In connector housings with wall thicknesses below 1.0 mm, the selection of an unreinforced PBT-FR such as SABIC VALOX™ PBT-FR 357U-1001 is often driven by fill speed and weld-line integrity rather than absolute tensile strength. High injection velocity, short hold pressure transition, and gate sizing appropriate for the shear-thinning behavior of the melt prevent premature freeze-off. Because the flame retardant reduces thermal stability, barrel residence time at melt temperature should not exceed the maximum recommended by SABIC; repeated cycling of small shot volumes in a large barrel causes degradation from extended residence and can shift the UL 94 performance of thin sections.
Insert molding and encapsulation of electrical contacts require a low-pressure stage and adequate venting to avoid corrosion of tool steel from acidic volatiles released by the flame retardant. Tool surfaces in contact with the melt benefit from corrosion-resistant steel when running unfilled PBT-FR. Where dimensional consistency is evaluated, mold shrinkage in unfilled PBT-FR is higher than in glass-filled grades and must be measured on actual runner/cavity configurations rather than taken from generic tables. The addition of UV stabilizer does not eliminate the need for proper mold temperature control; nonuniform tool temperature produces differential crystallization and can increase warp even in unreinforced material.
When part function includes prolonged outdoor exposure, UV resistance is not a substitute for mechanical reinforcement. The 357U grade provides flame-retardant performance and weather-resistant stabilizer chemistry, but tensile and impact properties fall within the unreinforced PBT range. Design calculations should use current datasheet values and account for reduced weld-line strength in snap-fit or thin-web geometries. The operational boundary for this product is therefore defined by the intersection of the UL 94 V-0 thickness rating, the validated moisture-control procedure, and the thermal aging limits established under UL 746B for the specific color and additive configuration of SABIC VALOX™ PBT-FR 357U-1001.