Sabic Valox Pbt Fr 357 Bk1066

SABIC VALOX™ PBT-FR 357 BK1066

    • Product Name: SABIC VALOX™ PBT-FR 357 BK1066
    • Factroy Site: Yinchuan, Ningxia, China
    • Price Inquiry: sales8@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 525948
    Polymer Type Polybutylene terephthalate (PBT)
    Grade Designation VALOX 357 BK1066
    Color Black
    Reinforcement 30% glass fiber
    Flame Retardancy Flame retardant
    Ul94 Rating V-0 at 0.75 mm
    Molding Shrinkage Flow Percent 0.3-0.5
    Molding Shrinkage Crossflow Percent 0.6-0.8

    As an accredited SABIC VALOX™ PBT-FR 357 BK1066 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Packaged in 25 kg bags on pallets, labeled with product name, grade, batch, and safety information.
    Container Loading (20′ FCL) 20′ FCL: palletized 25 kg bags of SABIC VALOX™ PBT-FR 357 BK1066, stretch-wrapped and securely stowed for ocean shipment.
    Shipping SABIC VALOX™ PBT-FR 357 BK1066 is supplied as black thermoplastic pellets in sealed moisture-barrier bags or octabins, palletized and stretch-wrapped. Ship in cool, dry, ventilated conditions away from direct sunlight and ignition sources. Handle according to the SDS; classify and label per local transport regulations.
    Storage Store SABIC VALOX™ PBT-FR 357 BK1066 in a dry, cool, well-ventilated area away from direct sunlight, heat, ignition sources, and moisture. Keep containers tightly closed, clearly labeled, and protected from physical damage. Avoid contact with incompatible chemicals such as oxidizers, acids, and bases. Prevent dust accumulation, use appropriate containment, and follow the manufacturer’s SDS and local regulations.
    Shelf Life SABIC VALOX™ PBT-FR 357 BK1066 has a 24-month shelf life when stored unopened at 10–30°C, protected from moisture and sunlight.
    Application of SABIC VALOX™ PBT-FR 357 BK1066

    Low-voltage switchgear terminal blocks and DIN-rail carrier components use SABIC VALOX™ PBT-FR 357 BK1066 as a neat, unfilled flame-retardant polyester with 0 wt% glass or mineral reinforcement, which keeps flange ductility high enough for cold-staked metal screw inserts. The granulate is dried in a desiccant-hopper dryer at 120°C for 4 h to 6 h; residual moisture above 0.02% produces surface splay and hydrolysis at melt temperature. Barrel set-points are maintained from 250°C to 270°C, mold surface temperature is held at 80–100°C, and screw back pressure is limited to 0.3–0.7 MPa to avoid shear-induced heat rise in the brominated flame-retardant package. The grade carries a UL 94 V-0 listing at 1.5 mm, but this material-level rating does not automatically classify the finished terminal block; the end product must be evaluated under UL 94 or equivalent end-product standard because metal screw mass and thin-section walls function as flame sinks and propagation paths. IEC 60947-7-1 governs terminal block type testing, including dielectric withstand, impulse voltage, and current-cycling tests; IEC 60664-1 defines creepage and clearance distances that are then verified on the molded geometry. The comparative tracking index under IEC 60112 must be confirmed on the production part because brominated FR packages can shift CTI downward relative to non-FR PBT. Regrind addition is capped at 15 wt% in terminal block production, and only cleaned, uncontaminated runners from the same black grade are reused. Finished articles include screw-terminal blocks, knife-disconnect terminals, fuse terminal carriers, and relay sockets mounted on 35 mm DIN rail.

    Process variableThin-wall ≤ 1.5 mmThick-wall 2.0–3.0 mm
    Desiccant drying120°C for 4–6 h120°C for 4–6 h
    Melt temperature250–270°C250–265°C
    Mold temperature80–100°C90–100°C
    Screw back pressure0.3–0.7 MPa0.3–0.5 MPa
    Cushion3–5 mm5–8 mm
    Regrind limit15 wt%10 wt%

    Does glow-wire end-product testing shift material selection for household appliance connectors?

    For appliance connectors used in washing machines, dishwashers, water heaters, and cordless kitchen devices, the regulatory threshold is IEC 60335-1:2020 clause 30.2, which can require glow-wire testing at 750°C for unattended appliances carrying more than 0.5 A and at 850°C for certain high-current or unattended conditions. SABIC VALOX™ PBT-FR 357 BK1066 is processed as a neat resin; adding glass fiber at any letdown ratio is avoided because glass-filled surfaces can produce conductive tracks under glow-wire exposure and change the end-product ignition result. The connector housing is gated through a valve-gated hot runner, and weld lines are deliberately relocated away from the live-part separation wall because weld lines reduce the effective glow-wire ignition temperature of the molded part. Melt temperature is set at 255–270°C, mold temperature at 80–100°C, and the screw cushion is held at 3–5 mm to maintain consistent packing pressure across multi-cavity tools. Wall sections are kept at 1.5 mm minimum unless the end-product standard allows a thinner section supported by additional glow-wire data. Material-level GWFI is measured under IEC 60695-2-12, while GWIT is measured under IEC 60695-2-13; neither substitutes for the end-product glow-wire test under IEC 60695-2-11 because contact pins and brass terminal mass extract heat from the polymer. CTI testing under IEC 60112 is performed after molding, and a CTI value of 250 V is typical for this category of brominated FR PBT; designers should not assume a higher tracking class without lot-specific data. Terminal products include appliance terminal strips, timer bases, door-lock connector housings, and sensor sockets.

    Thermal aging in under-hood fuse boxes changes the allowable wall-stock calculation.

    Engine-compartment fuse and relay boxes molded from VALOX™ PBT-FR 357 BK1066 are exposed to continuous temperatures above 85°C in regions adjacent to the exhaust manifold and turbocharger. Because the grade is unfilled, its deflection temperature under 1.82 MPa is not the governing design limit; long-term heat resistance is assessed through the UL 746B relative thermal index shown on the product certification. The electrical RTI is generally higher than the mechanical impact RTI for this material class, so the lower value must govern when a housing is under mechanical load. Housing wall stock is designed from 2.0 mm to 3.0 mm, and the main process defect is sink marks above internal bosses. Packing pressure is therefore held above 60 MPa, hold time is extended to 10–15 s, and mold temperature is set to 90–100°C to reduce post-mold shrinkage. Unfilled PBT mold shrinkage is 1.5% to 2.0% in the flow direction and 1.7% to 2.2% transverse, so tooling must compensate for the asymmetry. Structural ribs use a base-to-wall ratio not exceeding 0.6:1 to prevent visible sink on exterior surfaces. Automotive validation follows USCAR-2 for electrical connector systems plus OEM thermal cycling profiles from −40°C to 125°C; a warp target of less than 0.2 mm over 150 mm span is commonly applied to ensure blade-terminal alignment after cycling. Regrind is limited to 10 wt% because thermal aging of previously processed material reduces the UL 746B performance margin. Finished assemblies include power distribution boxes, relay boxes, and front-end fuse carriers with sealing features.

    Relay coil bobbins and contactor coil formers use the unfilled FR PBT grade to avoid glass-fiber abrasion on fine enameled copper wire. The core pin is cooled to 80–100°C while the cavity is held at 90–110°C; this differential controls bore diameter in a long, thin annular fill. Winding tension for wire diameters below 0.1 mm is limited to 0.3–0.5 N because the unfilled surface has lower stiffness than glass-reinforced PBT and can deform under local pressure. UL 1446 insulation system recognition applies, meaning the bobbin is tested with the magnet wire, interlayer insulation, and varnish as a system, not as an isolated material; long-term thermal aging at three or more temperatures determines the insulation class. Process parameters are constrained to reduce internal stress: barrel temperatures are held at 250–260°C, mold temperature at 90–100°C, and injection speed is profiled to fill the thin annulus without jetting. Post-molding annealing at 120°C for 2 h is used to stabilize bore dimensions before winding. The material is processed as a neat formulation; external mold release agents are excluded from winding surfaces because they degrade adhesion of impregnating varnish. End products include telecom relay bobbins, contactor coil formers, and solenoid plunger guides.

    When short-circuit test duty governs miniature circuit breaker internal arc barriers

    Miniature circuit breakers tested under IEC 60898-1 or UL 1077 expose internal arc barriers to high-pressure arc gas and localized contact heating during interruption. VALOX™ PBT-FR 357 BK1066 is used for arc chamber side walls and static contact carriers because the unfilled grade delivers precise slot dimensions at multi-cavity volumes with lower tool wear than glass-filled material. The decisive material property after interruption is tracking resistance under IEC 60112; brominated FR PBT typically exhibits a CTI near 250 V, which forces a creepage distance of at least 6 mm for 230/400 V rated equipment unless additional ribbing or slotting is introduced. Barrel temperatures are kept in a flat profile from 245°C to 260°C, measured melt temperature is not allowed to exceed 270°C, and residence time is limited to 8 min to prevent decomposition of the flame-retardant system into black specks and gate blush. Mold temperature is set at 90–100°C to reduce shrinkage in the arc-chamber slot dimensions. The material is used neat; glass fiber addition would raise stiffness but create carbonized tracks along fiber-matrix interfaces under arc exposure. Regrind is limited to 10 wt% and only from clean breaker production campaigns. Terminal products include MCB arc chambers, residual current device housings, and auxiliary contact bases where the same FR PBT supports PCB isolation.

    EVSE charge coupler housings and thermal cycling after high-current derating

    Electric vehicle supply equipment internal insulating carriers and pilot-pin supports are subject to IEC 62196-2 and, in North America, UL 2251. The unfilled PBT grade is not specified for the main structural charge coupling shell; its use is restricted to control pilot pin carriers, low-voltage terminal retainers, and insulating sleeves. End-product compliance requires dielectric withstand at 2.5 kV or higher for the assigned circuit voltage, insulation resistance greater than 5 MΩ after thermal cycling, and glow-wire end-product assessment under IEC 60695-2-11 when the part is mounted in a non-metallic enclosure. The injection mold must compensate for unfilled-PBT shrinkage of 1.5–2.0% in pin-hole diameter; after cycling from −40°C to 85°C, bore shrinkage can increase terminal insertion force beyond the assembly specification. Drying at 120°C for 4 h, melt temperature of 255–270°C, and mold temperature of 80–100°C are used. Weld lines in the circular pilot-pin array are moved to the outer circumference by sequential valve gating because knit lines around pin holes crack during terminal insertion. Published test data for this exact grade in high-current EVSE thermal propagation sequences is limited; material-level UL 94 V-0 at 1.5 mm cannot be substituted for end-product flame exposure validation under IEC 62196-1:2022.

    Application segmentEnd-product standardMaterial-level testCritical numerical criterion
    Low-voltage terminal blocksIEC 60947-7-1UL 94 V-01.5 mm wall; 2.5 kV dielectric withstand
    Appliance connectorsIEC 60335-1:2020 cl. 30.2IEC 60695-2-12 GWFI750°C / 850°C glow wire
    Under-hood boxesUSCAR-2UL 746B RTI−40°C to 125°C cycling
    Relay bobbinsUL 1446UL 94Insulation class per system testing
    MCB arc barriersIEC 60898-1, UL 1077IEC 60112 CTICTI 250 V; creepage 6 mm
    EVSE carriersIEC 62196-1:2022, UL 2251UL 94 V-02.5 kV withstand; 5 MΩ IR
    Free Quote

    Competitive SABIC VALOX™ PBT-FR 357 BK1066 prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    VALOX™ PBT-FR 357 BK1066 is an unfilled flame-retardant polybutylene terephthalate injection-moulding grade supplied in black. The model designation separates the base polymer class from the flame-retardant system (FR) and the formulation number (357), while BK1066 identifies the black colour package. The unfilled grade is specified for electrical connectors, relay housings, terminal blocks, circuit-breaker internal frames and power distribution components where flame classification is required without glass or mineral reinforcement. Mechanical and rheological data are reported under ISO 527-1/2, ISO 178, ISO 1183-1, ISO 1133-1 and ISO 75-2/A; the flame classification is assigned under UL 94 and the grade-specific UL Yellow Card states the minimum thickness and colour conditions. Published datasheet values for this unfilled FR-PBT class place flexural modulus in the region of 2500–2800 MPa and tensile stress at yield between 50–60 MPa. The grade should not be specified blindly for load-bearing structural replacements where glass-filled PBT-FR compounds are already qualified.

    What Limits Direct Substitution of VALOX PBT-FR 357 BK1066 for Glass-Filled PBT-FR Grades?

    Substitution into load-bearing connectors moulded from a 30% glass-fibre PBT-FR grade is constrained by the lower stiffness and heat deflection temperature of the unfilled material. In published comparative data, unfilled PBT-FR grades exhibit flexural modulus in the range 2500–2800 MPa under ISO 178, while 30% glass-reinforced PBT-FR grades routinely reach 7500–8500 MPa. Corresponding tensile stress at yield moves from approximately 115–130 MPa for 30% glass reinforcement to 50–60 MPa for the unfilled product. Heat deflection temperature under 1.82 MPa is below 70°C for the unfilled grade, whereas glass-filled variants often exceed 195°C. The process advantage is reversed for dimensional stability in flat connectors: unfilled PBT-FR grades have higher mould shrinkage but lower shrinkage anisotropy than glass-filled compounds. The unfilled grade is preferred when flatness, low warpage, chemical toughness and consistent surface finish outweigh structural stiffness. Direct replacement without mechanical redesign is not recommended for snap-fit arms or bosses originally designed at glass-filled strength levels.

    Before melt processing on a production-scale injection-moulding line, the limiting variable is hydrolysis control rather than melt flow. PBT is sensitive to humid storage; when pellets are fed with residual moisture greater than 0.02% by weight, the melt temperature range of 245–265°C drives ester hydrolysis that reduces molecular weight and causes brittle parts, surface splay, and loss of flame-retardant rating at the moulded surface. Dehumidifying hopper drying at 120°C for 3–4 hours is the standard preparation, with a drying-air dew point of -30°C or lower. The material should not be left in the hopper at elevated temperature for more than 6–8 hours without verification of residual moisture. A general-purpose screw with L/D ratio of 18:1 to 25:1 and a compression ratio of 2.5:1 to 3.5:1 is adequate; high-shear barrier screws may generate local temperatures above 280°C and initiate flame-retardant degradation. Mould temperature should be maintained between 65–95°C to avoid visible delamination and to allow crystalline skin formation. Back pressure of 0.3–0.7 MPa and moderate screw speed favour homogeneous melt temperature; excessive shear raises the risk of yellowing and mould deposits from the flame-retardant system. Vent depth for PBT should not exceed 0.02 mm, and vents must be cleaned at intervals consistent with the observed deposit rate.

    Dimensional Stability and Shrinkage Anisotropy in Unfilled Flame-Retardant PBT

    Grades free of glass and mineral reinforcement exhibit shrinkage values that are larger in magnitude but more balanced in direction than reinforced alternatives. Mould shrinkage measured according to ISO 294-4 typically lies between 1.8% and 2.0% in flow direction for unfilled FR-PBT; transverse values are generally within 0.2 percentage points of the flow value. The low anisotropy reduces residual stress gradients that cause bowing in flat electrical connectors. In multi-cavity tools transferred from glass-filled PBT, the greater volumetric shrinkage of VALOX PBT-FR 357 BK1066 requires revision of gate sizing and packing profiles. Holding pressure must be increased, or gate freeze time adjusted, because the unfilled melt does not contain glass fibres that create stress-bearing chain entanglement at the frozen layer. Sprue, tab, or edge gates with a minimum gate depth of 50–60% of wall thickness are preferred for packing; pin gates smaller than 0.8 mm diameter may freeze before sufficient hold pressure is delivered. Cold-slug wells should be designed into full-round or trapezoidal runner systems to prevent solidified material from reaching the cavity and disrupting knit-line strength.

    Comparative published property ranges for unfilled FR-PBT, 30% glass-filled FR-PBT, and unfilled non-FR PBT are summarised below.

    Property / methodVALOX PBT-FR 357 BK1066 class30% glass-filled FR-PBT classUnfilled non-FR PBT class
    Density (ISO 1183-1)1.45–1.50 g/cm³1.52–1.60 g/cm³1.30–1.32 g/cm³
    Tensile stress at yield (ISO 527-1/2)50–60 MPa115–130 MPa55–60 MPa
    Flexural modulus (ISO 178)2500–2800 MPa7500–8500 MPa2300–2600 MPa
    Heat deflection temperature at 1.82 MPa (ISO 75-2/A)55–70 °C195–210 °C50–60 °C
    UL 94 classV-0 at listed thicknessV-0 at listed thicknessHB
    Mould shrinkage flow (ISO 294-4)1.8–2.0 %0.3–0.5 %1.8–2.2 %

    Because the UL 94 V-0 classification is assigned to a specific thickness and colour, moulders must verify that the listed minimum thickness is present in the final part, particularly at weld lines and thin snap-fit features. IEC 60695-11-10 is the test basis for UL 94; glow-wire tests according to IEC 60695-2-12 and IEC 60695-2-13 are application-level, not material-level tests. A material that passes UL 94 V-0 at 0.8 mm can still fail glow-wire at 750°C if the part design retains heat or if wall thickness varies. Published data for this specific grade in finished component geometry is limited; end-product testing is required for certification. Electrical insulation for unfilled PBT-FR is generally characterised by volume resistivity above 10^13 ohm·m and dielectric strength in the range 15–20 kV/mm, but comparative tracking index is grade- and colour-specific. For applications requiring CTI above 600 V, the grade-specific datasheet or UL Yellow Card must be consulted.

    When Thin-Wall Moulding Drops Below 0.8 mm and Flame-Retardant Margins Shrink

    At wall thickness below the UL-listed minimum, the flame-retardant system operates under a reduced thermal mass regime. The condensed-phase and gas-phase mechanisms responsible for extinguishment depend on the heat flux experienced by the specimen; thinner cross-sections reach thermal runaway more rapidly and may drip more readily. In production moulds with 0.4–0.5 mm connector walls, filling pressure may be lower than with glass-filled grades because the melt viscosity of unfilled PBT-FR is lower, but the flame classification cannot be assumed to transfer. Moulders should request a UL Yellow Card at the exact wall thickness and colour, or submit parts to UL 94 testing on the finished component. Gate location affects knit-line structure and local thickness at the flame ignition point; a knit line located near the bottom flame application zone can concentrate brittle fracture and alter burning behaviour. Published data for this specific configuration is limited, so end-use validation is mandatory. Melt residence time at high temperature should remain below 5 minutes for thin-wall applications to prevent viscosity plateau shifts from flame-retardant degradation. Plate-out from the flame-retardant system increases with surface-to-volume ratio in thin sections; mould venting and periodic tool cleaning become critical process controls.

    Regulatory Compliance Is Not Equivalent to End-Product Certification

    Compliance matrix for material-level and end-product evaluation:

    Compliance topicReference / methodStatus for VALOX PBT-FR 357 BK1066
    Flame resistanceUL 94 / IEC 60695-11-10V-0 at grade-specific thickness; Yellow Card controls minimum thickness.
    Glow wire ignitionIEC 60695-2-12End-product test required; no material-level inference.
    RoHS recast2011/65/EUSupplier declaration required; verify brominated FR chemistry.
    REACH SVHCEC 1907/2006Supplier declaration required.
    Food contactFDA 21 CFR 177.166Not supported without grade-specific written statement.

    Compliance documentation for VALOX PBT-FR 357 BK1066 must be read in the same context as flammability listing: the grade may support a declaration, but certification is assigned to the final article. The material is supplied as a black FR-PBT with documentation relevant to RoHS 2011/65/EU and REACH SVHC declarations; it is not a halogen-free compound. Any customer specification that requires IEC 61249-2-21 halogen-free criteria or equivalent is outside the intended application envelope. The flame-retardant system may produce acidic decomposition products above 280°C; moulds must be cleaned regularly to prevent corrosion on low-alloy tool steels. The material should not be blended with amine-based additives, which can interact with the flame-retardant package and reduce UL 94 performance or induce premature degradation. Avoid hydrolysis-prone service environments above 85°C in continuous hot water or alkaline chemical exposure; PBT is not recommended for hot-water plumbing components. Food-contact and medical device applications are not supported for this grade unless specific regulatory documentation is obtained from the supplier. No performance statement for repeated sterilisation, gamma irradiation, or autoclave exposure should be inferred.