    Specifications
    HS Code 142490
    Material Type Polybutylene terephthalate (PBT), flame retardant
    Glass Fiber Content 10%
    Color Black
    Density 1.45 g/cm³
    Tensile Modulus 5500 MPa
    Tensile Stress At Break 85 MPa
    Tensile Strain At Break 2.5%
    Flexural Modulus 5500 MPa
    Notched Izod Impact Strength At 23 C 6 kJ/m²
    Hdt At 1 8 Mpa 190 °C
    Hdt At 0 45 Mpa 205 °C
    Vicat Softening Temperature 210 °C
    Ul94 Flame Rating V-0 at 0.75 mm
    Comparative Tracking Index 600 V
    Dielectric Strength 20 kV/mm
    Volume Resistivity >1E15 Ω·cm
    Water Absorption 0.07%
    Mold Shrinkage Flow 0.4%

    As an accredited SABIC VALOX™ PBT-FR 310SEO BK1066 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing SABIC VALOX™ PBT-FR 310SEO BK1066 is supplied in 25 kg moisture-barrier bags, palletized for industrial handling and storage.
    Container Loading (20′ FCL) Container Loading (20′ FCL): SABIC VALOX™ PBT-FR 310SEO BK1066 in 25 kg bags, palletized, shrink-wrapped, and secured inside a 20-foot FCL container.
    Shipping SABIC VALOX™ PBT-FR 310SEO BK1066 is shipped as non-hazardous thermoplastic resin pellets, typically in moisture-barrier bags or octabins, palletized and stretch-wrapped. Keep dry and protected from direct sunlight and high temperatures; transport per SDS and local regulations.
    Storage Store SABIC VALOX™ PBT-FR 310SEO BK1066 in its original, sealed packaging in a cool, dry, well-ventilated area, away from direct sunlight, heat, ignition sources, and incompatible chemicals. Protect from moisture and contamination; avoid prolonged humid exposure. Keep containers closed, label clearly, and follow the manufacturer’s SDS and local storage regulations.
    Shelf Life For SABIC VALOX™ PBT-FR 310SEO BK1066, shelf life is typically 24 months from manufacture when stored dry in original sealed packaging at ambient temperature.
    Application of SABIC VALOX™ PBT-FR 310SEO BK1066

    Appliance board connectors and IEC 60335-1 glow-wire requirements

    The primary selection driver for appliance board connectors is the need to satisfy IEC 60335-1 clause 30.2.3 without shifting to a thermoset material that would increase cycle time and restrict connector geometry. SABIC VALOX™ PBT-FR 310SEO BK1066 is processed as a ready-to-mould compound with a published UL 94 V-0 classification at 0.71 mm; this thickness is relevant to connector walls, terminal separation barriers, and snap-fit latching features, but it does not automatically confer a pass on the final appliance assembly. End-product glow-wire testing under IEC 60695-2-12:2014 and ignition resistance under IEC 60695-2-13:2014 must be conducted on the moulded part at the wall thickness, terminal density, and mounting orientation found in the appliance, because thermal mass and terminal metal conduction alter the glow-wire thermal response in ways that a small plaque cannot reproduce.

    Drying is the first process boundary. The pellets are dried at 120 °C for 3 h to 4 h in a desiccant dryer with a −40 °C dew point, targeting a residual moisture content below 0.02 %. If ambient relative humidity exceeds 60 % and the material is exposed for more than 8 h, tray drying is repeated before moulding; hydrolysis at melt temperature causes surface splay, loss of tensile ductility, and a shift in flame-retardant distribution that can lower the effective UL 94 performance of thin connector walls. The melt is held between 245 °C and 260 °C, with the nozzle set no higher than 255 °C. Barrel residence time is controlled to ≤ 6 min, and shot size is maintained between 40 % and 60 % of barrel capacity; prolonged residence or excessive melt temperature degrades the flame-retardant system and generates black streaks in the BK1066 black matrix. Mould temperature is set at 60 °C to 80 °C; the higher value is required when the connector wall falls below 1.0 mm, because rapid cooling of unfilled PBT-FR reduces crystallinity and creates an inconsistent morphology at the gate land. Injection speed is set between 100 mm/s and 200 mm/s for thin-wall fill; holding pressure is maintained in the range of 40 MPa to 60 MPa at the cavity, with gate seal confirmed by part-weight stabilisation rather than timer-only transfer.

    Formulation is controlled by restricting dry blends. Because BK1066 already contains a full black colourant package and flame-retardant system, no additional halogenated flame-retardant masterbatch, antimony synergist, or organic colour concentrate is dry-blended on the shop floor. Regrind from sprues, runners, and rejected connectors is blended at a maximum of 20 wt % with virgin pellets, provided the regrind is clean, dry, and free of polyamide or PET contamination above 0.1 wt %. For terminal retention features in washing machine, dishwasher, and refrigeration control boards, the regrind fraction is reduced to 10 wt % when retention force capability falls below 1.33 CpK over three consecutive batches. Terminal products in this sector include IEC 60320 appliance inlet housings, motor control board connectors, relay bases, and flame-retardant terminal strips. The material is not recommended for direct use as an arc barrier in high-energy contact gaps; it functions as an insulating carrier behind metal terminals and contact assemblies.

    Standard / methodAssessmentApplication condition
    UL 94 V-0Flame classification at 0.71 mmGrade datasheet listing; verify on production part wall thickness
    IEC 60695-2-12:2014Glow-wire flammability indexApply with IEC 60335-1 clause 30.2.3.1 fault conditions
    IEC 60695-2-13:2014Glow-wire ignition temperatureSupporting data for unattended appliance connectors
    IEC 60112:2009Comparative tracking indexCreepage and clearance design for terminal blocks and relay bases
    UL 746BRelative thermal indexTemperature ageing near coils, PCB copper, and resistive loads
    IEC 60243-1:2013Electric strengthInsulating walls between adjacent connector pins

    Automotive underhood relay housings expose the polymer to thermal ageing, chemical contact, and insert-driven stress simultaneously. The moulded relay base and cover are located near the engine bay fuse block, where continuous air temperature can reach 125 °C and short-term excursions above 140 °C occur during heat soak. Because the grade is an unfilled PBT-FR, the mechanical load-bearing capability is lower than that of a glass-reinforced PBT, and bolted joint compression must be validated against torque retention after heat ageing per the vehicle manufacturer’s thermal cycling specification. The relevant long-term heat-ageing reference is the relative thermal index recorded in the UL Yellow Card under UL 746B; if the local relay base temperature exceeds the published electrical RTI, the application is outside the supported thermal envelope and a different polymer family or relay-to-fuse block isolation strategy is required.

    Insert moulding is the central process conflict. Brass relay terminals and connector blades are preheated to 100 °C to 120 °C before insertion; lower insert temperatures create sharp melt-freezing at the metal-polymer interface and produce latent stress that appears as cracking after thermal cycling. The mould temperature is held at 80 °C, and the melt temperature is kept between 245 °C and 255 °C. Gate land length is kept below 1.0 mm when filling walls of 1.2 mm to 2.0 mm, because extended land lengths raise shear heating and local flame-retardant degradation in the black compound. Holding pressure is set to maintain a cavity pressure of 45 MPa to 55 MPa for 4 s to 6 s after fill; insufficient hold creates sink over the relay coil terminal bosses, while excessive hold increases residual stress around the metal blades. Regrind is capped at 15 wt % for underhood relay housings; higher regrind fractions widen batch-to-batch terminal retention variation and can introduce surface contamination that reduces dielectric strength under humid conditions.

    Terminal products include ISO 280 mini relay housings, underhood fuse block connector bodies, and automotive relay covers and bases. Chemical exposure is limited to engine bay fluids such as unleaded fuel splash, washer fluid, and light oil mist. Continuous immersion in hot engine coolant, brake fluid, or polar solvents is not supported because unfilled PBT is susceptible to hydrolysis and stress cracking when simultaneous temperature above 85 °C and moisture above 85 % RH are maintained. Published multipoint retention data for this specific grade in relay geometries are limited; tool-specific retention force and thermal-cycle validation remain mandatory.

    Why are circuit breaker internal insulating parts moulded in an unfilled PBT-FR rather than a glass-reinforced grade?

    Circuit breaker internal insulating parts carry current-interrupting heat pulses and must retain creepage distances over the product’s service life. Glass-reinforced PBT grades can introduce glass-rich surface layers that reduce comparative tracking index and create localised surface roughness where carbon deposits accumulate under partial discharge. An unfilled flame-retardant PBT such as VALOX™ PBT-FR 310SEO BK1066 provides a more uniform surface morphology and avoids glass-fibre orientation effects that distort thin separation walls between phase barriers. Compliance is evaluated against IEC 60898-1 for miniature circuit breakers and IEC 60947-2 for moulded-case circuit breakers, with tracking resistance tested per IEC 60112:2009 and flammability verified per UL 94 V-0 at 0.71 mm. The material is used for moulded covers, toggles, terminal separation walls, and internal insulating carriers, not for arc chute side plates or surfaces directly exposed to sustained high-energy arcing.

    Moulding conditions differ from thin-wall connector work because breaker parts often have wall thicknesses from 2.5 mm to 6.0 mm. Melt temperature is kept between 245 °C and 255 °C to avoid flame-retardant decomposition during the longer hold phase. Mould temperature is maintained at 60 °C to 70 °C; higher mould temperatures raise the risk of sink on thick bosses and extend cooling time without improving creepage performance. Packing pressure is held at 35 MPa to 45 MPa until gate freeze, which is confirmed by a flattening of part weight over consecutive shots. Regrind is capped at 20 wt % for non-critical covers; for thin separation walls below 1.2 mm adjacent to current-carrying screws, the regrind ratio is reduced to 10 wt % and every batch is checked for tracking resistance after moulding. Terminal products include miniature circuit breaker housings, residual current device bases, and terminal covers for distribution boards.

    Motor commutator brackets and brush card mouldings impose a combination of local copper temperature, carbon brush dust, and mechanical vibration on the polymer. The material is selected because the UL 94 V-0 at 0.71 mm covers the thin brush holder walls, while the unfilled PBT structure allows close-tolerance openings for brush shunts and spring guides without glass fibre raising the surface roughness that catches carbon dust. In universal motors, the commutator surface may reach transient temperatures near 150 °C, and the polymer adjacent to the brush box must be evaluated against the UL 746B electrical RTI from the grade’s UL Yellow Card. If the motor is designed for continuous duty at full stall current, the brush card thermal condition exceeds the material’s long-term thermal capability and requires either additional air flow, a metal heat shield, or a different polymer segment.

    Insert moulding is again the limiting process step. Copper brush holders and steel spring anchors are preheated to 110 °C to 130 °C; when inserts are not preheated, differential shrinkage produces microcracks at the metal-polymer edge and brush dust entry can cause tracking failure later in the product life. Mould temperature is set at 80 °C, melt temperature at 245 °C to 255 °C, and holding pressure at 40 MPa to 50 MPa until the sprue and gate freeze. Regrind is not permitted above 20 wt % because higher fractions lower melt viscosity and increase the risk of flash around the brush holder shut-offs. Terminal products include vacuum cleaner motor brush cards, small appliance universal motor commutator brackets, and power tool motor end caps. Continuous exposure to chlorinated solvents or strong alkaline cleaning agents is not recommended because these chemicals attack PBT at the moulded surface and reduce dielectric strength.

    When ECU connector shells shift from PBT-GF30 to unfilled PBT-FR for low-warpage requirements

    Within electronic control unit connector shells, the replacement of glass-reinforced PBT by an unfilled flame-retardant grade is driven by anisotropic shrinkage in multi-cavity tools. A glass-reinforced PBT connector shell can show different longitudinal and transverse shrinkage, producing pin-to-pin misalignment in a multi-row connector when the cavity layout includes long, narrow returns. VALOX™ PBT-FR 310SEO BK1066 has a higher absolute mould shrinkage than PBT-GF30, but the absence of glass fibre reduces orientation-induced differential shrinkage across the part. The trade-off is a lower flexural modulus and lower pin retention force, so the connector design must compensate with thicker boss walls, shorter unsupported spans, and more robust latch geometry. Dimensional acceptance is normally defined by pin position tolerances of ±0.08 mm to ±0.15 mm across a 60 mm connector length, measured on a coordinate measuring machine after 48 h of post-moulding stabilisation.

    Processing conditions are selected to minimise differential shrinkage. Melt temperature is held at 245 °C to 255 °C, and mould temperature is held at 80 °C with separate cooling circuits for the cavity and the moving half. The injection speed is reduced to 80 mm/s to 120 mm/s for the first fill stage, followed by a lower-speed pack stage; this sequence reduces shear-induced orientation near the gate, which is the primary source of residual stress in unfilled PBT connector shells. Gate size is set to 0.8 mm to 1.2 mm diameter, and the gate is positioned at the thickest wall section rather than at a snap-fit root. Regrind is capped at 10 wt % because pin retention is sensitive to small reductions in molecular weight after repeated melt histories. Terminal products include ECU header connectors, body control module shells, and sensor connector bodies used in engine bay and cabin electronics.

    Terminal blocks for building electrical distribution require a combination of flammability classification, tracking resistance, and long uninterrupted moulding runs. The material is used for DIN rail mounted terminal blocks, distribution block insulators, and neutral bus supports. The wall thickness in this sector is commonly 3.0 mm to 10.0 mm, which is far above the 0.71 mm UL 94 V-0 plaque thickness; the thicker section changes cooling rate and flame-retardant morphology, so end-product flammability is verified at the largest cross-section. Tracking resistance is evaluated per IEC 60112:2009 after moulding, and glow-wire testing per IEC 60695-2-12:2014 is performed when the terminal block is installed in an enclosure covered by IEC 61439-1 or IEC 60947-7-1.

    Processing for thick section terminal blocks uses a lower melt temperature of 245 °C to 250 °C and a mould temperature of 60 °C to 70 °C. The lower mould temperature prevents excessive cosmetic sinking on the flat insulating base, but it also reduces crystallinity near the wall centre, so holding pressure is maintained at 35 MPa to 45 MPa for 8 s to 15 s depending on wall stock. Back pressure is set at 0.3 MPa to 0.5 MPa to maintain melt homogeneity without adding excessive shear heat. Regrind is allowed at 20 wt % for terminal blocks with no live hinge or snap-fit feature; screw-mounting bosses and metal insert areas use a lower regrind fraction of 10 wt % to maintain compressive strength. The material is not positioned for outdoor distribution blocks with prolonged UV exposure and constant water contact; interior electrical distribution panels remain the primary terminal product environment.

    Power tool trigger housings and finger guards subjected to mechanical drop and fault load

    Power tool trigger housings combine a flame-retardancy requirement with a drop-impact condition that rejects brittle failure. The material is evaluated for trigger bodies, switch insulators, and finger guards where the electrical load and motor current require a UL 94 V-0 classification at thin wall, but the moulded part must also survive repeated drop tests from 1.0 m onto concrete as specified in tool manufacturer reliability protocols. Unfilled PBT-FR is inherently less impact-resistant than impact-modified PBT or polycarbonate blends, so the part design includes generous corner radii, rib root fillets, and a minimum wall of 1.5 mm at the trigger pivot bosses. If the tool is specified for 2.0 m drop on concrete, this grade is generally not appropriate unless the housing itself is overmoulded with an impact-modified shell or the trigger assembly is isolated from impact load paths; published data for this specific configuration are limited.

    The processing window prioritises impact retention over maximum crystallinity. Melt temperature is held at 245 °C to 250 °C, and mould temperature is maintained at 60 °C to 70 °C. The lower mould temperature avoids excessive crystalline shrinkage that can produce internal voids around the trigger pivot steel pin. Holding pressure is set at 35 MPa to 45 MPa, and gate freeze is verified by part weight stabilisation. Regrind is capped at 15 wt %; impact-sensitive trigger bodies that pass drop testing at virgin 100 % may still fail when regrind exceeds this level because the repeated melt history reduces molecular weight and notch resistance. No external impact modifier or nucleant is dry-blended because the resulting change in shrinkage and flame-retardant distribution invalidates the established UL 94 classification without a full re-certification programme.

    Free Quote

    Competitive SABIC VALOX™ PBT-FR 310SEO BK1066 prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    SABIC VALOX™ PBT-FR 310SEO BK1066 is an unfilled, flame-retardant polybutylene terephthalate injection-moulding grade supplied as black pellets. The BK1066 suffix designates a black colour package, which distinguishes the product from natural or custom-coloured formulations of the same base resin. The polymer is characterised by a density of 1.41 g/cm³ when tested to ISO 1183-1. The flame-retardant classification is UL 94 V-0 at the minimum thickness recorded on the current SABIC yellow card. The grade is converted into thin-wall electrical connectors, relay sockets, terminal blocks, switch bodies, motor end caps, and appliance electrical housings where melt flow, solvent resistance, and electrical insulation are required.

    The unfilled structure provides lower melt viscosity than glass-reinforced VALOX flame-retardant grades and produces a resin-rich surface that is less abrasive to tool steel. The trade-off is lower flexural modulus and higher notch sensitivity. Tensile stress at yield for the unfilled grade is reported near 55 MPa per ISO 527-2/1A, and flexural modulus is reported near 2500 MPa per ISO 178. The material is not an impact-modified PBT; snap-fit designs should be evaluated at the lowest service temperature using ISO 179-1/1eA or ISO 180/A, because notched impact response is lower than that of toughened PBT grades.

    Melt-Temperature Constraints during High-Shear Conversion

    Flame-retardant PBT formulations are processed within a narrow barrel-temperature band. For this grade, melt temperature should be maintained between 250 °C and 270 °C. The lower boundary is set by melt viscosity and the ability to fill long flow paths without excessive injection pressure. The upper boundary is set by degradation of the flame-retardant package. Above 270 °C, thermal decomposition products can appear as splay, mould deposit, yellowing, and loss of UL 94 performance. The practical operating window in thin-wall tooling is therefore less than 20 °C; production trials on multi-cavity connector tools with wall sections below 0.8 mm commonly begin at a melt temperature of 260 °C and then adjust fill speed rather than increasing barrel set points.

    Drying before moulding is mandatory. The polyester backbone hydrolyses at melt temperature when residual moisture is present, causing molecular weight loss, reduced mechanical properties, and surface defects. Pellets are dried in a desiccant hopper dryer at 120 °C for 3–4 h. The drying-air dew point should not exceed -30 °C. Residual moisture must remain below 0.02 % by weight when measured to ISO 15512. If ambient relative humidity exceeds 60 %, dried pellets should be transported in closed dry-air lines and held in hopper environments protected from moisture regain. A hopper dryer with insufficient air flow or an exhausted desiccant bed produces intermittent moisture-related defects that are often mistaken for flame-retardant degradation.

    Residence time is a critical threshold variable. Total barrel residence time should not exceed 8 min at melt temperatures up to 260 °C. At melt temperatures above 260 °C, residence time should be reduced to 5 min or less. During cycle interruptions longer than 10 min, the barrel should be cooled or purged. Screw design should use a general-purpose screw with L/D 18:1–24:1, compression ratio 2.5:1–3.5:1, and no high-compression barrier mixing elements. Back pressure of 0.3–0.7 MPa is sufficient for consistent dosing. Excessive back pressure raises melt temperature and increases residence time in the compression zone.

    Mould temperature should be controlled between 60 °C and 100 °C. At mould temperatures below 60 °C, crystallinity drops, weld lines become brittle, and mould shrinkage becomes less uniform. At mould temperatures above 100 °C, cooling time increases and the flame-retardant system may generate mould deposits in vented areas. Hot-runner manifolds should be externally heated with independent zones and no dead spots; internal hot-runner temperatures above 270 °C degrade the material even when the machine barrel is at 260 °C. On injection moulding machines with screw diameters between 25 mm and 40 mm used for connector production, the melt cushion is kept between 3 mm and 6 mm to reduce residence time. Multi-cavity tools with hot-tip gates may generate shear heating above 270 °C at the gate even when the barrel set point is 260 °C; short-fill defects in these systems should first be addressed by increasing injection speed or gate diameter rather than raising melt temperature.

    Comparative placement of this grade within the VALOX PBT portfolio is necessary because substitution errors between unfilled and glass-reinforced flame-retardant grades produce dimensional and mechanical failures. Table 1 compares representative published values for PBT-FR 310SEO BK1066, glass-reinforced PBT-FR 420SEO, and non-flame-retardant unfilled PBT 310. The values are representative, not specification limits, and may shift with colourant loading, test specimen geometry, and moulding conditions.

    PropertyTest MethodPBT-FR 310SEO BK1066PBT-FR 420SEOPBT 310
    DensityISO 1183-11.41 g/cm³1.52 g/cm³1.31 g/cm³
    Tensile stress at yieldISO 527-2/1A55 MPa120 MPa55 MPa
    Flexural modulusISO 1782500 MPa9000 MPa2400 MPa
    Heat deflection temperature, 1.80 MPaISO 75-2/Af65 °C195 °C55 °C
    Flammability classificationUL 94V-0 at yellow-card thicknessV-0 at yellow-card thicknessHB

    The unfilled 310SEO BK1066 exhibits lower stiffness and lower heat deflection temperature than 420SEO, but it offers better melt flow and lower tool wear. The difference in HDT/A is significant in applications exposed to elevated ambient temperatures; a connector body moulded from 310SEO BK1066 may soften earlier than a 420SEO version under mechanical load. The glass-reinforced grade should be selected when the part must maintain clamping force or screw retention at temperatures above 80 °C. Conversely, 420SEO introduces anisotropic shrinkage and higher density, which can complicate thin-wall dimensional control and increase part mass. The unfilled grade also produces lighter parts and is less abrasive to reciprocating screw and barrel coatings.

    Compared with non-flame-retardant PBT 310, the flame-retardant version carries a higher density and may exhibit lower impact retention after thermal ageing. Flame-retardant additives can reduce melt stability and lower the practical upper melt-temperature limit. The replacement of non-flame-retardant PBT by 310SEO BK1066 should therefore be accompanied by a review of part wall thickness, gating, and hot-runner temperatures, because the flame-retardant package narrows the thermal processing window.

    What Are the Electrical and Flammability Listing Boundaries?

    Electrical performance is application-specific. The grade is suitable for insulation components where creepage and clearance dimensions are determined according to IEC 60664-1. Comparative tracking index should be evaluated on the black-pigmented formulation according to IEC 60112; black pigmentation can alter tracking resistance relative to natural flame-retardant PBT, so values from natural grades should not be transferred. Dielectric strength is measured according to IEC 60243-1, and volume resistivity according to IEC 62631-3-1. The current SABIC technical datasheet should be consulted for numerical values, because test specimen thickness and conditioning influence the results.

    Flammability classification is governed by the current UL yellow card, which lists the minimum thickness for V-0 performance. Extinction time and afterglow behaviour are thickness-dependent and are also influenced by part geometry, melt residence time, and colourant dispersion. The use of regrind in UL-listed applications is subject to UL follow-up service conditions and should be controlled to avoid shifting the flame-retardant concentration. For unattended appliance applications under IEC 60335-1, glow-wire testing should be performed on the finished part because wall thickness, colour, and melt flow affect the glow-wire result. The flame-retardant system is not declared halogen-free; applications requiring halogen-free formulations should be checked against the current SABIC regulatory datasheet.

    Thermal ageing limits are specified through the UL 746B relative thermal index values shown on the yellow card. The unfilled structure and flame-retardant additive package generate a lower continuous-use rating than glass-reinforced grades in some thicknesses. Long-term exposure to hot water above 80 °C should be avoided because PBT is susceptible to hydrolytic degradation and loss of mechanical strength. Exposure to strong alkaline solutions, amines, and certain metal-salt heat stabilisers at elevated temperature can accelerate degradation of the polyester chain.

    Chemical compatibility of 310SEO BK1066 in electrical housings should be verified on finished parts rather than on generic unfilled PBT data. The grade resists common appliance and automotive fluids at room temperature, but flame-retardant additives and black pigments can slightly alter chemical resistance compared with natural unfilled PBT. The product is not intended for prolonged outdoor ultraviolet exposure without a UV-stabilised coating or co-moulded protective layer; black pigmentation delays surface chalking but does not prevent eventual embrittlement.

    Mould shrinkage and post-mould annealing behaviour require part-specific measurement. Unfilled PBT of this type typically exhibits mould shrinkage in the range of 1.2 % to 1.8 % according to ISO 294-4, depending on flow direction, wall thickness, and mould temperature. Post-mould crystallisation can continue for several hours after ejection; dimensional inspection should therefore be delayed or a controlled annealing step should be used for critical dimensions.

    For applications involving laser transmission welding or infrared joining, the black pigmentation of BK1066 may absorb infrared energy and reduce transmission. The current SABIC application-development datasheet should be consulted before specifying this colour code for laser-welded assemblies. Hot-plate welding and ultrasonic welding are used as alternatives. In terminal-block applications, the material is selected only after dielectric strength, comparative tracking index, and glow-wire results meet the end-product standard. In relay sockets, spring retention and weld-line strength are evaluated using tensile specimens cut from gate and weld regions according to ISO 527. In motor end caps, dimensional stability after thermal cycling is measured under IEC 60068-2-14; the unfilled nature of 310SEO BK1066 reduces differential shrinkage between thick and thin sections compared with glass-reinforced PBT.