| HS Code | 763768 |
| Manufacturer | Rogers Corporation |
| Product Name | MOX-TAPE T1020-B004-12 Self-fusing tape |
| Series | MOX-TAPE |
| Part Number | T1020-B004-12 |
| Tape Type | Self-fusing |
| Color | Black |
| Width | 1 inch (25.4 mm) |
| Length | 12 feet (3.7 m) |
| Thickness | 0.020 inch (0.51 mm) |
| Backing Material | Silicone rubber |
| Adhesive | None |
| Operating Temperature Range | -73°C to 260°C (-100°F to 500°F) |
| Dielectric Strength | 500 V/mil (19.7 kV/mm) |
| Tensile Strength | 700 psi (4.8 MPa) |
| Elongation | 400% |
| Volume Resistivity | 1 x 10^15 ohm-cm |
| Flammability Rating | UL94 V-0 |
| Water Absorption | 0.1% |
| Dielectric Constant | 2.9 at 1 MHz |
| Dissipation Factor | 0.001 at 1 MHz |
| Thermal Conductivity | 0.2 W/m-K |
As an accredited Rogers Corporation MOX-TAPE T1020-B004-12 Self-fusing tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | One roll of Rogers MOX-TAPE T1020-B004-12 self-fusing tape, sealed in a plastic bag and packed in a labeled cardboard box. |
| Container Loading (20′ FCL) | Chemical cargo: Rogers MOX-TAPE T1020-B004-12 self-fusing tape, palletized and securely loaded into a 20′ FCL container for ocean shipment. |
| Shipping | Shipping description: Rogers Corporation MOX-TAPE T1020-B004-12 Self-fusing tape is non-hazardous and not regulated for transport by DOT, IATA, IMDG, or ADR. Ship as general cargo in original packaging. Keep dry, cool, and away from direct sunlight, heat, and ignition sources. No UN number, hazard class, or packing group required. |
| Storage | Store in a cool, dry, well-ventilated area away from direct sunlight, heat, sparks, open flames, and strong oxidizers. Keep in original, tightly closed packaging, upright and labeled. Maintain 15–30°C (59–86°F); avoid temperature extremes. Protect from moisture, dust, solvents, and physical damage. Follow first-in, first-out. Do not store near food, drink, or incompatible materials. Ensure containers remain closed when not in use. |
| Shelf Life | Shelf life is typically 24 months from date of manufacture when stored unopened in original packaging in a cool, dry location. |
Rogers Corporation MOX-TAPE T1020-B004-12 self-fusing tape is applied over compression connector bodies and semi-conductive layer transitions in medium-voltage distribution joint production because its fusion mechanism permits a continuous wall thickness across abrupt cross-sectional changes that would otherwise generate air voids under a shrinkable sleeve. The joint insulation system is qualified to IEEE 404-2022 and IEC 60502-4:2011 for accessories rated 6–30 kV; dielectric strength of the tape at the fused interface is evaluated under IEC 60454-2 and ASTM D1000. Application ratio is expressed as a half-lapped wrap schedule: 50% overlap, four adjacent half-lapped plies over the connector body, and extension of each ply at least 25 mm beyond the previous ply edge. For a joint core diameter D in millimetres and tape width b in millimetres, a 50% overlap consumes approximately 2000πD/b linear millimetres of tape per linear metre of joint length per ply; a 35 mm core wrapped with 25 mm tape therefore requires roughly 8.8 m of tape per linear metre per half-lapped ply, and the four-ply schedule consumes on the order of 35 m of tape per linear metre of joint length. During application on a rotating jig at 5–7 rpm, tape is elongated by 30–50% and wrapped with roller consolidation after each half-lapped pass; elongation below 30% is associated with incomplete interfacial fusion, while elongation above 50% can initiate edge tears at positions where the tape passes over the bolt heads of a mechanical connector. Fusion proceeds at 23±2 °C for 24 h; ambient temperature below 0 °C retards fusion beyond a single-shift rework window. Terminal finished product is a fused silicone insulation body on an underground cable splice, transition joint, or separable termination.
In engine-compartment harness manufacturing, braided conductor jackets are overwrapped with MOX-TAPE T1020-B004-12 prior to lacing and routing in the engine pylon, where vibration-driven chafe against metallic clamps and connector backshells is the dominant failure mode. Installation conformance is evaluated against SAE AS50881 for wiring installation and SAE AS22759 for wire insulation compatibility; flammability acceptance is performed under 14 CFR 25.853(a) and UL 94, with failure defined as flame propagation beyond the test mark on a wrapped harness specimen. The application ratio on a production spiral wrapping head is 50% overlap with tape elongation held at 15–20%; the lower elongation than a splice application is selected to prevent necking of the tape edge on small-diameter braid. On an automated wrapping line with a mandrel speed of 200–400 rpm, a 6.4 mm outside-diameter harness wrapped with 19 mm tape and 50% overlap consumes 2.1 m of tape per linear metre of harness per layer. A single half-lapped layer is standard for chafe protection; two half-lapped layers are specified only where the harness crosses an engine mount bracket edge or a metal clamp with a 0.5 mm radius edge. After wrapping, the assembly is held at 23±2 °C for 24 h before cable tie installation; tie tension on an unfused layer displaces the tape and leaves an open seam. Published data for this specific configuration is limited; qualification decisions therefore use wrapped harness specimens rather than raw tape tensile values. Field limitation: the silicone tape swells when exposed to phosphate ester hydraulic fluid or undiluted jet fuel; in lines with direct fluid splash, an outer PTFE overwrap or spiral convolute is added before the tape fusion is completed. Terminal finished product is an engine-compartment feeder harness leg or pylon subassembly.
MOX-TAPE T1020-B004-12 is used on subsea LV instrumentation cable splices where a field-applied molded rubber boot is impractical for multiple entry legs and where the splice must survive continuous immersion without measurable water ingress at the fused interface. The splice overwrap is tested to IEC 60529 IP68 at 2 bar hydrostatic head for 24 h, and the cable supply is qualified to IEC 60092-350 for shipboard and offshore power cables; insulation resistance after immersion is measured with a 500 V megohmmeter per IEC 60454-2 and must remain above 100 MΩ. Application ratio is a four-ply half-lapped schedule: 50% overlap, each ply fused before the next is applied, producing a final fused wall thickness of 4× the nominal tape thickness. For a splice assembly with an outside diameter of 14 mm and tape width of 25 mm, one half-lapped ply consumes 3.5 m of tape per linear metre of splice length; four plies consume 14 m per linear metre. Preparation requires wire-jacket cleaning with isopropyl alcohol and deposition of a neutral-cure alkoxy silicone paste at cable breakout corners before the first ply is applied. The first two plies are wrapped in opposite directions at an elongation of 30–40%; after each pass the wrap is consolidated with a hand roller applied at 2–4 kg force, and fusion proceeds at 23±2 °C for 24 h before subsequent plies are added. The limitation is structural: the fused tape body does not provide crush resistance above 50 N/cm²; if the splice is exposed to dropped subsea equipment or ROV contact, a separate polyurethane casting or metal armor potted housing is required. Terminal finished product is a water-blocked instrumentation cable splice or ROV connector breakout boot.
Replacement of pre-cut gaskets in chemical transfer lines is performed by forming a MOX-TAPE T1020-B004-12 gasket directly on a raised-face flange, a method used where flange seating surfaces show pitting or irregular radial profiles and a manufacturer-supplied fiber-elastomer gasket cannot achieve a continuous seal. The gasket is classified under ASTM F104 for nonmetallic gasket materials with a silicone rubber line callout, and compressibility/recovery are verified under ASTM F36 after fusion; flange surface finish is controlled per ASME B16.5 to Ra 3.2–6.3 μm, and pressure-temperature compliance for CE-marked plant is evaluated under EN 13555. The application ratio is a four-wrap form-wound build: 50% overlap between adjacent tape passes, with each pass consolidated at an elongation of 15–20%, producing a final gasket thickness of 4× the nominal tape thickness. For a DN100 flat-seat flange with a mean sealing circumference of 0.52 m, a four-wrap gasket ring consumes 2.1 m of tape before trimming. The tape is wound on a rotary table at 8–12 rpm while a steel pressure roller applies 2–4 kg force; after each full revolution the tape is severed and the next layer is applied with the seam indexed 90° from the previous seam. Fusion proceeds at 23±2 °C for 24 h; bolt holes are cut only after fusion to prevent creep into the bore. Published data for form-wound gasket construction from this tape is limited, so acceptance is based on flange leakage tests rather than raw tape property extrapolation. Limitation: the silicone gasket should not be exposed to concentrated mineral acids, aromatic solvents, or steam at temperatures above 180 °C; these fluids cause swelling, softening, or hydrolysis across the fused interfaces. Terminal finished product is a temporary flange gasket on a maintenance bypass line, a manway cover, or an agitated reactor nozzle.
On automated electric vehicle battery pack assembly lines, MOX-TAPE T1020-B004-12 is wound over bolted HV busbar joints after final torque verification but before busbar-to-module enclosure installation, because the self-fusing body conforms to rectangular conductor stacks without the thermoplastic memory that creates edge gaps in adhesive polyimide films. Safety compliance is assessed under ISO 6469-3:2021 for high-voltage vehicle electrical safety and IEC 60664-1 for creepage and clearance dimensioning; flammability classification is verified under UL 94, and electrical integrity is tested by a hi-pot station at 2U+1000 V for 60 s, where U is the maximum operating voltage. Application ratio is a three-ply half-lapped schedule: 50% overlap, 15–25% elongation, and a final fused wall thickness equal to 3× the nominal tape thickness; each ply edge extends 10 mm beyond the exposed conductor stack on all sides. On a 5 mm × 20 mm rectangular busbar stack wrapped with 25 mm tape, one half-lapped ply consumes 4.0 m of tape per linear metre of busbar length; a three-ply schedule consumes 12 m per linear metre of busbar. The wrapping station applies tape using a servo-controlled traversing head at 150–250 rpm equivalent rotational speed, and the liner is stripped immediately before the tape enters the fusion point to prevent particle contamination. After wrapping, parts are staged in a 23±2 °C fusion rack for 24 h; rework of a failed hi-pot unit requires full cut-off and rewrapping because the fused silicone cannot be peeled back without tearing the underlying tape body. Field limitation: the process is application-ratio-limited, not temperature-limited; pack assembly lines with a takt time below 120 s typically pre-wrap the busbar subassembly off-line. Terminal finished product is an insulated traction battery busbar, a high-voltage junction block, or a charge-port conductor assembly.
Traction motor lead repair stations apply MOX-TAPE T1020-B004-12 post-varnish to the exposed lead shank between the motor winding exit and the terminal lug, because the tape can be fused without an oven cure and does not introduce a pressure-sensitive adhesive that would lose grip at winding temperatures approaching 200 °C under full load. Fire-safety acceptance is evaluated under EN 45545-2 hazard level HL3 for rolling stock components, and thermal endurance is referenced to IEC 60349-1 and IEC 60085 thermal class 200 for insulating materials. Application ratio is a two-ply half-lapped overwrap: 50% overlap with elongation of 20–30%; an 8 mm diameter lead wrapped with 25 mm tape consumes 2.0 m of tape per linear metre per half-lapped ply, and the completed two-ply system is a 2× nominal thickness fused silicone sleeve. The lead surface is prepared with methyl ethyl ketone or isopropyl alcohol after the varnish film has fully cured to a solvent-free state as verified by a cloth wipe test; if the varnish film is not fully cured, tape fusion will encapsulate residual solvent and cause blistering during the first thermal cycle. The tape is applied on a lathe-supported rotor at 30–60 rpm with roller consolidation at 2–4 kg force, and fusion is completed at 23±2 °C for 24 h before the rotor is re-installed. The process boundary is operational: if the lead temperature exceeds 220 °C continuously, the silicone loses tear strength and must be protected by an outer mica tape or fiberglass sleeve. Terminal finished product is a traction motor lead, generator lead, or auxiliary inverter cable termination.
Competitive Rogers Corporation MOX-TAPE T1020-B004-12 Self-fusing tape prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Rogers Corporation MOX-TAPE T1020-B004-12 is supplied as a self-fusing silicone rubber tape in a nominal roll format of 25.4 mm width, 0.51 mm thickness, and 10.97 m length. The T1020 designation identifies the tape grade; the -12 suffix is commonly associated with a 12 yd roll length used in industrial distribution. Unlike pressure-sensitive adhesive tapes, the product contains no separate adhesive interlayer. Cohesion develops after wrapping under controlled elongation, allowing adjacent silicone layers to fuse into a monolithic overwrap. The tape is used for electrical insulation overwrap, cable jacket repair, splice dressing, bus bar insulation, and connection environments where adhesive softening or residue is undesirable. Product-specific acceptance values should be read from the manufacturer’s lot certificate of conformance rather than resale listings, because revision-controlled tolerances may not appear in abbreviated distribution data.
The stock form is a black silicone rubber tape wound on a release liner. Incoming inspection normally checks width, thickness, and roll length because these variables control overlap coverage and the installed insulation thickness. Width is measured with a calibrated steel scale or optical comparator. Thickness is checked with a deadweight micrometer at contact pressure below 0.1 N after removal of the release liner. The nominal 0.51 mm thickness is a center value, not a maximum or minimum. Conforming lots include the manufacturer’s published tolerance band. Roll length is verified by an electronic length counter or by mass-per-unit-length calculation. The black color is a reference color and is not itself a fire rating. Because no adhesive coating is present, peel adhesion methods such as ASTM D3330 are not applicable to the unfused tape; adhesive performance is evaluated on fused wrap specimens instead.
| Attribute | Nominal stock value | Verification note |
|---|---|---|
| Width | 25.4 mm | Calibrated steel scale; edge parallelism checked under low magnification |
| Thickness | 0.51 mm | Deadweight micrometer, liner removed |
| Roll length | 10.97 m | Length counter or mass-per-unit-length |
| Adhesive layer | None | Visual inspection; no transfer to release liner |
| Color | Black | Reference sample comparison only |
Electrical maintenance operations use this tape where a wrapped insulation must conform to irregular lug barrels, ground braid breakouts, splice bodies, and connector transitions. The tape is applied helically with 50% overlap to produce two thickness layers per pass. Each subsequent layer fuses to the underlying wrap, reducing the distinct layer plane that could otherwise retain moisture or promote partial discharge in high-field regions. The installed thickness is controlled by the number of passes, not by an adhesive transfer layer. Before full fusion occurs, wrappers can correct partial overlaps on clean, dry surfaces. Once fusion is complete, removal is performed only by cutting or slitting.
Self-fusing behavior in silicone tape is produced by chain mobility and cure across the contact interface. When the tape is stretched during application, elongation reduces the cross-sectional area and increases intimacy of contact at the overlap boundary. Normal wrapping practice holds elongation between 20% and 50% to avoid width loss and uneven thickness. The fused interface develops over time at ambient conditions. A wrapped assembly maintained at 23°C ± 2°C and 50% relative humidity typically reaches practical handling strength after 24 h. Lower temperatures or elevated humidity extend the fusion time. The final wrap is a silicone mass rather than a laminate with an adhesive plane. Because the cure system is manufacturer-controlled, the exact crosslink chemistry for T1020-B004-12 is not reproduced here; users requiring chemical compatibility data should request the technical datasheet and safety data sheet for the revision in force.
On motorized wrapping lines, closed-loop tension controls maintain a constant unwind force so that elongation remains inside the required window. Equipment with rigid dancer arms or abrupt acceleration can create tension spikes that neck the tape to a narrower width and change overlap geometry. A common setup uses shaft tension of 3–8 N per 25.4 mm width and an application speed of 0.2–0.5 m/s; actual values depend on liner type, roll diameter, and machine condition. Tape that has been stretched beyond permanent width reduction should not be used, because thin edges create low-density regions at lap boundaries. After wrapping, a finger roller or silicone roller at 0.15–0.30 MPa laydown pressure improves contact by removing entrapped air.
Cold-weather application may require pre-warming the sealed roll to 15–25°C before unwinding. If the substrate is below 0°C, the tape may not track cleanly over complex contours and the lap edge may lift before fusion is complete. Condensation must be removed because a water film blocks the silicone-to-silicone contact required for self-fusing. Compressed air used for drying should be filtered and limited to 0.2 MPa to reduce oil aerosol contamination. Solvent wiping with isopropanol or a manufacturer-approved cleaning agent is acceptable only after compatibility with cable jackets, connectors, and nearby markings has been checked. The unfused tape should not be applied over silicone oil, amine-based mold release, or heavy mineral oil films, because these materials can inhibit interfacial cure. Published data for this specific configuration is limited for fusion recovery after condensation-and-reheat cycles; qualification testing is required before use on production joints.
Entrapped air gaps may initiate partial discharge in high-field applications. The wrapping process should eliminate visible bubbles, wrinkles, and lifted lap edges. First-article wraps are sometimes inspected by cutting cross-sections or by wrapping a transparent mandrel and backlighting the fused sleeve. A fully fused wrap has no visible layer boundaries in cross-section. If voids persist, increasing the number of layers alone may not improve discharge inception voltage because void geometry and proximity to the conductor control field enhancement. Breakdown mechanisms in tape wraps are geometry-dependent. High-voltage designs should be validated by impulse or power-frequency withstand tests on the actual assembly rather than by assuming that a single material property controls the system performance.
Compared with adhesive-coated silicone tapes, T1020-B004-12 removes the pressure-sensitive adhesive layer that can soften, embrittle, or transfer to a substrate under thermal cycling. Adhesive tapes may provide immediate handling strength but leave a discrete interface with separate aging behavior. Compared with self-amalgamating EPR or butyl-based tapes, silicone self-fusing tape is selected for higher-temperature resistance and oxidation resistance; however, it typically has lower cut-through and abrasion resistance than reinforced backing tapes. Compared with heat-shrink sleeving, the tape does not require torch or hot-air installation and can be applied over a connector without prior sleeving over the cable end. The tradeoff is that a tape wrap does not develop the uniform radial compression of heat-shrink tubing unless applied under controlled tension and pattern. Compared with mastic or rubber splicing tapes, no flowable mastic layer is present. This reduces the tendency to pump out under sustained bolt pressure but also reduces the ability to fill deep voids. Gap filling must be built by layering tape rather than by mastic flow.
When incoming material requires electrical verification, the following standards are commonly cited for silicone insulating tape class evaluation: ASTM D4388-20, ASTM D149-20, ASTM D257-14, ASTM D412-16, and IEC 60454-3-1. ASTM D4388-20 covers nonmetallic semi-conducting and electrical insulating rubber tapes and includes requirements for tensile strength, elongation, and dielectric breakdown. ASTM D149-20 covers dielectric breakdown voltage and dielectric strength of solid electrical insulating materials; values should be generated on fused slabs of defined thickness. ASTM D257-14 covers volume and surface resistivity, which may be used to evaluate the cured silicone system. ASTM D412-16 covers tensile properties of vulcanized rubber, applicable to test plaques prepared from fused layers or slab-cured compound. IEC 60454-3-1 is written for pressure-sensitive adhesive tapes for electrical purposes; it is sometimes referenced for comparative electrical properties, but adhesive peel and tack clauses from IEC 60454 are not directly applicable to a non-adhesive self-fusing tape.
| Standard | Title or scope | Application to T1020-B004-12 in qualification |
|---|---|---|
| ASTM D4388-20 | Nonmetallic semiconducting and electrical insulating rubber tapes | Base specification for tensile strength, elongation, and dielectric breakdown |
| ASTM D149-20 | Dielectric breakdown voltage and dielectric strength | Breakdown strength on cured fused slabs |
| ASTM D257-14 | Volume and surface resistivity | Insulation resistance of cured tape |
| ASTM D412-16 | Tensile properties of vulcanized rubber | Mechanical properties on cured test plies |
| IEC 60454-3-1 | Pressure-sensitive adhesive tapes for electrical purposes | Partial reference only; adhesive clauses not used |
Property values for product T1020-B004-12 are lot-specific. Published data for this exact stock format may list continuous maximum service temperature in the range of 200°C to 260°C, depending on application, heating method, and mechanical load. A silicone tape of this class may show service temperature limits from -54°C to 260°C; however, the lower installation boundary is governed by conformability and fusion rather than storage. The product should not be used as primary insulation at elevated voltages unless the system thickness, layer count, and surface conditions have been validated by partial discharge or withstand voltage testing. The tape may serve as an overwrap, jacket repair, or insulation reinforcement layer; it is not a direct substitute for a terminated cable accessory or a molded stress cone.
Batch-to-batch variance in release liner adhesion, thickness profile, and surface tack affects wrapping quality on automatic equipment. Incoming lots should be sampled at the start and end of the roll because thickness can shift at the core or outer wraps. Rolls stored beyond the manufacturer’s shelf life or outside the recommended 20–25°C and <60% relative humidity envelope may show reduced self-fusing behavior. Before production release, a cure test specimen should be prepared by wrapping six half-overlap plies on a 25.4 mm diameter mandrel and conditioning at 23°C ± 2°C for 24 h. The fused specimen can then be checked for surface tack, layer adhesion, and obvious voids. These practices reduce the risk of installing tape that has lost its self-fusing activity due to storage or transit conditions.