Products

Rogers Corporation MOX-TAPE T1010-B004-12 Self-fusing tape

    • Product Name: Rogers Corporation MOX-TAPE T1010-B004-12 Self-fusing tape
    • Factroy Site: Yinchuan, Ningxia, China
    • Price Inquiry: sales8@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 471257
    Manufacturer Rogers Corporation
    Product Name MOX-TAPE T1010-B004-12 Self-fusing Tape
    Part Number T1010-B004-12
    Tape Type Self-fusing silicone rubber tape
    Adhesive None
    Material Silicone rubber
    Color Gray
    Thickness 0.010 in (0.25 mm)
    Width 0.5 in (12.7 mm)
    Length 12 ft (3.66 m)
    Dielectric Strength 400 V/mil (15.7 kV/mm)
    Tensile Strength 700 psi (4.8 MPa)
    Elongation At Break 500%
    Dielectric Constant 2.8 at 1 MHz
    Dissipation Factor 0.001 at 1 MHz
    Volume Resistivity 1 x 10^15 ohm-cm
    Operating Temperature Range -100°F to 500°F (-73°C to 260°C)
    Water Absorption <0.1%
    Thermal Conductivity 0.2 W/m-K
    Self Fusing Time 24 hours at room temperature

    As an accredited Rogers Corporation MOX-TAPE T1010-B004-12 Self-fusing tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Rogers Corporation MOX-TAPE T1010-B004-12 comes in a 12-roll carton, each roll individually wrapped and labeled.
    Container Loading (20′ FCL) 20′ FCL container loading: palletized Rogers MOX-TAPE T1010-B004-12 self-fusing tape; keep dry, ambient, secured; no special ventilation required.
    Shipping Rogers Corporation MOX-TAPE T1010-B004-12 is a self-fusing tape, not classified as dangerous goods for transport. Ship at ambient temperature in original sealed packaging, protected from moisture, sunlight, and damage. No special DOT/IATA/IMDG labeling required unless the SDS or carrier states otherwise.
    Storage Store Rogers Corporation MOX-TAPE T1010-B004-12 in its original, sealed packaging in a cool, dry, well-ventilated area. Keep away from direct sunlight, heat, sparks, flames, moisture, and incompatible chemicals. Maintain moderate room temperature, avoid extreme conditions, and protect from physical damage. Observe shelf-life, first-in/first-out rotation, and local regulations. Do not store near food or drinking water. Ensure containers remain labeled and closed.
    Shelf Life Typically 12 months from date of manufacture when stored in original packaging at 15–30°C, protected from sunlight, moisture, and contamination.
    Application of Rogers Corporation MOX-TAPE T1010-B004-12 Self-fusing tape

    Rogers Corporation MOX-TAPE T1010-B004-12 self-fusing tape is assessed in six downstream manufacturing segments. Product-specific compound formulation addition ratios are proprietary to Rogers Corporation and are not disclosed in public merchandising documents; when this tape is incorporated downstream, the controlled addition variable is recorded as overlay addition ratio, defined by percentage overlap, applied percent elongation, and tape thickness count per pass. Where published data for the exact part number is limited, the operational limits below are derived from the self-fusing silicone tape class and should be validated against the supplier certificate of analysis. Each application entry states the governing industry compliance standard, the applied addition ratio, the downstream manufacturing process, and the terminal finished component class.

    Thermal Stability and Outgassing Controls in Unpressurized Airframe Wire Harness Overwrap

    Airframe electrical harness fabrication for rotorcraft and fixed-wing platforms requires insulation materials that maintain elongation after exposure to phosphate ester hydraulic fluids and satisfy the flammability constraints of FAR 25.853(a). The tape is applied on a spiral wrapping head in harness mock-ups with a 50% overlap and 25–40% applied elongation, producing a residual compression layer that self-fuses within 8–24 h at 20–25°C. The overlay addition ratio for a single overwrap pass at 50% overlap is 2:1 tape thicknesses after the overlap is consumed. Compliance documentation for airframe installations includes ASTM E595-15 for total mass loss below 1.0% and collected volatile condensable material below 0.1%, plus RTCA DO-160G Section 26 for fire resistance on hidden or exposed harness surfaces. Downstream production uses heated rotating mandrels in a wire shop with 0.25–0.5 N/mm tape tension applied through a calibrated pneumatic brake; tension setpoints below the lower bound reduce interfacial contact and create tack voids, while tension above the upper bound can distort flat-conductor insulation and create latent necking zones. Sulfur-cured EPR substrates are cleaned to remove free sulfur bloom before wrapping because residual sulfur can interfere with interfacial fusion. Terminal finished components include harness branch-outs, strain-relief transitions, and breakouts in engine pylons and landing-gear runs.

    Inside factory-built and field-installed medium-voltage cable accessories, the dominant failure mode at the insulation/dielectric interface is partial discharge initiated by entrapped microvoids that remain after cold-shrink or heat-shrink body installation. The tape is used as a stress-grading underlay or void-fill layer beneath heat-shrink breakout boots and cold-shrink terminations. On a motorized cable preparation bench, the jointing technician applies the tape at 60–70% overlap when the cable insulation OD transitions from XLPE to semicon screen, providing a gradual geometry change. The overlay addition ratio at 66% overlap yields 3 tape thickness increments per pass and reduces the air inclusion probability compared with a single-layer butt wrap. Compliance is governed by IEC 60502-4 for medium-voltage accessories up to 30 kV, IEEE 404 for extruded and laminated dielectric shielded cable joints, and CIGRE TB 446 accessory interface electrical strength recommendations. The downstream process includes ambient-temperature self-fusion for a minimum of 24 h before factory hipot testing, with partial discharge testing performed at 1.73 U₀ according to IEC 60840 for 69 kV and above. The tape is not a replacement for the moulded joint body where the original equipment manufacturer specifies a heat-shrink outer jacket; it functions only as void-fill and stress-transition material. Terminal finished products are transition joints, trifurcating kits, and transformer or junction box terminations installed in underground distribution vaults.

    What Approvals Govern Retrofit Cable Splice Sealing in Tropical Marine Air?

    Retrofit sealing of deck-level lighting and navigation cable splices on offshore vessels and shore-based ports is driven by salt-mist survival and low-smoke, halogen-free emission requirements. The self-fusing tape is specified as the primary water block layer beneath a two-part polyurethane or self-leveling silicone overmold. Onboard electricians wrap the splice with 50% overlap and 30–50% elongation, achieving 3–4 tape thicknesses over the connector barrel. The addition ratio is recorded as tape thickness count per splice rather than mass addition rate, because the material is not compounded into the cable polymer. Compliance is anchored to IEC 60092-351 for electrical installations in ships and IACS UR E11 for essential services; low-flame-spread behaviour is evaluated according to IEC 60332-1-2 for a single cable, with smoke density and halogen acid gas content assessed by IEC 61034-2 and IEC 60754-2. The production process is manual wrapping under a temporary humidity-controlled enclosure when relative humidity exceeds 70%, followed by 24 h self-fusion before overmold application; premature overmold application below the fusion threshold traps moisture at the tape-to-metal interface. Terminal finished product types include water-blocked junction boxes, navigation light cable joints, and emergency stop circuit splices on open decks.

    Because automotive high-voltage harness manufacturers must satisfy bend radius durability and contact resistance requirements within sealed battery pack environments, the tape is inserted as a supplemental abrasion and arc-flash barrier over ultrasonically welded busbar joints and terminal lugs. The addition ratio in pack-level assembly is normally 50% overlap with 30% applied elongation, providing 2 layers per pass around flat busbar geometry; at lug-to-cable transitions the tape is doubled over the crimp shoulder to compensate for edge strain. Compliance is verified with ISO 6722-1:2011 for 60 V DC to 600 V DC road vehicle cables, ISO 6469-3:2021 for protection of persons against electric shock, and RoHS Directive 2011/65/EU with delegated amendments. The downstream process uses a semi-automatic taping station with controlled tension between 3 N and 6 N, followed by heat-shrink retention sleeves and silicone potting for IP6K9K-rated enclosures. Plasticizer migration from adjacent PVC sleeves can reduce the self-fusion bond, so the line buffer zone separates the tape from flexible PVC components by 10 mm minimum. Terminal products are lithium-ion battery module interconnect harnesses, PDU or power distribution unit cable sets, and motor inverter cable overbraid repair sleeves.

    When Chlorinated Process Environments Attack Unjacketed Instrument Cable

    In chlor-alkali, hydrochloric acid storage, and bleach production areas, instrument cables with polyethylene or PVC jackets develop microcracking at cable tray supports due to acid mist deposition and ultraviolet exposure. The tape is applied as a removable over-jacket barrier over the cable tray segment from the tray exit to the instrument gland, with 50% overlap and minimum 20% stretch to create a continuous inert silicone sleeve. The addition ratio is expressed as linear meter of tape per meter of cable; at 50% overlap the consumption factor is 2.0 m/m. Compliance references IEC 60079-14:2013 for electrical installations in hazardous areas, ASTM D471-16e1 for fluid resistance after immersion in 10% hydrochloric acid for 72 h at 23°C, and IEC 60754-2 for halogen acid gas generation below the threshold for plant permit submissions. The downstream process includes solvent wiping of the jacket with isopropyl alcohol, wrapping from bottom to top to create watershed laps, and 24 h ambient fusion before final inspection. Sharp cable tray burrs must be deburred or covered with a stainless steel guard because the tape is not a substitute for mechanical armor. Terminal finished product types are acid-resistant jacketed instrument cables, solenoid valve cable transitions, and chlorine detector cable splices.

    Rolling stock refresh programs for metro EMUs require insulation materials that pass EN 45545-2:2020 fire performance while maintaining flexibility under underframe vibration. The tape is used in a dual-layer system with a PTFE skid wrap over the inner self-fusing silicone layer on door operator cables, inter-car jumpers, and cab console harnesses. In underframe wiring repairs, maintenance depots apply the tape at 60% overlap and 25% elongation, creating 3 thickness increments per pass to the abrasion zone. The addition ratio is recorded as three-layer build-up over wear points rather than a compound loading percentage. Compliance is evaluated using EN 45545-2:2020 hazard level HL3 for listed components, NFPA 130:2020 for fixed guideway transit systems, and ASTM D1000-17 for tape breaking strength and elongation; halogen-free behaviour is confirmed by EN 60754-2. Downstream process conditions include surface cleaning with a dry-lubricant solvent, wrapping with a hand-held tensioning tool, and 24 h self-fusion before a final high-voltage dielectric withstand test at 1 kV DC on the repaired harness. The self-fusion interface is compromised by silicone oil or mould-release residues, so the surface is verified by a water-break-free inspection before wrapping. Terminal finished product types are remanufactured inter-car jumper cables, door motor harness sleeves, and axle counter cable repairs.

    Free Quote

    Competitive Rogers Corporation MOX-TAPE T1010-B004-12 Self-fusing tape prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    The Rogers Corporation MOX-TAPE T1010-B004-12 is a self-fusing silicone elastomer tape supplied in roll form without a pressure-sensitive adhesive or mastic interlayer. The complete designation separates the T1010 series from the roll-configuration suffix B004 and the linear-run identifier 12; exact width, thickness, and roll length must be confirmed against the current Rogers Corporation product bulletin because suffix conventions vary across the BISCO elastomer portfolio. The product is used as an overwrap insulation and mechanical protection layer for cable harnesses, high-voltage connector bodies, and repair splices where re-enterability, clean removal, and high-temperature oxidation resistance are required. Unlike adhesive-backed electrical tapes, the T1010-B004-12 develops a consolidated elastomeric layer through self-fusion when the tape is wrapped under controlled tension and pressed onto itself.

    Supplier-controlled material properties for the T1010 series are characterised by standard elastomer test methods. Tensile strength and ultimate elongation are measured under ASTM D412-16; durometer is measured under ASTM D2240-15(2021); specific gravity is determined under ASTM D792-20; dielectric breakdown voltage is evaluated under ASTM D149-20; and volume resistivity is measured under ASTM D257-14(2021). These data characterise the unfused tape and are not a direct expression of the fused overwrap performance. Incoming inspection of roll dimensions and liner release is normally conducted against the supplier’s current product bulletin and lot-specific certificate of analysis. The suffix B004-12 is a configuration code rather than a direct metric dimension, and converting the suffix into inch or millimetre values without the current bulletin can introduce specification error.

    Which material parameters control fusion and layer-to-layer consolidation?

    Fusion of the T1010-B004-12 is a contact-dependent process governed by surface cleanliness, application elongation, and time-temperature exposure after wrapping. The self-fusing mechanism does not require heat activation at typical room-temperature application, but cycle time to reach handling strength shortens when the wrapped assembly is held at elevated temperature. Manufacturing lines using semi-automated wrapping heads control elongation by setting dancer-arm tension and tape-path friction; hand application tends to produce greater variation in fused-layer thickness and must be controlled by operator training and in-process layer-count verification. If elongation is excessive, the applied tape width narrows and the effective dielectric cover per wrap decreases. If elongation is insufficient, interfacial voids remain and layer-to-layer fusion is incomplete.

    The tape surfaces must be protected from finger oils, glove-derived plasticizers, dust, and mold-release residues before wrapping. The release liner is removed immediately before application, and the first and final wraps are pressed with roller pressure to initiate consolidation. Full mechanical amalgamation may require a conditioning period at controlled ambient temperature; the manufacturer’s application guide for the T1010 series should be consulted for cycle times at different process temperatures. The product is not designed for direct adhesion to untreated polyethylene or fluoropolymer surfaces because fusion occurs only at the tape-to-tape interface.

    On wire-harness production lines, the tape is applied over connector backshells and breakout transitions where a preinstalled heat-shrink component cannot be placed without dismantling the terminal. The self-fusing overwrap provides a removable insulation boot with no adhesive bleed. Production audits identify several recurring failure modes: liner splitting caused by excessive unwind drag, irregular tape edges caused by misaligned payout, and incomplete fusion at the final tack because the tail was not pressed. These are tooling and tension-control defects rather than adhesive chemistry defects because the product contains no adhesive phase. On high-speed cable taping lines, batch-to-batch variation in roll width and liner separation force can alter tape payoff angle and cause chatter if the wrapping head has a fixed brake setting.

    Dielectric performance boundaries in contaminated service and partial discharge risk

    Electrical insulation performance is a system property of the fused overwrap rather than a single-material constant for the unfused roll. Dry dielectric breakdown is evaluated under ASTM D149-20, but service voltage capability must account for voids, cuts, moisture ingress, and layer count. A fused overwrap with incomplete consolidation can exhibit partial discharge in high-gradient alternating-current service. Qualification coupons should be wrapped at production tension and layer count, then conditioned under the end-use temperature and humidity cycle before dielectric testing. Published data for the specific T1010-B004-12 configuration in high-humidity partial discharge service may be limited; users should request fused-configuration voltage endurance data from the supplier rather than extrapolating from unfused tape properties.

    Silicone elastomer has high volume resistivity when clean and dry, as measured under ASTM D257-14(2021); surface resistivity after handling may decline if contamination is present. The liner should remain in place until immediately before wrapping. If the assembly will contact salt spray, de-icing fluids, or hydraulic oils, environmental sealing qualification is required. The fused tape forms a barrier over the connector, but the cut edge and tail remain possible moisture-ingress paths. A sealant or sealant tape may be required at transitions for immersion service. In equipment safety terms, the tape layer can be counted as solid insulation only when it is fused without voids and when the required number of wraps is verified; creepage and clearance calculations should follow IEC 60664-1 for the relevant overvoltage category.

    Standard codeTest propertyRelevance to T1010-B004-12
    ASTM D412-16Tensile strength, ultimate elongationMonitors unfused tape integrity and application elongation limits
    ASTM D2240-15(2021)Durometer hardnessIndicates flexibility of the fused elastomeric overwrap
    ASTM D792-20Specific gravitySupports batch consistency and void estimation
    ASTM D149-20Dielectric breakdown voltageQualifies dry insulation capability of the fused coupon
    ASTM D257-14(2021)Volume resistivityAssesses leakage current and contamination sensitivity
    ASTM D471-16Fluid resistanceValidates compatibility with oils, solvents, and hydraulic fluids
    ASTM D573-04(2019)Elevated-temperature agingSupports high-temperature service-life qualification

    In comparison with pressure-sensitive adhesive PVC tapes, the T1010-B004-12 does not rely on a hydrocarbon adhesive layer that can soften at elevated temperature or exude plasticizer onto connector pins. In comparison with butyl mastic tapes, it does not form a heavily tacky mass over the connection and can be opened for rework with less substrate contamination. In comparison with heat-shrink tubing, it can be applied without heat tools and without cutting the connector body free. These differences define the service conditions under which the product is used; they do not make the product universally suitable. For bonding to a substrate or for direct adhesion to metal surfaces, a silicone adhesive transfer tape or a primer would be required because the T1010-B004-12 has no initial tack.

    Self-fusing ethylene propylene rubber tapes are frequently used in cable-joint insulation. Compared with an EPR tape, a silicone self-fusing tape typically offers a wider high-temperature service window but may have different tensile strength, elongation, and solvent compatibility. The T1010-B004-12 is selected where silicone elastomer compatibility with existing wire insulation, re-enterability, and high-temperature oxidation resistance are primary constraints. For medium-voltage splices requiring stress-control geometry, a separate semi-conductive stress-control tape is still required; the T1010-B004-12 is an insulating overwrap and is not a stress-control layer.

    When connector re-entry or harness rework is required after extended service

    The fused silicone overwrap is removed by cutting with a controlled-depth cutter and peeling the layer from the connector. Because the tape has fused into a largely monolithic elastomer, an uncontrolled blade can nick the underlying cable jacket. Maintenance crews using fixed-depth hooked blades reduce the risk of jacket damage. The product does not leave an adhesive residue when removed from clean substrates, but silicone oil or plasticizer residue from adjacent components may transfer onto the connector surface during service. Removal procedures should include a solvent-cleaning step before reapplication. The removed tape layer cannot be reused because its fusion interfaces have consolidated and cannot be reactivated reliably.

    Cable harnesses in engine compartments and industrial machinery expose the overwrap to cyclical vibration and thermal cycling. The silicone elastomer retains low-temperature flexibility across the range relevant to many wire insulation systems, but the fused layer does not provide the same longitudinal strain relief as a moulded boot or an adhesive-lined heat-shrink connector covering. Thermal cycling between cold soak and high operating temperature can cause differential expansion between the fused silicone layer and the underlying polymer jacket; the overwrap is applied with controlled tension that does not constrict the cable bundle but maintains layer contact. Vibration testing of fused harness assemblies should include random vibration profiles on representative connector geometries because the damping contribution of the silicone overwrap depends on layer thickness and wrap coverage.

    Field failures observed in production environments often involve mixing adhesive-backed tape with self-fusing tape in the same splice. Adhesive residue from adjacent PVC tape migrates onto the self-fusing tape outer surface and blocks fusion of subsequent layers. Work instructions should prohibit alternating adhesive and self-fusing tapes unless a separation layer or cleaning step is used. Contaminated gloves carrying mold-release agents from other elastomer components can also suppress layer amalgamation and produce a visible interlayer seam. On-site quality checks after application include visual inspection of edge uniformity, layer count, and tail fusion; destructive peel checks may be used periodically to confirm that the fused layer separates by cohesive tearing rather than by interlayer peeling.

    Application tooling and tension-control boundaries on semi-automated wrapping lines

    Semi-automated wrapping machines for harness tape are set to a constant unwind drag. The drag setting is qualified against tape elongation measurements; a higher drag setting increases elongation and may reduce the number of wraps required for a given wall, but it also raises the risk of necking and width reduction. Tension is measured with a spring force gauge at the payout roll, and the wrapping-head speed is matched to the roll width to avoid edge flutter. Process windows should be established with the actual roll configuration because the T1010-B004-12 liner and backing stiffness affect unwind behaviour. The product is intended for controlled wrapping rather than high-speed adhesive lamination.

    General-purpose silicone elastomers are subject to swelling after prolonged exposure to aromatic hydrocarbons, chlorinated solvents, and certain phosphate ester hydraulic fluids. The T1010-B004-12 should not be specified for continuous immersion in these media unless fluid-resistance testing under ASTM D471-16 demonstrates acceptable retention of tensile, elongation, and dielectric properties. For service involving fuel, engine oil, or de-icing fluid, a fluorosilicone tape may be more appropriate if the supplier’s fluid-resistance data support the substitution. The product is also not intended as an oxygen-barrier coating for copper conductors in direct contact with acidic corrosion products; the underlying metal should be cleaned and passivated before overwrapping.

    The tape is stored flat or hung by the core in original packaging, away from direct sunlight and heat sources. High storage temperature can accelerate liner adhesion changes and reduce unwind ability. At low temperature, roll stiffness increases; the material should reach room temperature before application because cold silicone elastomer may exhibit reduced conformability. Shelf life is assigned by the manufacturer and may be lot-specific; users should request a shelf-life statement for the T1010-B004-12 roll configuration. Inventory rotation should follow first-in first-out practice unless a longer shelf-life extension is supported by retest data under the original specification.

    Regulatory conformity must be verified from the supplier’s material declaration for the specific part number. General statements for the T1010 series should not be assumed to cover every roll configuration or all sales regions. If the application falls under REACH, RoHS, or aerospace AMS requirements, the part-specific declaration should be requested during design review. When the tape is used in vacuum or optical applications, the outgassing potential of volatile siloxane species should also be assessed by the user against the relevant acceptance limit.

    Top