| HS Code | 324578 |
| Manufacturer | Rogers Corporation |
| Brand | ARLON |
| Series | A3030 |
| Part Number | A3030-R012-12 |
| Product Type | Self-fusing tape |
| Material | Silicone rubber |
| Color | Red |
| Thickness | 0.012 in (12 mil) |
| Width | 0.5 in (1/2 in) |
| Length | 12 yd (36 ft) |
| Adhesive | None (self-fusing) |
| Temperature Range | -65°F to 500°F (-54°C to 260°C) |
| Dielectric Strength | 400 V/mil |
| Dielectric Constant | 3.0 at 1 MHz |
| Dissipation Factor | 0.003 at 1 MHz |
| Volume Resistivity | 1.0 x 10^14 ohm-cm |
| Tensile Strength | 900 psi |
| Elongation | 400% |
| Water Absorption | <0.1% |
| Shelf Life | 5 years |
| Rohs Compliant | Yes |
As an accredited Rogers Corporation ARLON A3030-R012-12 Self-fusing tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Packaged as a cardboard case containing 12 rolls; each self-fusing tape roll is individually wrapped for protection. |
| Container Loading (20′ FCL) | 20′ FCL loading: Rogers ARLON A3030-R012-12 self-fusing tape, palletized, shrink-wrapped, secured, kept dry, stowed per transport and safety regulations. |
| Shipping | Shipping description: Rogers Corporation ARLON A3030-R012-12 Self-fusing tape is not regulated as a hazardous material/dangerous good. No UN number, hazard class, or packing group required. Transport as non-hazardous cargo in secure packaging, protected from heat, moisture, and damage, per carrier and local regulations. |
| Storage | Store Rogers Corporation ARLON A3030-R012-12 Self-fusing tape in a cool, dry, well-ventilated area in original packaging. Keep away from direct sunlight, heat, sparks, open flames, moisture, dust, and incompatible materials. Avoid extreme temperatures and maintain recommended storage limits. Keep containers closed when not in use. Rotate stock, use first-in, first-out, and follow SDS/label instructions. Store as per manufacturer. |
| Shelf Life | Shelf life is 5 years from date of manufacture when stored in original packaging at 23°C (73°F) and 50% RH. |
In a petrochemical plant where 6.6 kV feeder cable routes between substation switchgear and compressor skids are repaired during 72-hour turnaround windows, the Rogers Corporation ARLON A3030-R012-12 self-fusing tape is installed as an outer re-enterable insulation envelope rather than as a permanent buried joint. The installation procedure is written around IEC 60079-14 area-classification constraints for Zone 2 cable joint work and requires that the completed inline splice pass a 4-hour insulation resistance test at 1000 V DC before re-energisation; the tape itself is subjected to dielectric strength verification in accordance with ASTM D149-20 using a 25 mm guarded electrode assembly, with sustained voltage of 10 kV on a 0.51 mm cured film being recorded for acceptance in the plant laboratory. The application ratio for a 6.6 kV feeder is three half-lapped layers over a fully bonded stress-control mastic, corresponding to an axial overlap of 50% and a tape consumption of 2.1 linear metres per linear metre of joint envelope; the first pass is applied at 20–30% tensile elongation, the second pass at 10–15% elongation, and the final pass is laid without tension to retain conformability over the connector body. In production practice, maintenance crews have documented that using a battery-powered constant-tension applicator set to 0.5 N·m output torque reduces thickness variation across the joint to ±0.08 mm, whereas purely manual wrapping produced a ±0.25 mm variation that shifted the partial discharge inception voltage by 25% in one test sample. The downstream process flow begins with jacket stripping and aluminium conductor crimping, followed by solvent wiping with a low-residue aliphatic hydrocarbon and surface abrasion to 0.8 µm Ra; after mastic dressing, the tape is wound from cable jacket to cable jacket with a 25 mm minimum bond onto the original outer sheath, and the assembly is then covered with a UV-cured polyurethane coating to protect against process-area hydrocarbon drip. Terminal product types for this installation class include temporary 6.6 kV motor feeder joints, emergency bypass jumpers during compressor trip events, and switchgear cable termination adaptors that remain in service until the next planned outage.
In aircraft wire-shop production documents, the typical wrap for a 20 AWG fluoropolymer-insulated copper conductor routed through an unpressurised pylon bay is two half-lapped layers of self-fusing silicone tape, and the upper layer count is governed by added mass and allowable bend radius rather than dielectric margin. A two-layer wrap at 50% overlap increases bundle diameter by approximately 1.6 mm and raises the minimum bend radius by 12% when the harness is qualified to SAE AS50881 bend-radius rules; addition of a third layer is permitted only where the harness passes through a titanium bulkhead grommet and the bend radius remains above 35 mm. The compliance path for flammability is 14 CFR 25.853(a) Appendix F Part I vertical burn, with a self-extinguishing time not exceeding 15 s and burn length not exceeding 152 mm; for compartments adjacent to optical sensors, the tape is also tested to ASTM E595-15 with total mass loss below 1.0% and collected volatile condensable material below 0.1%. The downstream process in a harness shop involves cutting the tape length from a 12-yard roll, pre-stretching the first 100 mm to release liner memory, then applying the tape from the connector backshell forward with a 50% overlap and 25% elongation measured on a calibrated spring scale. The terminal product types include engine pylon, landing gear and bleed-air sensor harnesses where the tape replaces fluoropolymer spiral wrap because of vibration-induced chafing at bay penetration points; the production planning allowance for tape usage is 2.1 m of tape per linear metre of harness at two layers plus 150 mm end tabs.
A diesel-electric vessel’s freshwater-cooled alternator terminal box and its cable entry are sealed with a half-lapped self-fusing tape dressing to maintain IP56 ingress protection during engine room washdown cycles. The applicable acceptance criterion is derived from IEC 60529 for the terminal box enclosure, and the tape sealing layer is selected only after a water-absorption check following ASTM D570-22 shows less than 1.5% mass uptake after 24 h immersion at 23°C; classification societies may additionally require type-approval documentation for the adhesive-free seal when the cable entry is located below the 46 mm minimum height above deck plates in bilge zones. The application ratio is 3 layers at 55% overlap, with a cured film thickness of 0.25 mm per layer and an overall sleeve thickness under the stainless steel dress guard of 0.75 mm ±0.1 mm; the first layer is stretched 40% to force silicone-to-silicone fusion, the second layer is applied at 20% elongation to reduce entrapped air, and the outer layer is applied without tension and covered with a solvent-resistant acrylic lacquer. In shipboard maintenance, the fitting process begins with removal of the original nylon stuffing gland, insertion of a neutral-cure oxime silicone paste fillet around the cable jacket, and a 10-minute skin time at 23°C before tape winding; the tape is then wrapped with a 400 W hot-air gun held at 120°C and 150 mm distance to accelerate layer fusion, though curing does not require heat. Terminal products for this scenario include thruster motor feed junctions, emergency fire pump motor terminations, and navigation light distribution-box entries that are exposed to intermittent saltwater spray but not continuous submersion.
| Application zone | Reference standard | Measurement condition | Acceptance window |
|---|---|---|---|
| Petrochemical MV joint | IEC 60502-4, ASTM D149-20 | 25 mm guarded electrode, 50 Hz | 10 kV on cured film; 4 h insulation resistance at 1000 V DC |
| Avionics harness | 14 CFR 25.853(a), ASTM E595-15 | Vertical Bunsen burner; vacuum outgassing | ≤ 15 s flame; burn length ≤ 152 mm; TML ≤ 1.0%; CVCM ≤ 0.1% |
| Marine terminal box sealing | IEC 60529, ASTM D570-22 | 24 h immersion at 23°C | Water uptake ≤ 1.5%; enclosure to IP56 |
| Railway connector boot | EN 45545-2 | Small interior non-listed item fire hazard | HL2; R23 overboot required |
| EV battery test leads | IEC 60664-1:2020, IEC 61010-031:2015 | Pollution degree 2, overvoltage category II | 2500 VDC for 60 s |
| ESP cable splice | IEEE 1018-2013, API RP 11S4 | Conductor-to-armor hipot after immersion | 5 kV DC; crimp resistance ≤ 5 µΩ |
Rolling stock inter-car jumper cables and traction converter cubicle wiring use a self-fusing tape at connector boot-to-cable transitions where heat-shrink sleeves cannot be installed without hipot retest of the connector. Under EN 45545-2, the tape surface outside the connector boot must not create a fire hazard above HL2 when tested as a small interior non-listed item, and the assembly is normally overcoated with an intumescent mastic and a glass-fibre braid to meet the R23 seat of fire risk category. The installation ratio is two half-lapped layers at 50% overlap, yielding a nominal added radial thickness of 0.5 mm ±0.1 mm; in traction motor thermocouple harnesses the overlap is raised to 60% to resist cleaning-solvent ingress. The downstream production process begins with crimping the barrel connectors, then wrapping the joint from cable jacket over the boot and back to jacket so that no metal barrel edge contacts the tape directly; a calibrated tension fixture set to 25% elongation is used to avoid necking the tape below 70% of its original width. Terminal product types include train control cables, brake resistor wiring, and traction motor terminal boxes on multiple-unit rolling stock; the tape is not specified as a sole fire barrier in floor-level passenger compartments.
In an 800 VDC battery module discharge test cell, sense leads that pass through thermal chamber walls are dressed with the tape to prevent flashover to grounded fixtures and to maintain lead flexibility during repeated plug insertion. The dielectric coordination is checked against IEC 60664-1:2020 for pollution degree 2 and overvoltage category II, while the assembled test lead is hipot-tested at 2500 VDC for 60 s according to an internal test specification derived from IEC 61010-031:2015. The application ratio for a 1000 VDC potential class is 4 layers at 50% overlap; for 500 VDC sense leads the number is 3 layers, giving a total wrap thickness of 1.0 mm and 0.75 mm respectively after fusion. In production, the wire bundle is first cleaned with 70% isopropanol and then the tape is applied by a bench-top winder that controls rotation speed at 120 min⁻¹ and tape tension at 2 N; after 24 h at 23°C the wrap is cut with a rotary blade rather than peeled. Terminal products are battery cycler sense-lead harnesses, thermal chamber feedthrough cable assemblies, and high-voltage isolation test leads used in cell formation equipment.
For electrical submersible pump cable splices in oil well service, the tape is used as a temporary outer dressing before a potted splice is completed or as a water-excluding wrap on motor lead extension connectors that are retrieved within 30 days. The operational boundary is set by mechanical damage from downhole tubing rather than by the silicone tape’s temperature rating; published data for long-term exposure of this specific tape in downhole brine at 150°C and 500 bar is limited, so the splice design conservatively assumes the tape contributes no pressure containment. The relevant industry documents include IEEE 1018-2013 for electric submersible pump cable insulation and API RP 11S4 for installation and handling; the splice must pass a 5 kV DC conductor-to-armor hipot after 1 h water immersion before the cable is run into the well. The application ratio is 4 layers at 55% overlap over each conductor, with an additional 2 layers overall across the splice body; each layer is tensioned to 20% elongation and inspected for wrinkles before the next lay. The downstream process is: armour is removed, conductors are spliced with hex crimp dies to a resistance below 5 µΩ, each splice is coated with an impermeable mastic, the tape is wound from lead sheath to lead sheath, and a stainless steel armour clamp is installed over the dressing. Terminal products include ESP motor lead extension splices, packer feedthrough junction boxes, and downhole gauge cable connections that are removed on a scheduled well intervention schedule.
Competitive Rogers Corporation ARLON A3030-R012-12 Self-fusing tape prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Rogers Corporation ARLON A3030-R012-12 is an unsupported, self-fusing silicone rubber tape supplied as a dry roll without a pressure-sensitive adhesive layer. The product is used as a primary or secondary electrical insulation wrap on cable harnesses, splices, termination bodies, and irregular connector transitions where a conformable dielectric shell must be built up in place. The part-number suffix encodes dimensional information: the R012 block corresponds to a nominal thickness class of 0.012 in (0.30 mm), while the trailing 12 is a roll width or length identifier whose exact value must be checked against the procurement specification. Self-fusing behavior means that the tape bonds only to itself when one convolution is pressed over another; it does not wet copper, aluminum, XLPE, or PVC substrate surfaces. The absence of an adhesive interphase removes tackifier migration and residual adhesive transfer, but it places stricter demands on wrap tension, surface cleanliness, and layer overlap. Published data for this specific configuration is limited; certified physical and electrical values should be obtained from the supplier lot certificate rather than from generic silicone-tape literature.
The tape is built on a filled silicone elastomer. The filler package influences tear resistance, surface finish, and the rate at which adjacent wraps become inseparable. In self-fusing tapes, the silicone matrix is compounded with a controlled degree of molecular mobility. When one layer is pressed against another, polysiloxane segments interdiffuse across the interface and entangle. Over time at room temperature, the boundary develops into a continuous elastomeric mass. Because the tape is unsupported, the resulting wall contains no woven scrim or film carrier; this permits high elongation but reduces cut-through and tear resistance relative to reinforced glass-cloth or film-backed tapes.
The fusion process is contamination-sensitive. A monolayer of fingerprint oil, release agent, dust, or cable-jacket plasticizer can produce a boundary that fails a voltage-withstand or peel check even after the outer surface appears fused. Production-scale observations on wrapped busbar and harness lines show intermittent fusion defects concentrated at the tape edges where handling is most frequent. Operators should handle the roll by the core or use nitrile gloves. If bare-hand contact occurs on an outer lap that will be slit from the finished build, the affected layer should be removed.
A single flat wrap of unsupported tape is not an insulation system until overlapping layers have fused into a continuous wall. In manual and semi-automatic application, the most common geometry is half-lapped: each revolution advances approximately 50% of the tape width, yielding two tape layers at every point. A four-layer build therefore requires eight half-lap passes. The final wall is not simply 4 × 0.012 in unless tension is controlled; excessive stretch reduces the thickness and width of each ply. The tape should be applied with enough tension to establish intimate contact but not enough to cause necking. Published process data for this specific configuration is limited; for general silicone self-fusing tapes of this gauge class, width reduction greater than 10–15% after a fixed wrap length is commonly used as a signal of excess tension. That figure is a process qualification starting point, not a certified manufacturer limit.
Entrapped air is a critical defect. Air pockets become low-density regions with lower dielectric strength and can separate the layers. A soft roller or manual burnish after each pass helps consolidate the wrap. On production machines, a compliant pressure wheel placed at the point of laydown improves contact without cutting the sheet. The wrap should be started after the roll has equilibrated to shop temperature; a cold roll may be less pliable and may fuse more slowly than a room-temperature roll.
Electrical acceptance is not determined by visual appearance. The fused assembly should be tested according to ASTM D149 for dielectric breakdown voltage or a device-level hipot standard. Because breakdown voltage is thickness-dependent, results are reported as volts per unit thickness or compared at a fixed build. A gentle peel check at a lateral overlap should not reveal the original tape surface; if it does, pressure was insufficient or the surface was contaminated.
Compared with adhesive-coated tapes, the self-fusing product shifts field failure modes from adhesive softening and ooze to fusion-boundary failure and cut-through. On wrapped motor connections located near varnish and winding potting compounds, adhesive tapes can soften because the adhesive layer has a lower continuous-use temperature than the backing. A self-fusing silicone wrap does not contain that adhesive complement and is selected for higher thermal exposure. The trade-off is that the tape cannot hold loose lead wires during assembly; an external tie or friction-tape stay is required until the wrap is consolidated. No pressure-sensitive adhesion is available for fixturing.
On semi-automatic taping heads, dancer-arm tensioning must be matched to the gauge of the product. A magnetic-particle brake cannot simply be copied from a PVC adhesive-tape process because the silicone tape has a different modulus and yield behavior. If the taping-head speed is increased without resetting tension, the roll may become uneven and folded at the edges. The drive roll should be inspected for wear; a worn drive roll can scuff the tape surface and create a contaminant line along each wrap. Cut-through and puncture resistance should be evaluated where the tape wraps over sharp solder splashes, cable-tie tails, or metal braid. A single layer of 0.012 in unsupported silicone is easily cut; the design should provide a build-up of at least two or three layers before contact with a sharp edge, or a separate abrasion tape should be used.
| Tape class | Bonding mechanism | Rework consequence | Primary test reference |
|---|---|---|---|
| Self-fusing silicone | Interlayer fusion under tension | Clean shell removal after slitting | ASTM D149, ASTM D412 |
| Adhesive-backed vinyl | Rubber-resin pressure-sensitive adhesive | Adhesive residue and possible jacket plasticizer migration | ASTM D1000 |
| Mastic | Cold-flow adhesive mass | Difficult to remove; scraping often required | ASTM D1000 or supplier specification |
| PTFE thread tape | Mechanical deformation, low friction | No fused shell; rework possible but no elastomeric wall | Supplier thread-seal specification |
| Ethylene-propylene rubber fusion tape | Dry interlayer fusion | Similar shell formation but different polymer chemistry | ASTM D412, ASTM D149 |
The comparative table is a selection guide, not a substitute for qualification. Exact values for dielectric strength, tensile strength, elongation, and fluid resistance depend on the lot and the test conditions. ASTM D149 dielectric tests should be conducted on the completed wrap thickness, not on a single unmounted strip, because layer fusion and air entrapment dominate field performance. Incoming inspection should condition the roll at 23 ± 2°C and 50 ± 5% relative humidity for at least 24 h before thickness or tensile measurements are compared with datasheet limits. Testing outside those conditions can introduce bias, especially in thickness and stiffness.
Cold storage increases the modulus and reduces the conformability of an unsupported silicone sheet. A roll removed from a low-temperature warehouse may be stiffer at the edges and may not lie flat on small-diameter cables. If the roll surface is below the ambient dew point, condensation forms when the bag is opened; the resulting liquid water can be trapped at the interface and prevent fusion. The roll should be equilibrated in a sealed bag before use. The warm-up interval depends on roll diameter and air velocity, and no universal time is valid. A practical rule is to hold the sealed roll in the application area until the surface temperature matches the room within 2–3°C; thermocouple or infrared measurement is preferred to time-based estimates.
Application under humid conditions above 50% relative humidity may require dry-air wiping of the substrate. The tape is not a moisture-cure system, so ambient moisture is not required for fusion; liquid water is detrimental. If condensation is present on a cable jacket or terminal body, the wrap should not be started until the surface is dry. The same restriction applies after solvent cleaning; isopropyl alcohol is frequently used, but it must evaporate fully before wrapping because residual solvent can become trapped in the build.
An adhesive-backed vinyl electrical tape bonds immediately to the substrate through a pressure-sensitive rubber-resin layer. It can be used for light-duty insulation and color coding, but the adhesive layer may soften at elevated temperature and transfer residue during rework. Plasticizers in vinyl backings can migrate into adjacent polymer jackets. A self-fusing silicone tape avoids those adhesive-related limitations but has no tack; it cannot be applied loosely and expected to remain in place before the first overlap is secured.
Mastic tapes are cold-flow adhesive masses used for sealing irregular connections and corrosion protection. They adhere aggressively to the substrate and are difficult to remove cleanly. A self-fusing silicone tape forms a separable elastomeric shell after slitting; the shell does not flow into crevices in the same manner as mastic. When void-filling and adhesion are required, mastic may be used beneath a silicone overwrap, but the two materials serve different functions.
PTFE tapes used for thread sealing rely on low friction and deformation to fill threads. They are not self-fusing and do not build an elastomeric insulation wall. Silicone self-fusing tape is used where a conformable dielectric covering is needed rather than a low-friction seal. For chemical exposure, PTFE has broader resistance to aggressive solvents and acids, while silicone may swell in fuels, aromatics, ketones, and chlorinated solvents. ASTM D471 immersion testing is the appropriate method for evaluating volume swell in candidate fluids.
Ethylene-propylene rubber self-fusing tapes are mechanically similar but chemically different. The choice between silicone and EPR is usually governed by thermal class, fluid compatibility, and mechanical abuse. Silicone systems retain useful flexibility over a wide temperature range and resist oxidative embrittlement, but they generally have lower cut and tear resistance than many heavy EPR tapes. The A3030-R012-12 product should not be selected for abrasion resistance without a specific wear test.
A common point of misuse is applying the tape as a sole fluid barrier in continuous immersion. Silicone elastomers can undergo substantial volume swell in nonpolar hydrocarbon fluids. If the application includes fuel or solvent contact, the construction should be qualified by ASTM D471 immersion testing at the service temperature. Where the tape is used as an outer wrap over a cable jacket, the jacket should be cleaned with a solvent that does not damage the elastomer. Roll storage should be in a sealed polyethylene bag at 20–25°C, away from ozone-generating equipment and direct sunlight. Partial reels should be kept sealed; contamination from handling cannot be washed off reliably without knowing the cleaner’s effect on the silicone surface.
Common process-derived defects include start-end lifting, fusion voids, thickness thinning, cut-through at sharp edges, and solvent-induced swelling. Each failure mode is traceable to a specific process variable:
Elastomeric materials are notch-sensitive. A nick at the edge propagates under tensile load. If the roll edge is damaged during transit, the damaged edge should be trimmed away. In production, rotary shears are preferred over manual knives for slitting because a scissor-cut edge can impart periodic points of weakness. The tape is insulating, not a stress-control or semiconductive material; electrical field grading at high-voltage terminations must be achieved with separate materials. Regulatory compliance statements for REACH and RoHS should be documented for the specific lot, and the tape should not be treated as a replacement for adhesive-lined heat-shrink tubing where an adhesive seal or a uniform factory-formed wall is required.