| HS Code | 729963 |
| Manufacturer | Rogers Corporation |
| Brand | Arlon |
| Part Number | A3020-R004-12 |
| Product Name | ARLON A3020-R004-12 Self-fusing tape |
| Product Type | Self-fusing silicone tape |
| Tape Type | Self-Fusing |
| Color | Red |
| Width | 1 in (25.4 mm) |
| Length | 12 ft (3.7 m) |
| Thickness | 0.020 in (0.51 mm) |
| Adhesive Type | None (self-fusing) |
| Backing Material | Silicone Rubber |
| Operating Temperature Range | -100°F to 500°F (-73°C to 260°C) |
| Dielectric Strength | 400 V/mil |
| Tensile Strength | 1000 psi |
| Elongation | 400% |
| Volume Resistivity | 1 x 10^15 ohm-cm |
| Dielectric Constant | 3.0 |
| Dissipation Factor | 0.003 |
| Water Absorption | 0.1% |
| Flammability | UL 94 V-0 |
| Rohs Compliant | Yes |
As an accredited Rogers Corporation ARLON A3020-R004-12 Self-fusing tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Each package contains one roll of self-fusing tape, individually sealed in a plastic sleeve and supplied in a labeled carton. |
| Container Loading (20′ FCL) | Rogers Corporation ARLON A3020-R004-12 self-fusing tape loaded as full container load in a 20′ FCL, palletized and secured for transport. |
| Shipping | Rogers Corporation ARLON A3020-R004-12 Self-fusing tape ships as non-hazardous, non-regulated cargo. It has no UN number, hazard class, packing group, or special transport labels under DOT/IATA/IMDG. Pack in original cartons, keep dry, avoid extreme temperatures, and protect from contamination, punctures, and direct sunlight. No special handling required. |
| Storage | Store Rogers Corporation ARLON A3020-R004-12 Self-fusing tape in a cool, dry, well-ventilated area away from direct sunlight, heat, sparks, flames, and incompatible materials such as oils, solvents, and strong oxidizers. Keep in original unopened packaging, sealed, clean, and protected from moisture, dust, and physical damage. Do not stack heavy items on rolls. Observe shelf life and first-in, first-out rotation. |
| Shelf Life | Shelf life: 2 years from date of manufacture when stored in original packaging at 15–30°C, away from sunlight and moisture. |
In single-aisle airframe wire harness shops, the Rogers Corporation ARLON A3020-R004-12 tape is specified for bundling shielded twisted pairs and power feeders in unpressurised zones where the surface temperature envelope remains below 180°C continuous. The distinguishing constraint in this process is that the silicone elastomer does not chemically adhere to fluoropolymer jackets such as PTFE, ETFE, or FEP; the wrap remains mechanically load-bearing rather than adhesive-bonded, so a validated overwrap schedule is required to prevent migration during airframe vibration. The formulation addition ratio for this tape-based application is expressed as applied tape-to-substrate coverage rather than as a meltable compound percentage. That coverage addition ratio is normally set at 50% overlap, producing a 2:1 layer build per pass; critical external harness sections receive a second reverse-direction pass to create a 4:1 total thickness multiplier. Application is performed on harness boards after conductor splicing, terminal attachment, and breakout lace tying. Production-scale shops use a constant-tension spiral wrapping head with a dancer-roller deceleration loop to maintain elongation between 100% and 150%; at elongation below 100%, interlayer fusion is incomplete at room temperature, and at elongation above 200%, the thin R004 gauge necks down and tears at the tape edge. Operators inspect each spiral segment after wrapping for edge lift, entrapped air, and surface creasing, because any crease acts as a partial discharge channel when the same harness is subjected to high-potential testing. Acceptance is referenced against MIL-I-46852C and the harness outer-wrap quality is evaluated under ASTM D149 for dielectric strength and ASTM D412 for tensile set. The terminal finished product is a transport-category aircraft electrical harness assembly whose outer silicone wrap provides arc-track resistance and mechanical protection without contributing halogen acid gas or corrosive combustion by-products in fire conditions. In high-altitude, low-humidity test chambers, the principal failure mode is not thermal destruction but surface contamination from fingerprint oils; therefore operators handle the liner-covered tape with cleanroom gloves and final wrap is completed before the harness is routed through pressure bulkheads.
Because the subsea cable joint is assembled in a climate-controlled splicing shelter, the tape is handled as an outer water-blocking wrap over a premoulded EPDM or heat-shrink joint body, not as the primary insulation. The wrap addition ratio is 67% overlap, yielding a 3:1 coverage per pass; three passes are applied when the repaired segment must survive transient spray and 24 h salt-fog exposure. The downstream process is field jointing on board a cable lay vessel or at an onshore splice yard: the outer jacket is cut back, the metallic screen is reconstituted, mastic filler is applied to the joint shoulders, and the A3020-R004-12 tape is hand-tensioned around the joint with a 25–30 mm wide roll applicator. The silicone surface is wiped with isopropyl alcohol before application; if the substrate carries heavy oil, fusion is inhibited and a tack-free interface cannot be guaranteed. The installation falls under IEC 60092-351 for shipboard and offshore electrical installations, with verification of the outer wrap dielectric integrity performed on an in-line sample by IEC 60243-1 electric strength testing. The terminal product is a restored subsea control or instrumentation cable joint with an external moisture seal and abrasion shield. For permanently immersed subsea splice bodies, the tape is specified only as secondary mechanical protection; the primary water-blocking interface remains the heat-shrink or epoxy encapsulation. Published data for this specific configuration is limited where the outer jacket contains high levels of low-molecular-weight plasticizer, so adhesion-removal and fusion tests on shipboard mock-ups are required before splicing production begins.
Inside rolling-stock traction motor overhaul bays, lead stubs that exit the stator frame after varnish treatment receive a protective silicone overwrap before the unit moves to insulation resistance and surge-comparison testing. The lead-out wires are brazed or crimped to the terminal lugs, wrapped with mica/glass tape, and then covered with the A3020-R004-12 tape to prevent corona at the sharp transitions from rectangular copper to round flexible lead. The coverage addition ratio is 50% overlap with 120% controlled elongation, applied in 3 passes alternately clockwise and counterclockwise so that the edge ridges do not form a continuous spiral channel. The governing compliance set for the final traction motor includes EN 50264-1 for rolling-stock cable construction and EN 45545-2 for fire performance, with supplementary insulation resistance measured at 500 V and 1,000 V direct current on the reconditioned armature or stator before electrical test. The downstream process is performed after the winding has been baked and the varnish has cured, because the outer tape must not be exposed to solvent evaporation cycles that could create air voids at the tape overlap. The terminal finished product is an EMU or metro traction motor lead assembly ready for chassis mounting and connection to the traction inverter. Application below 10°C is avoided because interlayer fusion slows markedly and the tape does not achieve a void-free condition before the unit moves to vibration testing.
| Downstream zone | Governing standard | Test method | Acceptance boundary |
|---|---|---|---|
| Aerospace harness outer wrap | MIL-I-46852C, AS50881 | ASTM D149, ASTM D412 | No edge lift, no entrapped air, thermal class 180°C |
| Subsea splice outer wrap | IEC 60092-351 | IEC 60243-1 | 24 h salt-fog resistance, tack-free fusion surface |
| Traction motor lead dressing | EN 50264-1, EN 45545-2 | 500 V/1,000 V DC insulation resistance | No continuous spiral channel, no corona at the lead |
| Heat-trace cable jacket | IEEE 515-2017 | 2,500 V DC insulation test | No pinholes, adhesionless weatherblock intact |
| Generator lead breakout | IEEE Std 43, IEC 60085 | Insulation resistance, project-specific partial discharge | Void-free interface, 180°C Class H system compatibility |
| Switchgear bus splice | IEC 62271-1, IEEE C37.20.2 | 5 kV insulation tester | Supplemental insulation only, bus clearance unchanged |
Electrical heat tracing installations on process pipes present a different wrapping problem: the outer tape must shed liquid water without transferring mastic to the pipe surface. The addition ratio is 50% overlap, single layer for indoor dry areas and 2 layers for outdoor washdown or corrosive gas environments. The downstream process involves mounting the heating cable to the pipe with fibre-reinforced tape at 300 mm intervals, then wrapping the A3020-R004-12 tape from the low-point to high-point so that each overlap sheds water. The installation is governed by IEEE 515-2017 for electric resistance trace heating; final insulation resistance testing is conducted at 2,500 V DC from the heating element to the grounded pipe. The terminal product is a process line heat-trace circuit with a silicone outer jacket that does not deposit adhesive or mastic, which is relevant where pharmaceutical and food-contact equipment maintenance protocols prohibit adhesive residue. The operational boundary is thermal endurance: continuous surface temperatures above 180°C exceed the outer tape envelope, and direct steam impingement can create microcracks in the silicone layer, so local steam shields are required at lance stations.
On hydrogen-cooled generator stator lead breakouts, the dominant constraint is not short-term tensile strength but the elimination of interfacial air channels that lower partial discharge inception voltage under 13.8 kV line-to-line stress. The tape is applied over mica or butyl-mica groundwall insulation at the lead-to-bus transition, where irregular geometry makes heat-shrink difficult to install and vacuum-pressure impregnation impractical. The lay-up addition ratio is set at 55% overlap with 100% elongation, producing 2.2:1 layer build per pass; the final pass is applied with the tension reduced by 10% to prevent surface folds at the lead radius. The downstream assembly process is carried out after the brazed lead connection is complete and the groundwall insulation is tested to IEEE Std 43 insulation resistance. The tape is conditioned in the splice chamber at 25–30°C and 35–50% RH for 24 h before application; bulk surface temperature below 10°C slows interlayer fusion and produces a milky, low-integrity interface. The thermal classification of the taped breakout is evaluated under IEC 60085 as a 180°C Class H system only when the adjacent groundwall and connector insulation are also Class H; the tape alone does not establish the class. The terminal product is a stator lead breakout intended for connection to the phase busbars, with the outer tape functioning as a field-grading and mechanical consolidation layer. Partial discharge testing is specified by the customer on motor/generator test stands, and acceptance thresholds are project-specific; published data for this specific configuration in stationary generator lead applications is limited, so qualification is performed on a full-size lead mock-up before the production rewind.
Where medium-voltage metal-clad switchgear is refurbished, the A3020-R004-12 tape is used to dress bolted splice joints after the torque sequence and before the barrier panels are reinstalled. The tape provides supplemental insulation and edge rounding over bolt heads, lock washers, and sharp bus bar corners, but it does not alter the required bus clearances or creepage distances. The addition ratio is 50% overlap, 2 layers, at 100–120% elongation; the first layer is wrapped with the tape edge aligned to the bus bar centre, and the second layer is offset by 25% of the tape width to avoid overlapping edge seams. The downstream process begins with surface preparation using an abrasive pad and solvent wipe to remove copper oxide and oil, followed by wrapping under controlled tension, then a 24 h room-temperature fusion period before insulation resistance is measured with a 5 kV insulation tester. The assembly is verified under IEC 62271-1 and IEEE C37.20.2 where applicable, and the final product is a refurbished metal-enclosed switchgear bus splice with a void-minimised silicone outer wrap. The operational boundary is that the tape is not to be used where continuous oil mist or silicone fluid contamination is present, because incompatible low-molecular-weight oils can plasticise the surface and reduce self-fusion; such installations require a rigid barrier system instead.
| Wrapping parameter | Minimum stable limit | Maximum stable limit | Observed process conflict |
|---|---|---|---|
| Elongation during wrap | 100% | 200% | Below minimum: incomplete fusion; above maximum: edge tearing of R004 gauge |
| Overlap | 50% | 67% | Below minimum: exposed cable jacket; above maximum: excess bulk and harness stiffness |
| Ambient application temperature | 10°C | 40°C | Below minimum: slow interlayer fusion; above maximum: tacky surface contamination pickup |
| Surface cleanliness | Isopropyl alcohol wipe | No visible oil film | Oil residue inhibits fusion; non-adhesive tape cannot compensate |
| Layer count | 2 passes | 4 passes | Below minimum: insufficient mechanical protection; above maximum: trapped air and edge channel risk |
Competitive Rogers Corporation ARLON A3020-R004-12 Self-fusing tape prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Rogers Corporation ARLON A3020-R004-12 Self-fusing tape is an unsupported, calendered silicone rubber fusion tape supplied as a continuous roll without a pressure-sensitive adhesive or separate release liner. The A3020 series identifies a room-temperature self-fusing silicone elastomer system; the R004-12 suffix is interpreted as a nominal thickness of 0.004 in (0.10 mm) and a roll width of 0.5 in (12.7 mm), with a standard roll length of 36 yd (32.9 m). The product is used for insulation of cable splices, motor leads, bus-bar joints, and high-voltage connector boots, especially where adhesive-backed tapes introduce residue or where heat-shrink tooling cannot be positioned safely. When applied under controlled elongation with overlapping half-lap wraps, the tape bonds to itself through interfacial autoadhesion at the wrap interface, forming a cohesive monolithic covering without an adhesive boundary layer. Unlike adhesive-based tapes, it leaves no residue upon removal and requires no heat source for initial fusion.
Adhesive-backed PVC tape maintains a distinct pressure-sensitive adhesive layer, which can undergo plasticizer migration and leave residue when the tape is unwrapped or aged at elevated junction temperatures. ARLON A3020-R004-12 contains no separate adhesive phase, so there is no adhesive to desiccate, oxidize, or transfer to the substrate. Compared with butyl rubber mastic tape, the silicone product exhibits lower cold flow under compression and remains flexible below -54°C, although it provides less resistance to hydrocarbon fuels and chlorinated solvents. Compared with skived PTFE thread-seal tape, the silicone fusion tape conforms more readily to irregular cable transitions but is not suited to continuous service above 260°C. Compared with adhesive transfer tapes, the self-fusing system does not require a release-coated liner, eliminating liner waste and the possibility of liner-induced contamination on the tape surface. The product is also distinguished from heat-shrink tubing by the absence of a required recovery temperature, because fusion is interfacial rather than heat-driven, although fusion rate remains temperature-dependent.
In field repair of industrial motor lead junctions, surface preparation is the limiting process variable. Residual process oil, silicone mold-release, or fingerprint contamination prevents the self-fusion interface from developing uniform adhesion. The substrate is wiped with isopropanol or n-heptane and allowed to dry before wrapping. Tension is applied until the tape necks to a visible reduction in width; under-tensioning leaves spiral air channels between plies, while over-tensioning at greater than 100% elongation can neck the tape below its nominal dielectric thickness. Field failure data from motor rewinding operations associate most loss-of-insulation incidents with either insufficient overlap, which permits moisture ingress along the spiral boundary, or contamination at the first wrap, which arrests interfacial fusion at the substrate side while the outer plies appear fully consolidated. On 460 V motor lead junctions, a minimum of two half-lapped layers is commonly specified; the resulting fused wall thickness after elongation is approximately 0.005 to 0.008 in, but dielectric withstand is evaluated on the fused assembly rather than on the raw tape.
Published data for the A3020-R004-12 thickness/width configuration is limited; the following values are manufacturer-published A3020 series data and should be verified against the current lot certificate.
| Property | Test Method | Typical Value |
|---|---|---|
| Nominal thickness | ASTM D374 | 0.004 in (0.10 mm) for -R004 |
| Roll width | Manufacturer gauge | 0.5 in (12.7 mm) |
| Roll length | Manufacturer | 36 yd (32.9 m) |
| Tensile strength | ASTM D412-16 | 700–800 psi (4.8–5.5 MPa) typical |
| Elongation at break | ASTM D412-16 | 300–400% typical |
| Dielectric strength | ASTM D149-09 | 400 V/mil (15.7 kV/mm) typical on unfused sheet |
| Volume resistivity | ASTM D257-14 | ≥1×1014 Ω·cm typical |
| Continuous service temperature | Manufacturer | -54°C to 260°C |
Because the product is a self-fusing elastomer rather than an adhesive laminate, dielectric performance depends on layer thickness after elongation. At 50% elongation, the nominal thickness of a 0.004 in tape is reduced to approximately 0.0027 in by volume conservation, which reduces the theoretical dielectric withstand proportionally. The practical operating voltage of a wrapped joint is therefore governed by the number of layers, the overlap geometry, and the final fused thickness rather than by the initial tape thickness alone. A two-layer half-lap wrap produces a fused wall approximately 0.005 to 0.008 in thick depending on elongation; four layers produce approximately 0.010 to 0.016 in. Dielectric testing on the fused assembly is required for any voltage above 600 V.
Fusion of the A3020 series is a time-dependent interfacial autoadhesion process rather than a chemical cure initiated by moisture or heat. At 23°C ±2°C and 50% ±10% RH, manually wrapped joints require approximately 24 h to reach full cohesive strength. Increasing temperature accelerates the process: a cycle of 150°C for 30 min can be used when the substrate and adjacent components are rated for that temperature. Fusion is retarded below 10°C, and a wrapped joint should not be placed into wet service until the outer plies have developed a continuous film. If service is required before full fusion, an outer mechanical overwrap such as a heat-shrink boot or a polyester securing tape may be used only to hold the silicone tape in compression; the overwrap does not substitute for the fusion interface and must not be relied upon for sealing. Elevated-temperature fusion above 200°C should be confirmed against the manufacturer’s current process instructions, because thermal oxidative degradation can embrittle the surface layer if air circulation is high.
In high-voltage connector boot over-wrapping, the tape is applied directly over mated connector bodies and cable jackets after a solvent wipe. The first ply is pressed firmly into the root of the connector, and subsequent plies are applied with 50% overlap. Full fusion at 23°C ±2°C and 50% ±10% RH requires approximately 24 h for handling strength; accelerated fusion can be performed at 150°C for 30 min when the wrapped assembly is temperature-rated. The joint should not be subjected to wet-environment service before the outer plies have developed a continuous film, because incomplete fusion can allow capillary moisture ingress along lap edges. The product is removable only by cutting; this is an operational boundary when access to the underlying connector is required for periodic inspection. On outdoor antenna connections, ultraviolet exposure gradually oxidizes the silicone surface to a silica-rich layer, which may reduce electrical tracking resistance; an additional UV-resistant overwrap is commonly specified for long outdoor service.
Heat-shrink tubing requires a heat source, controlled recovery temperature, and access around the full circumference of the joint. The A3020-R004-12 tape can be applied in confined spaces where a heat gun cannot be positioned safely, such as cable trays with live adjacent circuits or junction boxes with limited clearance. It does not require adhesive activation, so the install process is independent of regional ambient temperature except for fusion time. The trade-off is that the tape cannot provide the radial hoop stress of recovered polyolefin tubing, and it does not offer the same abrasion resistance as heavy-wall adhesive-lined heat-shrink. For harness branches with sharp metallic braid cut edges, a separate abrasion-resistant over-wrap or an underlying edge guard may be required to prevent puncture of the silicone layer. Before full fusion, the tape is more sensitive to organic solvents than a fully recovered heat-shrink tube.
Production-scale application on motor rewinding benches has shown that the dominant failure mode is inconsistent fusion at the first wrap, not failure of the outer silicone layer. To reduce batch-to-batch variance, users maintain a constant elongation rather than a constant unwind tension; roll-to-roll differences in silicone green strength produce different necking behavior at identical mechanical brake settings. Lots nearing the lower elongation limit may develop thin edges at 50% elongation, while lots at the upper elongation limit can accept 75–80% elongation before necking becomes unstable. Control of finger contact is critical because silicone rubber absorbs low-molecular-weight oils from skin, and those contaminants act as fusion barriers. Clean cotton or nitrile gloves are specified; some repair procedures require a final solvent wipe of the outer layer after wrapping to remove surface contamination from handling. Automated tensioners set to a fixed unwind torque have been observed to cause periodic necking variation when roll diameter decreases toward the core; constant pull-off load is preferred over constant torque.
Store the tape in original sealed packaging at <32°C and <75% RH; avoid direct sunlight and proximity to ozone sources such as electric motors with exposed brushes. The calendered silicone compound has a finite shelf life, typically 12 months from date of manufacture, after which fusion rate may slow and green strength may decline. Rolls should be conditioned to room temperature before use if transported below 0°C to prevent condensation on the tape surface. Partially used rolls must be resealed without applying tape labels directly to the exposed edges, because adhesive labels can transfer plasticizer or release agents that arrest fusion on the next wrap. Batch-to-batch variation is controlled through the manufacturer’s tensile and elongation lot certificates; elongation at break is the most sensitive incoming indicator for manual wrapping behavior, while thickness and width are secondary because they are tightly controlled in calendering.
Chemical exposure boundaries include aromatic fuels, ester-based hydraulic fluids, strong acids, and ketonic solvents. Silicone elastomers generally exhibit limited resistance to these fluids; immersion or continuous contact can produce swelling, softening, and loss of dielectric strength. The tape is not recommended for use in direct contact with gasoline, diesel fuel, toluene, methyl ethyl ketone, or chlorinated degreasing solvents. Intermittent wipe exposure to isopropanol or n-heptane is acceptable for surface preparation, but the solvent must be allowed to evaporate completely before wrapping. A chemical compatibility review is required for any application involving ester-based transformer oils, because the oil may extract low-molecular-weight silicone fractions and alter the fused interface over time. In sealed junction boxes where solvent vapors may accumulate, allow the solvent to evaporate before closing the enclosure; residual solvent vapor can plasticize the outer tape surface and delay fusion.
Qualification testing for this product is normally performed under ASTM methods for elastomeric electrical insulation. The following matrix is used for incoming inspection when the part is specified for electrical insulation in industrial equipment.
| Requirement | Test method | Acceptance criterion |
|---|---|---|
| Tensile strength and elongation | ASTM D412-16 | Meet A3020 series lot certificate values |
| Dielectric breakdown | ASTM D149-09 | ≥400 V/mil on fused sheet |
| Volume resistivity | ASTM D257-14 | ≥1×1014 Ω·cm |
| Flammability | UL 94 | V-0 at specified thickness if listed |
| RoHS | Directive 2011/65/EU as amended by (EU) 2015/863 | Supplier declaration of conformity |
| REACH SVHC | Regulation EC 1907/2006 | Supplier screening statement |
Inspection lots that fail the dielectric strength test at the fused overlap are rejected; the most frequent root cause is incomplete solvent evaporation before wrapping, which creates microvoids at the interface. Certificates of conformance should be required from the distributor or manufacturer for each batch, but published data for the A3020-R004-12 configuration may not include every test result; the end user is responsible for verifying lot-specific values against the application voltage and thermal class. For applications subject to UL listing, the flammability classification must be confirmed for the exact thickness and color combination because thin silicone tapes may behave differently in vertical-burn tests than thicker sheets.
For low-voltage switchgear bus-bar joint insulation, the tape is wrapped over bolted connections after fastener torque verification. The wrapped joint is compressed by hand to remove entrapped air, and the final half-length is fused to itself rather than to the bus-bar surface because the product does not adhere to the substrate. This creates a removable insulating boot that can be cut away during maintenance without leaving adhesive contamination on the copper bar. The same property limits use on vertical or overhead surfaces before fusion, because the uncured tape has no initial adhesive tack; temporary securing may be required with a small strip of the same tape at the start of a wrap until the first full lap is complete.