Products

Rogers Corporation ARLON A2020-R004-12 Self-fusing tape

    • Product Name: Rogers Corporation ARLON A2020-R004-12 Self-fusing tape
    • Factroy Site: Yinchuan, Ningxia, China
    • Price Inquiry: sales8@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 153823
    Manufacturer Rogers Corporation
    Brand Arlon
    Product Name A2020-R004-12 Self-fusing Tape
    Part Number A2020-R004-12
    Product Type Self-fusing tape
    Series A2020
    Material Silicone rubber
    Color Red
    Thickness 0.020 in (0.51 mm)
    Width 12 mm (0.47 in)
    Length 4 m (13.1 ft)
    Adhesive Type None (self-fusing)
    Self Fusing Yes
    Operating Temperature Range -60°C to 260°C (-76°F to 500°F)
    Dielectric Strength 400 V/mil (typical)
    Dielectric Breakdown Voltage 8 kV (typical)
    Tensile Strength 800 psi (typical)
    Elongation 400% (typical)
    Volume Resistivity 1 x 10^15 ohm-cm (typical)
    Dielectric Constant 3.0 at 1 MHz (typical)
    Dissipation Factor 0.002 at 1 MHz (typical)
    Water Absorption 0.2% (typical)
    Uv Resistance Excellent
    Ozone Resistance Excellent
    Chemical Resistance Good
    Flame Retardant Self-extinguishing
    Rohs Compliant Yes

    As an accredited Rogers Corporation ARLON A2020-R004-12 Self-fusing tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Packaged as one roll of Rogers Corporation ARLON A2020-R004-12 self-fusing tape per package, individually wrapped and labeled.
    Container Loading (20′ FCL) 20′ FCL container loading: palletized Rogers ARLON A2020-R004-12 self-fusing tape, evenly distributed, secured, and desiccant-protected per shipping requirements.
    Shipping Rogers Corporation ARLON A2020-R004-12 Self-fusing Tape is classified as non-hazardous for shipping. It requires no UN number, hazard class, or placards. Transport in original sealed packaging, keep dry, avoid excessive heat and sunlight, and comply with applicable carrier and local regulations.
    Storage Store Rogers Corporation ARLON A2020-R004-12 self-fusing tape in a cool, dry, well-ventilated area away from direct sunlight, heat, sparks, flames, and strong oxidizers. Keep original packaging closed, clean, and off the floor. Protect from moisture, dust, oils, solvents, and physical damage. Maintain ambient temperature, typically 15–30 °C, and rotate stock first-in, first-out.
    Shelf Life Shelf life is approximately five years from date of manufacture when stored in original packaging under cool, dry conditions.
    Application of Rogers Corporation ARLON A2020-R004-12 Self-fusing tape

    In unpressurised aerospace harness branch-outs, the alphanumeric designation R004-12 identifies a 0.004 in nominal thickness product in a 12 in roll width; the tape is converted into narrow slit spools and applied over fluoropolymer-insulated conductors, solder sleeve terminations, and pre-installed connector backshells where heat-shrinkable sleeving cannot be slid over the connector body. The wrap functions as a secondary electrical insulation consolidator, not as primary insulation, and is installed with a 50% overlap under continuous tension; the tail end is pressed into the underlying layer so that the self-fusing silicone interfaces merge into a homogeneous elastomer ring after 24 h at 20–25 °C. Installations are performed to AS50881 wiring practices, and flammability or smoke requirements are screened under DO-160G where the airframer has qualified the tape for a specific zone. During production, liner removal must be verified at the dispensing head because interleave fragments can become entrained in the wrap and create dielectric voids; narrow slit rolls are often tensioned through a closed-loop dancer before final spiral wrap to avoid the tape necking associated with visual width loss. For acceptance, the wrapped harness section is subjected to a withstand voltage representative of the aircraft electrical system, typically 1.5 kV AC for 115 V AC circuits, but the exact test value is set by the platform electrical wiring interconnection system qualification. The wire bundle is then overwrapped with aramid lacing tape or braided sleeving where abrasion from airframe rib edges or adjacent hydraulic lines is anticipated because the self-fusing silicone surface has low cut-through resistance compared with PTFE-based primary insulation. This application is limited to intermittent mechanical strain; continuous flexing at the branch-out can break the fused interface if the tape is not stabilised by an external lacing layer or strain-relief boot.

    What Limits Partial Discharge Inception in Taped Busbar Joints?

    Partial discharge inception in silicone-taped busbar joints is governed primarily by interfacial air trapped at overlap edges, insufficient tape tension, and particulate contamination on the conductor or insulation surface. A busbar joint repair using ARLON A2020-R004-12 is prepared by removing oxide films and sharp burrs, radius dressing edges to at least 0.5 mm, and cleaning the surface with isopropanol followed by a dry lint-free wipe. The tape is spiral-wrapped with a 50% overlap, and each turn is pressed down to eliminate blisters; an outer wrap of semiconducting or shield screen may be used where the joint is part of a shielded switchgear compartment. The critical processing window is ambient temperature: below 10 °C the self-fusing bond strength development is retarded, so the taped joint should be held at 20–25 °C for 24 h before partial discharge testing. Partial discharge screening is performed in accordance with IEC 60270, with acceptance typically set at 10 pC or below at the specified test voltage for medium-voltage equipment; the exact acceptance threshold must be taken from the switchgear specification. Dielectric withstand is checked using ASTM D149 on a representative coupon, and insulation resistance is measured at 500 V DC per ASTM D257. In production, the bolt access gap remains re-enterable because the tape is removed by a longitudinal slit without adhesive residue, but repeated opening destroys the fused edge and requires complete re-wrapping. This material should not be used as the only insulation over a sharp-edged bus bar segment; edge radius dress and a final glass-fibre or mica overwrap are mandatory for switchgear compartments classified for internal arc or high-voltage withstand.

    Standard/test codeMeasured propertyEnd-use application link
    ASTM D149Dielectric breakdown voltage and short-time withstandBusbar joint and traction splice electrical acceptance
    ASTM D257Volume and surface resistivityInsulation resistance after tape fusion
    ASTM D412Tensile strength and elongation at breakTape elongation control and necking threshold during spiral wrapping
    ASTM D2240Durometer hardnessIncoming batch consistency and fused interface rigidity
    ASTM D4388Classification of electrically insulating tapeProduct specification and supplier quality release
    IEC 60270Partial discharge magnitudeVoid detection in busbar joints and taped motor lead dressings

    No external heat is required for the traction power feeder splice wrap.

    Traction power feeder splices in subway tunnels and electrified rail corridors often carry a standing hot-work prohibition; the taping process uses only mechanical tension and surface pressure, so open-flame or hot-air shrink tooling is eliminated. The splice is first covered with a semiconducting layer or solvent-resistant mastic to smooth irregular contours, then ARLON A2020-R004-12 is applied at 50% overlap with a spiral wrapping tool set to a controlled elongation. A second layer is wound in the opposite direction at 50% overlap to create crossed fusion seams and reduce moisture ingress along spiral joint lines. The splice must not be coated with uncured amine-based epoxy putty immediately before taping because amine blush at the surface can inhibit silicone-to-silicone self-fusion. Where the splice is in an underground/metro environment, the material and completed wrap must meet the fire, smoke, and toxicity limits of EN 45545-2 hazard level HL3 or NFPA 130, depending on the rail authority; the supplier’s declaration should be checked against the relevant R22/R23 clauses before installation. Cold conditions in winter maintenance depots are a bottleneck: if the cable surface is below 10 °C, the self-fusing bond does not develop uniformly, so the repair tent is preheated to 20–25 °C and the completed splice is held for 24 h before insulation resistance is measured. Carbon dust from collector shoes and tunnel atmosphere must be removed with a solvent wipe and tack rag because carbon particulates act as a conductive contaminant at the fusion interface. The finished splice is re-enterable, leaves no adhesive residue, and is overjacketed with a UV-resistant, fire-rated heat-shrink or braided polyester sheath where the tunnel environment includes water spray or mechanical abrasion. Electrical acceptance after completion generally uses 1 kV DC or higher megger tests for 60 s, with exact voltage derived from the traction power system voltage class and the rail operator’s maintenance standard.

    On form-wound stator bars, the end-turn region presents a compound curvature that requires a conformable overwrap to hold mica tape and felt blocking in position before vacuum pressure impregnation. ARLON A2020-R004-12 is applied over dry mica tape as a temporary consolidation layer and is spiral-wrapped at 50% overlap without excessive tension; excessive tension compresses the mica tape edges and can wrinkle the underlying tape, while insufficient tension leaves blisters that later become resin-rich or resin-starved zones. The tape must be removed before vacuum pressure impregnation if the resin system is epoxy or polyester because residual silicone contamination on the groundwall surface can reduce resin adhesion and create dry spots; this is a critical incompatibility. If the tape is used after vacuum pressure impregnation as a lead dressing wrap, the surface must be cleaned with isopropanol and the wrap must not bridge the slot exit in a way that traps resin or blocks final heat aging. Acceptance of the completed winding insulation follows IEEE 43 insulation resistance limits and IEC 60034-18-31 with partial discharge screening at line-to-ground voltage; the self-fusing tape is not part of the groundwall insulation system and does not receive a voltage stress grading credit. Motor service shops record the tape width after wrapping because a reduction in width indicates necking and loss of overlap; typical width reduction should remain below 5% when tension is properly set, but the exact limit is derived from shop work instructions and supplier data.

    Silicone Tape Compatibility with Hydraulic Oil Mist in Steel Mill Cable Repairs

    Steel mill cable repairs operate in an environment of continuous hydraulic oil mist, iron oxide dust, and conductive carbon deposits, which create a surface contamination risk for self-fusing tapes. ARLON A2020-R004-12 is used as an inner restorative layer over damaged ethylene-propylene rubber or chlorinated polyethylene cable jackets after mechanical damage from coil handling, but only when the cable surface is first degreased with a solvent such as heptane and then wiped with isopropanol. The tape is wrapped at 50% overlap, pressed into the underlying layer, and covered with a laminated aluminium-foil or polyester outer tape to prevent oil absorption; continuous immersion in mineral oil or hydraulic fluid plasticises the silicone and reduces interfacial fusion strength, so the application is limited to intermittent splash exposure. When relative humidity exceeds 60%, a pre-drying step at 30–35 °C for 15–30 min is applied before wrapping to prevent entrapment of conductive surface moisture. Compatibility with hydraulic fluids is evaluated by immersion testing per ASTM D471 using the specific mill fluid; if the volume swell exceeds the user’s acceptance limit, the tape is not approved for that fluid. Batch-to-batch surface tack is checked with a durometer per ASTM D2240 and a fused overlap peel specimen, but a formal peel adhesion value should not be taken from ASTM D1000 because the product is not a pressure-sensitive adhesive tape. The terminal cable is returned to service with a two-layer silicone wrap and an external abrasion-resistant sleeve, with insulation resistance measured after 24 h at 20–25 °C; in high-humidity or oil-mist conditions, the repaired section is inspected for bubbling or edge lifting before re-energisation.

    For vacuum furnace thermocouple bundles and mineral-insulated cable transitions, the tape is applied only on the ambient side of feedthroughs and terminal strips, not on the hot zone, because silicone outgassing and thermal decomposition can contaminate heating elements and vacuum gauges. The wrap consolidates multiple mineral-insulated thermocouple cables into a re-enterable bundle, allowing probe replacement without adhesive residue; it is installed with 50% overlap and then overbound with stainless steel tie wire or polyimide tape. If the application requires a vacuum-compatible material, total mass loss and collected volatile condensable material are tested per ASTM E595-15, and published data for this specific A2020-R004-12 configuration is limited; the user must screen the tape before chamber installation. The terminal product is a removable thermocouple harness that simplifies furnace profiling and reduces the risk of accidental thermocouple disconnection during retort movement. This application is classified as a shallow processing zone because the established wrapping procedure is well defined and no critical threshold is encountered outside the standard 20–25 °C fusion window.

    When Salt Fog and UV Exposure Govern Offshore Cable Joint Maintenance

    Offshore crane and pump cable joints subjected to salt fog, high UV, and cyclic condensation require a self-fusing layer that excludes water from the connection while remaining removable for periodic inspection. ARLON A2020-R004-12 is applied over a clean, dry cable jacket with 50% overlap; salt deposits are removed with deionised water and isopropanol before wrapping because sodium chloride at the fusion interface prevents formation of a continuous elastomer surface and creates a moisture path. The wrap is built up in two layers applied in opposite helical directions, with each layer pressed down to remove air; the second layer’s overlap is offset from the first to avoid aligned seam lines that can channel water under hydrostatic pressure. The finished joint is protected from UV and mechanical damage by a black polyolefin heat-shrink outer sleeve with an adhesive lining, or by a seawater-resistant braided jacket, because a self-fusing silicone tape alone is not considered a permanent outer sheath in offshore cable systems. Electrical compliance follows marine installation standards, including IEC 60092-350 for shipboard and offshore cables and IEC 61892-6 for offshore electrical installations; the user should verify the supplier’s declaration against RoHS Directive 2011/65/EU and REACH SVHC obligations before import into EU-operated vessels. Insulation resistance is measured at 500 V DC after 24 h of fusion, and the joint is subjected to a dielectric withstand test based on the cable’s rated voltage; exact test voltage is derived from the vessel electrical specification. The self-fusing tape must not be applied directly over sharp edges of copper screening tape; those edges are dressed with a semiconducting or mastic layer before wrapping to prevent puncture during cable flexure.

    Free Quote

    Competitive Rogers Corporation ARLON A2020-R004-12 Self-fusing tape prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Rogers Corporation supplies the ARLON A2020-R004-12 self-fusing silicone rubber tape as a 0.020 in (0.51 mm) nominal-thickness, 12 in (304.8 mm) wide, red-colored roll good. The product code distinguishes the 0.020 in thickness, red pigmentation, and 12 in web width from companion Arlon self-fusing tapes. The tape is manufactured without a pressure-sensitive adhesive layer; bonding occurs when overlapping surfaces are pressed together and siloxane chain segments interdiffuse across the interface to re-establish a continuous network. Typical published datasheet values for this configuration include a tensile strength near 800 psi (5.5 MPa) and elongation at break near 300% when tested under ASTM D 412, a dielectric strength of 400 V/mil (15.7 kV/mm) under ASTM D 149, and a volume resistivity near 1 × 1015 Ω·cm under ASTM D 257. The continuous service temperature range is cited from -54°C to 260°C. Primary application focus includes electrical insulation and environmental sealing in motor manufacturing, transformer lead protection, bus bar joint overwrap, and high-voltage cable harness repair. Because the tape contains no adhesive interlayer, it does not exhibit acrylic or rubber pressure-sensitive adhesive oozing at elevated temperature, and it can be removed by cutting through the fused silicone wrap rather than by solvent cleaning of adhesive residue. In comparison with PVC and EPR tapes, the A2020-R004-12 formulation provides a silicone thermal class and compatibility with silicone-jacketed cables, but its lower tensile strength and tear resistance require confirmation when mechanical reinforcement is part of the design envelope.

    How Does Self-Fusing Silicone Differ from Adhesive-Backed Electrical Tapes?

    Adhesive-backed PVC electrical tape relies on a pressure-sensitive acrylic or rubber adhesive layer to bond to a substrate; the PVC film remains a separate thermoplastic phase and typically softens above 105°C. In A2020-R004-12, the entire tape cross-section consists of a filled polysiloxane composition. Bonding occurs after contact pressure and time, when siloxane chain segments migrate across the interface and re-establish a continuous network; this process does not require solvent evaporation or hot-melt adhesive flow. The practical consequence is that the silicone tape maintains a continuous service temperature of 260°C and does not leave an adhesive residue when cut for rework. Compared with ethylene-propylene rubber self-fusing tape, which is frequently specified for cable splices, EPR products are generally rated for 130°C to 150°C continuous service and exhibit higher tensile strength than unreinforced silicone. Compared with silicone PSA tapes, A2020-R004-12 does not include a coated adhesive film; PSA-backed silicone tape may bond to cold substrates more quickly, but the adhesive layer can become a weak point under thermal cycling or chemical exposure. The self-fusing boundary in A2020-R004-12 is therefore intended for overlapped wrap geometries, not for butt splicing without wrap overlap.

    In motor manufacturing cells, the tape is applied over brazed or welded lead connections before the stator receives varnish impregnation or encapsulation. The 12 in parent roll is usually slit into narrower widths at the winding station; hand tension is set below 0.5 lb/in of web width because higher tension causes silicone neckdown and localized dielectric thinning. A half-lap wrapping schedule is used to produce two layers of insulation, and a roller is passed over the wrap to reduce entrapped air at the overlap. After curing, the wrap is subjected to hipot testing under ASTM D 149 at production voltage; wet-out of the interface is necessary to avoid partial discharge from void formation. For bus bar joints, the tape is wrapped over irregular hardware where heat-shrink sleeving cannot be repositioned. Multiple half-lap passes are built up to achieve the required dielectric thickness; operators limit unwinding speed to avoid blocking on the roll and apply a final tensioning pass to consolidate layers. The material has been observed on production lines to block if stored under heavy roll stacking at temperatures above 40°C, so inventory is rotated and rolls are not placed more than three high without edge protection.

    Layer Fusion Kinetics and Shelf-Life Stability in Unprotected Storage

    Fusion is time-temperature dependent. At 23°C, a 50% overlap wrap reaches handling strength after approximately 2 h and full fusion after 24 h. At 100°C, full fusion is typically reached within 2 h. These values are consistent with polysiloxane network interdiffusion and should be verified against current lot-specific certificates because pigmentation and filler loading can shift the cure state. The tape should be stored in original sealed polyethylene packaging at 21°C and 50% RH; shelf life from date of manufacture is generally 12 months. Rolls exposed to humid air do not require oven pre-drying, but surface condensation must be absent because a trapped water film at the overlap prevents polymer contact and reduces bond strength. Solvent wiping of substrates with mineral spirits is acceptable if the solvent is fully evaporated before wrapping; ketone or chlorinated solvent residues can swell the silicone and delay fusion. The tape should not be stored near ozone generators or operating UV lamps because silicone surface oxidation can reduce self-adhesion. Published data for this specific configuration under high-humidity storage is limited, so end users are advised to qualify bond strength at 85% RH when tropical storage is expected.

    When the Tape Is Substituted for Heat-Shrink Sleeving in Field Repair

    If a field repair requires replacing heat-shrink sleeving without disconnecting a conductor, A2020-R004-12 can be wound over the connector or worn jacket. The wrap builds insulation by overlapping layers, so the total thickness at a three-half-lap pass schedule is approximately 0.060 in (1.5 mm), with minor thickness reduction after fusion. The absence of an adhesive liner permits immediate repositioning only during the initial wrap; once full fusion has occurred, the layers cannot be unwound. For low-temperature installations, the tape should be warmed to at least 0°C before application because below -20°C the material stiffens and may crack during flexing. The repaired cable should not be immersed in IRM 903 or ASTM fuel reference fluids for continuous service, because silicone swells in hydrocarbon oils and fuels. The self-fusing layer is not mechanically equivalent to heat-shrink extruded insulation; abrasion resistance is lower, and a separate reinforced overwrap is required in cable tray or rotating equipment applications. In switchgear retrofit contexts, the red color can be used as a visible phase-identification layer under white or gray overwrap, but color change from thermal aging may occur above 200°C without loss of dielectric function. Published data for this specific configuration is limited in relation to long-term UV exposure, so outdoor installations should be protected with a UV-stable overjacket or tape.

    Typical datasheet values for ARLON A2020-R004-12
    PropertyValueReference method or designation
    Nominal thickness0.020 in (0.51 mm)ASTM D 3652/D 3652M-20
    Width12 in (304.8 mm)Manufacturer product configuration
    Tensile strength800 psi (5.5 MPa)ASTM D 412
    Elongation at break300%ASTM D 412
    Dielectric strength400 V/mil (15.7 kV/mm)ASTM D 149
    Volume resistivity1 × 1015 Ω·cmASTM D 257
    Continuous temperature range-54°C to 260°CManufacturer continuous rating
    Roll length36 yd (32.9 m)Manufacturer product configuration

    Material identity is established through batch-release infrared and thermogravimetric analysis

    Raw silicone compound is verified against a certified infrared spectrum and thermogravimetric ash profile to control filler content and cure state before extrusion. A production lot is released only after thickness and width measurements under ASTM D 3652/D 3652M-20 and dielectric strength testing under ASTM D 149. Rogers Corporation manufactures Arlon silicone products under a quality management system registered to ISO 9001:2015; material declarations can be generated to support RoHS 2011/65/EU and REACH EC 1907/2006 compliance for industrial electrical goods. The product is not listed as a food-contact material under FDA 21 CFR, and it is not intended for direct implantation or pharmaceutical contact. Users requiring a specific UL insulation system classification should verify whether A2020-R004-12 is included in the relevant UL material recognition database for the intended insulation system; published data for this exact part is limited. Thermal oxidative stability is typically assessed by heat aging at 260°C for 168 h followed by tensile retention, with retention generally above 50% for silicone formulations; however, lot-specific data should be obtained before qualifying critical motor or transformer programs.

    In high-volume production, the main bottleneck is the room-temperature fusion time. If parts are tested before full fusion, the overlap interface can fail under hipot or produce intermittent continuity. Manufacturers frequently use heated tunnels or infrared banks at 80°C to 100°C to accelerate fusion after wrap application. The tape should not be combined with amine-containing cure inhibitors or exposed to copper corrosion byproducts that catalyze premature silicone embrittlement; acid-generated soldering flux must be neutralized before wrapping. For applications requiring continuous service above 260°C, mica-glass or ceramic textile tapes with silicone binders may be required because unreinforced silicone tape approaches its upper thermal limit. Direct contact with acetic acid-evolving RTV silicone sealants may interfere with fusion at the interface; the sealant must be fully cured before wrap application. Hydrocarbon oils, fuels, ketones, and chlorinated solvents soften cured silicone and reduce mechanical properties, so periodic immersion in ASTM Fluid 101 or IRM 903 is permissible only for short-term compatibility, not continuous service. The product should not be substituted for high-strength structural backings because its tensile strength remains below 1,000 psi (6.9 MPa). In rotating-equipment applications where a bobbin wrap experiences vibration and mechanical abrasion, a secondary retention layer such as a glass-reinforced overwrap is required.

    Top