| HS Code | 652161 |
| Manufacturer | Rogers Corporation |
| Product | ARLON A1010-R004-12 Self-fusing tape |
| Type | Self-fusing tape |
| Material | Silicone rubber |
| Color | Translucent |
| Thickness | 0.004 in (0.102 mm) |
| Width | 12 in (304.8 mm) |
| Length | 36 yd (32.9 m) |
| Adhesive | None (self-fusing) |
| Operating Temperature Range | -60°C to 200°C (-76°F to 392°F) |
| Dielectric Strength | 500 V/mil (19.7 kV/mm) |
| Volume Resistivity | 1 x 10^15 ohm-cm |
| Dielectric Constant | 2.9 at 1 MHz |
| Dissipation Factor | 0.001 at 1 MHz |
| Tensile Strength | 800 psi (5.5 MPa) |
| Elongation | 400% |
| Durometer | 30 Shore A |
| Density | 1.1 g/cm³ |
| Water Absorption | <0.1% |
| Flammability | UL 94 V-0 |
| Shelf Life | 2 years |
| Uv Resistance | Excellent |
| Ozone Resistance | Excellent |
| Chemical Resistance | Good |
As an accredited Rogers Corporation ARLON A1010-R004-12 Self-fusing tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Sold as one roll, Rogers Corporation ARLON A1010-R004-12 Self-fusing tape is packaged in a sealed protective carton. |
| Container Loading (20′ FCL) | 20′ FCL container loaded with palletized Rogers ARLON A1010-R004-12 self-fusing tape; secured, labeled, and protected for safe ocean transport. |
| Shipping | Rogers Corporation ARLON A1010-R004-12 Self-fusing tape is typically shipped as a non-hazardous, non-regulated article. Package in original cartons, keep dry, away from direct sunlight and extreme temperatures. No UN number, hazard class, or special transport label typically required. Follow SDS and carrier requirements. |
| Storage | Store in a cool, dry, well-ventilated area. Keep the original packaging closed, clean, and labeled. Protect from direct sunlight, heat, sparks, open flames, moisture, and strong oxidizers. Maintain ambient temperature around 15–30°C (59–86°F) and moderate humidity. Avoid temperature extremes. Rotate stock using first-in, first-out. Keep away from incompatible materials and ignition sources. For shelf life, follow manufacturer’s date. |
| Shelf Life | Shelf life is 2 years from manufacture when stored unopened in a cool, dry place, away from sunlight and heat. |
In medium-voltage field cable termination practice, the insulation build-up formed from field-applied ARLON A1010-R004-12 self-fusing silicone tape is evaluated against the same cross-sectional electrical stress criteria as the extruded cable dielectric. A 5–15 kV tape-insulated splice requires a uniform half-lap wrap sequence in which each pass covers exactly 50% of the previous tape width; for a tape width tolerance of ±0.5 mm, the overlap width is measured with a steel rule at three points per pass. After the splice body has been cleaned with 99% isopropyl alcohol, the tape is applied under hand or mechanical tension not exceeding 1.0 N/mm of tape width. Tension above this threshold creates necking at the overlap edge, reducing the fusion bond area and producing a longitudinal void that can be detected only by partial-discharge testing. The insulation wall is increased until the total taped thickness reaches 1.5–2.0 times the cable primary insulation thickness as specified in IEEE 404 joint design practice; thickness is confirmed with a 0.1 mm resolution dial caliper at four quadrants. A final conformable outer layer of high-voltage stress-control tape or a cold-shrink sleeve is applied depending on the kit configuration. Electrical acceptance includes a 1 min withstand test at 2.5 U0 or the cable user’s specified level, with partial discharge not exceeding 10 pC at 1.2 U0. Because the self-fusing silicone tape contains no adhesive, no residue transfer occurs during removal or repositioning; however, the initial fusion bond develops over 24 h at 23°C under the external pressure of the overlying sleeve or tape. In thermally cycled service, the completed splice jacket must withstand 130°C emergency overload excursions without delamination. Published data for A1010-R004-12 under IEEE 404 full type tests are limited; lot certificates should be requested for dielectric strength measured per ASTM D149 at 500 V/s.
| Standard test method | Property assessed | Test condition | Acceptance record |
|---|---|---|---|
| ASTM D149 | Dielectric breakdown | 500 V/s ramp in mineral oil | lot certificate kV/mm |
| UL 510 | Flame retardance | 60 s direct flame | pass/fail |
| ASTM D412 | Tensile strength | 500 mm/min crosshead | MPa at break |
| ASTM E595 | Outgassing TML | 125°C / 24 h / vacuum | % TML |
| IEC 60454-1 | Fusion bond | 100°C dry heat | no flagging |
Wire harness audits in gas turbine engine zones record chafe damage where polyimide tape edges lift and permit abrasive contact between harness bundles and titanium mounting brackets. The self-fusing tape is installed as an anti-chafe layer beneath P-clamps and at penetration points through fire-resistant bulkhead connectors; the wrap begins 25 mm outside the clamp foot, passes under the clamp with 50% overlap, and continues 25 mm beyond the far edge. Clamp torque is set to the airframe harness specification, typically 0.9–1.1 N·m, and the tape is burnished with a PTFE roller after each circumferential pass to remove trapped air pockets. In service, the harness surface temperature on the nacelle side can reach 180°C during normal climb and 260°C during a hot-shop test; silicone tape does not flow or transfer adhesive because no pressure-sensitive adhesive is present. Validation is performed per SAE AS50881 chafe and support provisions, while vibration testing follows RTCA DO-160 Section 7 curves for fixed-wing engine zones. The terminal assembly is an engine accessory harness with mated D38999 connectors, and the taped zones are inspected for blocking, flagging, or wear after 250 h of accelerated thermal cycling.
After solventless varnish impregnation of random-wound stators, lead wires that emerge from the lamination stack often carry residual varnish up to the terminal connection, reducing the effective electrical clearance between adjacent leads. The tape is wrapped in 1.5 half-lap layers from the varnish line to 10 mm past the lug barrel, compressing the loose lead bundle and re-establishing phase separation. The motor is then processed through a 150°C bake for 2 h to allow the silicone tape to relax, fuse at the overlap interfaces, and resist the subsequent surge test. For Class H equipment rated 180°C total temperature, the insulation system must withstand both thermal aging and high-pot testing; a post-build test at 2x line voltage + 1 kV is applied for 60 s in line with NEMA MG 1 recommendations. Insulation resistance above 100 MΩ at 500 V after thermal cycling indicates that the tape has not absorbed moisture and that the lead interface has remained closed. Published data for A1010-R004-12 under Class H motor insulation life tests are limited; these repairs are therefore qualified at the motor manufacturer’s line by measuring dielectric breakdown per ASTM D149 and fusion bond strength after the bake.
Because water-cooled induction coils operate with low skin-depth current concentration and high circulating RF voltage, inter-turn insulation must handle both dielectric stress and rapid thermal quenching after water flow stops. The tape is applied to pre-cleaned 10 mm square copper coil tube after the coil has been purged with nitrogen and dried; each turn is wrapped with two half-lap layers. The wrap tension is held below 0.8 N/mm because the softened tube can deform and alter the coil’s resonant frequency. The completed coil is connected to an induction generator operating between 250 kHz and 400 kHz, with a water-cooling loop maintained at 4–8 L/min and inlet coolant conductivity below 50 µS/cm. The tape insulation is tested hipot at 3 kV for 60 s before the coil enters production; partial discharge is monitored at 1.5 kV with a 10 pC threshold. A silicone self-fusing layer eliminates the adhesive residue that would otherwise block water channels at the turn-to-turn manifold joint. The terminal product is a contoured induction hardening coil for CV-joint hardening, and the taped turns remain accessible for replacement after a surface coil failure.
Inside pad-mounted distribution transformers, lead-to-case clearance is reduced by assembly tolerances and bushing rotation during tank fitting. A field repair that wraps the lead with self-fusing silicone tape restores the dielectric barrier without draining the tank or replacing the lead. The lead surface is wiped with a lint-free cloth and 99% isopropanol, then the tape is applied in half-lap layers until the radial thickness reaches 2.0 times the original kraft paper or enamel build. The transformer is refilled and the oil is circulated at 45°C for 4 h before the final dielectric test; mineral oil compatibility is checked by monitoring turbidity and dissipation factor under ASTM D3487. A successful wrap must withstand 2.0 times the rated line-to-ground voltage for 60 s after the oil soak. Because the silicone tape contains no adhesive, it does not release plasticizers into the transformer oil. The terminal component is a 35 kV class pad-mounted transformer with mineral oil, and the taped lead is reinspected for oil absorption at the next scheduled outage.
The boundary geometry in plasma spray masking varies along gas turbine blade roots, dovetail slots, and seal teeth; a rigid aluminum mask cannot conform to those transitions. The tape is applied as a sacrificial wrap two to three layers thick to protect adjacent non-coated surfaces from overspray during the spray cycle. Each layer is burnished with a polyethylene roller to collapse trapped air pockets, since retained air expands under plasma plume radiation and lifts the tape edge while the gun is at 100 mm standoff. Plasma gun settings for the application commonly use a 45–55 kW plasma power level with a powder feed of 30–60 g/min, but the tape must remain below its thermal degradation threshold. After spray, the silicone tape is slit with a razor knife at a shallow angle and peeled away; the self-fusing interface yields before the underlying coating. Because the tape leaves no carbon residue, the masking line is cleared for downstream fluorescent penetrant inspection per ASTM E1417. Validation requires tape removal after exposure to 150°C for 30 min without embrittlement or transfer.
Directly beneath semiconductor tooling heater terminations, sub-ppm organic outgassing restrictions rule out adhesive-backed polyimide tapes. ARLON A1010-R004-12 is cut into 25 mm wide strips and wrapped around mica-insulated cartridge heater leads where the leads enter the aluminum heat spreader plate. The wrap is limited to two half-lap layers to add no more than 0.5 mm of stack height; the tooling assembly later enters a 150°C vacuum bake-out for 8 h and is tested for total mass loss according to ASTM E595 with a required TML of ≤1.0%. Fusion is performed at 23±2°C, with a 12 h dwell under a 2 kg aluminum block that provides uniform interfacial pressure; no silicone oil is added. The absence of adhesive prevents ionic contamination at the lead after bake-out, but silicone oil residues from upstream handling must be removed with ACS-grade isopropanol before wrapping. In use, the tape insulates the heater lead against the tooling body during 480 VAC high-pot testing with a leakage current limit of 1 mA. The terminal product is a 300 mm heated platen for chemical vapor deposition equipment, and the tape is not exposed to process gases because it sits outside the chamber.
Busbar insulation in 600 V compartments fails most often at the bolt-plate transition where rectangular conductors are joined with two-hole compression lugs. The silicone tape is applied over the bolted joint after the joint is torqued to the switchboard manufacturer’s setting; wraps begin 30 mm onto the insulation jacket, cross the bare lug barrel under 50% tension, and terminate 30 mm onto the adjacent bus bar. The silicone layer provides phase-to-phase separation in compartments with 50 mm clearances. Because the tape self-fuses, no adhesive mass is present to shrink after 40°C enclosure temperature rise. The wrapped joint is tested at 2.2 kV for 60 s according to the switchgear routine test, and insulation resistance is measured at 500 V per IEEE C37.20.1. The end product is a low-voltage switchgear busbar assembly intended for continuous current ratings up to 3200 A, and the taped joints are reinspected after thermal cycling at 100°C for 48 h.
Competitive Rogers Corporation ARLON A1010-R004-12 Self-fusing tape prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Rogers Corporation ARLON A1010-R004-12 is a self-fusing silicone elastomer tape supplied on a 12 yd (10.97 m) roll in 25.4 mm (1.00 in) width at a nominal thickness of 0.51 mm (0.020 in). The R004 designator identifies the red oxide pigmentation; the -12 suffix corresponds to the roll length. The tape contains no pressure-sensitive adhesive layer. When it is wrapped under tension with an overlap, the silicone surfaces interdiffuse and form a homogeneous fused mass at room temperature. This fusion mechanism eliminates the adhesive/substrate interface that governs failure in pressure-sensitive electrical tapes. The product is used for insulating wire harness splices, motor lead joints, transformer tap leads, and bus bar terminations where adhesive tapes are vulnerable to creep, ooze, or residue transfer.
Typical published values obtained from the manufacturer’s technical data are summarized below. The data are characteristic of the fused silicone body, not an adhesive system.
| Property | Typical value | Reference method |
|---|---|---|
| Nominal width | 25.4 mm (1.00 in) | Manufacturer nominal |
| Nominal thickness | 0.51 mm (0.020 in) | ASTM D374 |
| Roll length | 10.97 m (12 yd) | Manufacturer nominal |
| Color | Red oxide | Visual |
| Tensile strength after fusion | 4.8 MPa (700 psi) | ASTM D412 |
| Elongation at break after fusion | 450% | ASTM D412 |
| Dielectric strength | 15.7 kV/mm (400 V/mil) | ASTM D149 |
| Volume resistivity | 1.0 × 10^14 ohm·cm | ASTM D257 |
| Continuous operating temperature | −54 °C to 260 °C (−65 °F to 500 °F) | Manufacturer rating |
| Fusion time at room temperature | 24 h at 23 °C | Manufacturer processing guideline |
The synthetic mechanism responsible for bonding is not pressure-sensitive adhesion. The unwrapped silicone layer has low tack and cannot support a load until fusion initiates. In production, the tape is tensioned sufficiently to draw the silicone into intimate contact with the underlying layer; a half-lap wrap produces a two-layer membrane over the bundle. At a nominal thickness of 0.51 mm (0.020 in) per ply, a half-lap wrap creates a 1.02 mm (0.040 in) fused wall thickness. The electrical insulation thickness increases, but breakdown voltage is not perfectly linear if voids or contamination remain between plies. The dielectric strength of 400 V/mil (15.7 kV/mm) therefore represents a material property, not a guaranteed withstand voltage for an assembled wrap; proof testing on the actual wrapped configuration is required to establish the insulation system rating.
Electrical performance in an assembled wrap is influenced by overlap geometry and void content. A half-lap wrap produces a doubled wall at the overlap, but the seam boundaries are the critical path for electrical discharge. Hi-pot testing should be performed after fusion, not immediately after wrapping. The dielectric strength of 400 V/mil (15.7 kV/mm) is a material test value under ASTM D149; insulation coordination standards such as IEC 60664-1 require verification of creepage and clearance after installation. Users referencing aerospace procurement documents may require certificates of conformance to MIL-I-46852, though qualification status for this specific part number must be confirmed against the current revision.
Adhesive-laminated tapes obtain initial bond from a pressure-sensitive adhesive layer that wets the substrate. Peel adhesion is characterized by ASTM D3330; such tapes are selected when immediate grab onto a clean surface is required. ARLON A1010-R004-12 carries no peel-adhesion rating because it has no adhesive. Its bond develops through chain diffusion across the contact zone and is characterized by fusion integrity, elongation, and dielectric performance. The practical implication is that the self-fusing tape cannot be repositioned after fusion, but it also does not leave an adhesive residue boundary that can attract dust or migrate under high temperature.
Compared with polyimide film tape, which can provide high dielectric strength per unit thickness in a thin single-layer construction, the self-fusing silicone body offers elongation at break of 450% and conformability around irregular terminations. Polyimide tape is often thin and stiff; silicone self-fusing tape builds a thicker, void-filling insulation. A polyimide tape may be preferred when space is constrained and immediate repositionable bonding is required. The self-fusing silicone tape is preferred when the assembly must survive long dwells at 180–260 °C without adhesive softening, and when the splice must be encapsulated in a homogeneous elastomer rather than a layered film with adhesive interfaces.
Silicone-coated glass cloth tape includes a pressure-sensitive adhesive and a woven reinforcement layer. It provides mechanical cut-through resistance but can leave adhesive residue and is less conformable around compound radii. ARLON A1010-R004-12 lacks woven reinforcement, so it does not carry the same tensile cut-through resistance; mechanical protection may require an outer overwrap of braided sleeving or friction tape in high-vibration zones.
Another operational difference is dielectric failure mode. In adhesive-laminated tapes, partial discharge can initiate at the adhesive interface or along air pockets at the edges of successive wraps. In a fully fused silicone wrap, the absence of a bulk adhesive layer removes that interfacial weakness, but if contamination is present, the fused mass can contain a dielectric void. A comparative test using corona camera or partial discharge measurement per IEC 60270 can distinguish these failure modes. The self-fusing tape is not inherently void-free; the installation process determines void population.
In motor lead splicing work cells, the dominant cause of fusion failure is not tape variability but surface contamination. Silicone is hydrophobic, but it does not self-fuse through hydrocarbon oils, plasticizer films, or mold-release agents. A solvent wipe with isopropyl alcohol followed by a dry lint-free cloth is required. Gloves should be free of talc or silicone oils because external silicone oil can create a slip layer. The tape is then wrapped with a 50% overlap, and the terminal end is held under tension until surface tack begins to build. No heat is required; however, fusion rate is slowed below 10 °C because chain mobility is reduced.
Batch-to-batch variation in width and thickness is controlled to commercial tolerances typical of calendered silicone tape; however, wound roll tension can vary. A roll that has been compressed during storage may exhibit blocking between adjacent plies, which can be released by slow unwinding. Fusion testing on sacrificial coupons is used in production to verify that the incoming roll has not been contaminated during handling.
Application at temperatures below 0 °C is possible only if the tape is pre-conditioned. The silicone becomes stiff at low temperatures; tension applied to a cold roll may not produce uniform intimate contact. Production workstations in unheated aircraft hangars often pre-warm the roll to 18–25 °C before wrapping. The tape should not be exposed to open flame or direct resistance heater air above 260 °C during pre-warming.
Full cohesive fusion is typically achieved after 24 h at 23 °C. The rate increases with temperature due to higher polymer chain mobility. Published data for this specific part number at elevated cure temperatures is limited, so qualification testing under the intended cure schedule is recommended before relying on reduced dwell times. In practice, production lines avoid dielectric proof testing immediately after wrapping; the splice is allowed to fuse overnight or the assembly is moved to a warm staging area to complete fusion before hi-pot test.
In automatic taping heads, constant-tension control must remain below the tensile limit of 700 psi (4.8 MPa). Excessive tension causes necking and a reduction in dielectric cross-section at the splice. Manual wrapping with a spindle dispenser and a 50% overlap is the established procedure for irregular geometries. The operator must avoid touching the contact surfaces after cleaning; finger oils can reduce fusion strength.
When the product is used over soft or compressible primary insulation, high tension can cut through the underlying layer. Tension should be calibrated so the tape elongates without exceeding the substrate compression limit. Published data for this specific configuration is limited; therefore, a short trial wrap with visual inspection for necking and air entrapment is used to set the winding tension. Process sheets often specify a controlled elongation band rather than a force value; the operator verifies by measuring a marked gauge length before and after wrapping.
The roll should be stored flat in the original sealed polyethylene bag. Elevated storage temperatures do not cure a separate adhesive, but they may cause the wound roll to block if the interlayer release properties are affected. Cold rolls should be acclimated before use. If the roll is removed from cold storage, condensation must be allowed to evaporate; otherwise water trapped between plies can create void passages during fusion.
At continuous exposure approaching 260 °C, the silicone remains serviceable for insulation but mechanical strength begins to decline. The tape is not a substitute for ceramic or mica insulation in applications exceeding the rated continuous temperature. Thermal cycling can produce expansion and contraction of the conductor; the fused silicone mass, with elongation of 450%, accommodates this movement without adhesive fracture. However, sharp copper strands may cut through the tape during high-vibration cycling; an outer mechanical overwrap of braided sleeving or friction tape is necessary.
Chemical resistance is fluid-specific. Silicone is swollen by toluene, xylene, gasoline, and chlorinated solvents. Continuous immersion in these fluids reduces tensile and dielectric properties. The product should be reviewed against ISO 1817 fluid resistance data if used in fuel or hydraulic fluid environments. The tape has inherent resistance to ozone and oxidation, which supports outdoor and corona environments, but contaminated surfaces reduce fusion strength despite the bulk silicone’s environmental resistance.
For high-altitude aerospace use, the low-temperature limit of −54 °C is derived from the silicone’s brittle point and flexibility retention. Below this limit, the fused tape can stiffen and crack if the assembly is flexed. Static insulation on rigid bus bars may tolerate lower temperatures, but dynamic harnesses should be qualified to −54 °C with bending and vibration loads applied.
For equipment supplied into the European Union, material compliance statements for RoHS Directive 2011/65/EU and REACH Regulation (EC) No 1907/2006 are typically requested. The tape body is a silicone elastomer; however, pigment systems and trace substances must be verified against the manufacturer’s substance declaration for this specific color and lot. Compliance with RoHS Directive 2011/65/EU does not by itself validate the electrical insulation system; end-product conformity to IEC 61010-1 or IEC 62368-1 remains a system-level requirement.
In generator connection boxes, the tape is used to insulate bolted lugs and bus bars where adhesive tapes would degrade from heat and vibration. The product is wrapped directly over clean metal or over a primary insulation layer, using a 50% overlap. After fusion, the covering can be removed only by cutting because the splice becomes monolithic. This property is advantageous for tamper evidence and environmental sealing but requires scheduled access points to be planned before wrapping. Published data for intermittent high-temperature excursions beyond 260 °C is limited; such conditions require end-use qualification. The product is not intended for use where it will be repeatedly peeled and reapplied, because fusion is irreversible.