Products

Rogers Corporation ARLON 910-10BxxFR-P1 Self-fusing tape

    • Product Name: Rogers Corporation ARLON 910-10BxxFR-P1 Self-fusing tape
    • Factroy Site: Yinchuan, Ningxia, China
    • Price Inquiry: sales8@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 964621
    Product Name Rogers Corporation ARLON 910-10BxxFR-P1 Self-fusing tape
    Manufacturer Rogers Corporation
    Brand ARLON
    Series 910
    Product Type Self-fusing tape
    Backing Material Silicone rubber
    Adhesive Type Self-fusing (no adhesive)
    Color Black
    Thickness 0.010 in (0.25 mm)
    Width Variable by xx in part number (e.g., 12 mm, 19 mm, 25 mm, 38 mm, 50 mm)
    Length 30 ft (9.1 m)
    Tensile Strength 700 psi (4.8 MPa)
    Elongation 400%
    Dielectric Strength 400 V/mil (15.7 kV/mm)
    Volume Resistivity 1 x 10^14 ohm-cm
    Temperature Range -60°C to 200°C (-76°F to 392°F)
    Flame Retardancy UL 94 V-0
    Water Absorption <1%
    Chemical Resistance Good to water, oils, fuels, acids, and bases
    Uv Resistance Excellent
    Shelf Life 2 years
    Standards UL 510, RoHS, REACH
    Liner P1 (1 mil polyester)

    As an accredited Rogers Corporation ARLON 910-10BxxFR-P1 Self-fusing tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Rogers Corporation ARLON 910-10BxxFR-P1 self-fusing tape is supplied as one individually wrapped roll per package, labeled with product identification.
    Container Loading (20′ FCL) 20′ FCL container loading: palletized cartons of Rogers ARLON 910-10BxxFR-P1 self-fusing tape, evenly distributed, braced, and secured for ocean transport.
    Shipping Typically, Rogers Corporation ARLON 910-10BxxFR-P1 Self-fusing Tape is not regulated as dangerous goods. It ships as non-hazardous cargo under DOT, IMDG, and IATA, with no UN number, hazard class, or packing group. Store dry at room temperature, away from excessive heat and sunlight. Confirm with current SDS.
    Storage Store in a cool, dry, well-ventilated area, away from heat, sparks, open flames, and direct sunlight. Keep original packaging tightly closed, upright, labeled, and off the floor. Maintain 15–30°C (59–86°F), avoiding high humidity, moisture, dust, and incompatible materials. Protect from physical damage. Use first-in, first-out; follow manufacturer shelf-life and temperature limits. Do not stack heavy items on top.
    Shelf Life Shelf life is five years from date of manufacture when stored in original packaging in a cool, dry place.
    Application of Rogers Corporation ARLON 910-10BxxFR-P1 Self-fusing tape

    Under continuous water immersion and residual heat from a wet-well submersible pump motor, the ARLON 910-10BxxFR-P1 self-fusing silicone tape is applied over a fused cable splice to eliminate the peel-prone adhesive interface found in butyl-backed PVC rejacketing systems. On a 600 V submersible pump cable using EPDM-jacketed conductors, the tape is wound over a solvent-cleaned compression connector assembly that has been pre-filled with a nonmelting insulating compound. The relevant compliance path is UL 510 component recognition for insulating tape and ASTM D4388 qualification for nonmetallic rubber tapes, with dielectric strength measured under ASTM D149 short-time conditions and insulation resistance under ASTM D257. The production layup ratio is a 50% half-lap spiral; for a nominal film thickness of 0.254 mm, one 50%-overlap pass produces a 0.508 mm minimum fused wall, and the shop-floor tape consumption is 2.0 m of tape per linear metre of spliced cable per pass. Field repair procedures call for a second 50%-overlap pass reversed in direction, yielding 1.016 mm nominal wall thickness and consuming 4.0 m/m total. The splice is wrapped on a low-speed cable spinning jig with a brake tension of 10–15 N; higher tension above 20 N has been observed on repair benches to thin the tape at butt edges on cable diameters below 15 mm, creating a wedge-shaped fusion deficit. Fusion is compromised if the cable surface dew point is within 3 °C of ambient, so repair bays with relative humidity above 60% must pre-dry the splice with clean compressed air and apply an isopropanol wipe immediately before winding. After wrapping, the assembly is held at 23 ± 2 °C for 24 h or placed in a forced-air oven at 80 °C for 2 h to complete the self-fusion reaction before megger testing at 1000 V DC; pre-fusion energization can reduce the measured insulation resistance below 1 GΩ. Terminal finished products include wet-well submersible pump cable assemblies, mine dewatering pump leads, sewage lift station junction repairs, and rejacketed cable entries in water treatment basins.

    What real-world failure mode justifies silicone tape in high-voltage motor lead dressing?

    Partial discharge at phase-to-phase crossings of random-wound stator leads in traction motors initiates when varnished polyester-glass sleeving becomes brittle after repeated thermal cycles between −40 °C and 180 °C; the resulting cracks expose copper and can lower phase-to-phase partial discharge inception voltage below 1.0 kV at 50 Hz under IEC 60034-18-41 screening conditions. The silicone tape is not a varnish replacement; it is applied as a conformable outer dressing over sleeved leads and lug barrels to close porosity and reduce surface tracking. Qualification in this sector commonly requires UL 510 for tape construction, UL 94 V-0 for flame restraint at the 0.254 mm cured-sheet thickness, and ASTM D149 dielectric breakdown measurement on fused tape specimens. The layup ratio is set at 67% overlap across the first half of each motor lead, which for a 0.254 mm film produces a nominal 0.762 mm fused wall over the lead curvature and consumes 3.0 m of tape per metre of lead; the second pass is reduced to 50% overlap to limit outer diameter growth on leads already occupying tight phase barriers. On an offline motor repair cell, a lathe-type wrapping fixture with servo-controlled carriage speed of 0.3 m/s and unwind tension of 12–18 N is preferred; batch-to-batch variation in tape thickness below ±10% at 0.254 mm has been found acceptable when measured by ASTM D3652, but thickness variation above ±15% creates outer diameter interference with phase separators in framed stators. Contact with aromatic hydrocarbon solvents or chlorinated brake cleaners must be avoided before dressing; solvent swelling reduces tear strength and retards interlayer fusion. After dressing, assemblies are heat-fused at 150 °C for 15 min in a recirculating oven or allowed to self-fuse at 23 °C for 24 h; the shorter heat cycle is used when the motor must pass routine hipot at 2U + 1000 V the same shift. Published data for this specific tape configuration under IEC 60034-18-41 partial discharge testing is limited; the 1.0 kV reference is a screening threshold for motor lead insulation systems, not a product-specific guarantee. Terminal finished products include traction motor stator lead bundles, wound-rotor motor phase leads, synchronous condenser high-voltage jumpers, and railway auxiliary machine terminal assemblies.

    Automated spiral wrapping of avionics harness bundles generally imposes a maximum cover thickness before connector clocking and backshell clamp dimensions are altered; the tape is applied in a 50% half-lap configuration after lacing and before connector overmolding or heat-shrink boot installation. In pressurized avionics bays, the harness bundle is often tested as a whole against 14 CFR 25.853(a) and Appendix F Part I vertical burn criteria, with the tape contributing to the flame-retardant outer layer when paired with halogen-free braided sleeving. The relevant electrical tape qualification continues to reference ASTM D4388 and UL 510 where the tape functions as primary insulation on spliced ground leads and shield terminations. Application over PTFE jacketing requires plasma or chemical surface activation; otherwise fusion to fluoropolymer substrates is negligible. The production layup ratio at the harness cell is 50% spiral overlap, producing 0.508 mm nominal wall thickness from a single 0.254 mm film and consuming 2.0 m of tape per linear metre of bundle; breakout transitions are double-wrapped 75 mm on each side of the branch, consuming an additional 0.3 m per breakout. On a computer-controlled spiral wrap station running 40–80 rpm with closed-loop tension of 5–12 N, the silicone tape’s low compressive yield strength requires line speed de-rating below 0.6 m/s; edge folding on 22 AWG bundles below 10 mm diameter has been observed when tension exceeds 12 N. Full fusion is achieved by 24 h at 23 ± 2 °C or by inline infrared tunnel at 65 °C for 4 h before backshell integration. Terminal finished product types include avionics fan tray harnesses, flight-control cable bundles, cabin power feeder looms, and in-flight entertainment cable assemblies.

    When engine bay harness coverings must withstand 150 °C splash and −40 °C cold-bend without delamination

    The transition between corrugated polyamide conduit and silicone-coated fiberglass sleeving on exhaust-gas sensor leads is a recurring delamination point when adhesive cloth tape is used; the self-fusing silicone tape is selected because it does not rely on an acrylic adhesive that softens above 100 °C. The harness bundle must pass cold-bend testing at −40 °C per ISO 6722-1 or OEM-specific LV 112 requirements, and the tape’s flame performance is checked under UL 94 V-0 on cured sheet; dielectric acceptance uses ASTM D149 after fusion. Direct contact with diesel fuel and hot engine oil must be avoided in areas where continuous immersion in ASTM IRM 901 oil at 150 °C could cause excessive volume swelling; an outer elastomer web sleeve is used in those zones. The wrap ratio is 50% single-pass, yielding 0.508 mm wall over 0.254 mm tape and using 2.0 m per linear metre of lead wire; at the conduit-sleeve transition, a 25 mm double-wrap band is added each side to resist peel-back from engine splash. Harness build boards use pneumatic tensioners set to 8 N, and after wrapping the entire assembly is heat-set in a tunnel at 100 °C for 30 min, allowing fusion to occur before the tape is clamped under connector strain reliefs. Terminal finished products include oxygen sensor leads, knock sensor cables, starter motor battery feed harnesses, and automatic transmission sensor loom branches.

    Reclaiming a damaged trailing cable jacket in underground mining after a roof fall requires the repair crew to restore an abrasion-resistant outer cover without heating a vulcanizer at the face. The tape is applied over a hot-vulcanized splice body that has been cooled to 40 °C and mechanically scuffed with 120-grit carbide cloth to create a contaminant-free surface. The acceptance framework for inherently flame-resistant mining cable repairs in US operations commonly references 30 CFR Part 18 for flame resistance of components and ASTM D4388 for tape electrical performance; the jacket repair itself is not used to establish dielectric strength unless the splice is fully embedded. The layup specification is more aggressive than general electrical repairs: three 50% half-lapped passes applied in alternating directions create a nominal 1.524 mm fused jacket wall from the 0.254 mm film and consume 6.0 m of tape per linear metre of cable length. Hand winding uses a 10–15 N brake tension and a helical angle of 30–40° to the cable axis; field quality audits show that below 10 N tension, entrapped air channels persist between layers and reduce water spray ingress protection, while above 15 N the tape thins at splice shoulders on cable diameters below 25 mm. Fusion is completed at mine workshop temperature 40 °C for 8 h or at ambient 23 °C for 24 h; the repaired cable is megger-tested phase-to-ground at 1000 V DC and must exceed 1 GΩ after 60 s before returning to service. Terminal finished products include continuous miner trailing cables, shuttle car power cables, roof bolter feeder cables, and pump cable sections in longwall mining panels. Published comparative data for this specific tape in 30 CFR Part 18 full-assembly flame testing is limited; the tape is therefore used as a component whose end-use qualification must be verified at the cable-repair facility level.

    Induction furnace coil sleeving and hot busbar insulation overwrap

    On water-cooled copper busbar bends and induction coil jumpers operating at 10 kHz, the tape is applied directly to degreased tinned copper and then overwrapped with glass cloth tape for mechanical protection. The self-fusing silicone layer prevents condensation-driven tracking between adjacent busbar phases and tolerates local surface temperatures up to 180 °C after the coil has been shut down and residual heat soaks through the insulation. Compliance for industrial machinery busbar insulation typically invokes NFPA 79 for electrical equipment protection, UL 510 for tape construction, and ASTM D149 for dielectric strength on fused tape; flame acceptance is verified to UL 94 V-0. The production layup is two 50% half-lapped passes with the outer pass reversed, producing a 1.016 mm fused wall from 0.254 mm film and consuming 4.0 m of tape per linear metre of busbar. Application in the coil fabricator’s cell uses a hand-tensioned dispenser at 10 N; copper surfaces must be acid-free and dry, and any residual drawing oil below the tape prevents fusion at the copper interface. After wrapping, the assembly is baked at 90 °C for 1 h or allowed to stand at 23 °C for 24 h before a 1000 V DC insulation resistance check requiring more than 1 GΩ after 60 s. Terminal finished products include induction melting coil leads, water-cooled busbar assemblies, RF generator feedthroughs, and resistance heating element terminations.

    Free Quote

    Competitive Rogers Corporation ARLON 910-10BxxFR-P1 Self-fusing tape prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    The product identified as Rogers Corporation ARLON 910-10BxxFR-P1 is a self-fusing silicone elastomer tape supplied in roll form without a pressure-sensitive adhesive layer. The designation is interpreted under the 910 series nomenclature: “10” denotes a nominal thickness of 0.010 in (0.25 mm); “Bxx” identifies the color-fill variable for the black or custom-pigmented compound; “FR” indicates a flame-retardant formulation; and “P1” indicates a liner or primer option that controls unwinding and initial surface condition. Bonding occurs through silicone chain interdiffusion when the tape is stretched and pressed against itself. Because no adhesive is present, the fused layer retains elastomer recovery and does not exhibit adhesive ooze, drying, or plasticizer migration at temperatures within the manufacturer-rated operating range.

    In production wire-harness work, the material is applied at splice junctions, connector transitions, bus-bar bends, and irregular breakout areas where heat-shrink sleeving cannot be installed without mechanical disturbance. The tape is not a pressure-sensitive tape and should not be evaluated under adhesive peel methods. Its fusion mechanism is strain-dependent: the installer must elongate the tape during wrapping so that the silicone surfaces are brought into intimate contact under tensile stress. If the tape is wrapped without sufficient tension, the self-fusion reaction is incomplete and the outer edge can flag or delaminate during thermal cycling. On automatic tape heads, the unwind tension and dancer-arm drag are typically set to produce uniform elongation without necking the tape below its specified width. A half-lapped wrap with 50 % overlap gives two thickness layers over the substrate and is the minimum configuration used for electrical insulation; high-voltage applications typically require three or more half-lapped layers.

    How Does the 910-10BxxFR-P1 Differ from Adhesive-Backed Polyimide and PTFE Tapes?

    The primary difference is the absence of a discrete adhesive layer. Acrylic and silicone pressure-sensitive adhesives used on polyimide film tapes can transfer to conductor insulation, accumulate dust at the edge, and soften under sustained thermal load. Polyimide tape also has low elongation and does not conform well to tight three-dimensional splices. Skived PTFE tape offers broader chemical resistance but has negligible self-adhesion and must be retained by adhesive, overwrap, or heat. The 910-10BxxFR-P1 is installed primarily by controlled mechanical tension, and after fusion the tape becomes a homogeneous silicone elastomer mass at the overlap interface. That fusion mechanism eliminates a separate adhesive interface that could fail by cohesive shear under thermal expansion mismatch.

    A further difference is flame performance. The FR formulation in ARLON 910-10BxxFR-P1 is intended for systems where the insulation must self-extinguish after removal of the ignition source. The material is characterized under UL 510 as an insulating tape and under UL 94 for flammability; for aerospace harness work, the final assembly is often evaluated to FAR 25.853(a) 60-second vertical burn requirements. Adhesive-backed polyimide tapes may meet similar flame ratings only in specific adhesive constructions, and skived PTFE tapes can exhibit variable flame performance depending on filler content and thickness.

    The comparison also extends to operational stress. Silicone elastomer in the 910 series retains flexibility below -40 °C and does not appreciably stiffen at typical underhood or nacelle temperatures. Acrylic-adhesive systems often lose peel strength below -20 °C, while PTFE tapes can develop cold-flow under compressive clamp load. The self-fused silicone layer is therefore specified where the insulation must survive repeated thermal excursions without edge lifting.

    Specification Set and Batch Acceptance Methodology

    The table below lists representative design values from manufacturer technical data for the 910 series. The values are not substitutes for lot-specific certificates of conformance. Because the Bxx color-fill variable can shift elongation and dielectric strength slightly, qualification should be conducted on the exact compound supplied to the manufacturing site.

    PropertyTest methodNominal value
    Nominal thicknessASTM D3740.25 mm (±0.038 mm)
    Tensile strengthASTM D6386.9 MPa
    Elongation at breakASTM D638400 %
    Dielectric strengthASTM D14915.7 kV/mm
    Volume resistivityASTM D2571 × 10^15 Ω·cm
    Continuous operating rangeManufacturer thermal classification-54 °C to 180 °C
    Flame ratingUL 94V-0 at 0.25 mm thickness
    Fusion time at 23 °CManufacturer application method24 h to 72 h depending on wrap tension

    Published data for the specific Bxx custom-color derivatives is limited; therefore, the electrical acceptance of a production lot should reference the manufacturer’s certificate of conformance rather than generic 910 series datasheets. In batch acceptance, measure thickness under ASTM D374, dielectric strength under ASTM D149, and fusion integrity by unwrapping a test splice after 24 h. Interlaminar separation at the overlap indicates insufficient elongation during application, surface contamination, or lot-level variation in the self-fusing surface.

    Dielectric performance is layer-dependent. A single fused layer at 0.25 mm nominal thickness with a dielectric strength of 15.7 kV/mm yields a theoretical breakdown above 3.9 kV under laboratory conditions. Practical circuit insulation does not rely on this single-layer value; the accepted industrial practice is to calculate the required number of half-lapped layers from the working voltage, creepage distance, and environmental overvoltage category under the relevant equipment standard.

    Surface preparation must remove silicone oils, plasticizer residues, cutting fluids, and finger oils. Wipe the substrate with isopropyl alcohol or naphtha and allow the surface to dry before wrapping. Condensation at relative humidity above 60 % should be removed with dry low-lint wipes before application. Contamination at the fusion interface is the most frequent cause of edge flagging on production lines. Do not handle the tape with bare hands; nitrile gloves are preferred because latex gloves may transfer sulfur-bearing accelerators that can interfere with interfacial fusion.

    Storage limits should be observed. The roll should be kept in the original packaging below 35 °C and below 50 % relative humidity, away from direct sunlight, ultraviolet sources, and ozone-generating equipment. Partially used rolls should be sealed against dust and not kinked. If the tape has been stored below 10 °C, it should be allowed to equilibrate to 20 °C to 25 °C before application to restore handling elongation.

    When the FR-P1 Suffix Is Specified for Aerospace Harness Applications

    The FR-P1 variant is typically called out when the insulation must satisfy flammability requirements in airframe wiring and when the substrate cannot tolerate the thermal load of heat-shrink recovery. In those applications, the tape is wrapped over splices that have been crimped, soldered, or ultrasonically welded. The wrapped splice is then overbraided with aramid or polyester lacing, or covered with a heat-shrink boot only when additional abrasion resistance is required. Because the tape has no adhesive, it does not contribute to the combustible mass of a splice in the same way as an acrylic transfer film. Flame qualification is still performed at the assembly level, because the lacing, conductor insulation, and substrate geometry influence the burn path.

    A production-line failure mode observed with automatic wrapping equipment is non-uniform elongation when the tape roll is not braked consistently. If the unwind tension spikes, the tape necks down and the overlap becomes irregular. The resulting wrapped splice may pass visual inspection but fails fusion pull tests after thermal cycling. Tension-control settings should therefore be recorded for each roll lot, and the wrap head should be calibrated at the start of each shift. For manual wrapping, a constant pull without jerking is required; the installer should overlap by 50 % to 75 % of the tape width and finish with at least two full overwrap passes to prevent edge lifting.

    The P1 liner or primer option should not be viewed as an adhesion promoter in the pressure-sensitive sense. If the suffix denotes a primer, it is intended to modify the initial surface condition, not to replace mechanical elongation. If it denotes a liner, the liner must be removed cleanly at the start of each wrap without tearing the silicone film. A torn edge propagates under tension and creates a stress riser that can initiate splitting during thermal cycling. Operators should inspect the roll edge under low magnification after liner removal and reject rolls with edge nicks greater than 0.5 mm.

    The tape is not recommended for continuous immersion in ketones, esters, chlorinated solvents, or fuels containing high aromatic fractions. Silicone elastomers can swell in contact with certain hydrocarbon fluids, and swelling at the fused interface can reduce insulation registration. The tape should not be used as the sole insulation over live conductors above the voltage class established by the equipment standard, and it should not be applied directly over uncured silicone RTV that is releasing acetic acid or amine catalyst by-products. Those species can inhibit interdiffusion at the fusion interface and leave the wrap susceptible to delamination.

    In contrast to EPR self-amalgamating tapes, the silicone chemistry of the 910 series offers a wider thermal envelope and better resistance to ozone and corona at low pressure. In contrast to heat-shrink, the tape can be installed on fully assembled harnesses without a heat source and can be removed before fusion by unwrapping if rework is required. After full fusion, rework is mechanical: the fused mass is cut away and the conductor insulation inspected for surface damage. This rework behavior differs from adhesive tapes, which may leave residue that requires solvent cleaning before the splice can be re-insulated.

    The comparative profile is summarized in the table below. The table is not a qualification matrix; it is a design-selection aid based on installation mechanism and field-observable failure mode.

    Material systemBonding mechanismTemperature classFlame performanceInstallation requirement
    ARLON 910-10BxxFR-P1Silicone chain interdiffusion; no adhesive-54 °C to 180 °CUL 94 V-0 on 0.25 mm thicknessControlled mechanical tension; no heat
    Acrylic-adhesive polyimide film tapePressure-sensitive adhesive transfer-40 °C to 180 °CGrade-dependentPressure; no heat
    Skived PTFE tapeNone; requires adhesive or mechanical retention-70 °C to 260 °CGrade-dependentOften requires adhesive or heat
    EPR self-amalgamating tapeEthylene-propylene chain interdiffusion-40 °C to 105 °CHalogen-free grade-dependentControlled mechanical tension; no heat

    For applications above 180 °C or where continuous exposure to aggressive petroleum-based fluids is expected, the 910-10BxxFR-P1 should be evaluated against alternative insulation systems because silicone swell, not flame performance, becomes the governing limitation. Where the harness is subject to repeated torsional flexing, the fused tape should be tested under the actual bend radius and cycle count of the assembly; published data for this specific configuration is limited for dynamic flex-fatigue applications.

    Top