Polyplastics Duranex Unreinforced Pbt 2002

Polyplastics DURANEX® Unreinforced PBT 2002

    • Product Name: Polyplastics DURANEX® Unreinforced PBT 2002
    • Factroy Site: Yinchuan, Ningxia, China
    • Price Inquiry: sales8@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 535233
    Density 1.31 g/cm³
    Water Absorption 0.2 %
    Mold Shrinkage 1.5-2.0 %
    Tensile Strength 55 MPa
    Tensile Elongation At Break 50 %
    Flexural Modulus 2500 MPa
    Flexural Strength 85 MPa
    Charpy Notched Impact Strength 3 kJ/m²
    Rockwell Hardness M 78
    Heat Deflection Temperature At 1 82 Mpa 65 °C
    Heat Deflection Temperature At 0 45 Mpa 150 °C
    Melting Point 225 °C
    Coefficient Of Linear Thermal Expansion 7×10^-5 /K
    Volume Resistivity 1×10^16 Ω·cm
    Dielectric Constant At 1 Mhz 3.3
    Dissipation Factor At 1 Mhz 0.002
    Dielectric Breakdown Strength 20 kV/mm
    Arc Resistance 120 s
    Ul94 Flammability Rating HB

    As an accredited Polyplastics DURANEX® Unreinforced PBT 2002 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Packaged as 25 kg moisture-resistant bags, palletized in multilayer industrial packaging for safe handling and shipment of Polyplastics DURANEX® Unreinforced PBT 2002.
    Container Loading (20′ FCL) 20′ FCL container loading: palletized 25 kg bags of Polyplastics DURANEX® Unreinforced PBT 2002, shrink-wrapped and secured for transport.
    Shipping Polyplastics DURANEX® Unreinforced PBT 2002 is shipped as non-hazardous thermoplastic resin pellets in sealed, moisture-barrier packaging on pallets. Protect from heat, moisture, and contamination. No UN number, proper shipping name, hazard class, or packing group is normally assigned; comply with the manufacturer’s SDS and applicable transport regulations.
    Storage Store Polyplastics DURANEX® Unreinforced PBT 2002 in a cool, dry, well-ventilated area, away from direct sunlight, heat, ignition sources, and moisture. Keep in original sealed packaging until use; prevent exposure to humid air and contaminants. Avoid prolonged storage near oxidizing agents. Follow the manufacturer’s SDS and local regulations for safe handling and storage.
    Shelf Life Shelf life is typically 24 months from date of manufacture when stored in original unopened packaging under dry, cool conditions.
    Free Quote

    Competitive Polyplastics DURANEX® Unreinforced PBT 2002 prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Polyplastics DURANEX® 2002 is an unreinforced polybutylene terephthalate (PBT) injection molding grade supplied by Polyplastics Co., Ltd. The material is classified as a medium-flow, unfilled thermoplastic polyester for general-purpose electrical, mechanical, and automotive components. Unlike glass-fiber-reinforced or mineral-filled DURANEX grades, the 2002 designation carries no fibrous or particulate reinforcement. Published datasheet values for the grade include a density of 1.31 g/cm³ under ISO 1183, a melt volume-flow rate of approximately 27 cm³/10 min at 250°C and 2.16 kg under ISO 1133-1:2022, a tensile strength of approximately 55 MPa under ISO 527-1/-2, and a flexural modulus of approximately 2,500 MPa under ISO 178. The grade is selected where lower stiffness, higher elongation, low abrasiveness, and good electrical insulation are required, but it is not a direct substitute for impact-modified or hydrolysis-stabilized PBT formulations in hot-water or high-impact service.

    PropertyTest methodTypical value
    DensityISO 11831.31 g/cm³
    Tensile strengthISO 527-1/-255 MPa
    Flexural modulusISO 1782,500 MPa
    Flexural strengthISO 17880 MPa
    Charpy notched impact strengthISO 179/1eA3.0 kJ/m²
    Heat deflection temperatureISO 75-1/-260°C at 1.8 MPa
    Melt volume-flow rateISO 1133-1:202227 cm³/10 min at 250°C/2.16 kg
    Water absorptionISO 620.1% for 24 h

    DURANEX 2002 Exhibits a Melt Crystallization Profile That Demands Predictive Barrel Profiling

    DURANEX 2002 is characterized by a crystallization temperature usually between 190°C and 210°C as measured by ISO 11357-3 differential scanning calorimetry at 10 K/min cooling. The crystallization half-time is sufficiently short that thin-walled parts reach ejection rigidity before full packing compensation is complete; molders often observe sink marks and gate blush when the holding pressure profile is not matched to the solidification front. Barrel temperature profiles in production typically run from 230°C at the rear zone to 250°C at the nozzle, while the melt should not exceed 260°C because unreinforced PBT undergoes thermal degradation that shifts molecular weight and increases melt flow rate beyond the release window. Residence time at melt temperature should be kept below 5 min; extended holding of 10 min or more can lead to yellowing, acetaldehyde-like odor, and charred deposits on the screw. Single-flight screws with compression ratios between 2.5:1 and 3.0:1 and short feed sections are preferred over deep-cut mixing screws that generate frictional shear in the melt. Hot-runner manifolds should be externally heated with independent tip temperature control at 240°C to 250°C; internally heated runners can create local hot spots above 280°C and cause material degradation at the gate interface. Mold cooling circuits should maintain a cavity surface temperature of 40°C to 80°C; below 40°C, dimensional variability and visible flow-line defects increase.

    Where load-bearing gears, cams, or structural brackets are specified, the substitution of DURANEX 2002 for a 30% glass-fiber-filled PBT grade changes the failure mode from creep-limited flexural deformation to impact-limited crack initiation. Unreinforced PBT has a flexural modulus of approximately 2,500 MPa, whereas the same series with 30% glass fiber can exceed 8,000 MPa under ISO 178; the lower modulus of the unreinforced grade allows greater deflection before fracture but reduces bearing load capacity. This does not make DURANEX 2002 unsuitable for gears; it means design calculations must use the lower modulus and the unfilled material’s higher coefficient of linear thermal expansion, which is generally reported in the range 7×10−5 K−1 to 10×10−5 K−1 between 23°C and 55°C under ISO 11359-2. In unlubricated sliding wear against steel, unreinforced PBT typically generates lower counterface abrasion than glass-filled PBT because the glass fibers act as a hard third body; however, the specific wear rate depends on contact pressure, surface roughness, and lubricant regime, and published data for this specific grade is limited. The practical consequence is that DURANEX 2002 is selected for small gears, rollers, and sliding blocks where conformability and low noise are valued over maximum load capacity.

    What Testing Standards Govern the Electrical and Thermal Classification of DURANEX 2002?

    Electrical insulating components molded from DURANEX 2002 are usually qualified under IEC 60243-1 for dielectric strength, IEC 60093 for volume resistivity, and IEC 60112 for comparative tracking index. Typical values for unreinforced PBT include a dielectric strength of 16 kV/mm to 20 kV/mm at 1.0 mm thickness, a volume resistivity above 1014 Ω·cm, and a comparative tracking index above 400 V. DURANEX 2002 is not a flame-retardant grade; its UL 94 classification at 0.8 mm and 1.6 mm is typically HB, not V-0. Applications requiring glow-wire compliance under IEC 60695-2-11 for unattended appliance current-carrying parts may require a flame-retardant DURANEX grade instead. Heat deflection temperature under 1.8 MPa is typically near 60°C under ISO 75-1/-2, and the Vicat softening temperature is generally near 215°C under ISO 306 method B50. Continuous use under mechanical load should be limited to service temperatures below approximately 100°C in air; above 120°C, oxidation embrittlement accelerates and tensile strength declines significantly. The thermal classification under IEC 60216 depends on the activation energy of oxidative degradation, which is not published for DURANEX 2002 in all manufacturers’ documentation; end users should request thermal endurance data from Polyplastics when the application exceeds 80°C continuous service.

    Pre-drying of DURANEX 2002 is mandatory before molding when the moisture content exceeds 0.02%; saturated material can contain 0.4% to 0.5% water under ISO 62 after prolonged humid exposure. A desiccant-bed dryer with a dew point of −30°C or lower maintained at 120°C for 3 h to 5 h is the standard preparation; air-dryers that do not reduce dew point below −20°C are ineffective at removing the final 0.02% of moisture. In production environments above 60% relative humidity, regrind should be blended at no more than 25% by weight unless the regrind has been re-dried separately. Hydrolysis is the dominant long-term failure mode: hot water and steam degrade the ester bonds in PBT, reducing molecular weight and causing surface cracks at gate and weld regions. Continuous immersion in water above 40°C is generally not recommended for unreinforced DURANEX 2002 unless the part is unstressed and periodic inspection is accepted. In 60°C water, tensile strength retention may fall below 50% after several hundred hours depending on wall thickness and end-group concentration; specific published data for this grade is limited, so qualification under the end-use fluid and temperature is required.

    When Hot-Runner Molding with Unreinforced PBT Introduces Gate-Freeze and Drool Instability

    Hot-runner tooling with valve-gate control is recommended over thermal sprue-gating for DURANEX 2002 when cycle times exceed 20 s. Unreinforced PBT has a narrow freeze-off window; the gate diameter must be at least 70% of the nominal wall thickness to avoid premature gate freeze before packing. Drooling from open hot tips is controlled by maintaining the tip temperature below 240°C and by using sprue break or suck-back with a screw decompression distance of 2 mm to 5 mm. The material’s low melt viscosity means that back pressure should be set between 3 MPa and 7 MPa; higher back pressure increases melt residence time and may initiate thermal degradation. Screw speed should be adjusted to provide a plasticating time between 50% and 70% of the cooling time; screw speeds above 250 rpm on 35 mm to 40 mm screw diameters can raise melt temperature above the setpoint due to shear heating. Cavity filling analysis should target a flow-front velocity below 300 mm/s to avoid jetting and surface defects; above 500 mm/s, unreinforced PBT can exhibit flow marks and weld-line weakening. In a 1,000 kN toggle clamp machine molding a multi-cavity connector, the holding pressure is typically set between 30 MPa and 50 MPa hydraulic pressure, and transfer from injection to holding pressure should occur at 95% to 98% of full part volume. Cooling time for a 2 mm wall is often 10 s to 15 s with a mold temperature of 60°C; cycle time optimization below that range requires in-process dimensional checks because the part can continue to crystallize after demolding.

    Processing parameterRecommended range or setpoint
    Drying temperature120°C
    Drying time3 h to 5 h
    Dryer dew point≤ −30°C
    Barrel rear temperature230°C
    Barrel nozzle temperature250°C
    Maximum melt temperature260°C
    Mold temperature40°C to 80°C
    Back pressure3 MPa to 7 MPa
    Screw decompression2 mm to 5 mm
    Hot-runner tip temperature240°C to 250°C
    Gate diameter≥ 70% of wall thickness

    Comparison Between Unreinforced 2002 and Glass-Filled PBT in Bearing and Gear Applications

    Bearing and gear applications expose a molded part to cyclic loads, sliding friction, and dimensional constraints. DURANEX 2002 is selected when the design can tolerate the lower flexural modulus of 2,500 MPa in exchange for improved elongation and reduced counterface wear. In contrast, glass-fiber-reinforced PBT grades are used where the gear tooth root stress requires a flexural modulus above 6,000 MPa and where axial growth from thermal expansion must be minimized. The unreinforced grade’s coefficient of linear thermal expansion is roughly three times higher than that of a 30% glass-filled PBT; this difference affects gear meshing clearance at service temperatures above 50°C. Mold shrinkage for DURANEX 2002 is typically 1.5% to 2.0% in flow direction and 1.5% to 2.0% transverse, whereas glass-filled PBT shrinks below 0.5% and exhibits anisotropic shrinkage. Cavity dimensions for unfilled 2002 must therefore be prototyped before multi-cavity tool production because shrinkage varies with gate location, packing pressure, and wall thickness. DURANEX 2002 offers lower melt viscosity than glass-reinforced grades, permitting filling of thin-wall connectors at lower injection pressure, but the absence of glass fibers also reduces heat distortion resistance and increases the risk of creep under continuous load. In gears, tooth deflections are calculated with the lower modulus and the unfilled material’s tensile creep modulus; published creep modulus data for this specific grade is limited, so design calculations should use a safety factor of at least 1.5 on tooth bending stress.

    In electrical connector and relay applications, DURANEX 2002 is used for housings, terminal blocks, and switching components that require dimensional repeatability in thin sections. Chemical resistance of the material is similar to that of other unmodified PBT polyesters. The material withstands motor oil, gasoline, diesel fuel, lithium-salt greases, and many alcohols at room temperature, but it is incompatible with concentrated sulfuric acid, nitric acid, and strong alkaline solutions at elevated temperatures. Resistance to chlorinated solvents is poor; exposure to dichloromethane or trichloroethylene causes stress cracking or swelling. Brake fluid and hot ethylene glycol can degrade the material over time. DURANEX 2002 is not recommended for continuous contact with boiling water or high-pressure steam. The effect of any chemical environment must be tested under ISO 175 or ASTM D543 using the exact part geometry and molded-in stress state. Mold venting depths should be kept below 0.02 mm to prevent flash while allowing air evacuation in high-flow multi-cavity tools.

    Top