| HS Code | 604093 |
| Reinforcement | Unreinforced |
| Density | 1.31 g/cm3 |
| Waterabsorption 24h | 0.08 % |
| Moldingshrinkage | 1.5-2.0 % |
| Tensilestrength | 55 MPa |
| Tensileelongation | 50 % |
| Flexuralstrength | 85 MPa |
| Flexuralmodulus | 2400 MPa |
| Charpyimpactstrength Notched | 4 kJ/m2 |
| Rockwellhardness | M78 |
| Deflectiontemperature 1 82mpa | 65 °C |
| Deflectiontemperature 0 45mpa | 150 °C |
| Meltingpoint | 224 °C |
| Coefficientoflinearexpansion | 7-9 x10^-5 /K |
| Volumeresistivity | 1 x10^16 Ω·cm |
| Dielectricstrength | 20 kV/mm |
| Dielectricconstant 1mhz | 3.2 |
| Dissipationfactor 1mhz | 0.002 |
| Arcresistance | 120 s |
| Flammability Ul94 | HB |
| Melttemperature | 240-260 °C |
| Moldtemperature | 60-80 °C |
| Dryingtemperature | 120 °C |
| Dryingtime | 3-4 h |
As an accredited Polyplastics DURANEX® Unreinforced PBT 2000 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Polyplastics DURANEX® Unreinforced PBT 2000 is packaged in 25 kg moisture-barrier bags, palletized for industrial handling and storage. |
| Container Loading (20′ FCL) | 20′ FCL container loaded with palletized 25 kg bags of Polyplastics DURANEX® Unreinforced PBT 2000, shrink-wrapped and secured for ocean shipment. |
| Shipping | Polyplastics DURANEX® Unreinforced PBT 2000 is typically shipped as non-hazardous thermoplastic pellets in moisture-barrier bags or boxes. It is generally not regulated for transport under DOT/IMDG/IATA in normal packaging. Store cool, dry, away from moisture and direct sunlight; use standard freight. Verify current SDS before shipment. |
| Storage | Store in a cool, dry, well-ventilated area away from direct sunlight, heat, ignition sources, and moisture. Keep containers tightly closed and avoid contamination with dust, oils, or other chemicals. Do not store near strong oxidizers. Use proper stacking to prevent package damage, and follow the manufacturer’s SDS and local regulations. |
| Shelf Life | No fixed shelf life is specified; store in original unopened packaging in a cool, dry place, protected from moisture and direct sunlight. |
Competitive Polyplastics DURANEX® Unreinforced PBT 2000 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Polyplastics DURANEX® 2000 is an unfilled polybutylene terephthalate grade for injection moulding. The resin is a semicrystalline polyester produced by polycondensation of 1,4-butanediol and dimethyl terephthalate; its melting range is commonly reported between 220 °C and 225 °C. Because no glass fibre, mineral filler, or flame-retardant additive is present, the melt viscosity is lower than that of reinforced DURANEX grades, and the moulded surface is free of fibre-induced roughness. The grade is classified as general purpose and is typically recognised as UL 94 HB; the exact rating is thickness-dependent and must be confirmed from the supplier yellow card. DURANEX 2000 is not formulated for load-bearing structural applications where heat deflection temperature under load above 60 °C is required.
Typical property values are summarised in Table 1. Data are obtained on dry-as-moulded specimens conditioned according to ISO 291 at 23 °C and 50% relative humidity. Published values should be treated as representative lot averages, not guaranteed minima, because polymerisation conditions, additive masterbatch, and part geometry influence final performance.
Table 1. Typical dry-as-moulded property profile for DURANEX 2000.
| Property | Test method | Typical value |
|---|---|---|
| Density | ISO 1183-1 | 1.31 g/cm³ |
| Tensile stress at yield | ISO 527-1/-2 | 55 MPa |
| Flexural modulus | ISO 178 | 2.4 GPa |
| Flexural strength | ISO 178 | 80 MPa |
| Charpy notched impact strength | ISO 179-1/1eA | 4.0 kJ/m² |
| Heat deflection temperature at 1.80 MPa | ISO 75-1/-2 | 60 °C |
| Heat deflection temperature at 0.45 MPa | ISO 75-1/-2 | 150 °C |
| Mould shrinkage | ISO 294-4 | 1.5–2.5% |
| Water absorption, 23 °C, 24 h | ISO 62 | 0.1% |
| Volume resistivity | IEC 60093 | 1015 Ω·cm |
| Dielectric strength | IEC 60243-1 | 17 kV/mm |
In thin-wall electronic connectors with wall stock between 0.4 mm and 0.8 mm, DURANEX 2000 is processed at melt temperatures of 240–250 °C and injection pressures from 80 MPa to 120 MPa. The melt volume-flow rate, typically in the range of 20–30 cm³/10 min at 250 °C under 2.16 kg according to ISO 1133-1, permits filling of high-flow-length parts without excessive gate freeze-off. The unfilled system also retains ductility at knit lines in multi-gated connector housings. However, exposure to soldering processes above the 60 °C heat deflection temperature under load can produce dimensional movement; reflow-solderable connectors generally require a higher-heat reinforced PBT or another polymer class.
Reinforcement changes the load-transfer mechanism. In a common 30 wt% glass-fibre reinforced PBT grade, tensile stress at yield is approximately 130 MPa, flexural modulus is approximately 9.5 GPa, and heat deflection temperature at 1.80 MPa rises to approximately 200 °C under ISO 75-1/-2. DURANEX 2000 exhibits approximately 55 MPa tensile stress at yield, 2.4 GPa flexural modulus, and 60 °C heat deflection temperature. Table 2 compares typical values.
| Property | DURANEX 2000 unreinforced PBT | 30 wt% glass-fibre reinforced PBT |
|---|---|---|
| Density | 1.31 g/cm³ | 1.53 g/cm³ |
| Tensile stress at yield | 55 MPa | 130 MPa |
| Flexural modulus | 2.4 GPa | 9.5 GPa |
| Charpy notched impact strength | 4.0 kJ/m² | 8.0 kJ/m² |
| Heat deflection temperature at 1.80 MPa | 60 °C | 200 °C |
| Mould shrinkage, flow direction | 1.5–2.5% | 0.2–0.9% |
The mechanical difference does not always favour the filled material. Glass fibre introduces orientation-dependent shrinkage; flow-direction shrinkage is lower than transverse shrinkage, and differential shrinkage in flat parts can produce warpage after ejection. Unreinforced DURANEX 2000 has isotropic mould shrinkage in the range of 1.5–2.5% under ISO 294-4, which is advantageous for flat, close-tolerance parts when gating produces non-uniform fibre orientation. In addition, glass-filled PBT accelerates screw, barrel, and check-ring wear on standard injection units; DURANEX 2000 can be processed on hardened or nitrided screws without the same abrasive load, although lower melt viscosity may increase screw slip in the feed zone if barrel temperature is too low.
In switch components and coil forms, the unfilled grade provides a comparative tracking index typically above 400 V under IEC 60112 when dry and tested on 3 mm plaques. Dielectric strength of 17 kV/mm under IEC 60243-1 supports electrical clearance design in dry indoor service. However, DURANEX 2000 is not a hydrolysis-resistant grade, and its dielectric performance declines when the material retains water from humid storage or condensation cycling. At service temperatures above the 60 °C heat deflection temperature, spring-loaded retention features may lose clamping force through creep; in those geometries a reinforced PBT or a higher-heat thermoplastic is required.
Pre-drying is mandatory when the storage relative humidity exceeds 60%. Desiccant drying at 120–130 °C for 4–6 h is recommended, with a drying air dew point of −30 °C or lower. Target residual moisture is below 0.02 wt%. In production-scale practice, hopper dryers without dew-point control frequently fail to reach this target at 120 °C; the result is surface splay, gas streaks, and reduced tensile strength in thin-wall parts. Batch-to-batch variation in melt volume-flow rate may be observed within a range of roughly ±3 cm³/10 min, and the injection profile should be adjusted when regrind or masterbatch changes the effective viscosity.
Typical barrel settings begin at 230 °C in the rear zone, increase to 240–245 °C in the centre, and reach 250 °C at the front zone; nozzle temperature is usually 245 °C. Melt temperature is controlled between 230 °C and 250 °C. Mould temperature is maintained between 40 °C and 80 °C. Lower mould temperatures shorten cycle time but increase frozen-in stress and dimensional change after ejection. Higher mould temperatures of 70–80 °C reduce post-moulding shrinkage drift and improve surface appearance at the expense of longer cycle time. Back pressure is held at 5–10 MPa, and screw rotation speed on a 40 mm injection screw is typically 50–100 min⁻¹. Excessive shear heating above 260 °C or melt residence time over 8 min can increase melt flow rate through chain scission before visible discolouration occurs.
On a 35 mm co-rotating twin-screw extruder with L/D 36 and vacuum venting at −0.08 MPa, extrusion of DURANEX 2000 at a melt temperature of 245 °C is used to maintain strand stability. If residual moisture exceeds 0.02 wt%, vent flow and strand porosity appear even when vacuum is maintained, indicating hydrolysis in the melt. For injection moulding, a shot capacity below 50% of barrel capacity is recommended to limit residence time; at cycle times above 40 s, throughput should be matched to the plastication capacity of the screw to avoid stale melt in the compression zone.
PBT is vulnerable to hydrolytic chain scission in the melt and in hot aqueous service. The ester linkage reacts with water to form carboxylic acid and alcohol end groups; the acid end groups catalyse further hydrolysis, producing an autocatalytic molecular-weight loss. In a hot-runner system with local wall temperatures above 260 °C, residual moisture concentrates at the melt boundary and generates pinholes, silver streaks, and viscosity loss. The degradation rate follows an Arrhenius-type temperature dependence, with a practical rule that residence time must be shortened by roughly half for every 10 °C increase above 250 °C. Published data for DURANEX 2000 at 260 °C and 8 min residence are limited, but lot acceptance tests commonly use melt volume-flow rate shift under ISO 1133-1 to detect degradation before tensile impact loss is measured.
Hot-runner systems for DURANEX 2000 should be configured with externally heated manifolds, minimum internal dead zones, and thermocouples placed no more than 15 mm from the gate. Gate freeze time is short because of the unfilled fast-crystallising nature of the PBT; valve-gate systems are preferred over open hot tips where gate stringing is unacceptable. At 85 °C and 85% relative humidity, hydrolysis in moulded parts accelerates; tensile property retention should be validated by immersion testing under ISO 62 followed by ISO 527-1/-2. Parts destined for continuous hot-water contact above 60 °C are usually specified in hydrolysis-resistant or glass-filled PBT grades because DURANEX 2000 loses toughness as molecular weight declines.
Chemical compatibility boundaries include strong acids, alkaline cleaners, and amine-containing additives. Alkaline media neutralise acid end groups and accelerate ester hydrolysis; amines can attack the ester linkage directly. Chlorinated hydrocarbons and aromatic solvents may induce environmental stress cracking in stressed mouldings. When colourants or additive masterbatches are used, they must be dried with the base resin and must not contain moisture-liberating carriers. DURANEX 2000 is not formulated for repeated steam sterilisation or for direct contact with boiling water without validation of part function over the intended service life.