| HS Code | 756836 |
| Product | Polyplastics DURANEX® PBT+GF15% 3105 |
| Polymer Type | Polybutylene terephthalate (PBT) |
| Reinforcement | 15% glass fiber |
| Density | 1.41 g/cm³ (ISO 1183) |
| Water Absorption 24 H 23 C | 0.2% (ISO 62) |
| Mold Shrinkage Md | 0.3–0.5% (ISO 294-4) |
| Tensile Strength | 100 MPa (ISO 527-1/-2) |
| Tensile Elongation At Break | 3% (ISO 527-1/-2) |
| Flexural Modulus | 5500 MPa (ISO 178) |
| Flexural Strength | 160 MPa (ISO 178) |
| Charpy Notched Impact Strength 23 C | 4 kJ/m² (ISO 179/1eA) |
| Heat Deflection Temperature 1 8 Mpa | 200°C (ISO 75-1/-2) |
| Melting Point | 224°C (ISO 11357-3) |
| Volume Resistivity | 1×10^16 Ω·cm (IEC 62631-3-1) |
| Dielectric Strength | 20 kV/mm (IEC 60243-1) |
| Flammability Rating | UL94 HB |
As an accredited Polyplastics DURANEX® PBT+GF15% 3105 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Polyplastics DURANEX® PBT+GF15% 3105 is supplied in sealed 25 kg moisture-proof bags, palletized in 1,000 kg lots for industrial handling. |
| Container Loading (20′ FCL) | 20′ FCL container loading for Polyplastics DURANEX® PBT+GF15% 3105, securely packed and stowed for ocean shipment. |
| Shipping | Polyplastics DURANEX® PBT+GF15% 3105 is shipped as moisture-sensitive thermoplastic resin pellets in sealed foil-lined bags or cartons, palletized and kept dry. It is not classified as dangerous goods for transport; avoid heat, sunlight, and humidity. Follow supplier packaging, labeling, and storage instructions. |
| Storage | Store DURANEX® PBT+GF15% 3105 in a cool, dry, well-ventilated area, protected from direct sunlight, moisture, heat, and ignition sources. Keep original bags sealed and pallets off the floor; avoid dust generation and static buildup. Use first-in, first-out stock rotation. Store away from incompatible chemicals and follow local regulations and safety data sheet requirements. |
| Shelf Life | Typically 2 years from manufacture when stored unopened in a cool, dry place, protected from moisture, heat, and direct sunlight. |
Competitive Polyplastics DURANEX® PBT+GF15% 3105 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Polyplastics DURANEX® PBT+GF15% 3105 is an injection-molding grade of polybutylene terephthalate reinforced with 15% glass fiber by mass. The material is supplied as pellets for reciprocating-screw injection molding machines with L/D ratios of 20:1 to 24:1. Because the glass fiber content is fixed at 15% by ISO 3451-1 ash analysis, the mechanical property profile is intermediate between unfilled DURANEX 2002 PBT and DURANEX 3300 PBT-GF30 within the DURANEX PBT series. The grade is used where heat resistance, electrical insulation, and reduced mold shrinkage relative to unfilled PBT are required without the higher melt viscosity and pronounced anisotropic shrinkage of a 30% glass-filled grade. Published datasheets list representative values rather than specification limits; lot-to-lot variation in fiber length distribution after plastication can shift tensile elongation, and published data for this specific configuration is limited.
Table 1 compiles representative single-point values determined from dry-as-molded ISO 3167 type A specimens. All values are generated after conditioning at 23 °C and 50% relative humidity according to ISO 291:2008. Tensile strength and strain are measured per ISO 527-1:2012 and ISO 527-2:2012 on type 1A specimens, with modulus determined at 1 mm/min and strength at 5 mm/min. Flexural properties are measured at 2 mm/min per ISO 178:2019. Charpy notched impact strength is obtained using edgewise impact on type 1 specimens per ISO 179-1:2010/1eA. Heat deflection temperature is measured by the HDT/A method at 1.8 MPa flexural stress per ISO 75-1:2013 and ISO 75-2:2013. Water absorption is determined after 24 h immersion at 23 °C per ISO 62:2008.
| Property | Test standard | Unit | Representative value |
|---|---|---|---|
| Density | ISO 1183-1:2019 | g/cm³ | 1.41 |
| Tensile strength at break | ISO 527-2 | MPa | 100 |
| Tensile strain at break | ISO 527-2 | % | 2.5 |
| Flexural strength | ISO 178:2019 | MPa | 160 |
| Flexural modulus | ISO 178:2019 | MPa | 5,300 |
| Charpy notched impact strength, 23 °C | ISO 179-1/1eA | kJ/m² | 4.5 |
| Heat deflection temperature, HDT/A | ISO 75-1/-2 | °C | 200 |
| Water absorption, 24 h | ISO 62:2008 | % | 0.2 |
| Mold shrinkage, flow direction | ISO 294-4 | % | 0.4–0.8 |
The 15% glass fiber content places DURANEX 3105 in the lower half of the stiffness range for the DURANEX fiber-reinforced portfolio. In tension, the material typically exhibits a linear stress-strain response with limited post-yield elongation because the glass fibers restrict ductile flow. At the stated fiber content, the tensile modulus remains below that of PBT-GF30 grades, which limits gate-area stress concentration but also reduces load-bearing cross-sections for snap-fit arms under repeated flexure. For snap-fit designs, maximum outer-fiber strain should be kept below 1.5% unless application-specific fatigue testing confirms otherwise.
Pre-drying of DURANEX 3105 is mandatory when pellet moisture has exceeded 0.02% by Karl Fischer titration per ISO 15512:2019. Hydrolytic degradation in PBT is autocatalytic; moisture attack at ester linkages reduces molecular weight and causes a measurable drop in melt viscosity and notched impact strength. Desiccant hopper dryers with dew point below −30 °C and air flow of 0.5–1.0 m³/h per kg/h throughput are used. Drying at 120 °C for 4–6 h is typical. At relative humidity above 60%, pellets exposed for more than 2 h should be re-dried or kept under heated hopper covers. Melt temperature should be held at 250–270 °C, measured by air-shot pyrometry, and mold temperature should be maintained at 60–100 °C. Barrel zones from rear to nozzle are typically set flat or with a reverse profile to prevent fiber fracture in the compression zone. Screw speed should be limited to 8–12 m/min peripheral speed, equivalent to 100–200 min⁻¹ on a 50 mm screw, and back pressure should not exceed 2 MPa to control fiber length retention. Residence time above 270 °C should not exceed 10 min; longer residence can degrade tensile strength by more than 5% in molded specimens. Injection speed is set by the cavity pressure trace. A filling time of 0.5–1.5 s for wall sections below 2 mm avoids premature freeze-off without exceeding gate shear rates of 100,000 s⁻¹; tool-specific rheology verification is required.
For thin-wall connectors with nominal wall thickness 0.8–1.5 mm, differential flow- and cross-flow shrinkage is the primary source of warpage. DURANEX 3105, at 15% glass fiber, exhibits lower anisotropy than DURANEX 3300 GF30 because the lower fiber volume fraction reduces the magnitude of orientation-induced shrinkage difference between flow and transverse directions. Mold filling analysis with Moldflow or Moldex3D should apply residual stress and fiber orientation tensor data from injection molding simulation. Without simulation, edge-gated flat parts above 40 mm length can exhibit measured bow exceeding 0.3 mm when shrinkage difference between flow and cross-flow exceeds 0.1%. Tooling solutions include end-gated or fan-gated layouts, balanced melt delivery, and sequential valve-gate control where available. Mold temperature uniformity of ±5 °C across the cavity surface is maintained to reduce differential crystallization shrinkage.
Electrical enclosure and sensor housing applications use DURANEX 3105 where insulation and dimensional stability under intermittent temperature excursions are required. The grade is commonly cited for relay bases, bobbin components, miniature circuit breaker housings, and under-hood sensor brackets. In these applications, flammability classification is typically HB at 0.75 mm per UL 94; end-use certification remains component-specific. Volume resistivity after 24 h at 23 °C and 50% relative humidity is usually in the 1015 Ω·cm range per IEC 60093. Comparative tracking index is frequently reported at 250 V per IEC 60112, although test contamination and surface finish alter results. Because PBT retains low moisture absorption—approximately 0.2% at equilibrium per ISO 62—the dimensional change due to humidity is smaller than polyamide 66 alternatives, but post-molding shrinkage in hot atmospheres continues for 24–48 h at 80 °C as crystallinity advances.
Relative to unfilled DURANEX 2002, DURANEX 3105 provides a measurable reduction in mold shrinkage and thermal expansion. Glass fiber restricts isotropic contraction in the flow direction. Published comparative shrinkage values per ISO 294-4 for 60 mm × 60 mm × 2 mm plaques show mold shrinkage in the flow direction of 0.4–0.8% for 3105, whereas unfilled PBT typically falls in the 1.5–2.0% range. The coefficient of linear thermal expansion in flow direction is also lower—approximately 50 × 10−6 K−1 for 3105 compared with 90 × 10−6 K−1 for unfilled PBT between 23 °C and 80 °C by thermo-mechanical analysis. This difference matters for metal-insert molding and for overmolded contacts, where mismatched expansion produces stress cracking at the insert interface. The trade-off is lower elongation at break; unfilled PBT can exceed 20% tensile strain, while 3105 typically remains below 3%. For snap-fit latching features, the allowable undercut is therefore reduced, and a cantilever beam analysis should use the tensile modulus of 5,300 MPa rather than that of unfilled PBT.
Table 2 summarizes representative comparative values for DURANEX 3105, unfilled DURANEX 2002, and DURANEX 3300 PBT-GF30. Values are rounded from published single-point data and are not specification limits.
| Property | DURANEX 3105 PBT-GF15 | Unfilled DURANEX 2002 PBT | DURANEX 3300 PBT-GF30 |
|---|---|---|---|
| Density, g/cm³ | 1.41 | 1.31 | 1.52 |
| Tensile strength at break, MPa | 100 | 55 | 130 |
| Flexural modulus, MPa | 5,300 | 2,500 | 9,000 |
| HDT/A, °C | 200 | 155 | 205 |
| Charpy notched impact strength, 23 °C, kJ/m² | 4.5 | 4.0 | 6.0 |
Compared with DURANEX 3300 GF30, DURANEX 3105 demonstrates lower stiffness and lower notch impact strength but also lower melt viscosity and reduced warpage. The flexural modulus of 3105 is approximately 5,300 MPa, while 3300 is above 9,000 MPa; this lower modulus limits stress concentration at thin wall sections in overmolded connectors. The lower glass content also reduces equipment abrasion. Screw and barrel wear with 15% glass-fiber PBT is less than with 30% glass-fiber grades, but hard-chrome or bimetallic barrels are still recommended for continuous runs above 500,000 shots. Drying and melt temperature conditions are identical to other DURANEX PBT grades, but the processing window for surface appearance is wider than GF30 because lower fiber content reduces surface read-through. Gloss variation remains dependent on mold polish, gate freeze-off, and packing pressure.
DURANEX 3105 is resistant to many aliphatic hydrocarbons, dilute acids, and automotive fluids at ambient temperature. Strong alkaline solutions and prolonged exposure to hot water above 60 °C cause hydrolytic attack at ester linkages. Contact with amine-based additives or flame-retardant masterbatches containing free amines should be avoided because transesterification and rapid molecular-weight reduction occur during melt processing. When regrind is used, the maximum recommended addition is 20–30% by mass because repeated heat history shortens fiber length and reduces tensile strength. Regrind must be dried to the same moisture specification as virgin material. For applications requiring outdoor exposure, the product requires UV stabilization; unstabilized PBT may undergo surface chalking and loss of gloss after 1,000 h of Xenon arc exposure at 0.35 W/m² per ISO 4892-2 unless compounded with carbon black or hindered amine stabilizers.