| HS Code | 420813 |
| Polymer Type | MABS (Methyl Methacrylate Acrylonitrile Butadiene Styrene) |
| Density | 1.08 g/cm³ |
| Melt Mass Flow Rate | 10 g/10 min (220 °C/10 kg) |
| Tensile Modulus | 2100 MPa |
| Tensile Strength | 42 MPa |
| Elongation At Break | 25% |
| Flexural Modulus | 2100 MPa |
| Charpy Notched Impact Strength | 12 kJ/m² |
| Heat Deflection Temperature | 75 °C (1.8 MPa) |
| Vicat Softening Temperature | 92 °C |
| Mold Shrinkage | 0.4–0.6% |
| Processing Method | Injection Molding |
| Form | Pellets |
| Color | Transparent/Natural |
As an accredited PlastxWorld CEVIAN® MABS E81 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | PlastxWorld CEVIAN® MABS E81 is supplied in 25 kg moisture-resistant paper bags, palletized for convenient handling and storage. |
| Container Loading (20′ FCL) | PlastxWorld CEVIAN® MABS E81 palletized and loaded into a 20′ FCL container, secured for export transport. |
| Shipping | PlastxWorld CEVIAN® MABS E81 is a methyl methacrylate–acrylonitrile–butadiene–styrene copolymer, typically supplied as pellets. Ship in clean, dry, ventilated containers protected from moisture, heat, and direct sunlight. Follow the SDS and applicable transport regulations for classification, packaging, labeling, and handling. |
| Storage | Store PlastxWorld CEVIAN® MABS E81 in a cool, dry, well-ventilated area, away from direct sunlight, heat, flames, and moisture. Keep in tightly closed original packaging, protected from dust and contamination. Avoid prolonged storage above recommended temperatures and segregate from incompatible chemicals. Ensure containers are clearly labeled and inspected regularly for damage or leaks. Follow the SDS and local regulations. |
| Shelf Life | PlastxWorld CEVIAN® MABS E81 typically has a 24-month shelf life when stored unopened in a cool, dry, well-ventilated area away from sunlight. |
In handheld diagnostic housings, PlastxWorld CEVIAN® MABS E81 is processed as a high-transparency methacrylate-modified ABS where lipid resistance, alcohol resistance, and optical surface quality must be balanced against residual stress. The melt is prepared in a dehumidifying dryer at 80 °C for 3–4 h to a residual moisture below 0.05 wt%; material transfer by closed vacuum loader prevents moisture re-adsorption in humid production halls. Barrel temperatures are profiled from 220 °C at the throat to 245 °C at the nozzle, with mold surfaces held between 45 °C and 70 °C to suppress flow marks and retain flatness in lens windows. Gate design uses a wide fan gate or sequential valve gating because MABS exhibits shear-induced gloss reduction when melt-front velocity exceeds the supplier-listed window. Components intended for patient-contact or specimen-contact use are evaluated under ISO 10993-1:2020, with cytotoxicity screening to ISO 10993-5:2009 and extraction performed to ISO 10993-12:2021. Biological safety is not inferred from the polymer alone; final device configuration, colorants, mold release residues, and assembly adhesives must be included in the test article. The most common production failure mode is sink over internal snap features adjacent to the optical window; holding pressure must be stage-ramped and the window thickness transition kept below 1.5:1 to avoid visible density bands. Flame treatment or corona discharge should not be applied to the lens surface because localized surface oxidation changes wetting and can produce interference fringes under polarized light inspection.
| Parameter | Range | Measurement/control basis |
|---|---|---|
| Pre-drying temperature | 80 °C | Desiccant dryer, dew point ≤ -20 °C |
| Pre-drying time | 3–4 h | Sealed cold pellets at 23 °C, 50 % RH |
| Maximum residual moisture | 0.05 wt% | Karl Fischer or calibrated moisture analyzer |
| Melt temperature | 230–250 °C | Nozzle thermocouple; avoid sustained exposure above 260 °C |
| Mold temperature | 45–70 °C | Mold surface thermocouple, optical-grade finish |
| Injection speed | low to moderate | Melt-front acceleration controlled to avoid jetting |
A butt weld in a multi-gated transparent diagnostic cartridge concentrates residual orientation and free-volume differences at the melt-front convergence. Weld-line strength in MABS is governed by melt temperature at the merge point, mold wall temperature, and the distance between gate and feature. When the cartridge body carries a 1.0 mm wall and supports a press-fit Luer hub, the weld line must be positioned away from the annular stress ring, or the male taper is at risk of circumferential cracking during connection. Production-scale injection molding machines with clamp forces from 600 kN to 1,200 kN are used for multi-cavity cartridge tools; the runner system is balanced to ≤ 3 % volumetric fill variation, measured by short-shot progression. Tensile evaluation of weld-line coupons is performed to ISO 527-2, with the weld-line index calculated as the ratio of welded to unwelded tensile stress at break. Published data for CEVIAN® MABS E81 weld-line retention is limited; the standard method requires testing a double-gated plaque, but the numerical acceptance threshold must be agreed for each cartridge geometry. Charpy notched impact to ISO 179-1:2010 is used as a secondary fracture indicator, but notch sensitivity in transparent parts does not correlate directly with weld-line performance. Mold temperature is held at the upper end of the recommended range near the weld zone by independent cartridge heater circuits, because higher mold temperature promotes interdiffusion at the merge front. Venting placement is also critical: air traps at the final fill point create localized burning and eliminate weld-line strength. Vacuum-assisted tool venting to -0.06 MPa relative pressure is applied in tools where final melt convergence occurs in a blind pocket. If the cartridge is gamma-sterilized after assembly, weld-line tensile retention should be retested after irradiation because oxidative sites at free surfaces may shift the failure mode from ductile to brittle.
In single-use diagnostic material qualification, gamma irradiation at 25–50 kGy introduces two competing effects: dose-dependent color shift and post-sterilization tensile decay. The CEVIAN® MABS E81 component is often irradiated in sealed pouches after assembly, so the polymer receives both direct radiation and secondary electron scatter from the packaging materials. The critical validation pathway is not limited to mechanical retention at 25 kGy; the maximum set point stated in the sterilization validation must be tested because yellowness index drift is not linear with dose. Color measurement is performed to ASTM E313-20 or ISO 7724, while transmission and haze are recorded to ASTM D1003-21. Class-level MABS materials may retain impact resistance better than general-purpose ABS after gamma exposure, but the methacrylate phase may show more yellowing than medical polycarbonate at equivalent dose. Validation must be performed on the production-colored compound, because organic colorants can mask early dose-induced yellowing but can also degrade into extractable species. A full biological evaluation matrix includes ISO 10993-1:2020 as the primary decision standard, ISO 10993-5:2009 for cytotoxicity of post-irradiated extract, and ISO 10993-10:2010 for skin sensitization when the device includes a patient-contact interface. If the device is labeled reusable, the reprocessing standard ISO 17664-1:2021 applies, and the cumulative effect of repeated disinfection and sterilization cycles must be assessed against a defined maximum service life. Published data for CEVIAN MABS E81 under high-humidity gamma irradiation is limited; a conservative approach is to pre-qualify the supply chain with no more than 3 production lots and to monitor yellowness index drift in stability storage at 40 °C and 75 % RH for 12 months.
| Reprocessing condition | Standard designation | Assessment focus |
|---|---|---|
| Gamma irradiation | ISO 11137-1:2006/Amd 2:2019 | Dose 25–50 kGy; post-irradiation yellowness index by ASTM E313-20; impact retention by ISO 179-1:2010 |
| Ethylene oxide sterilization | ISO 11135:2014; ISO 10993-7:2008/Amd 1:2022 | Residual EtO after aeration at 45–50 °C; dimensional recovery of press-fit features |
| Alcohol disinfectant contact | ISO 22088-3:2006 | Constant strain from 0.2 % to 1.5 %; 70 % IPA or ethanol at 23 °C |
| Thermal exposure boundary | ISO 306:2022 | Vicat softening baseline; continuous service below 65 °C in rigid transparent components |
Repeated alcohol-based disinfectant contact introduces a stress-cracking boundary that cannot be resolved by polymer drying or molding conditions alone. The methacrylate phase in MABS provides transparency and surface hardness, but it also makes the material more sensitive to polar solvent attack than unmodified ABS. In clinical devices with snap-fit covers, the outer fiber strain at the snap underclosure often exceeds 0.5 %; when this strain is combined with 70 % isopropyl alcohol or ethanol at 23 °C, environmental stress cracking can initiate at gate areas, weld lines, or ejector pin witness marks. The appropriate test is ISO 22088-3:2006 using constant-flexural-strain jigs at controlled strain steps from 0.2 % to 1.5 %, with disinfectant applied as a 10-minute immersion every 60 minutes to simulate intermittent clinical wiping. Test coupons must be machined from production-injected plaques, not compression-molded sheets, because frozen-in shear orientation changes the ESC threshold. Processors can reduce risk by moving snap features away from visible surfaces, increasing corner radii above 0.5 mm, and specifying high-temperature mold oil tempering lines to reduce mold-flow-induced stress. However, these actions do not eliminate chemical incompatibility; they only shift the critical strain threshold. Ultrasonic welding of MABS housings after molding creates additional residual stress at the horn contact ring. In alcohol-exposed devices, ultrasonic joints must be redesigned to shear joints rather than energy-director designs, because the high local heating and residual hoop stress create a preferential crack path. If the product label requires repeated cleaning with oxidizing disinfectants such as 0.5 % sodium hypochlorite, the converter must evaluate surface haze after 5,000 wiping cycles in addition to ESC testing. Published data for CEVIAN MABS E81 under specific quaternary ammonium-alcohol blended disinfectants is limited; a change in disinfectant chemistry requires retesting because surfactants in quaternary formulations can lower the critical strain.
Thick-wall CEVIAN MABS E81 closures in prestige fragrance and skincare packaging enter production under two conflicting requirements: high perceived depth of clarity and sufficient tensile strength for torque retention. The cap is usually molded as a heavy side-wall cylinder with a wall thickness between 2.0 mm and 4.0 mm; thick sections extend cycle time and create sink or voiding if packing pressure is released too early. A mold temperature of 55–65 °C is preferred to maintain smooth surface finish, but high mold temperature can complicate in-line insertion of ethyl-vinyl acetate sealing liners. The material is not a fragrance barrier polymer, so low-viscosity fragrance esters may permeate the MABS wall or concentrate at the closure-to-bottle thread interface. Compatibility testing with fragrance concentrate is performed using ISO 527-2 tensile bars after 30-day immersion at 40 °C and 45 % RH in sealed glass vials. Weight change, tensile strength retention, and visual crazing are recorded, with a weight change exceeding 0.8 % triggering a barrier liner review. Optical clarity of the closure is measured to ASTM D1003-21; highly polished tool inserts with Ra below 0.025 µm are required to avoid flow haze. The gate location is placed in the interior of the closure at a diameter inside the cap skirt, not on the crown, because a crown gate leaves a visible thermal imprint. For metalized or lacquered finishes, hot-stamping foils are applied after a corona or plasma pre-treatment, but surface energy must be measured to ISO 19403-2:2020; values below 38 mN/m indicate over-treatment or mold release contamination.
When CEVIAN MABS E81 is selected for LED appliance lenses, the optical acceptance window is set by total luminous transmittance and wide-angle haze, not by mechanical toughness alone. Sheet-free lenses with a wall thickness of 2.0 mm are injection molded with high-gloss cavity steel and low injection speeds to avoid silver streaks. Total luminous transmittance and haze are measured to ASTM D1003-21; MABS class materials generally show high initial clarity, but residual gate stress can raise haze by 0.5–1.5 % when using a single submarine gate into a cold runner. For LED light engines, the lens should not exhibit gross color separation at the blue-pumped white LED edge. Optical distortion is controlled by polishing the cavity to a lens-grade surface and by maintaining a minimum distance between the gate and the lens edge. Flow-induced birefringence is assessed qualitatively under polarized light and, if required, quantified by photoelastic retardation. Luminance uniformity across the lens is verified at the luminaire level by goniophotometry to CIE S 025/E:2015; the polymer is one factor, but LED binning and diffuser sheet selection dominate. If the lens is exposed to continuous service temperatures above 60 °C near heat sinks, the converter should request CEVIAN E81 Vicat data to ISO 306:2022 and compare against the measured board temperature. MABS is not recommended for high-intensity halogen replacement or COB LED applications where lens surface temperature exceeds 75 °C, because visible deformation may occur over extended cycles. Vibration resistance of snap-fit lens tabs is verified by sinusoidal sweep to IEC 60068-2-6:2007, with resonance points not coinciding with the compressor operating frequency in appliance enclosures.
Closed-loop regrind utilization for MABS E81 is limited by yellowness index drift and melt viscosity shift rather than by tensile property collapse. In non-optical perimeter frames, regrind from hot runners is granulated to 8–10 mm and re-dried at 80 °C for 4 h before blending with virgin material. The blend ratio is normally capped at 20 wt% because higher regrind levels change the melt flow characteristics and increase the frequency of black specks in white or transparent grades. Melt volume-flow rate is measured to ISO 1133-1:2022 at 220 °C with 10 kg load; the measured shift across 5 processing cycles determines the allowable regrind ceiling. Silo-to-silo transfer through pneumatic lines should be avoided for regrind because fines accumulate in the hopper and burn, producing yellow streaks. Instead, vacuum conveying with down-cyclone filtration and metal-separation sieves is used. The re-introduction point should be downstream of the desiccant hopper to prevent flow channeling. Injection pressure controllers must compensate for shot-to-shot viscosity variation when regrind content exceeds 10 wt%; otherwise cavity-to-cavity mass variation can exceed 0.5 %. For medical or consumer optical bodies, any regrind re-use requires written customer approval and re-validation of ISO 10993-1:2020 biological evaluation where applicable. Published data for CEVIAN MABS E81 regrind retention under gamma irradiation is limited; conservative supply chains exclude regrind from irradiation-sterilized components.
Food-contact sight glasses and transparent appliance reservoirs made from CEVIAN MABS E81 require migration documentation before mold qualification. The grade cannot be automatically assumed to comply with food-contact regulations; the converter must obtain CEVIAN E81-specific documentation against FDA 21 CFR and EU 10/2011. ABS copolymers are referenced in FDA 21 CFR 177.1020, but the methacrylate modification in MABS requires grade-level confirmation because monomers, additives, and colorants are composition-dependent. For repeated food-contact use, overall migration testing is performed in food simulants specified by EU 10/2011: 3 % acetic acid, 10 % ethanol, 20 % ethanol, and 50 % ethanol, with time-temperature conditions matched to actual service. MABS is not suited for boiling-water exposure or microwave reheating because its Vicat softening temperature places continuous-use rigid service below 65 °C. Dishwasher thermal cycles with internal temperatures above 70 °C can cause dimensional warpage, particularly in tall sight-glass housings with constrained end seals. Designers often specify a minimum wall thickness of 1.5 mm and avoid metal thread inserts, because thermal expansion mismatch between MABS and brass inserts creates radial stress cracks. The reservoir surface should not be polished with abrasive cleaners, and concentrated citrus oils should be excluded from contact because terpenes act as stress-cracking agents in methacrylate-containing polymers. If the component contacts fatty foods, repeated extraction in olive oil or isooctane simulant is required to identify low-molecular-weight extractables, and the result is viewed alongside the overall migration limit of 10 mg/dm² for plastic food-contact materials. Published data for CEVIAN MABS E81 in high-fat simulant extraction is limited; a pre-qualification study with the specific food type is recommended.
Competitive PlastxWorld CEVIAN® MABS E81 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
PlastxWorld CEVIAN® MABS E81 is supplied as a methyl methacrylate–acrylonitrile–butadiene–styrene copolymer pellet for transparent injection-moulded and extruded components. The methyl methacrylate comonomer balances the refractive index between butadiene rubber domains and the styrene-acrylonitrile phase, which permits light transmission values cited for MABS grades in the range 88 % to 90 % at 3 mm wall thickness under ASTM D1003-21. Unlike high-clarity PMMA, the MABS structure retains an impact-modified butadiene domain; class-typical notched Izod data lie between 80 J/m and 150 J/m at 23 °C per ASTM D256-10, whereas PMMA commonly falls below 30 J/m. Nominal density for injection MABS is 1.08–1.10 g/cm³ per ISO 1183-1:2019. Grade-specific values for CEVIAN® MABS E81, including lot-level melt mass-flow rate and tensile modulus, are defined in the prevailing certificate of analysis and technical data sheet issued by PlastxWorld.
Transparent ABS achieves clarity through rubber-particle sizing or matrix-index modification, but residual haze at 3 mm is commonly 3 % to 6 % under ASTM D1003-21. MABS formulations reduce this haze to a cited class range of 1 % to 3 % because the methyl methacrylate comonomer lowers the refractive index mismatch with the butadiene phase. The consequence is not purely optical: incorporation of methyl methacrylate raises the polarity of the continuous phase, which alters paintability, plating, and solvent susceptibility. In comparison with PMMA, CEVIAN® MABS E81-type materials exhibit lower tensile strength—class-typical 45 MPa to 55 MPa under ASTM D638-14 versus 60 MPa to 75 MPa for PMMA—but provide higher ductile and impact response. Flexural modulus reported for MABS is typically 1800 MPa to 2400 MPa per ASTM D790-17 or ISO 178:2019. Melt processability is closer to ABS than PMMA, with lower melt viscosity at equivalent shear rates, which permits filling of thin-walled parts at lower clamp-force demand. Published data for CEVIAN® MABS E81 in direct injection-moulding comparison with PMMA in the same mould are limited; therefore tool-specific comparative sampling is required for cycle-time claims.
Pre-drying is mandatory for CEVIAN® MABS E81 when ambient relative humidity exceeds 60 %. Desiccant-bed drying equipment capable of delivering air at a dew point of -40 °C or lower is specified; single-stage hot-air hopper dryers do not reliably reduce residual moisture below the upper limit required for transparent mouldings. A drying set point of 80 °C ± 5 °C for 3–4 h is the class-recommended procedure for virgin pellets. Throughput should not exceed the dryer’s rated air-flow capacity; a figure of 3.8 m³/h per kg/h of pellet consumption is a common sizing rule for styrenic copolymers. Moisture levels above 0.02 wt% to 0.05 wt% cause splay, silver streaks, and localized loss of notched impact due to hydrolysis of the ester comonomer. On a reciprocating screw injection-moulding machine, the measured melt pool at the nozzle should be kept between 230 °C and 250 °C using a needle pyrometer. The upper processing bound is 260 °C; above this threshold, methyl methacrylate-containing polymers can undergo depolymerization and yellowing, with volatile generation obscuring transparent surfaces. Screw geometry is not a floating parameter: a general-purpose styrenic screw with 20:1 to 25:1 L/D and compression ratio between 2:1 and 3:1 is appropriate. High-compression screws or high-shear mixing sections should be avoided unless the resulting melt temperature remains within limit.
When regrind is introduced at levels up to 30 wt%, drying time should be shifted to the upper end of the 3–4 h window because pellet surface area increases and bulk density becomes less uniform. Higher regrind fractions degrade optical consistency in transparent parts and are not recommended without lot-specific validation.
Substitution of PMMA with CEVIAN® MABS E81 in a transparent housing is most appropriate when the part contains snap-fit features, living hinges, or internal mounting bosses that would otherwise fracture in PMMA. The butadiene phase provides the necessary energy absorption; however, the lower modulus relative to PMMA requires evaluation of wall deflection and creep under load. Mould surface temperature can be lowered to 50 °C to 70 °C, whereas PMMA may require 70 °C to 90 °C for equivalent surface replication. This difference can reduce cycle time in simple two-plate moulds by 10 % to 20 %, but the result is geometry-dependent and must be confirmed by in-mould thermocouple data rather than inferred from material class. For wall thicknesses below 1.5 mm, fill speed should be raised until the flow front remains continuous; hesitation and jetting produce visible flow lines in transparent materials. Vent depth at the parting line should be 0.02 mm to 0.03 mm for MABS; shallower venting leads to gas marks, while deeper venting can flash at standard injection pressures.
Typical filling pressure for thin-wall MABS is 60 MPa to 100 MPa at the machine, with hold pressure adjusted to 40 MPa to 70 MPa after the gate freeze time is established by part-weight stabilisation. Back pressure should be limited to 0.5 MPa to 1.0 MPa; excessive back pressure raises melt temperature and accelerates degradation. Screw rotation speed on a 40 mm diameter screw is generally 60 min⁻¹ to 120 min⁻¹. These set-points are class-typical for medium-tonnage reciprocating screw machines and are not a substitute for a documented mould trial using CEVIAN® MABS E81.
Chemical compatibility of CEVIAN® MABS E81 is determined by the SAN-MMA continuous phase. Dilute aqueous acids and alkalis at ambient temperature are generally acceptable for intermittent contact; ketones, esters, aromatic hydrocarbons, and chlorinated solvents are not acceptable because they attack the matrix or induce environmental stress cracking. In comparative terms, MABS often shows better resistance to ethyl alcohol and isopropanol than PMMA, which is beneficial for hand-held medical or cosmetic housings disinfected with alcohol-based cleaners. However, prolonged immersion or vapour contact above 40 °C can still cause crazing. Published E81-specific chemical immersion data are limited; therefore, compatibility must be tested according to ASTM D543-21 or ISO 22088-3 before design release. For applications requiring repeated exposure to disinfectants, moulded specimens should be tested under strain introduced by a jig corresponding to the designed snap-fit or boss load; unstressed coupon data underreport stress-cracking risk.
Hot water exposure above 70 °C is a further operational boundary. MABS contains ester functionality; continuous exposure to hot water or steam can hydrolyze the methyl methacrylate unit at a slow rate, causing surface haze and molecular weight loss. Autoclaving is not recommended unless a specific grade of CEVIAN® MABS E81 is validated under ISO 17665-1 or equivalent for the target cycle. Avoid combination with amine-based mould-release agents or amine-containing processing aids, which can promote surface attack and yellowing in styrenic/acrylic matrices.
In long-flow transparent parts, the limiting variable is not injection speed but melt-temperature uniformity. CEVIAN® MABS E81 processed through unheated cold sprues or poorly designed hot-runner manifolds can exhibit local yellowing at the gate while the melt front remains underheated. Manifold and nozzle zones should be individually controlled within ±5 °C of the barrel set point; deviation beyond this narrow window produces optical defects in transparent MABS because the melt residence time in the manifold is longer than the barrel residence time. The total shot size should be 30 % to 75 % of barrel capacity; smaller shots increase residence time and thermal history, while larger shots may not provide uniform plasticating. When filling thin-wall parts below 1.5 mm, injection velocity should be profiled from a moderate initial stage to a high final stage to prevent jetting and entrapped air. A short-shot progression of 90 %, 95 %, and 98 % of fill volume is used to establish the switch-over point from velocity control to pressure control; the exact switch-over is determined by cavity pressure readings from a sensor installed near the gate, not by linear position alone.
Hot-runner valve gates should open with sufficient velocity to initiate a continuous flow front but not so rapidly as to tear the melt. Gate diameter for transparent MABS is typically 0.8 mm to 1.5 mm for wall sections of 1.5 mm to 2.5 mm; smaller gates can cause high shear and local temperature increases exceeding 260 °C, visible as gate blush. For cold-runner tools, full-round or trapezoidal runners with polished surfaces are used; runner diameter should be at least 6 mm for parts up to 100 g to avoid pressure-limited filling.
Extrusion compounding of CEVIAN® MABS E81 on a co-rotating twin-screw extruder with 36:1 L/D requires close control of screw speed and melt temperature. Class-typical MABS can be processed on single-screw extruders for sheet or profile, but twin-screw mixing is not necessary for virgin pellet homogenization and increases shear heating. When compounding color concentrates or additives, the melt temperature measured at the die plate should remain below 260 °C. A screw speed of 300 min⁻¹ to 600 min⁻¹ on a 25 mm to 40 mm twin-screw extruder is common for styrenic dispersions, but the relationship between speed and melt temperature is machine-specific. Strand pelletizing is used after a water bath; bath temperature should not exceed 60 °C if amorphous transparency is to be retained without developing surface microcracks. Recycled material from sprues and runners up to 20 wt% is generally tolerated in non-critical optical parts; repeated heat cycles degrade impact strength and produce yellowing. Published data for E81-specific regrind retention of light transmission are limited; therefore, each lot of regrind should be evaluated under ASTM D1003-21 before use in transparent parts.
Thermal stability can be monitored by melt mass-flow rate shift. A shift greater than 10 % from virgin material at the same standard conditions under ISO 1133-1:2022 indicates excessive thermal history or moisture-induced degradation. Spectrophotometric measurement of yellowness index under ASTM E313-20 or ISO 11664-4:2021 provides a second control boundary; a ΔYI greater than 1.0 in a 3 mm plaque is generally visible against a white background.
The following table summarises class-typical property ranges for MABS as a material family, based on published injection-moulding data and applicable test standards. Values are not a substitute for the CEVIAN® MABS E81 certificate of analysis, but they define the expected design window for initial engineering calculations.
| Property | Test method | Class-typical value or range |
|---|---|---|
| Density | ISO 1183-1:2019 | 1.08–1.10 g/cm³ |
| Melt mass-flow rate at 220 °C, 10 kg | ISO 1133-1:2022 | 5–20 g/10 min |
| Tensile strength at yield | ASTM D638-14 / ISO 527-2:2012 | 45–55 MPa |
| Tensile elongation at break | ASTM D638-14 | 10–30 % |
| Flexural modulus | ASTM D790-17 / ISO 178:2019 | 1800–2400 MPa |
| Notched Izod impact at 23 °C | ASTM D256-10 / ISO 180:2019 | 80–150 J/m (5–10 kJ/m²) |
| Light transmittance at 3 mm | ASTM D1003-21 | 88–90 % |
| Haze at 3 mm | ASTM D1003-21 | 1–3 % |
| Vicat softening temperature 50 N | ISO 306:2022 | 90–100 °C |
| Heat deflection temperature 1.82 MPa | ASTM D648-18 | 80–90 °C |
Regulatory documentation for CEVIAN® MABS E81 is supplier-specific and cannot be inferred from the MABS class alone. For European Union articles, REACH obligations under Regulation (EC) No 1907/2006 include SVHC declarations under Article 33 when applicable. RoHS recast Directive 2011/65/EU restriction substances are typically controlled, but the buyer should request an Annex II screening statement for the exact lot. Food-contact status, if required, is assessed under Commission Regulation (EU) No 10/2011 for plastic materials intended for food contact, with overall migration and specific migration limits dependent on the food simulant. For United States applications, the relevant FDA 21 CFR citation is formulation-dependent and may be evaluated under 177.1020 for acrylonitrile copolymers or an applicable food-contact notification; a grade-specific suitability letter is mandatory. Medical device materials require ISO 10993-5 cytotoxicity and, if blood contact is intended, additional testing under ISO 10993-4. The table below identifies the document class required for first-article qualification.
| Compliance document | Issuing entity/standard basis | Use boundary |
|---|---|---|
| REACH SVHC declaration | PlastxWorld or resin manufacturer, Article 33 of Regulation (EC) No 1907/2006 | Applies to EU/EEA article supply |
| RoHS Annex II screening | IEC 62321-5:2021 or equivalent | Electrical/electronic equipment components |
| EU food contact conformity | Commission Regulation (EU) No 10/2011 migration testing | Only when grade is listed for food contact |
| FDA food-contact suitability | 21 CFR citation from resin manufacturer | Only with written grade-specific clearance |
| ISO 10993-5 cytotoxicity | Accredited test laboratory | Medical device housing/patient-contact accessories |
| UL 94 flame rating | UL yellow card or equivalent | Not intrinsic to MABS; formulation-dependent |